• Title/Summary/Keyword: conventional method

Search Result 17,691, Processing Time 0.046 seconds

A Study on the Process Sequence Design of a Tub for the Washing Machine Container (세탁조의 제작공정해석 및 공정개선에 관한 연구)

  • 임중연;이호용;황병복
    • Transactions of Materials Processing
    • /
    • v.3 no.3
    • /
    • pp.359-374
    • /
    • 1994
  • Process sequence design in sheet metal forming process by the finite element method is investigated. The forming of sheet metal into a washing machine container is used to demonstrate the design of an improved process sequence which has fewer operations. The design procedure makes extensive use of the finite element method which has simulation capabilities of elastic-plastic modeling. A one-stage process to make an initial blank to the final product is simulated to obtain information on metal flow requirements. Loading simulation for a conventional method is also performed to evaluate the design criteria which are uniform thickness distribution around the finished part and maximum punch load within limit of available press capacity. The newly designed sequence has two forming operations and can achieve net-shape manufacturing, while the conventional process sequence has three forming operations. This specific case conventional process sequence has three forming operations. This specific case can be considered for application of the method and for development of the sequence design methodology in general.

  • PDF

Micro-cathter System for Measurement of Intra-abdominal Pressure (복강내압 측정을 위한 초소형 카데터 시스템)

  • Seo, Ho-Young;Na, Sungdae;Kim, Myoung Nam
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.8
    • /
    • pp.1430-1438
    • /
    • 2017
  • Recently, interest that intra-abdominal pressure has been increased as change of pathophysiology to critical patients. The intra-abdominal pressure is measured by cystometry what can be available for non-inclusively. However, conventional methods have some problems such as low SNR, weakness of environment temperature, and unsuitable size of sensor. In this paper, a new subminiature pressure sensor module and sensing system are proposed using a sensor of semiconductor type and FPCB. The module is more stable, flexible, and smaller than the conventional catheter. The performance of the developed module is evaluated by various quantitative analysis indexes. The proposed sensor has the high sensitivity and suitable size for measurement of cystometry more than the conventional method. In order to prove efficiency between conventional and proposed method, proposed method compared for sensitivity, fixable, and size. The proposed method will be help measurement of intra-abdominal pressure of patients due to high accuracy and comfortableness.

Analytical Head-space Supercritical Fluid Extraction Methodology for the Determination of Organochlorine Compounds in Aqueous Matrix

  • Ryoo, Keon-Sang;Ko, Seong-Oon;Hong, Yong-Pyo;Choi, Jong-Ha;Kim, Yong-gyun;Lee, Won-Kyoung
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.5
    • /
    • pp.649-656
    • /
    • 2006
  • The proposed head-space supercritical fluid extraction (SFE) methodology as an alternative to an existing conventional procedure was explored for the determination of organochlorine compounds in aqueous matrix. In this study, polychlorinated biphenyls (PCBs) and organochlorine pesticides (OCPs) were utilized as target analytes. To enhance the recovery efficiency, the factors such as the $CO _2$ density, the extraction time, and the extraction mode were investigated. Furthermore, the analytical procedures and the results obtained were compared with those provided by the conventional method (the U.S. EPA method 8080). Under the optimized conditions, i.e., a combination of static with dynamic SFE mode at 2,000 psi and 40 ${^{\circ}C}$, the head-space SFE methodology gave equivalent or better to the conventional method in recovery efficiencies with clear advantages such as simple sample treatment and fast analysis time as well as reduced solvent and reagent consumption.

Effect of Air Flow During Curing Process on Physical Properties of Bulk Cured Leaves (황색종 Bulk건조시 송풍량 조절에 따른 건조엽의 물리성 변화)

  • 이철환;진정의;한철수
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.21 no.1
    • /
    • pp.5-9
    • /
    • 1999
  • In recent years, the line of increase in policy on tobacco production triggered a rise in the loading volume per bulk curing barn, and manufacturers boosted the output of their blowers in order to prevent dirty leaves in the process of curing. for this reason, we studied the effect of the reducing air flow in bulk curing chamber from the color fixing stage to the stem drying stage of flue curing process on physical properties of cured leaves. The control of air flow was composed of the reducing air velocity of blower by means of a voltage regulator (slidac), and condition before color fixing stage was all the same with the conventional curing method. As a result, an effectiveness of improvement in the physical properties of cured leaves were observed. The leaves cured by this method were somewhat orange in color of upper stalk position, better bodied, and less brittle compared with the leaves produced by conventional curing. However, the leaves cured by this method had a little sharpness and harshness. As to the physical properties, there was decreased in occurrence of flat leaves than that of conventional ones. On the other hand, in case of reducing air flow during the curing process, increase of price per kg reached to about 5 % compared with those of conventional curing method.

