• 제목/요약/키워드: cooling hole

검색결과 205건 처리시간 0.023초

전동차용 견인전동기의 열유동 특성에 관한 전산해석 (Numerical Analysis on Heat Transfer and Fluid Flow Characteristics of Traction Motor for Electric Car)

  • 남성원;김영남;채준희
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1998년도 추계학술대회 논문집
    • /
    • pp.137-143
    • /
    • 1998
  • Numerical simulation is conducted to clarify the heat transfer and fluid flow characteristics of traction motor for electric car SIMPLE algorithm based on finite volume method is used to make linear algebra equation. The governing equations are solved by TDMA(TriDiagonal Matrix Algorithm) with line-by-line method and block correction. From the results of simulation, the characteristics of cooling pattern is strongly affected by the size of hole in stator core. In the case of high rotational speed of rotor, temperature difference along the axial direction is more decreased than that of low rotational speed.

  • PDF

고속 고정밀 볼 스크류 구동에 따른 강제 냉각방식의 효과에 관한 연구 (A Study on Effect of Various Cooling Methods in Motion of High-Precision Ball Screw)

  • 김수상;허철수;김현구;류성기
    • 한국정밀공학회지
    • /
    • 제30권3호
    • /
    • pp.254-259
    • /
    • 2013
  • Ball screw system is widely used as a precision mechanical linear actuator that translates rotational motion to linear motion for its high efficiency, great stiffness and long life. Recently, according to the requirements of high accuracy and stiffness, the pre-load on the ball screw which means of remove the backlash in the ball screw is usually used. Because of the preload which means the frictional resistance between the screw and nut, becomes a dominating heat source and it generates thermal deformation of ball screw which is the reason for low accuracy of the positioning decision. There are several methods to solve the problem that includes temperature control, thermal stable design and error compensation. In the past years, researchers focused on the error compensation technique for its ability to correct ball screw error effectively rather than the capabilities of careful machine design and manufacturing. Significant amounts of researches have been done to real-time error compensation. But in this paper, we developed a series of cooling methods to get thermal equilibrium in the ball screw system. So we find the optimum cooling type for improving positioning error which caused by thermal deformation in the ball screw system.

레이저 드릴링을 통한 강판 가공 시 응력 모델링 (Stress Modeling of the Laser Drilling Process in Carbon Steel)

  • 이우람;김주한
    • 대한기계학회논문집A
    • /
    • 제37권7호
    • /
    • pp.857-864
    • /
    • 2013
  • 레이저 정밀 가공은 고품질의 집속 광에너지를 이용하여 재료를 미세하게 가공하는 특수 가공으로 정밀 제조 분야에 적용되고 있다. 그러나 레이저 가공 시 열적 효과로 인해 재료 특성을 저하 시킬 수 있다. 또한, 압연 강재 및 강판의 경우 공정 단계에서 강한 압력으로 제작하기 때문에 반드시 잔류응력이 존재한다. 하지만 압연 강재에 존재하는 잔류응력의 양은 정량적인 예측이 불가능하다. 이러한 잔류응력이 존재하는 재료의 레이저 가공 시 레이저에 의한 부가적인 응력 발생 및 재료에 미치는 열적 영향의 예측 및 평가는 정밀 가공에 있어서 반드시 고려해야 하는 사항이다. 본 연구에서는 레이저 홀 가공 시 발생되는 온도 및 응력을 유한요소 해석과 실험적 방법으로 분석하였다. 재료의 열응력을 예측하기 위해 레이저 홀가공 실험을 수행하여 가열 및 냉각 등의 대한 결과를 도출하였다. 또한 냉각 시간에 따른 응력의 변화를 파악하였고 유한요소 해석으로 예측된 응력을 홀드릴링 응력 측정 기법에 의해 도출된 응력과 비교 검증하였다.

