• Title/Summary/Keyword: cop

Search Result 1,228, Processing Time 0.029 seconds

A Study on COP-Transformation Based Metadata Security Scheme for Privacy Protection in Intelligent Video Surveillance (지능형 영상 감시 환경에서의 개인정보보호를 위한 COP-변환 기반 메타데이터 보안 기법 연구)

  • Lee, Donghyeok;Park, Namje
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.28 no.2
    • /
    • pp.417-428
    • /
    • 2018
  • The intelligent video surveillance environment is a system that extracts various information about a video object and enables automated processing through the analysis of video data collected in CCTV. However, since the privacy exposure problem may occur in the process of intelligent video surveillance, it is necessary to take a security measure. Especially, video metadata has high vulnerability because it can include various personal information analyzed based on big data. In this paper, we propose a COP-Transformation scheme to protect video metadata. The proposed scheme is advantageous in that it greatly enhances the security and efficiency in processing the video metadata.

Effects of Vibratory Stimulus on Postural Balance Control during Standing on a Stable and an Unstable Support (안정판과 불안정판에서 자세 균형 조절에 대한 진동자극의 영향)

  • Yu, Mi;Eun, Hey-In;Kim, Dong-Wook;Kwon, Tae-Kyu;Kim, Nam-Gyun
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.5
    • /
    • pp.647-656
    • /
    • 2007
  • The purpose of this study was to analyze the effects of vibratory stimulus as somatosensory inputs on the postural control in human standing. To study these effects, the center of pressure(COP) was observed while subjects were standing on a stable and an unstable support with co-stimulated mechanical vibrations to flexor ankle muscles(tibialis anterior tendon, achilles tendon) and two plantar zones on both foot. The COP sway measurement was repeated twice in four conditions: (1) with visual cue and vibration, (2) without visual cue and vibration, (3) with visual cue and without vibration, (4) without visual cue and with vibration. The calculated parameters were the COP sway area and the distance, the median frequency and the spectral energy of COP sway in three intervals $0.1{\sim}0.3,\;0.3{\sim}1,\;1{\sim}3Hz$. The results showed that vibratory stimulus affect postural stability. The reduction rate of the COP sway with vibratory stimulus were higher on the unstable support because the effect of postural stability increases when afferent nervous flow is more activated by vibration on unstable support. If unclear visual or vibratory information is received, one type of information is compared with the other type of sensory information. Then the input balance between visual and vibratory information is corrected to maintain postural stability. These findings are important for the rehabilitation system of postural balance control and the use of vibratory information.

An Experimental Study on the Cooling and Heating Performance of a Residential Ground Source Heat Pump System (가정용 지열원 열펌프 시스템의 냉난방 성능 특성 연구)

  • Kong, Hyoung Jin;Kang, Sung Jae;Yun, Kyoung Sik;Lim, Hyo Jae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.3
    • /
    • pp.156-163
    • /
    • 2013
  • Ground Source Heat Pump (GSHP) systems utilize geothermal energy as a thermal source or sink, for heating, cooling and domestic hot water. It is well known that GSHP is environmentally friendly, and saves energy dramatically. For this reason, many investigative researches have been conducted on commercial and governmental buildings. However, studies on residential GSHP are few, because of the small capacity and cost. In this study, we experimented with the characteristic performance of heating, cooling and seasonal performance factor for a residential GSHP system, which consisted of two 180 m deep u-tube ground heat exchangers, a heat pump and measurement instruments. The installed capacity of the heat pump was 5RT, and the conditioning area was $62.23m^2$. From the experimental results, the cooling COP of the heat pump was 4.13, and the system COP was 3.51, while the CSPF was 3.32. On the other hand, the heating COP of the heat pump was 3.87, and the system COP was 3.39, while the HSPF was 3.39. Also, in-situ cooling COP and capacity were 93.7% and 96.4% compared with the EWT certification data, respectively, and that of heating were 98.3% and 95.7%, respectively.

Validity of Ground Reaction Forces during Gait and Sit-to-Stand using the Nintendo Wii Balance Board in Healthy Subjects (Wii Balance Board를 이용한 Sit-to-Stand와 보행시 지면반발력의 타당도 분석)

