• Title/Summary/Keyword: cool storage

Search Result 73, Processing Time 0.028 seconds

Changes in Physicochemical Properties of Rice Grain during Long-Term Storage (장기저장한 벼 종실의 이화학적 특성 변화)

  • Lee, In-Keun;Kim, Kwang-Ho;Choi, Hae-Chune
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.38 no.6
    • /
    • pp.524-530
    • /
    • 1993
  • The experiment was carried out to investigate the changes in physicochemical properties of milled rice harvested in different year and stored for four to sixty four months. The fat acidity of milled rice increased sharply from four to sixteen months storage, and after then it was increased slowly to sixty four months. Amylose, magnesium, potassium content, and K/Mg ratio of milled rice were not changed by storage duration. Water absorption rates of milled rice at 21$^{\circ}C$ and 77$^{\circ}C$, and alkali digestion value were increased by longer storage duration. Difference of water absorption rate between rice samples was greater during initial forty minutes after soaking at 21$^{\circ}C$ and with longer the soaking time at 77$^{\circ}C$. Shorter gel length of rice flour was found with prolonged storage duration, while peak, minimum, cool, breakdown and setback viscosity of gelatinized rice flour on amylograph were increased along with increasing the storage duration. The volume expansion rate during cooking and degree of iodine coloration of cooking water were higher in the longer stored rice compared with shorter one, and the amount of soluble solid in cooking water was significantly decreased in rice stored longer period.

  • PDF

GC Capillary Column Installation (가스 크로마토그래피 캐필러리 컬럼 설치 가이드)

  • Matt James;Kirsty Ford
    • FOCUS: LIFE SCIENCE
    • /
    • no.1
    • /
    • pp.2.1-2.6
    • /
    • 2024
  • This article provides detailed instructions for the correct installation, maintenance, and troubleshooting of capillary gas chromatography (GC) columns. It emphasizes the importance of proper installation to ensure optimal performance and longevity of the column. The document covers various aspects such as column trimming, installation, conditioning, testing, storage, and ferrule selection. The installation process involves ensuring that the heated zones of the GC are cool before placing the column cage in the column oven. It is essential to avoid sharp bends or stress on the capillary column during installation and to connect the front end of the column into the GC inlet at the recommended insertion distance. The document also provides guidance on trimming the column, including the use of a ceramic wafer or capillary column cutter to achieve a clean, burr-free cut. For previously used columns, it recommends removing any capillary caps, positioning the nut and ferrule, and trimming 1-2 cm from the column. After installation, the column should be purged with carrier gas to remove any oxygen and avoid oxidizing the column. Conditioning the column involves ramping to the upper isothermal temperature limit and maintaining this temperature for a specified duration. It is crucial to maintain carrier gas flow during conditioning and not exceed the upper temperature limit of the column to avoid phase damage. The document also discusses testing column performance using a suitable method and performing a test injection to assess performance. It provides recommendations for column storage, including flame-sealing the capillary ends or using retention gaps for long-term storage. Additionally, it emphasizes the importance of routine maintenance and replacement of GC consumables to extend the column's lifetime. Ferrule selection is another important aspect covered in the article, with a variety of ferrule materials available for different applications. The characteristics of common ferrule options are presented in a table, including temperature limits, reusability, and suitability for specific detector types.

  • PDF

Manipulation of Summer Diapause by Chilling in Matsucoccus thunbergianae (Hemiptera: Coccoidea: Margarodidae) (저온처리에 의한 솔껍질깍지벌레 여름휴면의 조절)

