• Title/Summary/Keyword: conventional radiography

Search Result 196, Processing Time 0.024 seconds

Progression of Korean Herbal Medicine and Conventional Medicine Administration for Cough in Patients with Myocardial Infraction Relapse Suspected of Developing Acute Respiratory Infection: Case Report (호흡기감염 후 심근경색이 재발한 것으로 의심되는 환자의 기침에 대한 한양방 약물 병용투여 경과 : 증례보고)

  • Kim, Bo-min;Jo, Hee-geun
    • The Journal of Internal Korean Medicine
    • /
    • v.40 no.1
    • /
    • pp.145-153
    • /
    • 2019
  • Objectives: This case is significant as a rare observational record at the Korean medical practice field. This case reports progression of co-administration of Korean herbal medicines and conventional medicines for cough in patients with myocardial infarction relapse suspected of developing acute respiratory infection. Methods: First, the chest radiography, CBC count and urinalysis were performed to estimate patient's systematic condition. After the estimated diagnosis, the patient was treated with modified Dingchuan decoction, antibiotics, and complex syrup for cough. We used the Cough-Specific Quality-of-Life Questionnaire (CQLQ) to assess patient's respiratory symptoms. Results: Co-administration of Korean herbal medicines and conventional medicines resulted improving of cough and sputum symptoms. Laboratory analysis items and total score of CQLQ also showed significantly improved results. Adverse effects were not observed. Conclusions: In this case, we concluded that co-administration of Korean herbal medicine and conventional medicine may be an effective therapy for the treatment of cough in patients with myocardial relapse of developing acute respiratory infection.

CARIES DIAGNOSIS BY DIAGNODENT'S LASER FLUORESCENCE DETECTION IN VITRO (레이저형광측정을 통한 Diagnodent의 우식진단에 관한 생체외 연구)

  • Kim, Seong-Hyeong;Lee, Kwang-Hee;Kim, Dae-Eop;Park, Jong-Seok
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.1
    • /
    • pp.24-31
    • /
    • 2000
  • The purpose of study was to compare the laser fluorescence detection by Diagnodent(KaVo, Germany), visual inspection using dental explorers, and conventional dental radiography as diagnostic tests for dental caries. One hundred and three human premolars and molars which had no caries or fissure caries were tested by the three methods. Diagnodent scores increased as the scores of the other two tests increased(P<0.01) There were significant relationships between visual inspection scores and Diagnodent scores(Pearson 0.676, Spearman 0.694) and between radiography scores and Diagnodent scores(Pearson 0.623, Spearman 0.658) (P<0.01, all). Diagnodent test proved to have high sensitivity and low specificity and more studies are necessary to present the diagnostic criteria for progressive caries stages.

  • PDF

C-Arm Fluoroscopy for Accurate Reduction of Facial Bone Fracture (C-Arm 유도하의 안면골 골절의 정복술)

  • Hwang, So-Min;Kim, Jang Hyuk;Kim, Hyung-Do;Jung, Yong-Hui;Kim, Hong-Il
    • Archives of Craniofacial Surgery
    • /
    • v.14 no.2
    • /
    • pp.96-101
    • /
    • 2013
  • Background: Among facial fractures, nasal bone fracture, zygomatic arch fracture and mandibular subcondyle fracture take a large portion. Among surgical operations for nasal bone fracture, zygomatic arch fracture and mandibular subcondyle fracture, closed reduction has been generally used but, unlike open reduction, there is a problem in evaluating its accuracy of reduction. Methods: An assessment was made from October 2011 until April 2013 prospectively on 37 patients. For all the operations, closed reductions were executed in a conventional way and simultaneously using C-Arm to verify the reduction of fractures. Two images of plain radiography, one taken before operation and another one taken one day after the operation, were compared. After obtaining images of plain radiography using C-Arm immediately after the correction upon operation, they were compared with the images of plain radiography taken one day after the operation. Results: The fracture reductions of 26 patients among 27 nasal fracture patients were satisfactory but one patient showed a marginal overcorrection of less than 1 mm. The fracture reductions of 7 patients among 8 zygomatic arch fracture patients were satisfactory but one patient showed a marginal undercorrection of less than 2 mm. All of two mandibular subcondyle fracture patients showed less than 2 mm undercorrection. Conclusion: Closed reduction guided by C-Arm for nasal bone fracture, zygomatic arch fracture and mandibular subcondyle fracture was clinically useful because it could make a real-time assessment on fractured areas and add immediate corrections during the operation.

