• Title/Summary/Keyword: cop

Search Result 1,228, Processing Time 0.024 seconds

Studies on Performance of CO2 Water Heater by Numerical Modeling (수치적 모델링을 통한 이산화탄소 급탕기의 특성 연구)

  • Park, Han Vit;Yun, Rin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.1
    • /
    • pp.20-27
    • /
    • 2013
  • Numerical modeling of $CO_2$ water heater was conducted prior to optimal design of medium and large sized $CO_2$ water heater, and the experimental test with small sized $CO_2$ water heater having heat capacity of 4 kW was completed to verify the present numerical model. The present model estimated the experimental data of COP(coefficient of performance), heating capacity, and the hot water outlet temperature within the range of 3% to 8% of mean deviation. As increase of EEV(electric expansion valve) opening area, decreasing of heating capacity and the hot water outlet temperature, and increasing of COP were found in both experimental and numerical investigation.

Thermodynamic Efficiency of Metal Hydride Heat Pump (금속수소화물을 이용한 히트펌프의 열역학적 효율)

  • Park, C.K.;Komazaki, Y.;Suda, S.
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.3 no.2
    • /
    • pp.1-7
    • /
    • 1992
  • New type of metal hydride heat pump (MHHP) combined with hydrogen compressor was constucted for cooling purpose. A model for calculating the coefficient of performance (COP) is presented for MHHP which consisted of two different stages (enforced and natural stage), and compared with the experimental results. A concept of adiabatic compression work is introduced in the model on the basis of Carnot reversible analysis and the dependence of COP on the various operational parameters is discussed.

  • PDF

Protection and Electrostatic Analysis of the Industrial Type Inkjet Plotter using FEM (유한요소법을 이용한 산업용 잉크젯 플로터의 정전기 해석과 대책)

  • Yoon, S.Y.;Choi, G.S.;Kim, Y.;Baek, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1496-1499
    • /
    • 2005
  • This paper was represented an electrostatics distribution analysis using FEM(finite element method) with industrial type Inkjet plotter. Here, we know electronic value with each system position by experiment. these were decreased by discharge through earth and electricity shielding. According to industrial development, all fields using chemical instrument and material are generated an electrostatics. Based on these, the big large position of electrostatics was obtained metal base of controller, nonconductor fiber between two rubber roller, head controller by moving roller etc., Therefore these were showed an electrostatics generation source and by rubbing and meager profits electric charge.

  • PDF

A Study on Performance Characteristics of A Single Effect LiBr/Water Refrigeration Cycle (단효용 LiBr/물 흡수식 냉동사이클의 성능특성에 관한 연구)

  • 연제문;임삼택;오주원;이경우
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2001.05a
    • /
    • pp.95-99
    • /
    • 2001
  • As a way to use energy effectively, the present study is aimed at investigating the performance characteristics of a Single Effect LiBr/Water Absorption Refrigerator using a low temperature driving heat-source. It was carried out by changing the driving heat-source temperature, the cold water outlet temperature(the refrigeration load), the cooling water inlet temperature, and the weak solution flow rate and this study compares the performance characteristics of refrigerator against the existence and non-existence of the Recirculation of the Weak solution which is used as a method to improve the performance of refrigerator. In case of Recirculation of the weak solution, more improved the Refrigeration Capacity and COP was obtained, and these effects became more larger in the high temperature of driving heat-source and large quantity of solution.

  • PDF

A study of frequency control of an inverter heat pump for indoor air temperature adjustment (실내온도조절을 위한 인버터 열펌프의 주파수 제어에 관한 연구)

  • Park, Yun-Cheol;Min, Man-Gi
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.10
    • /
    • pp.1262-1272
    • /
    • 1997
  • An experimental study on the frequency control of an inverter heat pump to get the desired indoor room temperature has been conducted for the performance characteristics during the steady, 4, 8, and 16 step frequency operations. The heat pump model used in this study was operated to meet the experimental conditions of ASHRAE standard. The performance of the system was tested by measuring the temperature and pressure of the refrigerant, and cooling capacity, power consumption, etc. of the system. As the controlling frequency steps increased, the running time of the compressor increased as well as the electric consumption of the system and the cooling energy due to the wall heating load. However, the average cooling COP was improved.

