• Title/Summary/Keyword: conventional cone

Search Result 187, Processing Time 0.027 seconds

Immediate Connection of Customized Zirconia Abutment Using Flapless Guided Surgery: A Clinical Report (무절개 수술을 이용한 맞춤형 지르코니아 지대주의 즉시 장착 증례)

  • Lee, Gyeong-Je;Choi, Byung-Ho;Kim, Hee-Jun;Jung, Seng-Mi
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.2
    • /
    • pp.201-212
    • /
    • 2012
  • There are some similar aspects at histological and morphological characteristics between the peri-implant tissue and periodontal tissue and the direct attachment between the titanium and soft tissue around the implant called as "Functional ankylosis" can prevent the apical infiltration of inflammatory and bone resorption around implant. But, the repeated connection and disconnection of the abutment can destroy the mucosal barrier of soft tissue around the implant and can cause the marginal bone resorption. The amount of marginal bone resorption may reduced if the prosthetic abutment is placed at that time of surgery. Connection of the prosthetic abutment at surgery was limited because the low accuracy of conventional method, but by using of Cone Beam Computed Tomography(CBCT) and guide surgery, the 3-dimensional accuracy of implant placement became much higher than before and it became possible. This is a clinical case of immediate connection of prosthetic abutment and provisional restoration by using of precise CBCT diagnosis and pre-fabricated zirconia customized abutment at surgery and the alternative method is described in this article because of the clinically contentable results.

Parametric Studies for Measurements of Dynamic Properties of Soils Using Inhole type CPTu (인홀형 탄성파콘 시험 결과에 미치는 변수 연구)

  • Jang, In-Sung;Kwon, O-Soon;Kim, Byoung-Il;Lee, Seung-Hyun
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.20 no.6
    • /
    • pp.523-531
    • /
    • 2008
  • In hole type CPTu equipment which combines the concepts of inhole test method and piezocone test method was newly developed in order to evaluate the dynamic properties of marine soils. It is possible to perform inhole type CPTu without any additional source device because the source and receiver are contained inside the cone rod, which is different from the conventional seismic cone system. In this study, laboratory tests using kaolinite as soft soil and numerical simulations using finite element method were carried out to investigate the effects of several parameters including test methods and soil conditions on the test results from inhole type CPTu and to find out the optimum test method. It was found that it is necessary to maintain the length of swing arm as well as the distance between source and receiver consistently to obtain the rigorous test results. The laboratory test and numerical results also reveal that contrary to the input wave frequency, the water content of soil layer and the disturbance due to the installation of swing arm apparently affect the shear wave velocity.

Improvement of Light Extraction Efficiency of GaN-Based Vertical LED with Microlens Structure

  • Kwon, Eunhee;Kang, Eun Kyu;Min, Jung Wook;Lee, Yong Tak
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.221-221
    • /
    • 2013
  • Vertical LED (VLED) has been recognized as a way to obtain the high-power LED due to their advantages [1]. However, approximately 4% of the light generated from the active region is extracted, if the light extraction from side walls and back side is neglected because of Fresnel reflection (FR) and total internal reflection (TIR) [2,3]. In this study, the optical simulation of the VLED with the various microstructures was performed. Among them, the microlens having the diameter of 3 ${\mu}m$ and the height of 1.5 ${\mu}m$ shown the best result was chosen, and then, optimized microlens was formed on a GaN template using conventional semiconductor process. Various microstructures were proposed to improve the light extraction efficiency (LEE) of the VLED for the simulation. The LEE was simulated using LightTools based on a Monte Carlo ray tracing. The microstructures with hemisphere, cone, truncated and cylinder pattern having diameter of 3 ${\mu}m$ were employed on the top layer of the VLED respectively. The improvement of the LEE by using the microstructure is 87% for the hemisphere, 77% for the cone, 53% for the truncated, 21% for the cylinder, compared with the LEE of the flat surface at the reflectance of 85%. The LEE was increased by 88% at the height of 1.5 ${\mu}m$, compared with the LEE of the flat surface. We found that the microlens on the top layer is the most suitable for increasing the LEE. In order to apply the proposed microlens on n-GaN surface, we fabricated microlens on a GaN template. A photoresist array having hexagonal-closed packed microlens was fabricated on the GaN template. Then, optimization of etching the GaN template was performed using a dry etching process with ICP-RIE. The dry etching carried out using a gas mixture of Cl2 and Ar, each having a flow rate of 16 sccm and 10 sccm, respectively with RF power of 50 W, ICP power of 900 W and chamber pressure of 2 mTorr was the optimum etching condition as shown in Fig. 2(a).

  • PDF

Effect of the Addition of Binders on the Fuel Characteristics of Wood Pellets (바인더의 첨가가 목재 펠릿의 연료적 특성에 미치는 영향)

