• Title/Summary/Keyword: cop

Search Result 1,228, Processing Time 0.025 seconds

Recognition of Machining Features on Prismatic Components (각주형 부품상의 가공 특징형상 인식)

  • 손영태;박면웅
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.6
    • /
    • pp.1412-1422
    • /
    • 1993
  • As a part of development of process planning system for mold die manufaturing, a software system is developed, which recognizes features and extracts parameters of the shape from design data produced by solid modeller. The recognized feature date is fed to process planning and operation planning system. Low level geometry and topology data from commercial CAD system is transformed to high level machining feature data which used to be done by using a dedicated design system. The recognition algorithm is applied to the design data with boundary representation produced by a core modeller ACIS which has object oriented open architecture and is expected to become a common core modeller of next generation CAD system. The algoritm of recognition has been formulated for 21 features on prismatic components, but the feature set can be expanded by adding rules for the additional features.

Potential Performance Enhancement of Dual Heat Pump Systems through Series Operation (히트펌프 직렬운전에 의한 성능 향상 가능성에 관한 연구)

  • Baik, Young-Jin;Kim, Min-Sung;Chang, Ki-Chang;Lee, Young-Soo;Kim, Hyeon-Ju
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.8
    • /
    • pp.797-802
    • /
    • 2012
  • In this study, the potential performance enhancement in a dual heat pump system through series operation was investigated by a comparison between the performance for parallel and series operation for a heating supply temperature of $60^{\circ}C$. To compare the performance of each configuration fairly, the heat transfer surface area of the heat exchangers was fixed. The inlet temperatures and the flow rates of the heat source and the load were also fixed. In addition, the heat transfer and pressure drop characteristics of the working fluids were considered to achieve a more realistic comparison. The results show that the heating coefficient of performance (COP) of the series configuration is approximately 5% higher than that of the parallel configuration under the simulation conditions considered in the present study.

Building Thesaurus for Science & Technology Domain Using Facets and Its Application to Inference Services (패싯(Facet)을 이용한 과학기술분야 시소러스 구축과 활용방안)

  • Hwang, Soon-Hee;Jung, Han-Min;Sung, Won-Kyung
    • Journal of Information Management
    • /
    • v.37 no.3
    • /
    • pp.61-84
    • /
    • 2006
  • In this paper, we proposed one of the methods for building thesaurus in Science & Technology domain and investigated its applicability as an inference service based on ontology. There exist as many building methods for thesaurus as its role and function, and actually many thesauri capable of ensuring the accuracy and efficiency in information search are being built by many experts. After examining the previous studies related to the principles of building thesaurus and relevant concept "facet", we focused on its characteristics and applied it to building thesaurus. The facet is classified into 2 categories, conceptual facet and relational facet. The latter contains 3 subcategories: category relational facet, attribute relational facet and thematic relational facet. The thesaurus for Science & Technology domain using facets can be applied as a web-based inference service. As a result, the three types of inference service, COP(Communities of Practice), Researcher Tracing and Research Map are provided by means of ontology, and can be applied for the Query Expansion.

Performance of Heat Pump Water Heater with Dual Condenser (2단 응축 히트펌프 온수시스템의 사이클 해석 및 성능분석)

  • Ryou, Y.S.;Kim, Y.J.;Kang, G.C.;Paek, Y.;Yun, J.H.;Kang, Y.G.;Lee, H.M.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.5 s.118
    • /
    • pp.423-429
    • /
    • 2006
  • The heat pump water heater developed in this research consisted of one evaporator, one compressor, 1st condenser, 2nd condenser, one expansion valve, one water tank, one recirculation circuit and etc. The performance of heat pump water heater was tested and analyzed. The quantities of output water changed linearly from 2380 to $660{\ell}/h$, and the output water temperature changed curvedly from 29.9 to $44.5^{\circ}C$ when the opening rate of recirculation valve changed from 0 to 100%. The COP of heat pump water heater increased from 3.0 to 3.8 when the quantities of output water changed from 660 to $2380{\ell}/h$. When the temperature distributions of water tank were measured during 50 minutes after turning on the heat pump, the temperature stratification by the level appeared apparently. When the inlet water temperature changed from 30 to$50^{\circ}C$, the output energy of heat pump hardly changed. The surface area of double pipe heat exchanger changed from 0.429 to $6.254m^2$ when the compressor capacity increased from 1.0 to 50.0 PS.