Feasibility Study on the Frost Prevention and Delay by the Method of Alternating the function of Outdoor Coil Rows (실외기 기능 교번을 통한 착상 방지 및 지연에 대한 실증 연구)

  • Jeon, Chang Duk
    • Journal of Institute of Convergence Technology
    • /
    • v.1 no.1
    • /
    • pp.1-4
    • /
    • 2011
  • The object of this experimental study is to investigate the effect on frost prevention and delay by the method of alternating the function of outdoor coil rows under the frost conditions ($2^{\circ}C/1^{\circ}C$). The heat pump system with the new method can make frost delay time longer and eliminate frost effectively. It is withstand over 280 minutes without a conventional defrosting method. Maximum COP in case of adopting new method is 13% higher than that in case of reverse cycle defrosting method. Also in case of moving air injection duct faster, the frost delay time is lengthened and its COP is enhanced more.

  • PDF

Complex Detection Between Transcription Regulator and Promoter DNA by UV Spectroscopic Method

  • Lee, Kyungmin;Gang, Jongback
    • Journal of Integrative Natural Science
    • /
    • v.5 no.3
    • /
    • pp.163-167
    • /
    • 2012
  • UV spectrophotometer was used to detect protein-DNA complex from DNA melting profile under constant temperature increase. Melting temperature (Tm) was $43^{\circ}C$ in copA duplex DNA alone. In the presence of Proteus mirabilis transcription regulator protein (PMTR) protein at 0.2 and 0.4 ${\mu}M$, Tm's were $45{\pm}0.5$ and $47.6{\pm}0.6^{\circ}C$, respectively. According to fluorescence polarization and gel shift assay. PMTR:copA complex was detected by the retarded migration on gel and the dissociation constant ($K_d$) was $(9.2{\pm}2.8){\times}10^{-9}M$.

Cooling-Heating System Using Thermoelectric Module and Parallel Flow Type Pulsating Heat Pipe

  • Kim Jeong-Hoon;Im Yong-Bin;Lee Seong-Ho;Lee Euk-Soo;Kim Jong-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.13 no.4
    • /
    • pp.217-224
    • /
    • 2005
  • The purpose of this study was to develop a cooler/heater using a thermoelectric module combined with a parallel flow type pulsating heat pipe with R-142b as a working fluid. The experiment was performed for 16 thermoelectric modules (6A/15V, size: $40\times40\times4mm$), varying design parameters of the heat pipe (inclination angle, working fluid charging ratio, etc.). Experimental results indicate that the optimum charging ratio and the inclination angle of the parallel flow type pulsating heat pipe were $30\%$ by volume and $30^{\circ}$, respectively. The maximum cooler/heater capacity were 479 W (COP: 0.47) and 630 W (COP: 0.9), respectively.

Heat Transfer Analysis for Optimum Design of a Thermoelectric Cooler (열전 냉각기의 최적 설계를 위한 열전달 해석)

  • 김제익;박찬형;강용태;최창균
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.11
    • /
    • pp.889-894
    • /
    • 2003
  • The objectives of this study are to present a proper mathematical model for a thermoelectric cooler equipped with the spacer and to investigate the effect of its geometries by heat transfer analysis. In order to enhance the efficiency of the thermoelectric cooler, the spacer is inserted between TEM (thermoelectric module) and cold plate. The theoretical results show that the COP (coefficient of performance) increases nonlinearly as high as 0.63 with increasing the depth of spacer and the depth of TEM and with decreasing the area of insulator.

Part-Load Performance Test of a Screw Chiller with Economizer using R22 and R407C (이코노마이저를 채용한 스크류 냉동기에서 R22와 R407C의 부분부하 성능실험)

  • 장영수;이용철;김영일
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.11
    • /
    • pp.902-909
    • /
    • 2003
  • Screw compressor type chillers are widely used in refrigeration for capacity over 30 RT. In general, chillers operate under part-load conditions. Therefore, information on characteristics at part-load is very important in view of chiller performance and energy economy. In this study, performance tests of part-load and economizer system using R22 and R407C have been performed for various secondary fluid temperatures. Adoption of an economizer system increased the cooling capacity and improved COP except for lower part-load condition when injection volume ratio is 1.01. For the same cooling capacity condition at part-load, COP of both non-economizer and economizer system showed similar values.