마이크로 칩 Yb:YAG 레이저의 동작 및 열적 특성 (Operational and Thermal Characteristics of a Microchip Yb:YAG Laser)

  • 문희종;홍성기;임창환
    • 한국광학회지
    • /
    • 제22권2호
    • /
    • pp.96-101
    • /
    • 2011
  • 본 논문에서는 930 nm 대역 광섬유 결합 레이저 다이오드 여기광을 0.8 mm 두께의 얇은 디스크형 Yb:YAG 결정에 조사하여 레이저 발진 특성을 연구하였다. 구멍이 있는 구리판 사이에 레이저 결정을 고정시켜 발생된 열을 접촉 냉각시키는 구조를 채택하였고, 구리판 구멍 크기에 따른 조사 지점의 온도 변화를 발진 피크 스펙트럼 이동으로부터 조사하였다. 광섬유 결합 LD 여기 광에 대해 발진 레이저 출력은 기울기 효율 42.2%, 광변환 효율 34.8%로 높게 구현되었다. LD 여기 전류 및 구리판 구멍 크기가 증가함에 따라 여기광이 조사된 지점의 온도가 증가하였다. 구리판 구멍 크기가 결정 두께에 비해 상당히 큰 경우, 높은 여기광의 세기에서는 온도 상승이 선형 변화로부터 벗어남을 확인하였다.

핵연료 시험용 노내조사시험설비의 설계 현황 (The Design Status of the Irradiation Facility for Fuel Test)

  • 박국남;심봉식;안성호;유성연
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.310-315
    • /
    • 2007
  • The FTL has been developed to be able to irradiate test fuels at the irradiation hole(IR1 hole) by considering its utility and user's irradiation requirements. FTL consists of In-Pile Test Section (IPS) and Out-of-Pile System (OPS). Test condition in IPS such as pressure, temperature and the water quality, can be controlled by OPS. For safety assurance IPS is designed to have dual stainless steel pressure vessel and OPS is composed of main cooling water system, emergency cooling water system, LMP(letdown, make-up, purification) system, etc. FTL Conceptual design was set up in 2001, basic design had completed including a design requirement, basic piping & instrument diagram (P&ID), and the detail design in 2004. In 2005, the development team carried out purchase and manufacture hardware and make a contract for construction work. FTL construction work began on August, 2006 and ended on March, 2007. After FTL development which is expected to be finished by 2008, FTL will be used for the irradiation test of the new PWR-type fuel and can maximize the usage of HANARO.

  • PDF

이론적 열유동 해석을 이용한 농산물 저장 및 유통 스마트 유닛로드 컨테이너의 통기공 최적화 설계 (Ventilation Hole Optimum Design of Smart Unit Load Container for Storage and Distribution Agricultural Products by Theoretical Heat Flow Analysis)

  • 최동수;김용훈;김진세;박천완;정현모;김기석;박종민
    • 한국포장학회지
    • /
    • 제28권3호
    • /
    • pp.211-215
    • /
    • 2022
  • Air distribution occupies an important position in the smart unit load container design process for agricultural products. Inner air may be uncomfortable because of its temperature, speed, direction, and volume flow rate. It doesn't matter how efficient the ventilation equipment is if the air is not distributed well. The main aim of this study was to design the inlet and outlet fan locations of smart unit load container for agricultural products. A numerical study was performed on the effects of the location of inlet air and outlet air in relation to the container cooling sources on air distribution and thermal comfort. A concept of combining inner container cooling sources with the exhaust outlet was employed in this investigation. Also, in this research, the developed CFD (Computational Fluid Dynamics) models were thoroughly validated. This system was adopted for use in container spaces, where the exhaust outlet was located. In this study, the location of the inlet was derived through CFD for a container with a size of 1,100×1,100×1,700 mm, and it was derived that the inlet was located at the center of the lower part of the container for efficient air flow. It was efficient to position the outlet through the air inlet in the center of the lower part of the container at the top of the same side.

심지층 처분을 일한 사용후핵연료 냉각기간 분석 (Analysis of the Spent Fuel Cooling Time for a Deep Geological Disposal)

