• 제목/요약/키워드: cooling pipes

검색결과 127건 처리시간 0.024초

Desktop PC CPU Cooling System Design and Analysis

  • 최지훈;유정현;서민환;강신제;김천주
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.601-604
    • /
    • 2008
  • Desktop PC CPUs have been significantly required to be the necessity of thermal management while they have satisfied the extensive data and graphic processing requirements. So the cooling systems assembled with heat pipes embedded in a metal cooling plate, and fins are widely used in the desktop PC markets. Due to a number of demands such as the confined space of desktop PCs, higher heat density of CPUs, and acoustic noise, however, there is the main drive to improve continuously cooling systems. This paper presents the flow and thermal behavior of the cooling system by using the computational fluid dynamics(CFD) code.

  • PDF

Early-age thermal analysis and strain monitoring of massive concrete structures

  • Geng, Yan;Li, Xiongyan;Xue, Suduo;Li, Jinguang;Song, Yanjie
    • Computers and Concrete
    • /
    • 제21권3호
    • /
    • pp.279-289
    • /
    • 2018
  • Hydration heat and thermal induced cracking have always been a fatal problem for massive concrete structures. In order to study a massive reinforced concrete wall of a storage tank for liquefied natural gas (LNG) during its construction, two mock-ups of $0.8m{\times}0.8m{\times}0.8m$ without and with metal corrugated pipes were designed based on the actual wall construction plan. Temperature distribution and strain development of both mock-ups were measured and compared inside and on the surface of them. Meanwhile, time-dependent thermal and mechanical properties of the concrete were tested standardly and introduced into the finite-element (FE) software with a proposed hydration degree model. According to the comparison results, the FE simulation of temperature field agreed well with the measured data. Besides, the maximum temperature rise was slightly higher and the shrinkage was generally larger in the mock-up without pipes, indicating that corrugated pipes could reduce concrete temperature and decrease shrinkage of surrounding concrete. In addition, the cooling rate decreased approximately linearly with the reduction of heat transfer coefficient h, implying that a target cooling curve can be achieved by calculating a desired coefficient h. Moreover, the maximum cooling rate did not necessarily decrease with the extension of demoulding time. It is better to remove the formwork at least after 116 hours after concrete casting, which promises lower risk of thermal cracking of early-age concrete.

현장 열성능 평가시험을 통한 강관 에너지파일의 적용성 평가 (Evaluation of Applicability of Steel-pipe Energy Piles Through Thermal Performance Test (TPT))

  • 이석재;최항석
    • 한국지열·수열에너지학회논문집
    • /
    • 제18권2호
    • /
    • pp.1-9
    • /
    • 2022
  • A novel steel-pipe energy pile is introduced, in which the deformed rebars for main reinforcing are replaced with steel pipes in a large diameter cast-in-place energy pile. Here, the steel pipes act as not only reinforcements but also heat exchangers by circulating the working fluid through the hollow hole in the steel pipes. Under this concept, the steel-pipe energy pile can serve a role of supporting main structures and exchanging heat with surrounding mediums without installing additional heat exchange pipes. In this study, the steel-pipe energy pile was constructed in a test bed considering the material properties of steel pipes and the subsoil investigation. Then, the thermal performance test (TPT) in cooling condition was conducted in the constructed energy pile to investigate thermal performance. In addition, the thermal performance of the steel-pipe energy pile was compared with that of the conventional large diameter cast-in-place energy pile to evaluate its applicability. As a result, the steel-pipe energy pile showed 11% higher thermal performance than the conventional energy pile along with much simpler construction processes.

히이트파이프 다발을 이용한 냉축열시스템에서의 대류열전달에 관한 연구 (A Study on the Convective Heat Transfer in a Regenerative Ice Energy System by a Bundle of the Heat-pipes.)

  • 권형정;김경석;김경근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제14권4호
    • /
    • pp.57-66
    • /
    • 1990
  • In the design of an electric power plant, the capacity to meet the peak load demand is one of the important factors to be considered. This peak load usually occurs when the most of the cooling air conditioning systems are being operated during daytime in summer season, which inevitably entails the construction of an additional electric power plant. This study is aimed to carry out a basic experiment for the development of a cooling air conditioning system using the ice energy by the surplus electric power during the night-time. The experimental apparatus consists of four major parts; (1) the heating section consisting of the air duct and I.D. fan, (2) the cold section with the ice chamber, (3) the bundle of heat pipes made in a form of the staggered arrangement with ${C_y}/{d_o}$=2.0 and ${C_x}/{d_o}$=1.73, (4) the refrigerator system to cool down the ice chamber. This study involves an intensive experiment concerning the convective heat transfer of the air flow surrounding the bundle of heat pipes. This major experimental parameters are the amount of working fluid, the velocity of air and the working temperature. The major findings of the present study are as follows; (1) The optimum amount of the working fluid necessary for the horizontal heat pipes is much more than that for the vertical type. (2) The convective heat transfer coefficients of the air are coincided with the empirical equations of Grimson and ${\breve{Z}ukauskas}$. (3) The equation of the mean heat transfer coefficient obtained in the present study is ${N_um}=0.32 {Re_max^{0.63}}$.

