• 제목/요약/키워드: cooling-off

검색결과 224건 처리시간 0.034초

IGBT를 이용한 인도 철도시스템 (Indian Railway Locomotives with IGBT Based Traction Control Converter)

  • 데버랜전고팔;노영환;김윤호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.1438-1444
    • /
    • 2007
  • Standard Gate Turn Off (GTO) Thyristor drive technology results in inhomogeneous turn-on and turn-off transients which in turn needs costly dv/dt and di/dt snubber circuits. Added to this GTO is bulky in size, needs external cooling, slower switching time etc. The development of high voltage Insulated Gate Bipolar Transistor (IGBT) have given new device advantage in the areas where they compete with conventional GTO technology. Indian Railway has developed first IGBT based traction converter and was commissioned in November 2006. Some of the supremacy of IGBT are smaller in size, no external cooling is required, built in power supply which enhances reliability, lower switching losses which leads to higher efficiency, reduced gate drive, high frequency operation in real time etc. These advantages are highlighted along with IGBT Traction system in operation.

  • PDF

열전소자를 이용한 BIPV 모듈의 냉각시스템 개발 (Cooling System Development of BIPV Module Using Thermoelectron)

  • 최정식;고재섭;정동화
    • 전기학회논문지
    • /
    • 제57권9호
    • /
    • pp.1555-1562
    • /
    • 2008
  • This paper presents a cooling system using thermoelectron for improving the output of BIPV module. The temperature characteristic in regard to improving the output of BIPV system has rarely been studied up to now but some researchers only presented the method using a ventilator. The cooling system efficiency of BIPV module applied to a ventilator mainly depends on the weather such as wind, insolation etc. Because the cooling system of BIPV module using a ventilator is so sensitive, that is being set off by wind speed at all time but is unable to operate in the NOCT(Nominal Operating Cell Temperature) which is able to make the maximum output. The paper presents the cooling system using thermoelectron so as to solve such problems. The temperature control of thermoelectron can be controlled independently in the outside environment because that is performed by micro-controller. The temperature control of thermoelectron, also, can be operated around NOCT through algorism of the temperature control. Therefore, outputs of the whole system increase and the efficiency rises. The paper demonstrates the validity of proposed method by comparing the data obtained through a experiment of the cooling method of BIPV using a ventilator and proposed thermoelectron.

고온가스 및 액체 바이패스 적용 용량가변 히트펌프의 성능특성에 관한 실험적 연구 (An Experimental Study on the Performance Characteristics of Hot-gas and Liquid Bypass Heat Pump Systems for Capacity Modulation)

  • 안재환;주영주;윤원재;강훈;김용찬
    • 설비공학논문집
    • /
    • 제25권3호
    • /
    • pp.137-142
    • /
    • 2013
  • A small air-conditioner or chiller for a constant temperature bath normally uses a constant speed compressor. The constant speed compressor is relatively inexpensive, but it uses on/off control for capacity modulation. The on/off control has several disadvantages, specifically energy loss and large temperature fluctuation. Continuous operation with a bypass system can be an alternative to on/off control, for capacity modulation. In this study, a heat pump system having a hot-gas bypass and a liquid bypass was adopted. The performance of the bypass-type heat pump was measured, by varying the bypass valve opening. The differences of the COP between the hot-gas bypass and the liquid bypass, in the cooling and heating operations, were within 2% and 1%, respectively. The liquid bypass showed a wider range of capacity control in the cooling operation but the hot-gas bypass showed a wider range of capacity control in the heating operation.

Characteristic analysis and condenser design of gas helium circulation system for zero-boil-off storage tank

  • Jangdon Kim;Youngjun Choi;Keuntae Lee;Jiho Park;Dongmin Kim;Seokho Kim
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제25권4호
    • /
    • pp.65-69
    • /
    • 2023
  • Hydrogen is an eco-friendly energy source and is being actively researched in various fields around the world, including mobility and aerospace. In order to effectively utilize hydrogen energy, it should be used in a liquid state with high energy storage density, but when hydrogen is stored in a liquid state, BOG (boil-off gas) is generated due to the temperature difference with the atmosphere. This should be re-condensed when considering storage efficiency and economy. In particular, large-capacity liquid hydrogen storage tank is required a gaseous helium circulation cooling system that cools by circulating cryogenic refrigerant due to the increase in heat intrusion from external air as the heat transfer area increases and the wide distribution of the gas layer inside the tank. In order to effectively apply the system, thermo-hydraulic analysis through process analysis is required. In this study, the condenser design and system characteristics of a gaseous helium circulation cooling system for BOG recondensation of a liquefied hydrogen storage tank were compared.

역전 유동층 내의 유동해석 및 슬러리아이스 생성에 관한 연구 (Flow pattern analysis and a study on formation of slurry ice in the reversing flow)

  • 오철;최영규
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2011년도 전기공동학술대회 논문집
    • /
    • pp.202-202
    • /
    • 2011
  • Thermal energy storage(TES) cooling system using cheaper electricity of off-peak time has been applied to relief a significant portion of the peak demand of electricity during the daytime in summer. Slurry ice type thermal energy storage cooling system is one kind of more efficient ice-thermal energy storage cooling system than Ice-on-Coil type or Encapsulated type TES cooling system, even though, which are more popular TES system. This study is experimented to observe flow pattern and formation of slurry ice in reversing flow to improve efficiency of heat transfer between fluid and freezing tube.

