• 제목/요약/키워드: cooling rates

검색결과 503건 처리시간 0.027초

데이터센터용 멀티 외기이용 냉방시스템의 지역별 에너지 절감효과에 대한 연구 (A Study on the Regional Energy Conservation Effects of a Multi-stage Outdoor Air Enabled Cooling System in a Data Center)

  • 박문기;장현재
    • 한국태양에너지학회 논문집
    • /
    • 제37권1호
    • /
    • pp.71-80
    • /
    • 2017
  • A Data center houses a large number of server computers, storage and etc in racks. With the rapid increase of heat generation rates per rack in a data center, energy consumption rates for cooling have been increased year by year. In this study, energy conservation effects of a MOA (multi-stage outdoor air enabled) cooling system in a data center has been investigated when it is applied to 5 different locations, Korea. As results, Energy conservation effects of the MOA cooling system was achieved at about 20% to 30%. Humidifier operation time was 40 to 55 days when supply air temperature was maintained at 13, and humidity condition was kept within the allowed range even though humidifier was off. Furthermore, humidification was not needed when supply air temperature was maintained at $25^{\circ}C$. In selected 5 locations in Korea, the difference of regional climatic conditions affected no more than 5% in cooling energy consumption rates.

엔진 및 차량냉각계의 냉각수유량 측정실험 및 계산방법에 관한 연구 (A Study of the Experiment and the Calculation Method on the Coolant Flow Rate of Engine and Vehicle Cooling System)

  • 오창석;유택용;이은현;최재권
    • 한국자동차공학회논문집
    • /
    • 제7권6호
    • /
    • pp.1-7
    • /
    • 1999
  • In this study, the prediction method of coolant flow rates has been developed and applied to an engine and vehicle cooling system. The flow rate passing through each component of the system is very important parameter to evaluate the heat transfer process form the combustion gas to the coolant and the heat rejection process form the radiator /heater to the ambient air. However, the present study reveals that the measurement using the flowmeter fails to give practical flow rates due to its additive resistance. In contrast, the present method which uses the parallel and serial relationship of flow resistance proved to be a good tool to predict the real flow rates. It can be also used to design the cooling system in the incipient stage of engine/vehicle development . The procedure was coded to the computer program so as to use it flexibly and, in the future, to expand it into an independent design tool of the whole cooling system including the heat release and rejection.

  • PDF

열교환기를 사용한 냉각/재가열 장치의 에너지 절감에 관한 연구 (A Study on the Energy Saving of Cooling/Reheating System Using Heat Exchanger)

  • 김진혁;유성연;최양규
    • 설비공학논문집
    • /
    • 제22권7호
    • /
    • pp.482-491
    • /
    • 2010
  • In conventional air-handling units, when the circulated air from the air-conditioned space pass through the cooling coil, the air is over-cooled to eliminate the moisture as well as to decrease the temperature. The purpose of this study is to estimate the thermal performance and energy saving of the cooling/reheating system using heat exchanger which can save both cooling energy and reheating energy by exchanging heat between the cooled air and reheated air. The energy balance equations to estimate the state of the air for each components were provided and the heat transfer rates and the energy saving rates for the system were calculated from the equations. The results showed that the energy saving was up to 40% under present conditions, and saving rates were significantly affected by the air velocity, inlet conditions and the effectiveness of heat exchanger.

Al-Si합금(合金)의 CFR 과 MDE 에 미치는 냉각속도(冷却速度)의 영향(影響) (The Influence of Cooling Rates on the CFR and the MDE of Al-Si Alloys.)

  • 권혁무;김수영
    • 한국주조공학회지
    • /
    • 제4권4호
    • /
    • pp.14-19
    • /
    • 1984
  • In order to clarify the solidification mechanism of Al-Si alloy, Mushy Degree of Eutectic Solidification (MDE) and Centerline Feeding Resistance (CFR) were systematically studied by casting with various compositions of $Al-(6{\sim}18%)$ Si alloys into several kinds of molds having different cooling rates. The results are as follows: 1. CFR% increases slightly as solute concentration increases, but decreases remarkably as the cooling rate of the mold increases, that is, the composition dependence of the alloys has more effect on the change of CFR% than that of the mold cooling rate. 2. The composition dependence of MDE value has the same tendency as that of Degree of Eutectic Solidification (DES). MDE value within the range of hypereutectic composition is larger than that of hypoeutectic and it represents the maximum value at eutectic composition. The higher the cooling rate is, the less the MDE value is.

