• 제목/요약/키워드: cooling source

검색결과 635건 처리시간 0.029초

나노 실리카와 카본블랙이용 탄화열 반응으로 나노 SiC 합성 및 특성 (Synthesis of SiC Nanoparticles by a Sol-Gel Process)

  • 정광진;배동식
    • 한국재료학회지
    • /
    • 제23권4호
    • /
    • pp.246-249
    • /
    • 2013
  • Nano-sized ${\beta}$-SiC nanoparticles were synthesized combined with a sol-gel process and a carbothermal process. TEOS and carbon black were used as starting materials for the silicon source and carbon source, respectively. $SiO_2$ nanoparticles were synthesized using a sol-gel technique (Stober process) combined with hydrolysis and condensation. The size of the particles could be controlled by manipulating the relative rates of the hydrolysis and condensation reactions of tetraethyl orthosilicate (TEOS) within the micro-emulsion. The average particle size and morphology of synthesized silicon dioxide was about 100nm and spherical, respectively. The average particles size and morphology of the used carbon black powders was about 20nm and spherical, respectively. The molar ratio of silicon dioxide and carbon black was fixed to 1:3 in the preparation of each combination. $SiO_2$ and carbon black powders were mixed in ethanol and ball-milled for 12 h. After mixing, the slurries were dried at $80^{\circ}C$ in an oven. The dried powder mixtures were placed in alumina crucibles and synthesized in a tube furnace at $1400{\sim}1500^{\circ}C$ for 4 h with a heating rate of $10^{\circ}C$/min under flowing Ar gas (160 cc/min) and furnace cooling down to room temperature. SiC nanoparticles were characterized by XRD, TEM, and SAED. The XRD results showed that high purity beta silicon carbide with excellent crystallinity was synthesized. TEM revealed that the powders are spherical shape nanoparticles with diameters ranging from 15 to 30 nm with a narrow distribution.

냉각된 원전 2차계통수의 온도측정을 위한 비접촉식 광섬유 온도센서의 개발 (Development of a Fiber-optic Noncontact Temperature Sensor for Measuring the Temperature of Cooled Secondary Water in a Nuclear Power Plant)

  • 유욱재;이봉수;박병기;조영호
    • 한국산학기술학회논문지
    • /
    • 제11권5호
    • /
    • pp.1730-1734
    • /
    • 2010
  • 원전 2차계통수의 pH를 예측을 위해서는 샘플을 채취, 냉각시킨 후 pH를 측정하게 되는데 이 때 샘플의 온도는 pH를 변화시키는 중요한 요인이 된다. 본 연구에서는 할로겐화 은 광섬유를 이용하여 비접촉식 온도센서를 개발하였고, 열전쌍열을 이용하여 열원으로부터 방출되는 적외선을 측정하였다. 열원과 광섬유 끝단 사이의 거리 및 각도 변화에 따른 광섬유 온도센서의 출력신호를 분석하였으며, 광섬유 온도센서로 측정한 온도범위는 $25{\sim}60^{\circ}C$이다. 본 연구결과를 기초로 원전 2차계통수 pH 샘플의 온도를 측정하기 위해 할로겐화 은 광섬유를 이용한 비접촉식 온도센서의 개발이 가능할 것으로 기대된다.

저온영역에서 단열용기를 이용한 연료전지 모의 실험 (Simulation Experiment of PEMFC Using Insulation Vessel at Low Temperature Region)

  • 조인수;권오정;김유;현덕수;박창권;오병수
    • 한국수소및신에너지학회논문집
    • /
    • 제19권5호
    • /
    • pp.403-409
    • /
    • 2008
  • Polymer electrolyte membrane fuel cell (PEMFC) is very interesting power source due to high power density, simple construction and operation at low temperature. But it has problems such as high cost, improvement of performance, effect of temperature and initial start at low temperature. These problems can be approached to be solved by using experiment and mathematical method which are general principles for analysis and optimization of control system for heat and hydrogen detecting management. In this paper, insulation vessel and control system for stable operation of fuel cell at low temperature were developed for experiment. The constant temperature capability and the heating time at sub-zero temperatures with insulation control system were studied by using a heating bar of 60W class. PEMFC stack which was made by 4 cells with $50\;mc^2$ active area in each cell is a thermal source. Times which take to reach constant temperature by the state of insulation vacuum were measured at variable environment temperatures. The test was performed at two conditions: heating mode and cooling mode. Constant temperature capability was better at lower environment temperature and vacuum pressure. The results of this experiment could be used as basis data about stable operation of fuel cell stack in low temperature zone.