  • Lee, Jong-Hee;Wi, An-Jin;Park, Seung-Chan
    • Korean journal of applied entomology
    • /
    • v.52 no.4
    • /
    • pp.349-356
    • /
    • 2013
  • A set of experiments were conducted to determine the zero temperature and total effective temperature for the summer diapause and post-diapause development of Matsucoccus thunbergianae Miller et Park (Hemiptera: Margarodidae) which infests the Japanese black pine, Pinus thunbergii. The diapausing first instar nymphs were kept in cool storage during three separate times, each starting from May 4th, June 19th, and August 15th of 2002. Cool storage temperatures were 2.5, 5.0, 7.5, 10.0, 12.5 and $15.0^{\circ}C$. The nymphs were chilled for 10, 20, 30 or 40 days in the first two sets of experiments. In the third experiment, nymphs were chilled for 3, 6, 9 or 12 days. Molting into the second instar nymphs was examined every 10 days, starting at 20 days after taken out from the cool storage. Optimum temperature range of the diapause development was between 7.5 and $10^{\circ}C$, where diapause development was completed in 40, 20, and 6 days by the insects chilled from May 4th, June 19th and August 15th, respectively. Comparing the three sets of experiments with different chilling periods, zero temperature for diapause development was calculated as $29^{\circ}C$. Effective temperature for diapause development was 964 degree days, and it was estimated that nymphs completed their diapause development by September 8th in nature. Under natural temperature conditions >50% eclosion into the second instar occurred on November 9th. Zero temperature for post-diapause development was $10^{\circ}C$, and total effective temperature for post-diapause development until the molt into the second instar was 391 degree days.

A Study on Integrated Control and Safety Management Systems for LNG Membrane Storage Tank (멤브레인식 LNG 저장탱크용 통합제어안전관리시스템에 대한 연구)

  • Kim, Chung-Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.2
    • /
    • pp.40-46
    • /
    • 2010
  • In this study, the integrated control and safety management system for a super-large LNG membrane storage tank has been presented based on the investigation and analysis of measuring equipments and safety analysis system for a conventional LNG membrane storage tank. The integrated control and safety management system, which may increase a safety and efficiency of a super-large LNG membrane storage tank, added additional pressure gauges and new displacement/force sensors at the steel anchor between an inner tank and a prestressed concrete structure. The displacement and force sensors may provide clues of a membrane panel failure and a LNG leakage from the inner tank. The conventional leak sensor may not provide proper information on the membrane panel fracture even though LNG is leaked until the leak detector, which is placed at the insulation area behind an inner tank, send a warning signal. Thus, the new integrated control and safety management system is to collect and analyze the temperature, pressure, displacement, force and LNG density, which are related to the tank system safety and leakage control from the inner tank. The digital data are also measured from measurement systems such as displacement and force of a membrane panel safety, LNG level and density, cool-down process, leakage, and pressure controls.

Variation and Correlation of Shearing Force with Feed Nutritional Characteristics of Wheat Straw

  • Cui, X.M.;Yang, Z.B.;Yang, W.R.;Jiang, S.Z.;Zhang, G.G.;Liu, L.;Wu, B.R.;Wang, Z.F.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.26 no.10
    • /
    • pp.1466-1473
    • /
    • 2013
  • This experiment was conducted to study the variation laws and correlations of shearing force and feed characteristics including morphological characteristic, chemical composition and in situ degradability of wheat straw. Feasibility of evaluating the nutritional value of wheat straws with shearing force values was analyzed in this study. Six hundred wheat straw plants (Jimai 22) were randomly selected and placed in a cool and ventilated place. Samples were collected in the 1st, 15th, 30th, 45th, 60th d after harvest to measure shearing force, morphological characteristic, nutritional composition. Rumen degradation of dry matter (DM), neutral detergent fiber (NDF) and acid detergent fiber (ADF) of wheat straws were determined by the nylon bags method. The results demonstrated that linear and quadratic effects of storage time on all the tested morphological characteristics were significantly correlative (p<0.01). As storage time goes on, all the tested nutrients and their rumen degradations of wheat straw was linearly (p<0.01) and quadratic (p<0.01) correlative except ADF content and rumen degradation of ADF. Significant correlations were determined in linear effect of shearing force on morphological characteristics (p<0.01), and linear density and diameter were a more sensitive predictor than stem thickness for shearing force. There were strong correlations between storage time and all the measured physical characteristics (shearing force, morphological characteristics and shearing force standardized by morphological characteristics) (p<0.01). Nutrition compositions were linearly correlative with shearing force and standardized shearing force (p<0.01). The linear correlation between rumen degradation of DM and NDF and shearing force and standardized shearing force were evident (p<0.01). In conclusion, shearing force, nutrition compositions and their rumen degradation of wheat straw were still dynamic with storage time after harvest. Correlation could be found between shearing force and nutritional characteristics of wheat straw. Nutrient content, morphological index and rumen degradation of DM and NDF could be predicted by changes in shearing force. Shearing force should be applied according to a standardized storage time when it is used to forecast the feed value of wheat straws.