  • 이종열;조동건;최희주;최종원;이양
    • 방사성폐기물학회지
    • /
    • 제6권1호
    • /
    • pp.65-72
    • /
    • 2008
  • 사용후핵 연료 심지층 처분의 목적은 그 독성이 인간 및 자연환경에 영향을 미치지 않도록 장기간 동안 격리하고, 방사성물질의 누출을 지연시키는 것이다. 이러한 심지층 처분장 설계시 주요한 요건은 처분시스템의 건전성 유지를 위하여 폐기물로부터 발생된 열로 인하여 완충재의 온도가 $100\;^{\circ}C$를 넘지 않도록 하는 것이다. 따라서, 원자력 발전소에서 방출된 후의 사용후핵연료 냉각기간은 심지층 처분장 설계시 효율 및 경제성을 위한 중요한 고려인자이다. 본 연구에서는 가장 적절한 사용후핵연료 냉각기간 설정을 위하여 처분시스템 온도요건을 만족하는 심지층 처분장 배치에 필요한 처분터널-처분공 간격 및 그에 따른 면적, 열하중에 대한 분석을 수행하였다. 이를 위하여, 기준 처분개념을 바탕으로 사용후핵연료의 냉각기간 및 처분터널/처분공 간격을 다양하게 설정하여, 처분시스템에서의 열적 안정성을 해석하고 그 결과를 비교분석하였다. 그리고 분석 결과를 바탕으로 처분면적 측면에서 효율적인 사용후핵연료 냉각기간을 도출하였다. 그 결과, 사용후핵연료의 냉각기간이 짧을수록 처분장에서 설계온도 제한치 범위내 최고온도에 이르는 시간은 빨라지고, 사용후핵연료 냉각기간이 길수록 처분장에서 온도상승 및 하강속도는 완만해지는 것으로 나타났다. 또한, 본 연구에서 고려대상으로 삼은 처분장 규모와 사용후핵연료를 심지층에 처분한다고 할 때 그 냉각기간을 40-50년으로 함이 적합한 것으로 나타났다.

  • PDF

가스터빈 블레이드 팁의 열전달과 유동 특성에 대한 수치적 해석 (Numerical Analysis of Heat Transfer and Flow Characteristics on Squealer Tip of Gas Turbine Blade)

  • 쟈오리우;강영석;김동화;조진수
    • 한국항공우주학회지
    • /
    • 제44권12호
    • /
    • pp.1062-1070
    • /
    • 2016
  • 본 연구에서는 전산해석을 통해 냉각 터빈 블레이드 팁 간극의 유동 및 열전달 특성을 연구하였다. 1단 고압터빈 노즐 출구에서 획득한 속도, 온도 프로파일을 로터의 입구에 적용하여 로터 도메인을 대상으로 전산해석을 하였다. 스퀼러 팁이 적용된 블레이드의 팁 간극을 스팬의 1%부터 2.5%로 조절하여 팁 간극의 공력 손실, 열전달 계수와 막냉각 효율의 영향을 고찰했다. 팁 간극이 커질수록 출구에서 공력 손실과 블레이드 끝단 표면에서 열전달 계수는 증가하였다. 특히 팁 간극이 스팬의 2%일 때 평균 열전달 계수가 급격히 증가하였다. 팁 영역의 막냉각 효율은 팁 간극이 작을수록 높았고, 캐비티 내부 냉각 홀 근처의 막냉각 효율이 높았다.

경사제트에 따른 충돌제트/유출냉각에서 열/물질전달 특성 (Effect of Inclined Jet on Heat/Mass Transfer for Impingement/Effusion Cooling System)

  • 홍성국;이동호;조형희
    • 대한기계학회논문집B
    • /
    • 제32권4호
    • /
    • pp.283-289
    • /
    • 2008
  • An experimental investigation was conducted to investigate the heat/mass transfer for impingement/effusion cooling system with inclined jet. Jets with inclined angle of 60 are applied to impingement/effusion cooling. At the jet Reynolds number of 10,000, the experiments were carried out for blowing ratios ranging from 0.0 to 1.5. The local heat/mass transfer coefficients on the effusion plate are measured using a naphthalene sublimation method. The result indicates that the inclined jet causes the non-uniform and low heat/mass transfer compared to the vertical jet. At stagnation region, the peak position is shifted from the geometrical center of injection hole due to Coanda effect and its level is higher than that of vertical jet due to increase in turbulence intensity by steep velocity gradient near the stagnation region. Further, the secondary peak region disappears because the interaction between adjacent wall jets weakens. When the initial crossflow occurs, the distorted heat/mass transfer pattern appears. As the blowing ratio (crossflow rate) increases, the heat/mass transfer distributions become similar to those of the vertical jet. This is because the effect of crossflow is dominant compared to that of inclined jet under high blowing ratio $(M{\geq}1.0)$. At low blowing ratio $(M{\leq}0.5)$, averaged Sh value is 10% lower than that of vertical jet, whereas its value at high blowing ratio $(M{\geq}1.0)$ is similar to that of vertical jet.