Computed Radiography 시스템에 $^{192}Ir$$^{75}Se$ 동위원소를 적용하여 촬영한 비파괴검사 영상 비교 (Comparison of Non-Destructive Testing Images using $^{192}Ir$ and $^{75}Se$ with Computed Radiography System)

  • 강상묵;최창일;이승규;박상기;김용균
    • Journal of Radiation Protection and Research
    • /
    • 제35권1호
    • /
    • pp.26-33
    • /
    • 2010
  • 비파괴검사 분야의 방사선 검사(RT) 방식은 image plate (IP)를 사용한 Computed Radiography(CR) 영상시스템의 도입에 따라 필름 방식의 아날로그 영상이 점차 디지털 영상으로 교체되고 있다. 비파괴검사에서 결함을 효과적으로 검출할 수 있는 영상의 품질은 촬영 조건, 영상획득매체, 사용 선원의 종류 및 촬영 거리, 검사체 두께등이 영향을 미친다. 본 논문에서는 비파괴 검사 분야에 적용할 수 있는 감마선원의 기본 특성을 조사하였고, FUJI사에서 개발한 CR 영상 시스템에 $^{75}Se$, $^{192}Ir$ 동위원소를 적용하여 영상을 획득하였다. 획득된 영상의 gray scale을 이미지 소프트웨어를 통해 추출한 후에 대조도 및 신호대잡음비를 계산하고 비교 분석하였다. 또한 투과도계를 이용한 비교 영상을 통하여 식별도를 분석하였다.

지역난방 공동주택의 에너지원별 원단위 사례분석 (Case Study on the Energy Consumption Unit of District Apartments)

  • 이왕제;강은철;이의준;오병칠;신우철
    • 설비공학논문집
    • /
    • 제26권10호
    • /
    • pp.474-480
    • /
    • 2014
  • This study investigated the total energy consumption and the energy consumption by type of 31 apartment complexes in Daejeon. The energy is supplied to the apartments from district heating, and can be divided into hot water, electricity, and gas. Hot water is used in for space heating and for domestic hot water (DHW), and electricity is used for plugs, cooling, ventilation, and public utilities (street lights, pumps, elevators, etc.). All gas supplied from district heating is used for cooking. As a result, the consumption unit of each energy source of independent dwelling areas was calculated to be $103.7kWh/m^2{\cdot}a$ ($15,692kWh/H{\cdot}a$) for thermal energy, $48.0kWh/m^2{\cdot}a$ ($4,646kWh/H{\cdot}a$) for electricity, and $10.5kWh/m^2a$ ($1,015kWh/H{\cdot}a$) for gas, so the entire consumption was calculated to be $162.3kWh/m^2{\cdot}a$ ($15,692kWh/H{\cdot}a$).

물-공기 지열 멀티형 열펌프 시스템 실증연구 (Verification Experiment of a Water-to-air Ground Source Multi-heat Pump System)

  • 김철우;김병국;이평강;임효재;강신형;최종민
    • 한국지열·수열에너지학회논문집
    • /
    • 제6권1호
    • /
    • pp.9-16
    • /
    • 2010
  • The aim of this study is to verify the performance of water-to-air multi-heat pump system with a vertical U-tube GLHX(U-tube system) and a double tube GLHX(double tube system), which were installed in a school building located in Asan. For analyzing the performance of the GSHP system, we monitored various operating da~ including the water temperature of inlet and outlet of the ground heat exchanger, mass flow rate, and power consumption. Daily average COP of the single U-tube system and the double tube system were 4.5 and 4.2 at cooling mode and were 3.5 and 3.8 at heating mode. As a result, We know that performance of water-to-air multi-heat pump unit is reliable at actual condition operated in a part load conditions for all day.

플러스에너지하우스 설계 및 에너지 성능 평가 (Design and Energy Performance Evaluation of Plus Energy House)

  • 김민휘;임희원;신우철;김효중;김현기;김종규
    • 한국태양에너지학회 논문집
    • /
    • 제38권2호
    • /
    • pp.55-66
    • /
    • 2018
  • South Korea aims to shift the 20 percent of electricity supplement from the fossil fuel including the nuclear to renewable energy systems by 2030. In order to realize this agenda in the buildings, the plus energy house is necessary to increase the renewable energy supplement beyond the zero energy house. This paper suggested KePSH (KIER Energy-Plus Solar House) and energy performance of house and renewable energy systems was investigated. The KePSH has the target of generating 40% surplus energy than the conventional house energy consumption. The plus energy house is the house that generates surplus energy from the renewable energy sources than that consumes. In order to minimize the cooling and heating load of the house, the shape design and passive parameters design were conducted. Based on the experimental data of the plug load in the typical house, the total energy consumption of the house was estimated. This paper also suggested renewable energy sources integrated HVAC system using air-source heat pump system. Two cases of renewable energy system integration methods were suggested, and energy performance of the cases was investigated using TRNSYS 17 program. The results showed that the BIPV (building integrated photovoltaic) system (i.e., CASE 1) and BIPV and BIST system (i.e., CASE 2) shows 42% and 29% of plus energy rate, respectivey. Also, CASE 1 can generate 59% more surplus energy compared with the CASE 2 under the same installation area.