  • Jeong, Yu-Jin;Park, Dae-Sung
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.11 no.4
    • /
    • pp.85-92
    • /
    • 2016
  • PURPOSE: A good, valid, and feasible tool for evaluating sit to stand (STS) is needed to help clinicians quantify the STS ability of stroke patients and people with balance disorders. The purpose of this study was to evaluate the concurrent validity of the Nintendo Wii Balance Board (WBB) and a force plate during STS and gait. METHODS: Seventeen healthy adults performed five trials of STS and gait on the WBB placed on the force plate. The force plate and the WBB were compared in regard to center of pressure (COP) and ground reaction force (GRF) data that were collected simultaneously. The variables used for analysis were time (s), integral summation (%), COP path length (mm), COP x range, and COP y range, all of which were measured for both tasks. Counter (%), peak (%), and rebound (%) were analyzed for STS, and $1^{st}$ peak (%), min peak (%), and 2nd peak (%) were analyzed for gait. The concurrent validity was analyzed using an intraclass correlation coefficient (ICC) and a standard error of measurement (SEM) with a 95% confidence interval. RESULTS: The concurrent validity of the WBB for STS ranged from fair to good (ICC=.701~.994, SEM=.029~3.815). The concurrent validity for gait was good (ICC=.869 ~.989, SEM=.007~2.052) aside from path length and x and y ranges of COP (ICC=-.150~.371, SEM=3.635~4.142). CONCLUSION: The GRF of the WBB has a good validity for STS and gait analysis. The WBB is remarkably portable, easy to use, and convenient for clinically assessing STS and gait.

Performance comparison of refrigeration cycle using R134a with the vapor-liquid ejector (증기-액 이젝터를 적용한 R134a 냉동사이클의 성능 비교)

  • Yoon, Jung-In;Kim, Chung-Lae;Son, Chang-Hyo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.9
    • /
    • pp.890-894
    • /
    • 2015
  • Recently, research on high-efficiency refrigeration cycles that apply an ejector to basic cycles has progressed actively. The role of the ejector and the performance of refrigeration cycles are subordinate to ejector locations. In this study, the performance of three refrigeration cycles with different ejector locations is compared and analyzed. The results showed an increased COP in all cycles due to the application of the ejector, with the highest increase of 44% compared to a basic refrigeration cycle. The ejector refrigeration cycle proposed in this study presents the highest COP, 3.47. Moreover, the decrease in condensation capacity in Bergander's cycle, Xing's cycle, and our proposed ejector refrigeration cycle went up to 21%. In refrigeration cycles applying the ejector, the pressure ratio of the ejector, the vapor fraction of discharge, and compression ratio are important factors for COP enhancement. For this reason, detailed and accurate control of these is significant.

Development of cascade refrigeration system using R744 and R404A - Prediction and comparison on maximum COP(Coefficient of Performance) - (R744-R404A용 캐스케이드 냉동시스템 개발에 관한 연구(2) - 최대 성능계수에 관한 예측과 비교 -)

  • Oh, Hoo-Kyu;Son, Chang-Hyo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.2
    • /
    • pp.189-195
    • /
    • 2011
  • In this paper, prediction and comparison on COP(coefficient of performance) of R744-R404A cascade refrigeration system are presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include subcooling and superheating degree, compressor efficiency, and condensing and evaporating temperature in the R404A high- and R744 low-temperature cycle, respectively. The main results were summarized as follows : The prediction for performance of R744-R404A cascade refrigeration system have been proposed through multiple regression analysis and compared with other researcher's correlations. As a result, prediction proposed in the study shows disagreement with existing equations. Therefore, it is necessary to propose the more accurate correlation predicting the COP of R744-R404A cascade refrigeration system through an addition experiments.

Comparisons between Skilled and Less-Skilled Players' Balance in Hakdariseogi (태권도 품새 우수·비 우수선수 간 학다리서기의 균형성 비교)

  • Ryu, Ji-Seon;Yoo, Si-Hyun;Park, Sang-Kyoon;Yoon, Suk-Hoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.22 no.1
    • /
    • pp.55-63
    • /
    • 2012
  • The purpose of this study was to investigate the balance differences between skilled players and less-skilled players during Hakdariseogi motion of Keumgang Poomsae in Taekwondo. To achieve the study goal, total of 10 Taekwondo athletes; 5 skilled players(S, body mass: $67.0{\pm}5.7$ kg, height: $174.0{\pm}4.8$ cm, age: $20.0{\pm}2.0$ yrs) and 5 less-skilled players(LS, body mass: $73.0{\pm}4.9$ kg, height: $176.4{\pm}6.1$ cm, age: $20.8{\pm}1.3$ yrs) participated in this study. A three-dimensional motion analysis with 8 infrared cameras and one force plate whose sampling frequency as 30 Hz and 300 Hz, respectively, were performed. Participants' motion were divided into three phases which were preparation phase(P1), performing phase(P2) and maintaining phase(P3). The range and velocities of COP, the range and RMS of ground reaction torque and displacement between COM and center of BOS of each phase were computed. In this study, at P1 and P3 which were double and single stance, respectively, the range and M-L velocities of COP revealed significantly higher in LS compared with those of S(p<.05). At P2 which was single stance, LS indicated significantly higher in range of COP and ground reaction torque, and M-L velocities of COP than those of S(p<.05). The significantly shorter displacement between COM and center of BOS, however, was found in LS compared with that of S(p<.05). The results from our study indicated that S revealed more stable performance and a better posture control ability during performing Hakdariseogi motion.