Design and Operation of a Small-Scale Hydrogen Liquefier (소형 수소액화기 설계 및 운전에 관한 연구)

  • Baik, Jong Hoon;Karng, Sarng Woo;Kang, Hyungmook;Garceau, Nathaniel;Kim, Seo Young;Oh, In-Hwan
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.26 no.2
    • /
    • pp.105-113
    • /
    • 2015
  • In order to accelerate hydrogen society in current big renewable energy trend, it is very important that hydrogen can be transported and stored as a fuel in efficient and economical fashion. In this perspective, liquid hydrogen can be considered as one of the most prospective storage methods that can bring early arrival of the hydrogen society by its high gravimetric energy density. In this study, a small-scale hydrogen liquefier has been designed and developed to demonstrate direct hydrogen liquefaction technology. Gifford-McMahon (GM) cryocooler was employed to cool warm hydrogen gas to normal boiling point of hydrogen at 20K. Various cryogenic insulation technologies such as double walled vacuum vessels and multi-layer insulation were used to minimize heat leak from ambient. A liquid nitrogen assisted precooler, two ortho-para hydrogen catalytic converters, and highly efficient heat pipe were adapted to achieve the target liquefaction rate of 1L/hr. The liquefier has successfully demonstrated more than 1L/hr of hydrogen liquefaction. The system also has demonstrated its versatile usage as a very efficient 150L liquid hydrogen storage tank.

A Study on the Actual Conditions of Museum Environment for Old Textile Collections -Focused on university Museums- (직물류 유물의 전시 및 보관환경 실태조사-대학박물관을 중심으로-)

  • 배순화
    • Journal of the Korean Society of Costume
    • /
    • v.34
    • /
    • pp.109-120
    • /
    • 1997
  • The conservation of collections in muse-ums is an important aspect for our her-itage. The control of museum environment is a vital factor in the preservation of cool-lections. Inappropriate or fluctuating envi-ronmental conditions can cause irreparable damage to works of arts. In this research we investigated the ac-tual conditions of museum environment for old testiles using questionnaire and mea-sured dye fasing of old textiles on exhibi-tion for 2 months in a university museum the major results are as follows: 1. The control of temperature and rela-tive humidity is a vital factors I the preservation of old textiles in museum generally acceptable temperature and rel-ative humidity standards for old textiles are 18-23$^{\circ}C$ and 50-65% R. H and light level for textiles on exhibition should be limited to 30-50 lux. 2, In university museums the limate control system in exhibition and storage area is in an early stage. Therefore to minimize the deterioration of old textiles the best method of controlling the envi-ronment is to have centralized climate control system in sorage area as well as in display area. 3. Conservator is needed to maintain collections scientifically. Only professional conservator by combining scientific tech-nical and artistic training has the exper-tise needed to maintain the physical in-tegrity of old textiles. In order to solve the inferior environment of museums the staff should recognize the importance of the condition of exhibition and storage. 4. Old textiles are susceptible to damage by light and associated heat. Dyed textiles which have been exhibited under the light without any UV filter were faded notice-ably within two months of exhibition. Light levels for textiles on exhibition should be limited to 30-50 lux. It is de-sirable to use special light source that can absorb UV. and UV filter is also recom-mended to reduce photodegradation of old textiles.

