• 제목/요약/키워드: cop

검색결과 1,225건 처리시간 0.027초

발의 냉 적용이 자세 동요와 체중 분포에 미치는 영향 (Changes of the Postural Sway and Weight Distribution According to Cooling the Foot)

  • 정형국
    • 대한물리치료과학회지
    • /
    • 제16권4호
    • /
    • pp.19-27
    • /
    • 2009
  • Background: The purpose of this study was to examine changes of postural sway and weight distribution after cooling the foot. Methods: Ten men with no history of sensory, neurological and orthopedic disorders were participated in this study. They performed four methods: (1) non-treated feet group(control group); (2) both feet treated group; (3) right foot treated group; and (4) left foot treated group. The feet of them were put into ice box, then they stood more than forty seconds on EMED system with bared feet. Data on the moving length, velocity, and maximum velocity of COP and the weight distributions during thirty seconds only were measured in standing position. Results: (1) The moving length and velocity of COP were significant difference between control group and both feet treated group only(p<0.05). (2) The maximum velocity of COP was significant difference among control group and all experimental groups. (3) The changes of weight distribution were significant difference among control group and right/left foot treated groups. Conclusions: Cooling the foot led to increased postural sway and changed weight distribution patterns.

  • PDF

열교환기 효율이 초저온 냉동사이클 성능에 미치는 영향 (Effect on Heat Exchangers Efficiency on Performance of Cryogenic Refrigeration Cycles)

  • 윤정인
    • 동력기계공학회지
    • /
    • 제17권4호
    • /
    • pp.58-63
    • /
    • 2013
  • This paper presents the new cascade liquefaction cycles using $CO_2-C_2H_6-N_2$ and $CO_2-N_2O-N_2$. The performance of the cascade liquefaction cycles with respect to temperature differences in the LNG heat exchangers is analyzed using HYSYS software and then compared the performance of these cycles with phillips optimized cascade liquefaction cycle. The coefficient of performance of the new liquefaction cycles considered in this study decreases with the temperature differences in the LNG heat exchangers, but the compressor work, expander work and heat capacity in the LNG heat exchanger increases, respectively. From the comparison of performance of three cycles, the cascade liquefaction cycles using $CO_2-C_2H_6-N_2$ showed the highest COP. And the cycles using $CO_2-C_2H_6-N_2$ and $CO_2-N_2O-N_2$ presented the second and third highest COP, respectively. In the view of performance, the optimized cascade liquefaction cycle using $C_3H_8-C_2H_4-C_1H_4$ yields much better COP. But, in the environment view, it is found that the cascade liquefaction cycle using $CO_2-C_2H_6-N_2$ shows favorable characteristics.

용량가변 방식을 적용한 압축기의 성능연구 (Performance of Compressor with Variable Capacity)

  • 권영철;진의선;허삼행;김대훈;홍주태;문제명
    • 에너지공학
    • /
    • 제13권3호
    • /
    • pp.214-218
    • /
    • 2004
  • 본 연구에서는 용량가변방식을 적용한 PWM 압축기의 냉방운전 시 소비전력 변화 및 성능향상을 조사하기 위해서 기존 및 개선된 압축기의 능력, 소비전력, COP를 측정하여 비교하였다. 압축기의 효율 향상을 위해 무부하 상태에서 압축기 운전콘덴서의 변경, 복수구동부의 교차운전, 그리고 주 전류단에 코일를 적용하여 소비전력의 변화를 측정하였다. 용량가변형인 PWM압축기는 압축기 능력이 증가함에 따라 소비전력과 COP가 선형적으로 증가하였다. 압축기의 운전 콘덴서를 바꾸어가면서 소비전력을 측정한 경우 소비전력의 최적점이 확인되었다. 한편, 복수 구동부의 적용으로 불필요한 과전압에 의한 소비전력을 감소할 수 있었다.