The Relationship between the Plantar Center of Pressure Displacement and Dynamic Balance Measures in Hemiplegic Gait (편마비 보행 시 족저압력중심의 이동특성과 동적균형능력의 상관관계 연구)

  • Park, Ji-Won;Nam, Ki-Seok;Back, Mi-Youn
    • Physical Therapy Korea
    • /
    • v.12 no.1
    • /
    • pp.11-21
    • /
    • 2005
  • The purpose of this study was to investigate how COP displacement of a hemiplegic foot in stance phase during gait is related to clinical balance measures and the recovery stage in hemiplegic stroke patients. Twenty-eight functionally ambulant hemiplegic patients who had suffered from strokes and thirty age-matched healthy subjects participated in this study. COP parameters were calculated. Clinical balance was measured using the Functional Reach Test (FRT) and Timed Up and Go Test (TUGT). The recovery stage, proprioception, and clonus of the ankles or lower extremities were also measured for physical impairment status. The COPx max-displacement in the medial-lateral side of the stroke patients was significantly longer than that of the normal group (p=.038). The COPy max-displacement in the anterior-posterior side of the stroke patients was significantly shorter than that of normal group (p<.001). Significant differences in the COPx and COPy displacement asymmetry index were found between the two groups (p<.01). The FRT was correlated with the COPx displacement (r=.552) and COPy displacement (r=.765). The TUGT was correlated with the COPy displacement (r=-.588) only. The recovery stage of the lower extremities was correlated with COPy displacement (r=.438). The results of the study indicate that the characteristic of COP displacement in hemiplegic feet in stance phase during gait is related to balance ability and recovery in stroke patients. COP parameters acquired by the mapping of foot pressure in stance phase during gait will provide additional useful clinical information. This information can be used by clinicians to assess objectively the pathologic gait with other diseases and to evaluate the therapeutic effects on gait in stroke patients.

  • PDF

Performance analysis for the Characteristics of Double Stage Evaporator/Absorber for Large temperature Difference Absorption System (흡수식 대온도차 시스템에서 2단 증발/흡수기의 성능 특성에 관한 수치적 연구)

  • Park, Chan-Woo;Kang, Yong-Tae;Im, Ick-Tae;Moon, Sang-Done
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.304-308
    • /
    • 2008
  • The optimal design of two stage evaporation & absorption system which is related to the large temperature difference system was investigated numerically in the absorption refrigeration system. The concentrations at inlet & oulet of absorber are 62.9% and 56.9%, but in two stage absorption system the values are 62.2% and 56.2%. Therefore strong solution & weak solution became diluted than the standard value. The amount of weak solution circulation can be reduced in absorption refrigeration system, and the sensible heat load is more reduced to enhance the COP of system. As UAR is increased, COP becomes larger, and this means the role of top section is more important than bottom section in two stage evaporation & absorption system. But the increase of COP becomes slower at 0.7 of UAR ratio. The performance of Type2 is higher than Type1 in COP with the flow direction of cooling waters. This phenomena is due to the active absorption of vapor -absorption & lower temp. cooling water is more effective. The pressure at bottom section becomes higher & that at top section becomes lower and therefore the circulation rate can be diminished more.

  • PDF

Relationship between Scene Movements and Cybersickness (화면 움직임과 Cybersickness의 관계에 관한 연구)

  • Park, Kyung-Soo;Choi, Jeong-A;Kim, Kyoung-Taek;Kim, Sang-Soo
    • Journal of the Ergonomics Society of Korea
    • /
    • v.24 no.1
    • /
    • pp.1-7
    • /
    • 2005
  • This paper investigates the effects of scene movements on cybersickness to develop the guidelines of scene movements in virtual environments. The types of scene movements were made for both scene navigations(through the axes of X: lateral, Y: fore & after, and Z: vertical) and scene rotations(by pitch, roll and yaw). And there were each three levels of speed; 2.7, 4.5 and 6.3 /s(for navigation), and 10, 20 and 30 /s(for rotation) were conducted. Twelve participants were exposed to each scene for 15 minutes, and three tests were performed to measure the degree of sickness. Before and after subjects were exposed to virtual environments, they were requested to describe their sickness symptoms by means of answering the Simulator Sickness Questionnaire(SSQ). And the postural stability tests, in which the Center of Pressure(COP) of subjects were traced and recorded by a 'force platform', were conducted. During the exposure on virtual environments, the subjects were requested to rate the degree of nausea. For both navigation and rotation, the effects of speeds and axes were significant in the SSQ scores and the nausea ratings, while it was not in the COP. The correlation between the SSQ scores and the COP data was not found. Therefore, it was inappropriate to use COP as a measure of cybersickness. The degree of sickness increased, except for the case of the yaw, as the speed increased. The sickness was most severe in the scene navigation through the axis X and in the scene rotation by the yaw.