  • PDF

브라운관용 플런저 냉각표면의 온도분포 개선을 위한 연구 (A Study for Improvement of Temperature Distribution in Plunger Surface Cooling)

  • 곽경민;박지열;배철호
    • 한국정밀공학회지
    • /
    • 제25권3호
    • /
    • pp.126-133
    • /
    • 2008
  • The main objective of the present study is to achieve linear temperature distribution of cooling surface of plunger. K type thermocouples are attached at the surface of plunger to measure temperature. Nozzle and insulating material are inserted in the pin hole of the plunger for this study. Cooling water flow enters at one nozzle and leaves at three nozzles. Flow through nozzle can be activated in the pin hole, temperature of hot point around hole is decreased. Meanwhile, insulating material blocks off heat transfer, temperature of cold point around hole is increased. By combination of nozzle and insulation, heat transfer of hole is controlled effectively, as result its, temperature of plunger surface shows linear temperature distribution.

냉난방부하 절감을 위한 경사형 이중외피시스템의 성능연구 (A study on the efficiency of sloped type Double-skin System for the Curtailment of Heating/Cooling Load)

  • 안형준;김영탁;최창호;이현우
    • 한국태양에너지학회 논문집
    • /
    • 제24권4호
    • /
    • pp.77-87
    • /
    • 2004
  • BIPV or double skin applied to the surface of the building, power and thermal load cannot both be increased. In the case of BIPV, because it is applied to the facade, incident solar energy decreases and efficiency drops off. The system in this paper complements these disadvantages and aims to decrease the heating & cooling load by transforming solar energy to electronic and thermal energy. The research in this paper is about the applicability of the clear PV attached double-skin system. And the PV electronic generation and the factors that affect the heating & cooling load such as the daily radiation, sun shading ratio, heating & cooling load, daylight luminance and glare distributions in the building are simulated.

진공예냉에 의한 표고버섯의 선도 연장 (Freshness Keeping of Shiitake Mushroom by Vacuum Cooling)

  • 김병삼;남궁배;김의웅;김동철
    • 한국식품과학회지
    • /
    • 제27권6호
    • /
    • pp.852-859
    • /
    • 1995
  • Vacuum cooling were carried out for freshness keeping of shiitake mushroom. Shiitake mushroom was cooled within 30 minutes from $20.5^{\circ}C$ to $0.5^{\circ}C$ by vacuum cooling, and then temperature drop of $6.6^{\circ}C$ per weight loss of 1% was taken place during precooling. Weight loss, surface discoloration and softening were reduced by precooling. Judging from organoleptic properties such as cap opening, discoloration, texture and off-flavor, shelf-life of precooled mushroom was lengthed by 20% than that of non-treated mushrooms. Considering effect of packing material on freshness of shiitake mushroom after precooling, weight retention, hardness and organoleptic properties of mushroom packed with PVC wrap were superior to those packed in carton box.

  • PDF

가스터빈 프리스월 시스템의 외기 온도와 터빈 부하 조건에 따른 탈설계점 특성 분석 (Off-design Characteristics for Ambient Air Temperature and Turbine Load of Gas Turbine Pre-swirl System)

  • 박현우;이정수;조건환;조진수
    • 한국항공우주학회지
    • /
    • 제47권12호
    • /
    • pp.881-889
    • /
    • 2019
  • 가스터빈 이차 유로의 프리스월 시스템은 터빈의 효율을 높이고 소재의 수명을 연장하기 위해 설치되는 냉각 장치이다. 본 연구에서는 프리스월 시스템의 설계점을 기준으로 가스터빈 외기 온도와 터빈 부하 변화에 따른 탈설계점 분석을 수행하였다. 탈설계점에서 내부 유동의 특성을 분석하기 위하여 유량계수와 단열계수를 비교하였다. 터빈 부하 증가에 따라 시스템 내부 냉각 공기의 체적 유량이 증가하였고, 단열계수 또한 20% 터빈 부하와 비교하여 100% 터빈 부하에서 30.46% 상승하였다. 외기 온도가 증가할수록 질량 유량과 냉각 공기의 밀도는 감소하였지만 체적 유량은 상승하였으며, 결과적으로 프리스월 시스템 내부의 냉각 성능은 향상되었다. 프리스월 시스템 출구에서 -20℃ 외기 온도와 비교하여 55℃ 외기 온도의 단열계수는 14.82% 향상되었다.

철도차량용 전폐형 견인전동기 개발 및 시험 (Total Enclosed Type Traction Motor Development and Test for Rolling Stock)

  • 김정철;김봉철;박영호;한정수
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.3032-3036
    • /
    • 2011
  • Cooling type of traction motor for EMU in domestic is mostly an open type. Its system is a cooling air entered through air inlet cool down a traction motor and an hot air by traction motor get out air outlet. It is easy to cool it down but hard to maintain it. To improve an ability of maintenance, a total enclosed type traction motor is already developed and used in abroad, not an opne type. So we developed a total enclosed type traction motor which will be used in domestic and abroad EMU. We tried to reduce a weight and a size compared with the abroad one. In contrast with open type traction motors which cool off inside of motors, total enclosed motors cool down by cooling exterior frame of motors. In this case, cooling fins or air fan blowing to the exterior of motors are applied. The total enclosed type traction motor developed by us have two housing to block the foreign substance into inner of a motor and have two cooling fan to easy to reduce a heat happened at a coil. In this paper, design of a cooling structure of the total enclosed traction motor developed twice and performance verification through test will be discussed.

  • PDF