• Title/Summary/Keyword: conventional cone

Search Result 188, Processing Time 0.025 seconds

Physical and Mechanical Characteristics of Subgrade Soil using Nondestructive and Penetration Tests (비파괴시험과 관입시험에 의한 노상토의 물리·역학적 특성)

  • Kim, Kyu-Sun;Kim, Dong-Hee;Fratta, Dante;Lee, Woojin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.1C
    • /
    • pp.19-27
    • /
    • 2011
  • This paper evaluates the applicability of wave-based nondestructive methodologies and a penetration test for compaction quality measurements during road construction. To evaluate the physical and mechanical properties of compacted subgrade soil layers, soil stiffness gauge (SSG), time domain reflectometry (TDR), and miniature electro-mechanical systems (MEMS) accelerometers were used to nondestructively evaluate the soil response during and after compaction and dynamic cone penetrometer (DCP) profiles were used to evaluate the soil shear strength after compaction was completed. At the field site, two types of soils were compacted with four different compaction equipments and energies. Field testing results indicate that soil parameters evaluated by different testing methods, which are SSG, TDR, MEMS accelerometer, and DCP, are highly correlated. In addition, it is shown that the physical and mechanical tests deployed in this study can be used as alternative methods to the conventional compaction quality evaluation methods when assessing the overall quality and the engineering response of compacted lifts.

Assessment of endodontically treated teeth by using different radiographic methods: an ex vivo comparison between CBCT and other radiographic techniques

  • Demiralp, Kemal Ozgur;Kamburoglu, Kivanc;Gungor, Kahraman;Yuksel, Selcen;Demiralp, Gokcen;Ucok, Ozlem
    • Imaging Science in Dentistry
    • /
    • v.42 no.3
    • /
    • pp.129-137
    • /
    • 2012
  • Purpose: To compare different radiographic methods for assessing endodontically treated teeth. Materials and Methods: Root canal treatments were applied in 120 extracted mandibular teeth, which were divided into four groups: (1) ideal root canal treatment (60 teeth), (2) insufficient lateral condensation (20 teeth), (3) root canals filled short of the apex (20 teeth), (4) overfilled root canal treatment (20 teeth). The teeth were imaged using intraoral film, panoramic film, digital intraoral systems (CCD and PSP), CCD obtained with portable X-ray source, digital panoramic, and CBCT images obtained at 0.3 $mm^3$ and 0.2 $mm^3$ voxel size. Images were evaluated separately by three observers, twice. Kappa coefficients were calculated. The percentage of correct readings obtained from each modality was calculated and compared using a t-test (p<0.05). Results: The intra-observer kappa for each observer ranged between 0.327 and 0.849. The inter-observer kappa for each observer for both readings ranged between 0.312 and 0.749. For the ideal root canal treatment group, CBCT with 0.2 $mm^3$ voxel images revealed the best results. For insufficient lateral condensation, the best readings were found with periapical film followed by CCD and PSP. The assessment of teeth with root canals filled short of the apex showed the highest percentage of correct readings by CBCT and CCD. For the overfilled canal treatment group, PSP images and conventional periapical film radiographs had the best scores. Conclusion: CBCT was found to be successful in the assessment of teeth with ideal root canal treatment and teeth with canals filled short of the apex.

Improvement of Head Related Transfer Function to Create Realistic 3D Sound (현실감있는 입체음향 생성을 위한 머리전달함수의 개선)

  • Koo, Kyo-Sik;Cha, Hyung-Tai
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.18 no.3
    • /
    • pp.381-386
    • /
    • 2008
  • Virtual 3D audio methods that create 3D sound effects are researched highly for multimedia devices using 2 speakers or headphone. The most typical method to create 3D effects is a technology through use of head related transfer function (HRTF) which contains the information that sound arrives from a sound source to the ears of the listener. But it can decline some 3D effects by cone of confusion between front and back directions due to the non-individual HRTF depending on each listener. In this paper, we propose a new method to use psychoacoustic theory that creates realistic 3D audio. In order to improve 3D sound, we calculate the excitation energy of each symmetric HRTF and extract the ratio of energy of each bark range. Informal listening tests show that the proposed method improves the front-bach sound localization characteristics much better than the conventional methods.

Gravimetric Terrain Correction using Triangular Element Method (삼각요소법을 이용한 중력자료의 지형보정)

  • Rim, Hyoung-Rea;Lee, Heui-Soon;Park, Young-Sue;Lim, Mu-Taek;Jung, Hyun-Key
    • Geophysics and Geophysical Exploration
    • /
    • v.13 no.2
    • /
    • pp.169-174
    • /
    • 2010
  • We developed a precise terrain correction program using triangular element method (TEM) for microgravity data processing. TEM calculates gravity attraction of arbitrary polyhedra whose surface is patched by triangles. We showed that TEM can calculate more precise terrain effect than conventional rectangular prism method. We tested the accuracy of TEM on the cone model which has analytic solution. Also, we tested the accuracy of TEM on the slope model, this results showed that there are big differences calculated by TEM and rectangular prsim method (RPM) on slope model. The developed terrain correction program was applied on the gravity data on the southern area near sea shore of Korean peninsula, calculated terrain effect very precisely.

