• 제목/요약/키워드: cooling source

검색결과 639건 처리시간 0.034초

지역 기후 특성에 따른 지열시스템의 도입경제성 차이에 관한 연구 (Feasibility study of ground source heat pump system according to the local climate condition)

  • 남유진
    • KIEAE Journal
    • /
    • 제14권4호
    • /
    • pp.127-131
    • /
    • 2014
  • The ground source heat pump (GSHP) system is a kind of the temperature differential energy system using relatively stable underground temperature as heat source of space heating and cooling. This system can achieve higher performance of system than it of conventional air source heat pump systems. However, its superiority of the system performance is different according to installation location or local climate, because the system performance depends on the underground condition which is decided by annual average air temperature. In this study, in order to estimate the feasibility of the ground source heat pump system according to the local climate, numerical simulation was conducted using the ground heat transfer model and the surface heat balance model. The case study was conducted in the condition of Seoul, Daejeon, and Busan, In the result, the heat exchange rate of Busan was 34.33 W/m as the largest in heating season and it of Seoul was 40.61 W/m as the largest in cooling.

CFD 모델을 이용한 열미로의 지중열원 활용에 관한 사례 연구 (Case Study on Application of Ground Heat Source in Thermal Labyrinth by CFD Model)

  • 민준기;남선영
    • 한국지열·수열에너지학회논문집
    • /
    • 제10권1호
    • /
    • pp.1-6
    • /
    • 2014
  • In order to evaluate the performance of ground heat source in thermal labyrinth on pre-heating in winter season and pre-cooling in summer season, the followings are made as a conclusion through case study of H project by using the weather data from Korea meteorological administration and CFD model. By making outdoor air inlet via ground heat source in thermal labyrinth for conduction, convection and etc., the temperature rise is $13.4^{\circ}C$as the effect of pre-heating in winter season. On the other hand, as the effect of pre-cooling in summer season, the temperature decrease is $7.2^{\circ}C$. The energy saving rate by the application of ground heat source in thermal labyrinth is 9.1%.

태양열 및 지중열원을 이용한 히트펌프 시스템의 최적이용법에 관한 연구 (Study on the Optimum Design of a Heat Pump System Using Solar and Ground Heat)

  • 남유진
    • 설비공학논문집
    • /
    • 제24권6호
    • /
    • pp.509-514
    • /
    • 2012
  • In this research, a heat pump system with a heat source network is suggested which utilizes solar heat and ground heat as heat source for cooling and heating. This paper describes the summary of the suggested system and the results of the annual energy simulation. The heating and cooling loads, the electric consumption and the COP were calculated by TRNSYS 16 and evaluated in the cases of different local conditions and different system compositions. In the results, the superiority of the suggested system has been quantitatively evaluated comparing with the conventional heat pump system using one heat source. Furthermore, it was more significant in cold climate, in which the heating COP was 146% increased compared the air source heat pump system, than it in subtropical climate, 119% increased.

지역냉방 공동주택 적정 냉방부하 산정 (The Estimation of Cooling Load for District Cooling in Apartment Buildings)

  • 김상훈;변운섭
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.643-649
    • /
    • 2008
  • The purpose of this study is to establish a standard for unit cooling load in central control type apartment applied district cooling. The model of unit household was selected. And the standard of coefficient of overall heat transmission, location of unit household, indoor air temperature, solar radiation & thermal conduction at window and interior load was selected, and region, expansion or non-expansion of balcony, pyeong type, azimuth, rate of window area was applied as parameter. And then cooling load simulation was performed. Based on the result of simulation, the synthetic district cooling load was presented for selecting heat source of apartment applied district cooling, and unit cooling load was analyzed according to design parameter.

  • PDF

축류 팬을 이용한 충돌제트 전자냉각 설계개념에 대한 연구 (Study on the Design Concept of Impinging Jet Electronics Cooling by Using Axial Fan)

  • 이찬;길현권
    • 한국유체기계학회 논문집
    • /
    • 제12권2호
    • /
    • pp.24-30
    • /
    • 2009
  • Flow and noise analyses are conducted for examining a new design concept of impinging jet electronics cooling, and the analysis results are compared with conventional electronics cooling techniques. For the application of impinging jet electronics cooling method, the present study considers the air duct where air is supplied by axial fan and air flow from the duct is impinged vertically onto the electronic component heat source. Applying CFD simulation technique and fan noise model to the present cooling scheme, the cooling performance of the impinging jet as well as the operation condition and the noise characteristics of fan are investigated for various impinging jet nozzle conditions and fan models. Furthermore, the impinging jet electronics cooling analysis results are compared with the conventional parallel-flow cooling scheme to give the design concept and criteria of impinging jet cooling method.