할로겐 램프 열원을 이용한 초전도성 $Bi_2Sr_2CaCu_2O_8$ Fiber의 Float Zone 성장 (Float Zone Growth of Superconduction $Bi_2Sr_2CaCu_2O_8$ Fiber with Halogen Lamp)

  • 김철진;정준기
    • 한국결정학회지
    • /
    • 제7권2호
    • /
    • pp.147-155
    • /
    • 1996
  • 할로겐 램프를 열원으로 이용하는 결정성장장치인 부유대역융로를 제작하여 고온초전도체 Bi2Sr2CaCu2O8의 성장에 이용하였다. 제작된 결정성장장치는 할로겐 램프를 초점에 위치시키기 위한 holder unit, 1kW의 할로겐 램프로서 최대 1800℃까지 사용이 가능한 image furnace, 냉각장치, 원료 물질을 공급하는 feeding unit, 성장된 단결정을 인상하는 pulling unit, 그리고 2mm/hr - 40mm/hr의 속도로 상하 이동 및 15rpm -120rpm의 회전이 가능한 제어부 등으로 구성되었다. 300W의 할로겐 램프를 이용하여 Bi2Sr2CaCu2O8 fiber를 성장시켰으며 성장된 fiber는 XRD, SEM, EDS 등으로 분석하였다. 성장조건은 공기분위기에서 성장속도 3∼4mm/hr, 상·하부축 회전속도 20∼25 rpm이었으며 성장된 fiber는 Bi2Sr2CaCu2O8 기지 내에 (Sr,Ca)CuO2 및 (Sr,Ca)2CuO3의 2차상을 포함하고 있었다.

  • PDF

포항 북부 내연산응회암의 흐름지시자와 측방점이로부터 유향 결정 (Determination of Flow Direction from Flow Indicators and Lateral Grading in the Naeyeonsan Tuff, Northern Pohang, Korea)

  • 조남식;황상구
    • 암석학회지
    • /
    • 제26권2호
    • /
    • pp.153-163
    • /
    • 2017
  • 내연산응회암은 포항 북부의 화산암류에서 하나의 냉각단위로 구별되는 층서단위이다. 이 응회암은 사장석, 석영, 각섬석 등의 결정편, 부석과 샤아드의 유리질편, 데사이트, 유문암, 사암, 셰일 등의 암편으로 구성된다. 이들은 그 입도에 의하면 대부분 라필리응회암에 속하고 구성원에 의하면 파리질 응회암에 속한다. 대부분 부석과 샤아드들은 용결작용과 편평화로 인한 용결엽리를 발달시키며 화쇄류에 의한 흐름지시자를 보여준다. 우리는 이 내연산응회암에서 흐름지시자로서 부석, 암편들의 정향배열에 의한 유상선구조과 와상배열로부터 이동패턴, 암편과 부석들의 평균최대입경에 의한 등입경도로부터 측방점이를 알아냈다. 이러한 이동패턴과 측방점이에 의하면 이 응회암을 집적시킨 화쇄류의 가능공급지가 남동쪽에 있었던 것으로 해석된다.

C-dump Converter에 의한 차량용 SRM 구동 시스템의 고성능제어 (High Performance Control of SRM Drive System for Automobiles by C-dump Converter)

  • 김도군;윤용호;이태원;원충연;김영렬
    • 전력전자학회논문지
    • /
    • 제8권6호
    • /
    • pp.534-542
    • /
    • 2003
  • 현재 차량에 사용되는 전동기는 대부분 직류전동기로, 12V또는 24V 밧데리 전원으로 구동되는 엔진 냉각 팬, 오일 펌프 및 공조시스템 등에 적용되고 있다 그러나 직류전동기의 경우 효율, 수명, 내구성에 취약한 단점을 지니고 있다. 따라서, 자동차용 전동기로써 구조가 간단하고 내구성이 우수한 SRM(Switched Reluctance Motor)의 관심이 매우 높아지고 있다. SRM을 차량용으로 사용하기 위해서는 고성능 제어와 12V 전윈 구동에 모두 우수한 성능을 갖는 구동 컨버터의 선정이 매우 중요하다. 여러 종류의 구동 컨버터는 각각의 장단점을 갖고 있어, 차량에 적용시 여러 가지 제약 조건이 따른다. 일반적으로 많이 사용되고 있는 비대칭 컨버터는 제어성능이 우수하지만, 각 상당 스위치가 가장 많이 필요하고, 상당 2개의 스위치에 의한 전압강하가 발생하는 단점을 지니고 있어, 차량의 12V 전원에는 부적절하다 구조가 간단하고, 스위치 수가 적은 컨버터로 차량의 환경과 여러 요구조건을 충족시킬 수 있는 컨버터로써 Modified C-dump 컨버터와 Energy efficient C-dump 컨버터를 선정하였다. 제안된 두 컨버터를 시뮬레이션과 실험을 통해 비교 검토하여, 차량용 SRM 구동 컨버터로써 Energy efficient C-dump 컨버터의 우수한 제어성능을 증명하였다.