• 제목/요약/키워드: cooling load

검색결과 1,001건 처리시간 0.026초

포트홀 다이를 이용한 컨덴서 튜브 직접압출 공정해석 및 금형강도 해석 (Die stress and Process of Analysis for Condenser Tube Extrusion by using a Porthole Die)

  • 이정민;이상곤;김병민;조형호;조훈
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.1030-1033
    • /
    • 2002
  • In this study, it is important that we have an understanding of the metal flow for manufacturing condenser tube in porthole die extrusion, because this need to provide for household appliances market that is expected to grow into the major market of the cooling system hereafter. Condenser tube is mainly manufactured by conform exclusion. However, this method was not satisfied a series of the needs for manufacturing condenser tube as compared with porthole die extrusion. The deforming skill recently is required high-productivity, high-accuracy and reducing lead-time, thus it is essential to substitute conform exclusion by porthole die exclusion. Porthole die extrusion has many advantages such as improvement of productivity, reduction of production cost etc. In general, the porthole die extrusion process consists of three stages(dividing, welding and forming stages). In order to obtain the detailed mechanics, to assist in the design of proper die shapes and sizes, and to improve the quality of products, porthole die extrusion should be analyzed in as non-steady state as possible during the entire process to evaluate detailed metal flow, temperature distribution, welding pressure and extrusion lead, and therm stress analysis was practiced to obtain effective stress and elastic deformation value. A analytical results provide useful information the optimal design of the porthole die for condenser tube.

  • PDF

터널 화재시 종류식 환기가 연소율 변화에 미치는 영향에 관한 실험적 연구 (An Experimental Study on the Effect of Longitudinal Ventilation on the Variation of Burning Rate in Tunnel Fires)

  • 양승신;김성찬;유홍선
    • 터널과지하공간
    • /
    • 제15권1호
    • /
    • pp.55-60
    • /
    • 2005
  • 본 연구는 터널내 화재 발생시 종류식 환기가 연소율 변화에 미치는 영향을 파악하기 위하여 Froude scaling에 의해 1/20크기로 축소한 모형화재 실험을 수행하였다. 화원으로는 $8.5cm{\sim}14.5cm$의 메탄올을 사용하였으며 발열량은 $3.57{\sim}10.95kW$이다. 연소율은 로드셀을 이용하여 산출하였고, 연기거동을 파악하기 위하여 K형 열전대를 이용하여 온도분포를 측정하였다. 풍동은 터널의 한쪽부분과 연결하였고, 터널 공간의 배연속도를 제어하기 위하여 풍동의 전압을 조절하였다. 메탄올 화재인 경우 배연속도가 증가할수록 냉각효과로 인하여 연소율은 감소하였으며, 또한 같은 무차원속도(V)일때 화원 크기가 커짐에 따라 연소율은 감소하였다.

30kW 급 합성가스 열병합 시스템 개발 및 효율 성능평가 (Development and efficiency evaluation of 30kW scale syngas cogeneration system)

  • 박일건;김상태;노귀성
    • 한국응용과학기술학회지
    • /
    • 제36권4호
    • /
    • pp.1427-1433
    • /
    • 2019
  • 본 연구에서는 합성가스의 에너지화를 위한 가스엔진 성능 평가를 수행하였다. 회전수 1800 rpm 조건에서 공기과잉률이 1, 1.1, 1.2, 1.3, 1.4, 1.5, 1.6 증가에 따른 엔진출력(kWm)과 열효율(%)을 평가한 결과, 공기과잉률 λ 1.4에서 엔진출력 34 kWm를 나타냈으며, 공기과잉률이 증가할수록 엔진 열효율은 전반적으로 감소하는 경향을 보였다. 엔진출력 34 kWm 조건에서 공기과잉률이 1, 1.1, 1.2, 1.3, 1.4 증가시 열효율이 34.2%, 36.9%, 37.2%, 37.4%, 38.1%로 증가하였고, 발전출력을 통한 종합효율은 발전출력 30 kWe 부하조건에서 38.7 kg/h의 연료를 소모하여 32.1%의 발전효율과 냉각수와 배기가스에서의 열회수를 통해 57.3 kW의 폐열을 회수하여 53.8%의 열을 회수하여 총 85.8%의 종합효율을 보이는 것으로 나타났다.

인공신경망을 이용한 데이터베이스 기반의 광역단지 에너지 수요예측 기법 개발 (A Methodology of Databased Energy Demand Prediction Using Artificial Neural Networks for a Urban Community)

  • 공동석;곽영훈;이병정;허정호
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.184-189
    • /
    • 2009
  • In order to improve the operation of energy systems, it is necessary for the urban communities to have reliable optimization routines, both computerized and manual, implemented in their organizations. However, before a production plan for the energy system units can be constructed, a prediction of the energy systems first needs to be determined. So, several methodologies have been proposed for energy demand prediction, but due to uncertainties in urban community, many of them will fail in practice. The main topic of this paper has been the development of a method for energy demand prediction at urban community. Energy demand prediction is important input parameters to plan for the energy planing. This paper presents a energy demand prediction method which estimates heat and electricity for various building categories. The method has been based on artificial neural networks(ANN). The advantage of ANN with respect to the other method is their ability of modeling a multivariable problem given by the complex relationships between the variables. Also, the ANN can extract the relationships among these variables by means of learning with training data. In this paper, the ANN have been applied in oder to correlate weather conditions, calendar data, schedules, etc. Space heating, cooling, hot water and HVAC electricity can be predicted using this method. This method can produce 10% of errors hourly load profile from individual building to urban community.

