• Title/Summary/Keyword: conventional procedure

Search Result 1,560, Processing Time 0.03 seconds

Passive 3D motion optical data in shaking table tests of a SRG-reinforced masonry wall

  • De Canio, Gerardo;de Felice, Gianmarco;De Santis, Stefano;Giocoli, Alessandro;Mongelli, Marialuisa;Paolacci, Fabrizio;Roselli, Ivan
    • Earthquakes and Structures
    • /
    • v.10 no.1
    • /
    • pp.53-71
    • /
    • 2016
  • Unconventional computer vision and image processing techniques offer significant advantages for experimental applications to shaking table testing, as they allow the overcoming of most typical problems of traditional sensors, such as encumbrance, limitations in the number of devices, range restrictions and risk of damage of the instruments in case of specimen failure. In this study, a 3D motion optical system was applied to analyze shake table tests carried out, up to failure, on a natural-scale masonry structure retrofitted with steel reinforced grout (SRG). The system makes use of wireless passive spherical retro-reflecting markers positioned on several points of the specimen, whose spatial displacements are recorded by near-infrared digital cameras. Analyses in the time domain allowed the monitoring of the deformations of the wall and of crack development through a displacement data processing (DDP) procedure implemented ad hoc. Fundamental frequencies and modal shapes were calculated in the frequency domain through an integrated methodology of experimental/operational modal analysis (EMA/OMA) techniques with 3D finite element analysis (FEA). Meaningful information on the structural response (e.g., displacements, damage development, and dynamic properties) were obtained, profitably integrating the results from conventional measurements. Furthermore, the comparison between 3D motion system and traditional instruments (i.e., displacement transducers and accelerometers) permitted a mutual validation of both experimental data and measurement methods.

Liquid crystal alignment on rubbed self-assembled monolayers according to alkyl chain length (알킬 사슬 길이에 따른 러빙 처리된 자기 조립 단분자막의 액정 배향 연구)

  • Park, Hong-Gyu;Park, Mu-Hun
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.14 no.5
    • /
    • pp.362-368
    • /
    • 2021
  • A homeotropic liquid crystal (LC) alignment state on rubbed fluorinated self-assembled monolayers (FSAMs) is described according to alkyl chain length. A simple procedure, gas-phase method, for the preparation of FSAM was used. The average optical transmittance in the visible light range of FSAMs were 76.63% to 78.21%, which were superior to the conventional polyimide layer having a transmittance of 75.89%. In addition, the excellent homeotropic LC alignment characteristics of FSAMs were observed through pretilt angle measurement and polarized optical microscope images. By measuring the contact angles and the surface energies of FSAMs, it was confirmed that pretilt angles of LC molecules increased according to the alkyl chain length. High optical transparency and uniform homeotropic LC alignment characteristics of FSAMs showed the possibility of FSAMs as an LC alignment layers.

Noise Removal using Gaussian Distribution and Standard Deviation in AWGN Environment (AWGN 환경에서 가우시안 분포와 표준편차를 이용한 잡음 제거)

  • Cheon, Bong-Won;Kim, Nam-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.6
    • /
    • pp.675-681
    • /
    • 2019
  • Noise removal is a pre-requisite procedure in image processing, and various methods have been studied depending on the type of noise and the environment of the image. However, for image processing with high-frequency components, conventional additive white Gaussian noise (AWGN) removal techniques are rather lacking in performance because of the blurring phenomenon induced thereby. In this paper, we propose an algorithm to minimize the blurring in AWGN removal processes. The proposed algorithm sets the high-frequency and the low-frequency component filters, respectively, depending on the pixel properties in the mask, consequently calculating the output of each filter with the addition or subtraction of the input image to the reference. The final output image is obtained by adding the weighted data calculated using the standard deviations and the Gaussian distribution with the output of the two filters. The proposed algorithm shows improved AWGN removal performance compared to the existing method, which was verified by simulation.

Indocyanine green fluorescence videoangiography for reliable variations of supraclavicular artery flaps