A Study on the Cost-Effective Personalized Plantar Pressure Measurement System

  • Kang, Ji-Woo;Kwon, Young-Man;Lim, Meoung-Jae;Chung, Dong-Kun
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제11권4호
    • /
    • pp.11-17
    • /
    • 2019
  • Plantar pressure data can be used not only for walking patterns in daily life, but also for eating, health care, and disease prevention. For this reason, the importance of plantar pressure measurement has recently increased. However, most systems that can measure both static and dynamic plantar pressure at the same time are expensive, not portable, and not universal. In this study, we propose a system that effectively reduces the number of sensors in plantar pressure system. Through this, we want to increase the economics and practicality by reducing the size and weight of the system, as well as the power consumption. First, for static plantar pressure and dynamic plantar pressure, the values measured by existing precision instruments are analyzed to determine how many measurement parts the insole is divided into. Next, for the divided measuring parts, the position of the sensor is determined by calculating the Center of Pressure (COP) for each part with the values of all dynamic and static plantar pressure sensors. Finally, in order to construct a personalized plantar pressure measurement system, we propose a weighting method for the static plantar pressure COP and the dynamic plantar pressure COP for each part.

$CO_2$ 초임계 사이클을 위한 일체형 스크롤 팽창기-압축기 성능해석 (Performance Analysis of Scroll Expander-Compressor Unit for $CO_2$ Transcritical Cycles)

  • 김현진;남보영;안종민
    • 설비공학논문집
    • /
    • 제18권5호
    • /
    • pp.434-442
    • /
    • 2006
  • In a two-stage compression $CO_2$ transcritical cycle, application of a scroll expander-compressor unit has been considered in order to improve the cycle COP. For both expander and 1st stage compressor, scroll wrap profile which was originally designed for a R410A air-conditioning cycle mechanism was used with minor modifications: wrap height and involute end angle were adjusted for required displacement volume and built-in volume ratio. For pressure condition of 10 Mpa/3.5 MPa and expander inlet temperature of $35^{\circ}C$, 25% improvement in COP was obtained by using expander-compressor unit. As evaporator pressure increased, COP improvement was lowered mainly due to decreasing compressor peformance.

응축기 배열 회수에 의한 흡수식 냉동기의 고효율화에 관한 연구 (A study on the Characteristics of the High Efficiency absorption Chiller by Heat Recovering from Condenser)

  • 박찬우
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.46-51
    • /
    • 2006
  • In order to utilize the refrigerants condensation heat of condenser on the absorption chiller system, the solution cooling condenser(SCC) were proposed, which weak solution of absorber outlet use as a cooling water. As the UA of the solution cooling condenser increased, increasement of COP is about maximum 0.09 in occasion of single effect and is about maximum 0.08 in occasion of double effect series flow. In the case of heat exchanger efficiency is about 0.85, it's increments are 0.08 and 0.072, each. And solution cooling condenser is a more effective device in the single effect absorption system more than double effect system for the principle of operation. In order to increases the heat of solution cooling condenser, if reduce the flow rate of cooling water or the value of UA, it makes COP increase a little, but it brought COP decrease because of increasing the pressure of system.

  • PDF

HFC 및 탄화수소를 포함한 R-22 대체냉매의 성능평가 (Performance Evaluation of R-22 Alternative Refrigerants with Hydrofluorocarbon and Hydrocarbon)

  • 김창년;박영무;이병권;임종성
    • 설비공학논문집
    • /
    • 제12권3호
    • /
    • pp.315-324
    • /
    • 2000
  • R-410A, R-407C, and four refrigerant mixtures composed of R-32, R-l34a, R-l43a, R-l52a, R-600(butane), and R-600a(isobutane) were tested in an attempt to replace R-22 used in most of the residential air conditioners. The performance evaluation was carried out in a psychrometric calorimeter test facility using a residential spilt type air conditioner under the KS rating conditions. Except for the lubricant and hand-operated expansion valve, the other parts of the air conditioner were the same with the commercial system. Performance characteristics were measured; COP, capacity, compressor power, and VCR. R-410A was shown to have 5.5% higher COP and 3.5% lower capacity than R-22. R-32/134a/600a (42.8/ 46.0/11.2 wt%) mixture have the best performance among the four refrigerant mixtures composed of hydrofluorocarbon and hydrocarbon. This inixture have 3.0% lower COP and 1.6% lower capacity than R-22.