Variation in Microstructural Homogeneity and Mechanical Properties of Extruded Mg-5Bi Alloy Via Controlling Billet Shape (빌렛 형상 제어를 통한 Mg-5Bi 합금 압출재의 조직 균일도 및 기계적 물성 변화)

  • Jin, S.C.;Cha, J.W.;Park, S.H.
    • Transactions of Materials Processing
    • /
    • v.31 no.6
    • /
    • pp.344-350
    • /
    • 2022
  • Extruded Mg-Bi binary alloys are known to have an undesirable bimodal grain structure containing a large amount of coarse unrecrystallized grains. Accordingly, to improve the microstructural homogeneity of extruded Mg-Bi alloys, it is necessary to promote the dynamic recrystallization (DRX) behavior during hot extrusion. An effective way to promote DRX is an increase in nucleation sites for DRX through a pre-deformation process before extrusion, such as cold pre-forging and hot pre-compression. However, the application of these pre-deformation processes increases the cost of final extruded Mg products because of an increase in energy consumption and decrease in productivity. Therefore, a low-cost new continuous process with high productivity is required to improve the microstructural homogeneity and mechanical properties of extruded Mg alloys without a drastic increase in the entire process cost. This study proposes a new extrusion method using an extrusion billet with a truncated cone shape (i.e., tapered billet) instead of a conventional extrusion billet with a cylindrical shape. When the hot extrusion of a Mg-5Bi alloy is conducted using the tapered billet, the DRX behavior during extrusion is considerably promoted. The DRX fraction and average grain size of the extruded alloy significantly increase and decrease from 65% to 91% and from 225 ㎛ to 49 ㎛, respectively. Consequently, the extruded Mg-5Bi alloy fabricated using the tapered billet has a finer homogeneous grain structure and higher tensile elongation than the extruded counterpart fabricated using the cylindrical billet.

Clinical and radiographic features of facial cosmetic materials: A systematic review

  • Alsufyani, Noura;Aldosary, Reem;Alrasheed, Rasha;Alsufyani, Mohammed
    • Imaging Science in Dentistry
    • /
    • v.52 no.2
    • /
    • pp.155-164
    • /
    • 2022
  • Purpose: The aim of this study was to systematically screen the literature for studies reporting cosmetic material in the oral and maxillofacial complex to shed light on the types of cosmetic materials, their radiographic appearance, and possible complications. Materials and Methods: Five electronic databases were reviewed for eligible studies. The general search terms were "cosmetic," "filler," "face," and "radiograph." Demographics, material types, clinical and radiographic presentation, and complications were recorded. Results: Thirty-one studies with 53 cases met the inclusion criteria. The mean age was 52.6±15.4 years with a 4 : 3 female-to-male ratio. The most common material was calcium hydroxyapatite (CaHa) (n=14, 26.4%), found incidentally. The materials were generally located within the upper cheek and zygoma (n=35, 66.0%), radiographically well-defined (n=44, 83%), and had no effects on the surrounding structures (n=27, 50.9%). The internal structure was radiopaque (calcification, hyperdensity) for gold wires, CaHa, bone implants, and secondary calcification or ossification. Outdated cosmetic materials or non-conservative techniques were infiltrative, had effects on the surrounding structures, and presented with clinical signs, symptoms, or complications. Conclusion: Conventional radiography, cone-beam computed tomography, and multi-detector computed tomography are useful to differentiate several cosmetic materials. Their magnetic resonance imaging appearance was highly variable. The infrequent inclusion of cosmetic materials in the differential diagnosis implies that medical and dental specialists may be unfamiliar with the radiographic appearance of these materials in the face.