  • PDF

WELDING-INDUCED BUCKLING INSTABILITIES IN THIN PLATES

  • Han, Myoung-Soo;Tsai, Chon-Liang
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2002년도 Proceedings of the International Welding/Joining Conference-Korea
    • /
    • pp.661-667
    • /
    • 2002
  • Welding-induced buckling distortion is one of the most problematic concerns in both design and fabrication of welded thin-plate structures. This paper deals with experimental and numerical results of the welding-induced longitudinal and/or buckling distortion occurring in welding of 6mm-thick AH36 high strength steel plates. Effects of the heat input and the plate size on the distortion were experimentally evaluated for square plates. Bead-on-plate welding was performed with the submerged arc welding process along the middle line of plate specimens. Experimental results showed that the longitudinal distortion made a single curvature in the plate, and the distortion magnitude along the weld centerline was proportional to the heat input and the plate size. The experimental results were used to examine the validity of the numerical simulation procedure for welding-induced distortion where the longitudinal distortion mode and magnitude were numerically quantified. Three-dimensional, large deformation, welding simulations were performed for selected weld models. Numerical results of the distortion mode and magnitude were in a good agreement with experimental ones. Depending on the presence of halting the distortion growth during the cooling cycle of welding, the condition discriminating buckling distortion from longitudinal distortion was established. Eigenvalue analyses were performed to check the buckling instability of tested plates with different sizes subjected to different heat inputs. The perturbation load pattern for the analysis was extracted from longitudinal inherent strain distributions. Critical buckling curve from the eigenvalue analyses revealed that the buckling instability is manifested when plate size or heat input increases.

  • PDF

Development of SMH Actuator System Using Hydrogen-Absorbing Alloy

  • Kwon, Tae-Kyu;Jeon, Won-Suk;Pang, Du-Yeol;Choi, Kwang-Hun;Kim, Nam-Gyun;Lee, Seong-Cheol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1328-1333
    • /
    • 2005
  • This paper presents the temperature-pressure characteristics of a new SMH actuator using a Peltier module. The SMH actuator is characterized by its small size, low weight, noiseless operation, and compliance similar to that of the human body. The simple SMH actuator, consisting of the plated hydrogen-absorbing alloys as a power source, Peltier elements as a heat source, and a cylinder with metal bellows as a functioning part has been developed. To improve the thermal conductivity of the hydrogen-absorbing alloy, an assembly of copper pipes has been used. It is well known that hydrogen-absorbing alloys can reversibly absorb and desorb a large amount of hydrogen, more than about 1000 times of their own volume. The hydrogen equilibrium pressure increases when hydrogen is desorbed by heating of the hydrogen-absorbing alloys, whereas by cooling the alloys, the hydrogen equilibrium pressure decreases and hydrogen is absorbed. The new special metal hydride (SMH) actuator uses the reversible reaction between the heat energy and mechanical energy of a hydrogen absorbing alloys. The desirable characteristics of SMH actuator, which makes it suitable for the uses in medical and rehabilitation applications, have been also studied. For this purpose, the characteristics of the new SMH actuator for different temperature, pressure, and external load were explored.

  • PDF

The CO2 Reduction Potential Calculation through the Urban Park Construction

  • Lee, Eun Yeob;Kang, Myung Soo;Kim, Jong Kon
    • KIEAE Journal
    • /
    • 제14권2호
    • /
    • pp.87-98
    • /
    • 2014
  • This study is to identify quantitatively the function of carbon dioxide emissions reduction due to temperature and energy reduction according to direct carbon dioxide storage, shade provision, and evaportanspiration of urban park. According to the result of study, landscape tree indicated high carbon dioxide storage effect compare to bush, in which broadleaf tree indicated higher storage function than coniferous tree. It is believed to be the storage of carbon dioxide can be increased by increasing the composition rate of forest plants in the urban park. According to the direct estimation result of carbon dioxide storage in terms of example area, storage of carbon dioxide is estimated to be "seoul a zone" $476,818.8kg{\cdot}CO_2/m^2yr$, "anyang b zone" $186,435.7{\cdot}CO_2/m^2yr$, "daejeon c zone" $262,826{\cdot}CO_2/m^2yr$, "kwangju d zone" $231,657.8{\cdot}CO_2/m^2yr$. The carbon dioxide storage per unit area estimated to be "seoul a zone" $3.4{\cdot}CO_2/m^2yr$, "anyang b zone" $5.0{\cdot}CO_2/m^2yr$, "daejeon c zone" $2.6{\cdot}CO_2/m^2yr$, "kwangju d zone" $5.6{\cdot}CO_2/m^2yr$. The result of indirect carbon dioxide reduction effect estimated to be "seoul a zone" $291,603.4{\cdot}CO_2/m^2yr$, "anyang b zone" $165,462.4{\cdot}CO_2/m^2yr$, "daejeon c zone" $141,719.2{\cdot}CO_2/m^2yr$, "kwangju d zone" $154,803.4{\cdot}CO_2/m^2yr$. Carbon dioxide reduction potential amount through the urban park was increased to 1.6 times to 1.8 times when calculated to the indirect effect.