  • Suzuki, Yushi;Shimizu, Yusuke;Kasai, Shogo;Yamazaki, Shun;Takemaru, Masashi;Kitamura, Takuya;Kawakami, Saori;Tamura, Takeshi
    • Archives of Plastic Surgery
    • /
    • v.46 no.4
    • /
    • pp.318-323
    • /
    • 2019
  • Background Pedicled flaps are useful for reconstructive surgery. Previously, we often used vascularized supraclavicular flaps, especially for head and neck reconstruction, but then shifted to using thoracic branch of the supraclavicular artery (TBSA) flaps. However, limited research exists on the anatomy of TBSA flaps and on the use of indocyanine green (ICG) fluorescence videoangiography for supraclavicular artery flaps. We utilized ICG fluorescence videoangiography to harvest reliable flaps in reconstructive operations, and describe the results herein. Methods Data were retrospectively reviewed from six patients (five men and one woman: average age, 54 years; range, 48-60 years) for whom ICG videoangiography was performed to observe the skin perfusion of a supraclavicular flap after it was raised. Areas where the flap showed good enhancement were considered to be favorable for flap survival. The observation of ICG dye indicated good skin perfusion, which is predictive of flap survival; therefore, we trimmed any areas without dye filling and used the remaining viable part of the flap. Results The flaps ranged in size from $13{\times}5.5cm$ to $17{\times}6.5cm$. One patient received a conventional supraclavicular flap, four patients received a TBSA flap, and one patient received a flap that was considered to be intermediate between a supraclavicular flap and a TBSA flap. The flaps completely survived in all cases, and no flap necrosis was observed. Conclusions The TBSA flap is very useful in reconstructive surgery, and reliable flaps could be obtained by using ICG fluorescence videoangiography intraoperatively.

Melting of Al2O3 powder using the skull melting method (Skull melting법에 의한 Al2O3 파우더 용융)

  • Choi, Hyun-Min;Kim, Young-Chool;Seok, Jeong-Won
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.29 no.1
    • /
    • pp.24-31
    • /
    • 2019
  • The current study demonstrates an efficient procedure to create ingots from $Al_2O_3$ powder using the skull melting method to use these ingots as a starting material in conventional methods for growing synthetic single-crystal sapphire. Dimension of the cold crucible was 24 cm in inner diameter and 30 cm in inner height, 15 kg of $Al_2O_3$ powder was completely melted within 1 h at an oscillation frequency of 2.75 MHz, maintained in the molten state for 3 h, and finally air-cooled. The areal density and components of the cooled ingot by parts were analyzed through scanning electron microscopy with energy dispersive X-ray spectroscopy (SEM-EDS). The areal density and $Al_2O_3$ content of the ingot were related to the temperature distribution inside the cold crucible during high-frequency induction heating, and the area with high temperature was high tends to be high in areal density and purity.

Implementation of UHD Broadcasting Receiver Based on ATSC 3.0 Standards (ATSC 3.0 기반 UHD 방송 수신기의 구현)

  • Kim, Yong Suk;Seo, Jae Hyun;Lee, Bong Ho;Kim, Heung Mook
    • Journal of Broadcast Engineering
    • /
    • v.23 no.6
    • /
    • pp.790-799
    • /
    • 2018
  • UHD broadcasting based on ATSC 3.0 is being implemented in Korea, and discussion on mobile broadcasting based on ATSC 3.0 is underway. The ATSC 3.0 standard introduces internet protocol based standards in order to facilitate the implementation of conventional broadcasting services as well as broadcasting and communication convergence services interlocking with communication services. In this process, various requirements for the receiver have been derived, and factors to consider for developing the receiver product have also increased. ATSC 3.0 broadcasting is currently in the introduction stage of the service, and additional technology development and product implementation related to the receiver should proceed until the full-scale market is formed. In this regard, this paper describes the considerations for developing UHD receiver based on ATSC 3.0 and the test procedure for verifying developed receiver.

Prediction Model for Specific Cutting Energy of Pick Cutters Based on Gene Expression Programming and Particle Swarm Optimization (유전자 프로그래밍과 개체군집최적화를 이용한 픽 커터의 절삭비에너지 예측모델)

  • Hojjati, Shahabedin;Jeong, Hoyoung;Jeon, Seokwon
    • Tunnel and Underground Space
    • /
    • v.28 no.6
    • /
    • pp.651-669
    • /
    • 2018
  • This study suggests the prediction model to estimate the specific energy of a pick cutter using a gene expression programming (GEP) and particle swarm optimization (PSO). Estimating the performance of mechanical excavators is of crucial importance in early design stage of tunnelling projects, and the specific energy (SE) based approach serves as a standard performance prediction procedure that is applicable to all excavation machines. The purpose of this research, is to investigate the relationship between UCS and BTS, penetration depth, cut spacing, and SE. A total of 46 full-scale linear cutting test results using pick cutters and different values of depth of cut and cut spacing on various rock types was collected from the previous study for the analysis. The Mean Squared Error (MSE) associated with the conventional Multiple Linear Regression (MLR) method is more than two times larger than the MSE generated by GEP-PSO algorithm. The $R^2$ value associated with the GEP-PSO algorithm, is about 0.13 higher than the $R^2$ associated with MLR.