  • PDF

A Basic Study on the District Cooling System of LNG Cold Thermal Energy (LNG 냉열 에너지의 지역 냉방 시스템에 관한 기반 연구)

  • Kim Chung Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.7 no.4 s.21
    • /
    • pp.36-43
    • /
    • 2003
  • This paper provides the possibility of the district cooling system by using a LNG cold thermal energy. A liquefied natural gas provides a plenty of cooling source energy during a gasification of a liquefied natural gas. In recent, an ice thermal storage system is used for cooling a building, and a deep water source cooling system has been introduced as a district cooling system in which is used to cool the office towers and other large buildings in old and new downtown. LNG cooling energy refers to the reuse of a large body of naturally cold fluids as a heat sink for process and comfort space cooling as an alternative of conventional, refrigerant based cooling systems. Coincident with significant clean energy and operating cost savings, LNG cold energy cooling system offers radical reductions in air-borne pollutants and the release of environmentally harmful refrigerants in comparison to the conventional air-conditioning system. This study provides useful information on the basic design concepts, environmental considerations and performance related to the application of LNG cold thermal energy.

  • PDF

Experimental validation of the seismic analysis methodology for free-standing spent fuel racks

  • Merino, Alberto Gonzalez;Pena, Luis Costas de la;Gonzalez, Arturo
    • Nuclear Engineering and Technology
    • /
    • v.51 no.3
    • /
    • pp.884-893
    • /
    • 2019
  • Spent fuel racks are steel structures used in the storage of the spent fuel removed from the nuclear power reactor. Rack units are submerged in the depths of the spent fuel pool to keep the fuel cool. Their free-standing design isolates their bases from the pool floor reducing structural stresses in case of seismic event. However, these singular features complicate their seismic analysis which involves a transient dynamic response with geometrical nonlinearities and fluid-structure interactions. An accurate estimation of the response is essential to achieve a safe pool layout and a reliable structural design. An analysis methodology based on the hydrodynamic mass concept and implicit integration algorithms was developed ad-hoc, but some dispersion of results still remains. In order to validate the analysis methodology, vibration tests are carried out on a reduced scale mock-up of a 2-rack system. The two rack mockups are submerged in free-standing conditions inside a rigid pool tank loaded with fake fuel assemblies and subjected to accelerations on a unidirectional shaking table. This article compares the experimental data with the numerical outputs of a finite element model built in ANSYS Mechanical. The in-phase motion of both units is highlighted and the water coupling effect is detailed. Results show a good agreement validating the methodology.

A Study on the Integrated Control and Safety Management System for 9% Ni Steel LNG Storage Tank (9% 니켈강재식 LNG 저장탱크용 통합제어안전관리시스템에 관한 연구)

  • Kim, Chung-Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.5
    • /
    • pp.13-18
    • /
    • 2010
  • This paper presents the development of an integrated control and safety management system for 9% nickel steel LNG storage tank. The new system added the measuring equipment of pressure, displacement and force compared to the conventional measurement and control system. The measured data has simultaneously been processed by integrating and analyzing with new control equipments and safety management systems. The integrated control and safety management system, which may increase a safety and efficiency of a super-large full containment LNG storage tank, added additional pressure gauges and new displacement/force sensors at the outer side wall and a welding zone of a stiffener and top girder of an inner tank, and the inner side wall of a corner protection tank. The displacement and force sensors may provide failure clues of 9% nickel steel structures such as an inner tank and a corner protection, and a LNG leakage from the inner tank. The conventional leak sensor may not provide proper information on 9% nickel steel tank fracture even though LNG is leaked until the leak detector, which is placed at the insulation area between an inner tank and a corner protection tank, sends a warning signal. Thus, the new integrated control and safety management system is to collect and analyze the temperature, pressure, displacement, force, and LNG density, which are related to the tank system safety and leakage control from the inner tank. The digital data are also measured from control systems such as displacement and force of 9% nickel steel tank safety, LNG level and density, cool-down process, leakage, and pressure controls.