  • PDF

3차원 방열기 모델을 이용한 엔진냉각 해석 (An Analysis of Engine Cooling using a Three-dimensional Radiator Model)

  • 이영림
    • 한국자동차공학회논문집
    • /
    • 제9권4호
    • /
    • pp.10-17
    • /
    • 2001
  • The performance of a radiator is generally determined using a wind tunnel, in which the air velocity is uniform. However, when it is installed in a car, the distribution of the air velocity becomes nonuniform due to front-end openings, cross members, and horns etc., resulting in lower performance. In this study, several underhood flow simulations have been first performed to get flow rates and velocity distributions over the radiator. Secondly heat release rates are calculated by both a performance curve and a radiator model. Finally, using an engine cooling system simulator, radiator-top-tank temperature is predicted and the variations of heat release rate and radiator-top-tank temperature with nonuniformity of air velocity distributions are analyzed. The results show that the current engine cooling model successfully accounts for the nonuniformity effects that should be considered for higher accuracy in predicting engine cooling performance.

  • PDF

고망간 주강품의 열처리시 탄화물 석출방지를 위한 임계 냉각속도에 관한 연구 (A Study on the critical cooling rate to avoid carbide precipitation in austenitic manganese steels during quenching)

  • 김정태;곽시영;최정길;홍준표
    • 열처리공학회지
    • /
    • 제12권3호
    • /
    • pp.206-214
    • /
    • 1999
  • The effect of cooling rate on carbide precipitation during quenching of austenitic manganese steel was investigated by optical microscopy, image analyzer and numerical analysis. A computer program based on the finite difference method for analyzing heat treatment processes was developed in order to evaluate cooling rates and the possibility of carbide precipitation during quenching. The area ratio of carbide precipitated in the austenite matrix was measured by the image analyzer, and used to determine the critical point of carbide precipitation. Temperature-dependent critical cooling rates at the critical points were calculated using the present simulation program, The calculated results showed a good agreement with the experimental ones.

  • PDF

광섬유 고속생산용 헬륨 주입식 유리섬유 냉각공정에 대한 열유동 해석 (THERMO-FLUID ANALYSIS ON THE HELIUM INJECTION COOLING OF GLASS FIBER FOR HIGH SPEED OPTICAL FIBER MANUFACTURING)

  • 오일석;김동주;곽호상;김경진
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2011년 춘계학술대회논문집
    • /
    • pp.92-95
    • /
    • 2011
  • In manufacturing optical fibers, the process starts with the glass fiber drawing from the heated and softened silica preform in the furnace, and the freshly drawn glass fiber is still at high temperature when it leaves the glass fiber drawing furnace. It is necessary to cool down the glass fiber to the ambient temperature before it then enters the fiber coating applicator, since the hot glass fiber is known to cause several technical difficulties in achieving high quality fiber coating. As the fiber drawing speed keeps increasing, a current manufacturing of optical fibers requires a dedicated cooling unit with helium gas injection. A series of three-dimensional flow and heat transfer computations are carried out to investigate the effectiveness of fiber cooling in the fiber cooling unit. The glass fiber cooling unit is simplified into the long cylindrical enclosure at which the hot glass fiber passes through at high speed, and the helium is being supplied through several injection slots of rectangular shape along the cooling unit. This study presents and discusses the effects of helium injection rates on the glass fiber cooling rates.

  • PDF

발효조의 냉각량 연속 측정 및 이를 이용한 유가배양제어 (On-line Measurement of Cooling Rate of a Fermenter and its Application for Fed-batch Control)

  • 허원;홍건표
    • KSBB Journal
    • /
    • 제18권5호
    • /
    • pp.418-423
    • /
    • 2003
  • 발효조의 냉각수 공급 제어 신호와 냉각수의 유출입 지점의 온도를 온라인으로 측정하여 이 값들로부터 냉각량을 추정할 수 있는 실험식을 얻었다. 회분식 배양을 통하여 냉각량이 온라인으로 측정될 수 있음을 확인하였고 기질의 재투입시 냉각량의 변화를 통하여 유가배양의 제어변수로 활용할 수 있음을 점검하였다. 미리 프로그램된 목표 냉각량의 증가곡선에 따라 냉각량이 증가되면서 세포가 자라도록 유가배양을 실시하였다. 본 연구를 통하여 냉각량의 온라인 측정방법을 제시하였고 이를 유가배양 제어변수로 활용하여 세포의 성장속도를 조절할 수 있음을 보였다.