  • PDF

Enhancement of Analytical Method for Phenolic Compounds in Mainstream Cigarette Smoke Using High Efficiency Column and RRLC system (고효율 컬럼과 RRLC를 이용한 담배 주류연 중 페놀 화합물의 분석 효율화)

  • Min, Hye-Jeong;Kang, Young-Hee;Lee, Jeong-Min;Jang, Gi-Chul
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.32 no.1
    • /
    • pp.35-40
    • /
    • 2010
  • This study was carried out to enhance the analytical methods of phenolic compounds in mainstream cigarette smoke using high efficiency column and RRLC(Rapid Resolution Liquid Chromatography) system, and to compare these methods. RRLC system offers significantly faster results with higher data quality of phenolic compounds than conventional HPLC, but it is disadvantage that it is expensive. On the other hand, the method using monolithic column offers faster results by the use of conventional HPLC system without new equipment introduction. In this study, we used the linear type smoking machine and Health Canada method for pre-treatment process of phenolic compounds. The analysis time of phenolic compounds using RRLC and monolithic column was individually 8 and 15 minutes, whereas in the conventional HPLC it was 45 minutes. These new methods were accompanied with the minimal solvent consumption and had lower analysis costs. Also, we proved that there were no difference between new methods and conventional method in accuracy by statistic.

Hormone induced recipients for embryo transfer in mice

  • Lee, Yeonmi;Kang, Eunju
    • Journal of Animal Reproduction and Biotechnology
    • /
    • v.36 no.4
    • /
    • pp.247-252
    • /
    • 2021
  • Embryo transfer (ET) in the animal is an important procedure to generate genetically engineered animals and conserve genetic resources. For ET experiments in mice, pseudopregnant recipients are usually prepared with proestrus stage of females and vasectomized males. However, this conventional method is inefficient because the size of female colonies should be large to select only the proestrus stage in the estrous cycle and the surgical procedures are required to generate vasectomized males. In this study, we established a simple and efficient protocol to prepare ET recipients using the estrous synchronization with hormone injection and the mating with wild male mice. The delivery rate of ET recipients tended to be increased with estrous synchronization using hormone injection (100%) compared to the conventional method (71%). Further, natural pregnancy of the recipients, induced by mating with a wild male, significantly enhanced the birth rate of ET offspring than the conventional method (33% vs. 13%). Based on the results, we concluded that our new protocol using hormone injection to ET recipients and mating with wild males could be more efficient and simpler compared to the conventional method.

Hyperparameter Tuning Based Machine Learning classifier for Breast Cancer Prediction

  • Md. Mijanur Rahman;Asikur Rahman Raju;Sumiea Akter Pinky;Swarnali Akter
    • International Journal of Computer Science & Network Security
    • /
    • v.24 no.2
    • /
    • pp.196-202
    • /
    • 2024
  • Currently, the second most devastating form of cancer in people, particularly in women, is Breast Cancer (BC). In the healthcare industry, Machine Learning (ML) is commonly employed in fatal disease prediction. Due to breast cancer's favorable prognosis at an early stage, a model is created to utilize the Dataset on Wisconsin Diagnostic Breast Cancer (WDBC). Conversely, this model's overarching axiom is to compare the effectiveness of five well-known ML classifiers, including Logistic Regression (LR), Decision Tree (DT), Random Forest (RF), K-Nearest Neighbor (KNN), and Naive Bayes (NB) with the conventional method. To counterbalance the effect with conventional methods, the overarching tactic we utilized was hyperparameter tuning utilizing the grid search method, which improved accuracy, secondary precision, third recall, and finally the F1 score. In this study hyperparameter tuning model, the rate of accuracy increased from 94.15% to 98.83% whereas the accuracy of the conventional method increased from 93.56% to 97.08%. According to this investigation, KNN outperformed all other classifiers in terms of accuracy, achieving a score of 98.83%. In conclusion, our study shows that KNN works well with the hyper-tuning method. These analyses show that this study prediction approach is useful in prognosticating women with breast cancer with a viable performance and more accurate findings when compared to the conventional approach.