Clinical and panoramic radiographic features of osteomyelitis of the jaw: A comparison between antiresorptive medication-related and medication-unrelated conditions

  • Shin, Jeong Won;Kim, Jo-Eun;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.49 no.4
    • /
    • pp.287-294
    • /
    • 2019
  • Purpose: This study was performed to analyze the clinical and imaging features of contemporary osteomyelitis(OM) and to investigate differences in these features on panoramic radiography according to patients' history of use of medication affecting bone metabolism. Materials and Methods: The records of 364 patients(241 female and 123 male, average age 66.8±14.9 years) with OM were retrospectively reviewed. Panoramic imaging features were analyzed and compared between patients with medication-related OM(m-OM) and those with conventional, medication-unrelated OM(c-OM). Results: The age of onset of OM tended to be high, with the largest number of patients experiencing onset in their 70s. The 2 most frequent presumed causes were antiresorptive medication use (44.2%) and odontogenic origin (34.6%). On panoramic radiographs, a mix of osteolysis and sclerosis was the most common lesion pattern observed (68.6%). Sequestrum, extraction socket, and periosteal new bone formation were found in 143(42.1%), 79 (23.2%), and 24 (7.1%) cases, respectively. The m-OM group exhibited sequestrum and extraction socket more frequently and displayed significantly higher mandibular cortical index values than the c-OM group. Conclusion: We observed some differences in imaging features as shown on panoramic radiography according to the history of antiresorptive medication use. This study may help elucidate the predictive imaging features of medication-related osteonecrosis of the jaw.

A STUDY ON THE ARTIFICIAL INTERPROXIMAL CARIES DETECTION WITH THE DIGITAL RADIOGRAPHY (디지털방사선촬영술을 이용한 인접면 치아우식증 진단에 관한 실험적 연구)

  • Kwon Ki Jeong;Hwang Eui-Hwan;Lee Sang Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.24 no.1
    • /
    • pp.85-94
    • /
    • 1994
  • The purposes of this study were clinical comparison and evaluation between digital radiography and conventional radiography for the detection of artificial interproximal caries. Four freshly extracted, unrestored posterior teeth were obtained and caries was simulated by drilling semicircled defects with variable size at the interproximal surface of each tooth. The experiments were performed with IBM-PC/32 bit-DX compatible, video camera(VM-S8200, Hitachi Co., Japan), and color monitor(Multisync 3D, NEC, Japan). Sylvia Image Capture Board for the ADC(analog to digital converter) was used, and spatial resolution was 512 × 480 with 256 gray levels. The obtained results were as follows: 1. At the condition of under exposure, the radiographs were superior to the digital images in readability. Also, as the size of the artificial lesion was increased, readability of the radiographs was elevated. 2. The digital images were superior to the radiographs in readability especially under over exsposure. 3. As the exposure time and size of lesion was increased, the gray level of region of interest of the digital image was decreased proportionally. 4. As the F-value of average gray level of region of interest at individual exposure time and size of lesion, gray level of the all lesion sizes was decreased in comparison with that of the normal enamel.

  • PDF

THE ACCURACY OF DIGORA SYSTEM, AN INDIRECT DIGITAL RADIOGRAPHIC SYSTEM, IN DETERMINING THE WORKING LENGTH (근관장 측정시 구내 디지털 방사선 시스템인 Digora System의 정확도에 관한 연구)

  • Han, Sang-Wook;Hang, Chan-Ui;Cho, Yong-Bum
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.347-357
    • /
    • 1997
  • An accurate working length is an essential factor in the success of endodontic treatment. There are several methods for determining working length; electronic apex locator, tactile sense by clinician, and radiography. Among these methods, the most commonly used method is radiography. But this method requires excessive radiation, long developing time, and many equipments. In additon, it could give an image distortion and two dimensional image. To improve these disadvantages, an intraoral digital radiographic system (Digora$^{(R)}$) which use an imaging plate instead of a film, was developed. The purpose of this investigation was to compare Digora imaging with conventional radiography in determining the working length. Maxillary first or second molars of human dried skull were used. Files were inserted into canals at randomly selected lengths, from 2mm short of the radiographic apex to 2rnm beyond. Radiographs and Digora images(Digora positive and Digora negative) were evaluated to determine the adjustment needed to place the file 0.5mm from the radiographic apex. The results were as follows ; 1. There was no significant difference in accuracy between those evaluated in ${\pm}0.5mm$ and those accurately evaluated in the 3 images. 2. When comparing the accuracy of each image without distinguishing the 3 images, in the group accurately determined within ${\pm}0.5mm$, the mesiobuccal group showed significantly higher accuracy compared to the palatal group(p<0.05).