The effect of different cooling rates and coping thicknesses on the failure load of zirconia-ceramic crowns after fatigue loading

  • Tang, Yu Lung;Kim, Jee-Hwan;Shim, June-Sung;Kim, Sunjai
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권3호
    • /
    • pp.152-158
    • /
    • 2017
  • PURPOSE. The purpose of this study was to evaluate the influence of different coping thicknesses and veneer ceramic cooling rates on the failure load of zirconia-ceramic crowns. MATERIALS AND METHODS. Zirconia copings of two different thicknesses (0.5 mm or 1.5 mm; n=20 each) were fabricated from scanning 40 identical abutment models using a dental computer-aided design and computer-aided manufacturing system. Zirconia-ceramic crowns were completed by veneering feldspathic ceramics under different cooling rates (conventional or slow, n=20 each), resulting in 4 different groups (CONV05, SLOW05, CONV15, SLOW15; n=10 per group). Each crown was cemented on the abutment. 300,000 cycles of a 50-N load and thermocycling were applied on the crown, and then, a monotonic load was applied on each crown until failure. The mean failure loads were evaluated with two-way analysis of variance (P=.05). RESULTS. No cohesive or adhesive failure was observed after fatigue loading with thermocycling. Among the 4 groups, SLOW15 group (slow cooling and 1.5 mm chipping thickness) resulted in a significantly greater mean failure load than the other groups (P<.001). Coping fractures were only observed in SLOW15 group. CONCLUSION. The failure load of zirconia-ceramic crowns was significantly influenced by cooling rate as well as coping thickness. Under conventional cooling conditions, the mean failure load was not influenced by the coping thickness; however, under slow cooling conditions, the mean failure load was significantly influenced by the coping thickness.

생쥐배아의 동결보존에 관한 실험적 연구 (The Experimental Study on Cryopreservation of Mouse Embryo)

  • 이여일;권영숙;박현정
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제28권1호
    • /
    • pp.55-63
    • /
    • 2001
  • Objectives: This study was carried out to evaluate the effects of embryonic stage, cryoprotectant, and freezing-thawing method on the rates of survival and development of the cryopreserved mouse early embryo and finally to establish the cryopreservation method of surplus embryos obtained during assisted reproductive technology (ART). Materials and Methods: Two to eight cell embryos were obtained from oviducts of mated $F_1$ hybrid female mice superovulated by pregnant mare's serum gonadotropin (PMSG) and human chorionic gonadotropin (hCG). Two-step 1,2-propanediol (PROH), dimethylsulfoxide (DMSO) and 4-step PROH DMSO were used as cryoprotectant and dehydration and rehydration method of embryos, and slow-cooling or rapid-cooling method was used as frozen program. The survival rates of embryos were measured after thawing and rehydration, and the developmental rates of embryos were compared and observed during culturing embryos for 24, 48, 72, 96 hrs. Results: As for the survival and development rates of embryos according to embryonic stage, the survival rate of 2 cell stage in PROH and DMSO was significantly higher than 4-8 cell (64.5% versus 62.1 %,79.7% versus 73.2%) (p<0.01, p<0.01), but the development rates of 4-8 cell embryos in PROH and DMSO were significantly higher than 2 cell embryos for whole culture period (p<0.01) and the development rates of 4-8 cell embryos in PROH were significantly higher than 2 cell embryos in DMSO (p<0.01). As for the survival and development rates of embryos according to cryoprotectant, the survival rate of 2 cell embryo in DMSO was significantly higher than that in PROH (74.4% versus 64.5%) (p<0.01), whereas the development rate of embryos was not differ till 24 hrs. The developmen1 rate from morular to hatching blastocyst, however, was significantly higher in PROH than in DMSO during 48 hr (p<0.01). The survival rate of 4-8 cell embryo was 62.1% in PROH and 73.2% in DMSO. The development rates of embryo in PROH were significantly higher for whole culture periods (p<0.01, 0.05). In respect to the effect of freezing and thawing program on the survival and development rates of embryos, method of slow cooling and rapid thawing was more effective than that of rapid cooling and rapid thawing. Conclusions: The survival rate of embryo in 2 cell stage was higher than in 4-8 cell stage, and PROH appears more effective cryoprotectant than DMSO because PROH showed better development rates of embryos in 2 and 4-8 cell stage. Moreover, slow cooling and rapid thawing method was considered as the best cryopreservation program.

  • PDF