The Effect of Turning Training on Figure of 8 Tract on Stoke Patients' Balance and Walking (8자 모양 트랙을 이용한 방향전환 훈련이 뇌졸중 환자의 균형 및 보행에 미치는 영향)

  • Kim, Mi-Gan;Kim, Joong-Hwi;Park, Ji-Won
    • The Journal of Korean Physical Therapy
    • /
    • v.24 no.2
    • /
    • pp.143-150
    • /
    • 2012
  • Purpose: This study was intended to discover the effect of the turning training on figure of 8 tract on stroke patients' static and dynamic balance, as well as walking. Methods: A total of 42 stroke patients participated in this study. The training group was trained on the figure of 8 tract, while the control group was trained on the straight path for 30 minutes per day, for 4 weeks. Berg balance scale was used to measure the balance of the patients, before and after the training, and Good balance system was used to measure the sway speed and the distance of COG while standing. To measure the ability of walking, TUG and FSST were also used. Results: There were significant increases in the average score of Berg balance scale, in both groups after the training, and also significant difference between both groups were observed. The training group showed significant differences in the static balance ability, as well as anteroposterior and mediolateral sway speed. Further, there were significant increases in the dynamic balance ability, COP total distance, and TUG in both groups. The results showed more differences in comparing the control group with that of the training group. In FSST, there was no change in the control group, but there was a significant increase in the training group. Conclusion: Turning training on figure of 8 tract in stroke patients significantly increased the static and dynamic balance and walking ability. Based on the results, it can be seen that the training on the figure of 8 tract can influence the ability of balance and walking, which can lead to appropriate reactions to the change of environment and various tasks. Thus, it is assumed that turning training on figure of 8 tract as a means of improving the condition of stroke patients can be a meaningful program.

Analysis of GRF & Plantar Foot Pressure of Stepping Foot on Skilled & Unskilled Player's in the Soccer Instep Shoot (축구 인스텝 슈팅시 숙련자와 미숙련자의 지지발 지면반력과 족저압력 분석)

  • Kim, Dong-Seop;Lee, Joong-Sook;Jang, Young-Min
    • Korean Journal of Applied Biomechanics
    • /
    • v.22 no.1
    • /
    • pp.17-24
    • /
    • 2012
  • This study is for providing fundamental data of sport biomechanics in GRF & plantar pressure of stepping foot of skilled & unskilled players' at the soccer instep shooting moments. Wearing Pedar-x of Novel, the study has drawn the following conclusion after measuring and analyzing the impact on the GRF and plantar pressure of stepping foot at the instep shooting moments. First, maximum vertical GRF showed higher in the skilled group than in the unskilled group. The results showed significantly different. This study reached the conclusion that the players in the skilled group performed faster and stronger stepping foot motions that the ones in the unskilled(p<.01). Second, since the plantar pressure of the skilled group appeared significantly higher than that of the unskilled, it has brought us to the conclusion that the skilled group performed faster and stronger stepping foot motions than the unskilled group (p<.05). Third, at the moment of instep kicking, the skilled group's average maximum plantar foot pressure of stepping foot was higher than the unskilled. Though the difference was not statistically significant, it can be concluded that the skilled group performed faster and stronger stepping foot motions than the unskilled group(p>.05). Fourth, for the COP moving route of stepping foot while instep kicking, the skilled people performed accurate and strong shooting motions directly toward the target direction with stable postures, no matter how it's left, right, front or back.

Relationship between Dimensionless Leg Stiffness and Kinetic Variables during Gait Performance, and its Modulation with Body Weight

  • Hyun, Seung Hyun;Ryew, Che Cheong
    • Korean Journal of Applied Biomechanics
    • /
    • v.26 no.3
    • /
    • pp.249-255
    • /
    • 2016
  • Objective: This purpose of this study was to analyze the relationship between dimensionless leg stiffness and kinetic variables during gait performance, and its modulation with body weight. Method: The study sample consisted of 10 young women divided into 2 groups (Control, n=5 and Obese, n=5). Four camcorders (HDR-HC7/HDV 1080i, Sony Corp, Japan) and one force plate (AMTI., USA) were used to analyze the vertical ground reaction force (GRF) variables, center of pressure (COP), low limb joint angle, position of pelvis center and leg lengths during the stance phase of the gait cycle. Results: Our results revealed that the center of mass (COM) displacement velocity along the y-axis was significantly higher in the obese group than that in control subjects. Displacement in the position of the center of the pelvis center (Z-axis) was also significantly higher in the obese group than that in control subjects. In addition, the peak vertical force (PVF) and dimensionless leg stiffness were also significantly higher in the obese group. However, when normalized to the body weight, the PVF did not show a significant between-group difference. When normalized to the leg length, the PVF and stiffness were both lower in the obese group than in control subjects. Conclusion: In the context of performance, we concluded that increased dimensionless leg stiffness during the gait cycle is associated with increased velocity of COM, PVF, and the change in leg lengths (%).