지하수 열원 복수정 지열 열펌프 시스템의 성능에 관한 실험적 연구 (An Experimental Study of Ground Water Source Two Well Type Geothermal Heat Pump System)

  • 임효재;권정태;김창업;공형진;박성구
    • 설비공학논문집
    • /
    • 제21권8호
    • /
    • pp.468-474
    • /
    • 2009
  • Ground water source heat pump system is the oldest one of the ground source heat pump systems. Despite of this, little formal design information has been available until recently. The important design parameters for open system are the identification of optimum ground water flow, heat exchanger selection and well pump. In this study, the capacity of 50 RT system of two well type ground water heat pump system was used. As a result, static water level was -7 m and the level during the heating operation was -32 m, cooling operation was -40 m. The initial static water level recovered within 48 hrs. The temperature of ground water is $15.6^{\circ}C$ for heating season and $16.2^{\circ}C$ for cooling season and does not depend on the outdoor temperature. Operation efficiency of the system shows that, COP 3.1 for heating and COP 4.2 for cooling.

지열히트펌프와 지역냉난방 시스템의 운영사례를 중심으로 경제성 비교분석 연구 (A Study of Comparative Economic Evaluation for the System of Ground Source Heat Pump and District Heating and Cooling:Focusing on the Analysis of Operation Case)

  • 이기창;홍준희;공형진
    • 설비공학논문집
    • /
    • 제28권3호
    • /
    • pp.103-109
    • /
    • 2016
  • The purpose of this study is to perform comparative economic evaluation for the systems of ground source heat pump (GSHP) and district heating and cooling (DHC) by focusing on the analysis of operation case of GSHP. The adapted research object is a public office building located in Seoul. The capacity of ground source pump is about 3,900 kW. Ground heat exchanger is closed loop type. The analysis period for life cycle cost is 30 years. Economic evaluation is assessed from the viewpoints of the following four parts: initial cost, energy cost, maintenance and replacement cost, and environment cost. The total life cycle cost of GSHP is approximately 8,447 million won. The cost of the DHC System is approximately 3,793 million won. The cost of the DHC is approximately 46% lower than GSHP system under the condition of current rate for GSHP and DHC.

지열원 열펌프 시스템의 에너지 생산량 모니터링 신뢰도 향상 방안 연구 (A Study on the Monitoring Methods for Energy Production in Ground Source Heat Pump System)

  • 강신형;이광호;도성록;최종민
    • 한국지열·수열에너지학회논문집
    • /
    • 제15권2호
    • /
    • pp.10-16
    • /
    • 2019
  • In this study, the present regulation of heat metering for the ground source heat pump was investigated. The ground source heat pump has been adopting the heat metering system used in the district heating system for estimating the heating and cooling energy production amount. The accuracy of the present heat metering systems for a water to water ground source heat pump is low, because the system for district heating has a relatively high temperature range comparing with the ground source heat pump operating conditions. Even though the heat amount for the building side should be measured, the heat absorption and extraction amount from or to the ground was measured for the water to air ground source heat pump due to the difficulty of estimating the air side heating and cooling capacity in the present regulation. It is highly recommended to validate the heat metering system to have reliability for the ground source heat pump and develop the system to be applicable water to air ground source heat pump.

선상 가열시 수냉 효과를 고려한 강판의 변형 추정에 관한 연구 (The Estimation of Curvature Deformation of Steel Plates in Water Cooling Process after Line Heating)

  • 황보혁;양박달치
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2006년 창립20주년기념 정기학술대회 및 국제워크샵
    • /
    • pp.209-212
    • /
    • 2006
  • Line heating with water cooling is generally adapted process in the shipyards for the forming hull surface. The purpose of this paper is to develop a model of thermal deformation in water cooling process after the line heating. In order to simulate the cooling process, heat transfer analysis was performed by assuming the effects of water cooling as a negative heat-source. Experiment for the line heating with water cooling was performed for 9 models of plates in order to verify the cooling model. By using the suggested model for the water cooling process, it could be observed that the present method predict the plate deformations in the line heating more accurately.

  • PDF

아파트 냉각탑의 소음 평가 및 대책 (Noise Evaluation and Measures of Cooling Tower at Apartment)

  • 이규배
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.1020-1023
    • /
    • 2004
  • Recently, Cooling tower are used the necessary element in a residential area and living space on the viewpoint of indoor temperature control. The purpose of this study is to assistance the comfortable environment and economical measures of noise transmission mechanism on tile cooling tower. The results show that noise evaluation interact the main factor of distance reduction and diffraction reduction. Noise criterion apply to the NC level and equivalent transmission loss about already the design of noise reduction.

  • PDF