A Study on LLC Resonant Transformer Design with the Winding Method of Automatic Type suitable for LLC Resonant Converter (LLC 공진 컨버터에 적합한 자동화 권선 LLC 공진 변압기 설계에 관한 연구)

  • Bae, Jun-Hyung;Kim, Jong-Hae
    • Journal of IKEEE
    • /
    • v.23 no.3
    • /
    • pp.1108-1111
    • /
    • 2019
  • This paper presents the comprehensive transformer design methodology with the winding method of automatic type suitable for LLC resonant converter. The problem with conventional LLC resonant transformer is that it is difficult to implement the winding method of automatic type because all windings are wound in one bobbin. Therefore, the LLC resonant transformer, which is capable of the winding method of automatic type to multiple section bobbin without insulation tape and barrier tape, is proposed in this paper and the design procedure of the proposed LLC resonant transformer is also shown. Modeling and analysis of the proposed LLC resonant transformer using Maxwell 3D simulation tool are described in detail and a protype 150W LLC resonant converter using the proposed LLC resonant transformer manufactured by 3D modelling is also verified through the experimental test.

Lateral Resistance of CLT Wall Panels Composed of Square Timber Larch Core and Plywood Cross Bands

  • JANG, Sang Sik;LEE, Hyoung Woo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.47 no.5
    • /
    • pp.547-556
    • /
    • 2019
  • Thinned, small larch logs have small diameters and no value-added final use, except as wood chips, pallets, or fuel wood, which are products with very low economic value; however, their mechanical strength is suitable for structural applications. In this study, small larch logs were sawed, dried, and cut into square timbers (with a $90mm{\times}90mm$ cross section) that were laterally glued to form core panels used to manufacture cross-laminated timber (CLT) wall panels. The surface and back of these core panels were covered with 12-mm-thick structural plywood panels, used as cross bands to obtain three-ply CLT wall panels. This attachment procedure was conducted in two different ways: gluing and pressing (CGCLT) or gluing and nailing (NGCLT). The size of the as-manufactured CLT panels was $1,220mm{\times}2,440mm$, the same as that of the plywood panels. The final wall panels were tested under lateral shear force in accordance with KS F 2154. As the lateral load resistance test required $2,440mm{\times}2,440mm$ specimens, two CLT wall panels had to be attached in parallel. In addition, the final CLT panels had tongued and grooved edges to allow parallel joints between adjacent pieces. For comparison, conventional light-frame timber shear walls and midply wall systems were also tested under the same conditions. Shear walls with edge nail spacing of 150 mm and 100 mm, the midply wall system, and the fabricated CGCLT and NGCLT wall panels exhibited maximum lateral resistances of 6.1 kN/m (100%), 9.7 kN/m (158%), 16.9 kN/m (274%), 29.6 kN/m (482%), and 35.8 kN/m (582%), respectively.

Rapid Staining Using the Shorr Method for Intraoperative Peritoneal Washing Cytology in Advanced Gastric Cancer: a Pilot Study from a Single Institution

  • Son, Sang-Yong;Choi, Hai-Young;Lee, Yoontaek;Park, Young Suk;Shin, Dong Joon;Oo, Aung Myint;Jung, Do Hyun;Ahn, Sang-Hoon;Park, Do Joong;Lee, Hye Seung;Kim, Hyung-Ho
    • Journal of Gastric Cancer
    • /
    • v.19 no.2
    • /
    • pp.173-182
    • /
    • 2019
  • Purpose: Intraoperative peritoneal washing cytology (PWC) is used to determine treatment strategies for gastric cancer with suspected serosal invasion. However, a standard staining method for intraoperative PWC remains to be established. We evaluated the feasibility of a rapid and simple staining method using Shorr's stain for intraoperative PWC in advanced gastric cancer. Materials and Methods: Between November 2012 and December 2014, 77 patients with clinical T3 or higher gastric cancer were enrolled. The sensitivity, specificity, and concordance between the Shorr staining method and conventional Papanicolaou (Pap) staining with carcinoembryonic antigen (CEA) immunohistochemistry (IHC) were analyzed. Results: Intraoperative PWC was performed laparoscopically in 69 patients (89.6%). The average time of the procedure was 8.3 minutes, and the average amount of aspirated fluids was 83.3 mL. The average time for Shorr staining and pathologic review was 21.0 minutes. Of the 77 patients, 16 (20.7%) had positive cytology and 7 (9.1%) showed atypical findings; sensitivity and specificity were 73.6% and 98.2% for the Shorr method, and 78.9% and 98.2% for the Pap method with CEA IHC, respectively. Concordance of diagnosis between the 2 methods was observed in 90.9% of cases (weighted ${\kappa}$ statistic=0.875) and most disagreements in diagnoses occurred in atypical findings (6/7). In overall survival, there was no significant difference in C-index between the 2 methods (0.459 in Shorr method vs. 0.458 in Pap with CEA IHC method, P=0.987). Conclusions: Shorr staining could be a rapid and reliable method for intraoperative PWC in advanced gastric cancer.