A Study on Encryption Method using Hash Chain and Session Key Exchange in DRM System (DRM 시스템에서 해쉬체인과 세션키 교환을 이용한 암호화 기법에 관한 연구)

  • Park, Chan-Kil;Kim, Jung-Jae;Lee, Kyung-Seok;Jun, Moon-Seog
    • The KIPS Transactions:PartC
    • /
    • v.13C no.7 s.110
    • /
    • pp.843-850
    • /
    • 2006
  • This is devoted to first, to propose a hash chain algorithm that generates more secure key than conventional encryption method. Secondly, we proposes encryption method that is more secure than conventional system using a encryption method that encrypts each block with each key generated by a hash chain algorithm. Thirdly, After identifying the user via wired and wireless network using a user authentication method. We propose a divided session key method so that Although a client key is disclosed, Attackers cannot catch a complete key and method to safely transfer the key using a divided key method. We make an experiment using various size of digital contents files for performance analysis after performing the design and implementation of system. Proposed system can distribute key securely than conventional system and encrypt data to prevent attacker from decrypting complete data although key may be disclosed. The encryption and decryption time that client system takes to replay video data fie is analogous to the conventional method.

De-epithelialized dermal flap for nipple reconstruction: A modified star flap

  • Lee, Su Hyun;Kim, Deok Woo;You, Hi Jin;Jung, Jae A;Hwang, Na Hyun;You, Jae Pil;Yoon, Eul Sik
    • Archives of Plastic Surgery
    • /
    • v.46 no.4
    • /
    • pp.324-329
    • /
    • 2019
  • Background Multiple approaches for nipple reconstruction exist, and none is considered superior to all others. The star flap is one of the most popular methods for nipple reconstruction, but gradual height loss is a major concern. We present a new modification of the star flap that incorporates a de-epithelialized dermal flap, along with the associated surgical results. Methods We reviewed the medical records of patients who underwent nipple reconstruction using the modified star flap method. The design was different from the conventional star flap in that the lateral wings were changed into a trapezoidal shape and de-epithelialized dermal flaps were added. The patients were followed up at 2, 4, 6, and 12 months postoperatively, and nipple height was measured. The postoperative nipple height achieved using the modified method was compared with that obtained using the traditional method. Results From February 2013 to June 2017, 32 patients received surgery using the modified star flap, and 18 patients who underwent nipple reconstruction before 2013 comprised the conventional method group. All patients had undergone breast reconstruction with an abdominal tissue-based flap. The mean follow-up period was 14.4 months in the modified method group and 17.3 months in the conventional method group. The mean maintenance of projection at 12 months postoperatively was $56.28%{\pm}18.58%$ in the modified method group, and $44.23%{\pm}14.15%$ in the conventional method group. This difference was statistically significant (P<0.05). Conclusions The modified method using a de-epithelialized dermal flap provides reliable maintenance of projection in patients who have undergone abdominal tissue-based breast reconstruction.

Simplified sequential construction analysis of buildings with the new proposed method

  • Afshari, Mohammad Jalilzadeh;Kheyroddin, Ali;Gholhaki, Majid
    • Structural Engineering and Mechanics
    • /
    • v.63 no.1
    • /
    • pp.77-88
    • /
    • 2017
  • Correction Factor Method (CFM) is one of the earliest methods for simulating the actual behavior of structure according to construction sequences and practical implementation steps of the construction process which corrects the results of the conventional analysis just by the application of correction factors. The most important advantages of CFM are the simplicity and time-efficiency of the computations in estimating the final modified forces of the beams. However, considerable inaccuracy in evaluating the internal forces of the other structural members obtained by the moment equilibrium equation in the connection joints is the biggest disadvantage of the method. This paper proposes a novel method to eliminate the aforementioned defect of CFM by using the column shortening correction factors of the CFM to modify the axial stiffness of columns. In this method, the effects of construction sequences are considered by performing a single step analysis which is more time-efficient when compared to the staged analysis especially in tall buildings with higher number of elements. In order to validate the proposed method, three structures with different properties are chosen and their behaviors are investigated by application of all four methods of: conventional one-step analysis, sequential construction analysis (SCA), CFM, and currently proposed method.