50KW 터보제너레이터용 가스터빈 엔진의 설계점/ 탈설계/과도성능해석 (On/Off-Design/Transient Analysis of a 50KW Turbogenerator Gas Turbine Engine)

  • 김수용;박무룡;조수용
    • 연구논문집
    • /
    • 통권27호
    • /
    • pp.87-99
    • /
    • 1997
  • Present paper describes on/off design performance of a 50KW turbogenerator gas turbine engine for hybrid vehicle application. For optimum design point selection, relevant parameter study is carried out. The turbogenerator gas turbine engine for a hybrid vehicle is expected to be designed for maximum fuel economy, ultra low emissions, and very low cost. Compressor, combustor, turbine, and permanent-magnet generator will be mounted on a single high speed (82,000 rpm) shaft that will be supported on air bearings. As the generator is built into the shaft, gearbox and other moving parts become unnecessary and thus will increase the system's reliability and reduce the manufacturing cost. The engine has a radial compressor and turbine with design point pressure ratio of 4.0. This pressure ratio was set based on calculation of specific fuel consumption and specific power variation with pressure ratio. For the given turbine inlet temperature, a rather conservative value of $1100^\circK$ was selected. Designed mass flow rate was 0.5 kg/sec. Parametric study of the cycle indicates that specific work and efficiency increase at a given pressure ratio and turbine inlet temperature. Off design analysis shows that the gas turbine system reaches self operating condition at N/$N_{DP}$ = 0.53. Bleeding air for turbine stator cooling is omitted considering low TIT and for a simple geometric structure. Various engine performance simulations including, ambient temperature influence, surging at part load condition. Transient analysis were performed to secure the optimum engine operating characteristics. Surge margin throughout the performance analysis were maintained to be over 80% approximately. Validation of present results are yet to be seen as the performance tests are scheduled by the end of 1998 for comparison.

  • PDF

권역별 난방에너지 요구량 분석을 통한 단열기준 개선방안 (Improvement Method of Regional Insulation Standard through the Regional Heating Energy Demand Analysis)

  • 김정국;안병립;장철용;정학근;한찬훈
    • KIEAE Journal
    • /
    • 제13권4호
    • /
    • pp.43-48
    • /
    • 2013
  • The effect of climate change has influenced humanity and ecosystem with tremendous changes in temperature. For the past 150 years, the national annual average temperature is 0.6 degree increased and the heating degree day reduced from April to November. However, December to January, the climate change was generated and the heating degree day increased. The blackout occured in 2011 and 2012 by increasing electricity consumption of heating and cooling equipment to the effects of climate change. That is because heating load accounted for 20% of building electric use. In this study, strengthening measures to reduce heating energy consumption is presented due to climate change in winter since 1980 to prevent blackout and reliable power supply for the building energy-saving design standards by Meteorological data provided by the National Weather Service were calculated using the heating degree days in order to present eighteen cities from 1980 to 2012. Insulation standards are presented to prevent black-out by the heating degree days. the heating energy demand was reduced almost 6% including 10% in Central, 5% in South and Jeju area based on strengthening of the insulation. It is applied to the entire country an annual economic effect of 250 billion won, and black-out can be prevented.

운전조건 변화에 따른 hot-gas 바이패스 냉동장치의 성능 특성 (Performance characteristics of hot-gas bypass refrigerator with the variation of operation conditions)

  • 백승문;손창효;허정호;최인수;윤정인
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권9호
    • /
    • pp.1021-1026
    • /
    • 2014
  • 본 논문에서는 hot-gas를 이용한 다양한 바이패스 제어 방식 중에서 증발기 흡입부 방식에 대해 각각의 성능에 영향을 미치는 외기온도, 출수온도, 과열 및 과냉도 등에 대해서 알아보았다. 그 주요 결과를 요약하면 다음과 같다. 우선, 증발기 흡입부로 hot-gas를 바이패스 하였을 경우에 냉동장치의 성능은 외기온도, 출수온도, 과열 및 과냉도 등에 영향을 받는 것을 알 수 있었다. 따라서 이러한 변수에 대한 최적화를 통해 본 냉동장치의 기초 설계 자료를 제공할 수 있다. 그리고 증발기 흡입부 hot-gas 바이패스 방식의 운전특성을 고찰하여 본 논문에서 제안하는 냉동장치에 대한 적용 가능성을 확인할 수 있었다.