Consideration of root position in virtual tooth setup for extraction treatment: A comparative study of simulated and actual treatment results

  • Mirinae Park;Veerasathpurush Allareddy;Phimon Atsawasuwan;Min Kyeong Lee;Kyungmin Clara Lee
    • The korean journal of orthodontics
    • /
    • v.53 no.1
    • /
    • pp.26-34
    • /
    • 2023
  • Objective: The purpose of the present study was to compare the root positions in virtual tooth setups using only crowns in a simulated treatment with those achieved in the actual treatment. Methods: Pre- and post-treatment intraoral and corresponding cone beam computed tomography (CBCT) scans were obtained from 15 patients who underwent orthodontic treatment with premolar extraction. A conventional virtual tooth setup was used for the treatment simulation. Pre- and post-treatment three-dimensional digital tooth models were fabricated by integrating the patients' intraoral and CBCT scans. The simulated root positions in the virtual setup were obtained by merging the crown in the virtual setup and root in the pre-treatment tooth model. The root positions of the simulated and actual post-treatment tooth models were compared. Results: Differences in root positions between the simulated and actual models were > 1 mm in all teeth, and statistically significant differences were observed (p < 0.05), except for the maxillary lateral incisors. The differences in the inter-root angulation were > 1° in all teeth, and statistically significant differences were observed in the maxillary and mandibular canines. Conclusions: The virtual tooth setup using only crown data showed errors over the clinical limits. The clinical application of a virtual setup using crowns and roots is necessary for accurate and precise treatment simulation, particularly in extraction treatment.

A Study on Enhancement of 3D Sound Using Improved HRTFS (개선된 머리전달함수를 이용한 3차원 입체음향 성능 개선 연구)

  • Koo, Kyo-Sik;Cha, Hyung-Tai
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.6
    • /
    • pp.557-565
    • /
    • 2009
  • To perceive the direction and the distance of a sound, we always use a couple of information. Head Related Transfer Function (HRTF) contains the information that sound arrives from a sound source to the ears of the listener, like differences of level, phase and frequency spectrum. For a reproduction system using 2 channels, we apply HRTF to many algorithms which make 3d sound. But it causes a problem to localize a sound source around a certain places which is called the cone-of-confusion. In this paper, we proposed the new algorithm to reduce the confusion of sound image localization. The difference of frequency spectrum and psychoacoustics theory are used to boost the spectral cue among each directions. To confirm the performance of the algorithm, informal listening tests are carried out. As a result, we can make the improved 3d sound in 2 channel system based on a headphone. Also sound quality of improved 3d sound is much better than conventional methods.

HRTF Enhancement Algorithm for Stereo ground Systems (스테레오 시스템을 위한 머리전달함수의 개선)

  • Koo, Kyo-Sik;Cha, Hyung-Tai
    • The Journal of the Acoustical Society of Korea
    • /
    • v.27 no.4
    • /
    • pp.207-214
    • /
    • 2008
  • To create 3D sound, we usually use two methods which are two channels or multichannel sound systems. Because of cost and space problems, we prefer two channel sound system to multi-channel. Using a headphone or two speakers, the most typical method to create 3D sound effects is a technology of head related transfer function (HRTF) which contains the information that sound arrives from a sound source to the ears of the listener. But it causes a problem to localize a sound source around a certain places which is called cone-of-confusion. In this paper, we proposed the new algorithm to reduce the confusion of sound image localization. HRTF grouping and psychoacoustics theory are used to boost the spectral cue with spectrum difference among each directions. Informal listening tests show that the proposed method improves the front-back sound localization characteristics much better than conventional methods.

Usability assessment of thermoplastic Bolus for skin VMAT radiotherapy (피부 병변에 대한 VMAT 치료 시 열가소성 bolus의 유용성 평가: case review)

  • Kim, Min Soo;Kim, Joo Ho;Shin, Hyun Kyung;Cho, Min Seok;Park, Ga Yeon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.85-92
    • /
    • 2020
  • Purpose: To find out the advantages of thermoplastic bolus compared to conventional bolus, which is mainly used in clinical practice, We evaluated Two cases in terms of dose and location reproducibility to assess Usability of thermoplastic Bolus for skin VMAT radiotherapy. Materials and Methods: Two patient's treated with left breast skin lesion were simulated using thermoplastic Bolus and planned with 2arc VMAT. the prescription dose was irradiated to 95% or more of the target volume. We evaluated The reproducibility of the bolus position by measuring the length of the air gap in the CBCT (Cone Beam CT) image. to evaluate dose reproducibility, we compared The dose distribution in the plan and CBCT and measured in vivo for patient 2. Results: The difference between the air gap in patient 1's simulation CT and the mean air gap (M1) during 10 treatments in the CBCT image was -0.42±1.24mm. In patient 2, the difference between the average air gap between the skin and the bolus (M2) during 14 treatments was -1.08±1.3mm, and the air gap between the bolus (M3) was 0.49±1.16. The difference in the dose distribution between Plan CT and CBCT was -1.38% for PTV1 D95 and 0.39% for SKIN (max) in patient 1. In patient 2, PTV1 D95 showed a difference of 0.63% and SKIN (max) -0.53%. The in vivo measurement showed a difference of -1.47% from the planned dose. Conclusion: thermoplastic Bolus is simpler and takes less time to manufacture compared to those produced by 3D printer. Also compared to conventional bolus, it has high reproducibility in the set-up side and stable results in terms of dose delivery.