Performance of Heat Pump System Using Underground Air as Heat Source (지하공기를 이용하는 농업시설용 난방시스템)

  • Kang, Youn-Ku;Ryou, Young-Sun;Kim, Young-Hwa;Sung, Moon-Seok;Kim, Jong-Koo;Jang, Jae-Kyoung;Lee, Hyoung-Mo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.587-589
    • /
    • 2009
  • The districts of underground geologic structure in Jeju island where underground air is distributed are lava cave, pyroclastic, open joint, and crushing zone. Such districts are identified to secure an enough airflow when air ventilation layer is to secure 25-35m in depth. In Jeju, Ground air is used for heating greenhouse and fertilizing natural $CO_2$ gas by suppling directly into greenhouse. But the heating method by suppling ground air into greenhouse directly bring about several problem. The occurrence of disease of the crops by high humidity is worried because the underground air which becomes discharge from underground air layer has over 90% relative humidity. The underground air is inadequate in heating for crops which need high temperature heating such as mangos, Hallbong and mandarin orange because the temperature of it is $15{\sim}18^{\circ}C$. Also There is worry where the ventilation loss becomes larger because the air pressure inside greenhouse is high by supplying underground air directly. In this study the heat pump system using underground air as heat source was developed and heating performance of the system was analysed. Heating COP of the system was 2.5~5.0 and rejecting heat into greenhouse and extracting heat from underground air were 40,000~27,000 kcal/h, 30,000~18,000 kcal/h respectively.

  • PDF

A Study on Significant Parameters for Efficient Design of Open-loop Groundwater Heat Pump (GWHP) Systems (개방형 지열시스템의 효율적 설계를 위한 영향인자에 대한 연구)

  • Park, Byeong-Hak;Joun, Won-Tak;Lee, Bo-Hyun;Lee, Kang-Kun
    • Journal of Soil and Groundwater Environment
    • /
    • v.20 no.4
    • /
    • pp.41-50
    • /
    • 2015
  • Open-loop groundwater heat pump (GWHP) system generally has benefits such as a higher coefficient of performance (COP), lower initial cost, and flexible system size. The hydrogeological conditions in Korea have the potential to facilitate the use of the GWHP system because a large number of monitoring wells show stable groundwater temperatures, shallow water levels, and high well yields. However, few studies have been performed in Korea regarding the GWHP system and the most studies among them dealt with Standing Column Well (SCW). Because the properties of the aquifer have an influence on designing open-loop systems, it is necessary to perform studies on various hydrogeological settings. In this study, the hydrogeological and thermal properties were estimated through various tests in the riverside alluvial layer where a GWHP system was installed. Under different groundwater flow velocities and pumping and injection rates, a sensitivity analysis was performed to evaluate the effect of such properties on the design of open-loop systems. The results showed that hydraulic conductivity and thermal dispersivity of the aquifer are the most sensitive parameters in terms of performance and environmental aspects, and sensitivities of the properties depend on conditions.

The Characteristics of Creep for Dispersion Strengthened Copper (분산강화 동합금의 Creep 특성)

  • Park, K.C.;Kim, G.H.;Mun, J.Y.;Choi, J.H.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.14 no.4
    • /
    • pp.220-227
    • /
    • 2001
  • The static creep behaviors of dispersion strengthened copper GlidCop were investigated over the temperature range of $650{\sim}690^{\circ}C$ (0.7Tm) and the stress range of 40~55 MPa (4.077~5.61 $kg/mm^2$). The stress exponents for the static creep deformation of this alloy was 8.42, 9.01, 9.25, 9.66 at the temperature of 690, 677, 663, and $650^{\circ}C$, respectively. The stress exponent, (n) increased with decreasing the temperature and became dose to 10. The apparent activation energy for the static creep deformation, (Q) was 374.79, 368.06, 361.83, and 357.61 kg/mole for the stress of 40, 45, 50, and 55 MPa, respectively. The activation energy (Q) decreased with increasing the stress and was higher than that of self diffusion of Cu in the dispersion strengthened copper. In results, it can be concluded that the static creep deformation for dispersion strengthened copper was controlled by the dislocation climb over the ranges of the experimental conditions. Larson-Miller parameter (P) for the crept specimens for dispersion strengthened copper under the static creep conditions was obtained as P=(T+460)(logtr+23). The failure plane observed for SEM slightly showed up transgranular at that experimental range, however, universally it was dominated by characteristic of the intergranular fracture.

  • PDF