  • PDF

매스 콘크리트 구조물의 파이프 쿨링에 의한 냉각효과 (The Cooling Effect of Pipe Cooling in Mass Concrete Structures)

  • 오병환;신경준;차수원
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.299-304
    • /
    • 1999
  • Cracking of concrete is one of the main issues of structural design next to ensuring the load-bearing capacity. Thermal cracking is a recurring concern in the production of concrete structures in particular when large, massive structures are considered. Thremal stresses arise from the differential temperature distribution either within s sturcture or between newly cast sectons and adjoining older parts. There are many different methods of reducing thermal stresses. A method often used for reducing temperature within a structure, is to cool the inner core with embedded cooling pipes. In this study, finite element method is employed for thermal analysis of concrete structures. To calculate water temperature variation in pipe, the conservation of thermal energy in internal flow was adopted. The cooling effect of pipe cooling is studied with several factors like convective coefficient, water temperature, concrete heat characteristics

  • PDF

수평 2열 원통관 주위의 동결형상에 관한 연구 (Experimental Study for Ice Formation around Two Horizontal Circular Tubes)

  • 윤정인;김재돌;도요후미 카토;오후규
    • 설비공학논문집
    • /
    • 제7권1호
    • /
    • pp.89-97
    • /
    • 1995
  • Experimental study was performed for free convection and ice formation around two horizontal circular tubes which were placed vertically. Temperature and velocity distributions were visualized with real time holographic interferometry technique and tracer method. When water was cooled, super cooled region was formed around cooling pipe. It was found that flow induced by free convection always directed downwards when the coolant temperature was low, while it directed upwards when the coolant temperature was comparably high though it directed downwards initially. Flow phenomena with free convection were investigated in detail with varying cooling rate and length between cooling pipes. And growing process of dense ice was also investigated. Dendritic ice is suddenly formed within a supercooled region, and a dense ice layer begins to develop from the cooling wall.

  • PDF

빙축열 냉방 시스템의 동적 시뮬레이션 (Dynamic simulation of the ice storage cooling system)

  • 한도영;이준호
    • 설비공학논문집
    • /
    • 제11권6호
    • /
    • pp.815-823
    • /
    • 1999
  • A dynamic simulation program may be used for the development of effective control algorithms for the ice storage cooling system. Simplified effective dynamic models for an ice-on-coil type storage tank, a screw chiller, a water-to-air heat exchanger, three way valves, pipes, pumps, temperature sensors, and controllers were developed. And a dynamic simulation program for the ice storage cooling system was developed by using these dynamic models. Control algorithms for the full storage system were also selected and analyzed in order to show the effectiveness of these models. From the simulation results, it may be concluded that the simulation program developed in this study can be effectively used for the development of improved control algorithms for the ice storage cooling system.

  • PDF

공동주택의 단열 및 차양에 따른 구체축열시스템 냉방성능 평가 (Evaluation on Cooling Performance of Thermally Activated Building System by Insulation and Shading Conditions in Apartments)

  • 유미혜;여명석;이유지;정웅준;박상훈;김광우
    • 한국주거학회논문집
    • /
    • 제23권2호
    • /
    • pp.107-114
    • /
    • 2012
  • Thermally Activated Building System(TABS) is a radiant heating and cooling system which uses structures as thermal storage by embedding pipes in a concrete slab. Using TABS as the cooling system in residential buildings can reduce energy consumption and peak loads. But the ratio of cooling loads handled by TABS is low in the residential buildings which are significantly influenced by outside condition because condensation and over-cooling may occur. However, recent interest on energy-saving buildings is increasing and new residential buildings are expected to be less influenced by outside with high-insulation and shading. In such residential buildings, the heating and cooling loads and the range of load changes reduce. So the ratio of loads handled by TABS can increase. Therefore, this research investigates the cooling performance and energy performance of TABS in the residential buildings with less influence from outside using the simulation.

매스콘크리트 시험체의 수화열 해석 및 실험 (Numerical Simulation of Temperature and Stress Distribution in Mass Concrete with pipe cooling and Comparision with Experimental Measurements)

  • 주영춘;김은겸;신치범;조규영;박용남
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.269-274
    • /
    • 1999
  • Various method have been developed for mass concrete structures to reduce the temperature increase of concrete mass due to exothermic hydration reactions of concrete compounds and thereby to avoid thermal cracks. One of the methods widely acceptable for practical use is pipe cooling, in which cooling is achieved by circulating cold water through thin-wall steel pipes embedded in the concrete. A numerical simulation was performed to investigate the effectiveness of pipe cooling. A three-dimensional finite element method was proposed to analyse the transient three-dimensional heat transfer between the hardening concrete and the cooling water in pipe and to predict the stress development during the curing process. The effects of the cement type and content and the environment were taken into consideration by the heat generation rate and the boundary conditions, respectively. In order to test the validity of the numerical simulation, a model RC structure with pipe cooling was constructed and the time-dependent temperature and stress distributions within the structure as well as the variation of the temperature of cooling water along the pipe were measured. The results of the simulation agreed well the experimental measurements. The results of this study have important implications for the optimal design of the cooling pipe layout and for the estimation of thermal stress in order to eliminate thermal cracks.

  • PDF

냉각탑 수질관리를 위한 자동화 시스템 개발 (Water Quality Control System Development for Cooling Towers)

  • 이기건;송무준;이영재;성상경;강태삼
    • 제어로봇시스템학회논문지
    • /
    • 제14권1호
    • /
    • pp.36-41
    • /
    • 2008
  • Cooling tower is an important equipment of the cooling systems for large buildings like factory and department store. Water used for cooling in cooling tower is reused continuously. If the water is polluted, corrosion and scale can happen at equipments and pipes. In order to prevent this problem, it is necessary to control the water quality using chemicals. To control the water quality, an automatic control system is designed, fabricated, and experimented. The control system is based on an imbedded microcontroller. Relays are used for power driving, an LCD and LED for display, and RS485 for remote data acquisition. Monitoring program is also developed for easy man-machine interface and extraction of data stored in the imbedded processor and EEPROM. The control system calculates amounts of chemicals necessary using sensor data and injects the chemicals into the cooling tower on proper time. The developed water quality control system is expected to reduce cost of maintenance and extend the lifetime of the cooling systems with low cost.