  • PDF

들기 자세에서 족저의 압력 분포와 압력중심 이동거리의 분석 (An Analysis of Plantar Foot Pressure Distribution and COP Trajectory Path in Lifting Posture)

  • 이명희;한진태;배성수
    • 한국산업보건학회지
    • /
    • 제19권1호
    • /
    • pp.25-29
    • /
    • 2009
  • The purpose of this study was to investigate the effect of two different lifting posture on the plantar foot pressure, force and COP(center of pressure) trajectory path during object lifting. Fourteen healthy adults who had no musculoskeletal disorders were instructed to lift with two postures(stoop and squat) and two object weights(empty box and 10 kg box). Plantar foot pressures, forces and COP trajectory path were recorded by the F-mat system(Tekscan, Boston, USA) during object lifting with barefoot. Plantar foot surface was defined as seven regions for pressure measurement; two toe regions, three forefoot regions, one midfoot region and one heel region. Paired t-test was used to compare the outcomes of peak pressure and maximum force with different two lifting postures and two object weights. Plantar peak pressure and maximum force under hallux was significantly greater in squat posture than stoop posture during the two different boxes lifting(p<.05). During the empty box lifting, maximum force under lessor toes was significantly less and plantar peak pressure under second metatarsal region was significantly greater in squat than stoop(p<.05). Maximum force under heel was significantly less in squat than stoop posture during 10kg box lifting(p<.05). Finally, COP trajectory path was significantly greater in squat than stoop(p<.05). These findings confirm that there are significantly change in the structure and function of the foot during the object lifting with different posture. Future studies should focus on the contribution of both structural and functional change to the development of common foot problems in adults.

The Effect of Tai Chi Training on the Center of Pressure Trajectory While Crossing an Obstacle in Healthy Elderly Subjects

  • Kim, Hyeong-Dong
    • 한국전문물리치료학회지
    • /
    • 제15권4호
    • /
    • pp.27-33
    • /
    • 2008
  • The purpose of this study was to investigate the changes of the center of pressure (COP) trajectory in healthy elderly subjects while crossing an obstacle before and after participation in Tai Chi training. Forty healthy elderly subjects participated either in a 12-week intervention of Tai Chi training or in a health education program. The participants were divided into two groups (the experimental group and the control group). Subsequently, the participants were pre- and post-tested on crossing over an obstacle from a quiet stance. Participants in the experimental group received Tai Chi training that emphasized the smooth integration of trunk rotation, a shift in weight bearing from bilateral to unilateral support and coordination and a gradual narrowing of the lower-extremity stance three times weekly. The participants in the control group attended a health education program one hour weekly and heard lectures about general information to promote health. Performance was assessed by recording the changes in the displacement of the COP in the anteroposterior (A-P) and mediolateral (M-L) directions using a force platform. Participants in the Tai Chi group significantly increased the A-P and M-L displacement of the COP after Tai Chi training (p<.05). No significant differences in the A-P and the M-L displacement of the COP between pre-testing and post-testing in the control group were found. This study has shown that participation in Tai Chi exercise increased the magnitude of the A-P and M-L displacement of the COP, thereby improving the ability of healthy elderly participation to generate momentum to initiate gait. These findings support the use of Tai Chi training as an effective fall-prevention program for the elderly.

  • PDF

지능형 영상 감시 환경에서의 개인정보보호를 위한 COP-변환 기반 메타데이터 보안 기법 연구 (A Study on COP-Transformation Based Metadata Security Scheme for Privacy Protection in Intelligent Video Surveillance)

  • 이동혁;박남제
    • 정보보호학회논문지
    • /
    • 제28권2호
    • /
    • pp.417-428
    • /
    • 2018
  • 지능형 영상감시 환경은 CCTV 등에서 실시간으로 수집한 영상데이터의 분석을 통해 영상 객체에 대한 다양한 정보를 추출하고 이를 기반으로 자동화된 처리를 가능하게 하는 기술이다. 그러나 지능형 영상감시 환경에서는 프라이버시 노출 문제가 발생할 수 있어 이에 안전한 대책이 필수적이다. 특히, 영상 메타데이터에는 빅데이터 기반으로 분석된 다양한 개인정보가 포함될 수 있어 높은 위험성을 안고 있으나, 효율성의 문제로 영상메타에 암호화 방식을 적용하는 것은 적절하지 않다. 본 논문에서는 영상메타를 안전하게 보호할 수 있는 COP-변환 기법을 제안한다. 제안한 방식은 메타 변환을 통하여 원본 메타정보를 복원할 수 없도록 하며, 변환된 데이터에 직접적으로 질의를 가능하게 하므로 영상 메타데이터 처리과정에서의 안전성과 효율성을 크게 높인다는 장점이 있다.