  • PDF

The Characteristic of Temperature and Dose Distribution of intra oral X-ray Tube (강내형 X선 튜브 온도 및 선량 분포 특성)

  • Cho, Sungho;Lee, Rena
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.5
    • /
    • pp.262-266
    • /
    • 2013
  • A new concept of periapical radiography, intra oral x-ray tube and detector system is introduced. It is new system that a miniature x-ray tube is inserted into mouse and it acquired digital image using external detector. In this study, we have investigated temperature and dose distribution of insertional x-ray tube for periapical radiography. To analyze temperature characteristic of x-ray tube, we attached the thermocouple to surface of x-ray tube and we measured the temperature according to distance. Also, we measured the dose distribution of a miniature x-ray tube according to distance. As a result, temperature was constant to $27^{\circ}C$ over 2mm without cooling system, dose distribution of x-ray tube was 3.14 and 1.84mGy in 3 and 5cm, respectively. Therefore, the proposed x-ray system works in lower dose than conventional dental x-ray system. Thus, it is considered that new concept of system will have a significant effect on medical imaging technology.

A modified device for intraoral radiography to assess the distal osseous defects of mandibular second molar after impacted third molar surgery

  • Ana, Faria-Inocencio;Mercedes, Gallas-Torreira
    • Imaging Science in Dentistry
    • /
    • v.41 no.3
    • /
    • pp.115-121
    • /
    • 2011
  • Purpose : This article is to describe a modified device for intraoral radiography which was developed to obtain reproducible radiographic images for assessment of distal osseous defects of the mandibular second molar (2 Mm) after impacted third molar (3 Mm) surgery. Materials and Methods : A commercial available alignment system for posterior region was modified by adding a reference gauge pin (millimetric) and threading a hollow acrylic cylinder at the ring of the radiographic positioner to attach the X-ray collimator. The design included customized resin acrylic stent for the occlusal surface of the 2Mm in maximum intercuspal position, individualizing the biteblock positioner. Periapical radiographs were taken before and after surgical extraction of 3 Mm, employing the radiographic technique of parallelism described by Kugelberg (1986) with this modified film holder and inserting the gauge pin on the deepest bone probing depth point. Results : This technique permitted to obtain standardized periapical radiographs with a moderate to high resolution, repeatability, and accuracy. There was no difference between the measurements on the pre- and post-operative radiographs. This technique allowed better maintenance of the same geometric position compared with conventional one. The insertion of the gauge pin provided the same reference point and localized the deepest osseous defect on the two-dimensional radiographs. Conclusion : This technique allowed better reproducibility in posterior radiographic records (distal surface of 2 Mm) and more accurate measurements of radiographic bone level by the use of a millimetric pin.

Digital Tomosynthesis Imaging of the Chest : Comparison of Patient Exposure Dose and Image Quality between Default Setting and Use Additional Filter (흉부 디지털토모영상의 기본모드 및 부가여과사용 시 환자선량과 화질비교)

  • Kim, Kye-Sun;Ahn, Sung-Min;Kim, Sung-Chul
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.9
    • /
    • pp.288-294
    • /
    • 2013
  • Chest digital tomosynthesis was the most advanced digital radiography technology, but it was higher patient dose than conventional chest radiography. Thus we tried to reduce a patient dose of chest digital tomosynthesis and evaluated its image quality. Result shows that radiation dose such as ESD, DAP and ED were 1.95 mGy, 17.66 $dGycm^2$ and 0.133 mSv respectively in default setting and 0.312 mGy, 2.27 $dGy.cm^2$ and 0.052 mSv in use additional filter, respectively. Doses were decrease 66.2%, 73.6% and 57.4% in ESD, DAP and ED, respectively. At the image quality assessment, overall sensitivities of use additional filter for nodule detection were not inferior to default mode for peripheral, central and peripheral micro nodules. However, sensitivity of low dose mode was significantly inferior to the default for central micro-nodules(p < .001).

Reduction of Scattered Radiation by Air Gap Technique for High Kilovoltage Chest Roentgenography (흉부(胸部) 고관전압(高管電壓) 촬영(撮影)에 있어 Air Gap Technique를 이용한 산란선(散亂線) 경감(輕減)에 관(關)한 연구(硏究))

  • Huh, Joon;Kim, Chang-Kyun;Kang, Hong-Seok;Youn, Chul-Ho;Lee, Sang-Suk;Lim, Han-Young;Song, Jae-Kwan
    • Journal of radiological science and technology
    • /
    • v.3 no.1
    • /
    • pp.57-66
    • /
    • 1980
  • X-ray grid is the most important means to reduce the scattered ray from patients, but alternative way is air gap technique that is another name of Groedel technique. This technique is mainly used in chest radiography. Authors performed an experimental study on the air gap technique for chest radiography and obtained the results as follows; 1. In using the high voltage air technique, scattered ray could be reduced effectively, while the percentage of scattered ray was slightly increased than conventional grid technique. 2. In film contrast, 30cm air gap technique was inferior to 12:1 grid technique and contrast improvement was increased when the object was thicker and higher voltage was used. 3. The patient exposure dose was reduced about $25{\sim}45%$ compared with conventional grid technique by air gap technique used.

  • PDF