  • Ahn, Byoung Jun;Chang, Hee-Sun;Cho, Seong Taek;Han, Gyu-Seong;Yang, In
    • Journal of the Korean Wood Science and Technology
    • /
    • v.41 no.6
    • /
    • pp.475-489
    • /
    • 2013
  • This work was conducted to investigate the effect of the addition of binders, such as rapeseed flour, coffee waste, bark, pine cone and lignin powder, on the fuel characteristics of the pellets fabricated with larch and tulip tree sawdust. Moisture content, bulk density and higher heating value of most pellets fabricated with the binders exceeded the 1st-grade pellet standard designated by Korea Forest Research Institute, but ash content of the pellets fabricated with rapeseed flour or bark of 10 wt% on the dry weight basis of sawdust was satisfied with just the 2nd- or 3rd-grade standard. The durability of tulip tree-pellets was positively influenced by the addition of rapeseed flour, coffee waste or lignin powder and increased with increasing the amount of the binders. For larch-pellets, the increase of binders did not greatly affect the durability, and even the durability reduced with the increase of bark or pine cone. From the microscopic observation, the obvious feature of pellet surfaces was not identified by the type of binder but by the addition amount of the binder. In summary, the addition of binders contributed to the fuel characteristics of wood pellets, and particularly the characteristics of wood pellets fabricated with coffee waste improved greatly. Therefore, if the binders are secured sufficiently with a reasonable cost, it might be possible to commercialize wood/binder pellets, which have better fuel characteristics than conventional wood pellets.

Comparison of Linac-based VMAT Stereotatic Radiosurgery and Conventional Stereotatic Radiosurgery for Multiple Brain Lesions (Linac 기반 VMAT 정위적 수술 뇌 병변 연구와 기존의 정위적 방사선 수술 비교)

  • Jang, Eun-Sung;Chang, Bo-Seok
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.239-246
    • /
    • 2021
  • Portal Dosimetry was verified using EPID to secure the clinical application and reliability of the existing research dose evaluation. The dose distribution of Geant4 was compared with the measured value by 360° rotational irradiation with a 2.5 cm cone for stereotactic brain surgery. To confirm the dose distribution of patients with brain metastasis, the dose distribution investigated by inserting a Gafchromic EBT film into the parietal phantom and the dose distribution obtained from the parietal phantom using VMAT are compared and applied to actual patients. As a result of the analysis, it was confirmed that the accuracy of the beam center and the center of the couch coincide accurately with an error within 1mm as a result of QA through a pin ball. In addition, it was confirmed that the EBT3 film has excellent linearity in the range of 0 to 10 Gy according to various dose irradiation. In the same setting as the two cervical phantoms, we confirm that the implementation and simulation results calculations of dose calculations based on Geant4 using photon beams match the experimental data within the treatment planning volume (PTV). Therefore, volume modulated arc treatment (VMAT) 360° rotational irradiation was performed, and the result of iso-dose distribution analysis by rotational irradiation confirmed that it is appropriate to include a virtual tumor.

Analysis of Effective Improvement Depth for Establishing Quality Control Criteria of Rapid Impact Compaction for Public Fill Compaction (Public Fill 다짐 시 급속충격다짐공법의 품질관리기준 수립을 위한 유효개량심도 분석)

  • Kim, Kyu-Sun;Park, Jaeyoung;Kim, Hayoung
    • Journal of the Korean Geotechnical Society
    • /
    • v.39 no.10
    • /
    • pp.5-18
    • /
    • 2023
  • The construction timeline for earthworks can be significantly reduced by substituting the conventional layer-by-layer compaction using a vibratory roller with single-layer compaction through the rapid impact compaction (RIC) method. Dynamic load compaction is well-suited for coarse-grained soils like sand. However, as the supply of sand, the primary reclamation material, becomes scarcer, the utilization of soil with fines is on the rise. To implement the dynamic load compaction, such as RIC, with reclaimed materials containing fines, it's imperative to determine the effective improvement depth. In this study, we assess the impact of the RIC method on the effective improvement depth for clean sand and public fill with fines, comparing field test results before and after RIC application. Our focus is on the cone resistance (qc) as it pertains to compaction quality control criteria. In conclusion, it becomes evident that standardizing the cone resistance is vital for the quality control of various reclaimed soils with fines. We have evaluated the compaction quality control criteria corresponding to a relative density (Dr) of 70% for clean sand as Qtn,cs = 110. As a result of this analysis, we propose new quality control criteria for qc, taking into account the fines content of reclaimed soils, which can be applied to RIC quality control.

Study on Wet Electric Precipitation with Electrospray for Removal of PM1.0 in Exhaust Gas (배가스 내 PM1.0 미세먼지 제거를 위한 정전분무 습식 전기집진기에 대한 연구)

  • Cho, Yeonjoo;Lim, Hyunjeong;Kim, Soyeon;Choi, Sangmi;Jeong, Min Kyu;Kim, Minsung
    • Plant Journal
    • /
    • v.16 no.1
    • /
    • pp.34-37
    • /
    • 2020
  • The need to improve the performance of the dust collector by increasing the fine dust pollution in Korea is eminent. In this study, electrostatic spray wet electrostatic precipitator is used to remove Particulate Matter (PM). In order to enter the Cone-jet mode, which is the most stable spray mode among the various modes of electrostatic spraying, an appropriate voltage-flow condition must be satisfied, and a voltage-flow interval enabling this can be expressed as Stability Island. The voltage at which the conduit mode starts in the Stability Island section is referred to as the electrostatic spray minimum voltage (Onset Voltage). However, the conventional electrostatic spray is uses a very low flowrate, at most few millilitres per minute. The use of much higher flowrates has introduced different patterns of electrospray modes. In this study, the different spray modes will be studied in detail.

Bone regenerative effect of recombinant human bone morphogenetic protein-2 after cyst enucleation

  • Hwang, Doo Yeon;On, Sung Woon;Song, Seung II
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.38
    • /
    • pp.22.1-22.6
    • /
    • 2016
  • Background: The aim of this study is to quantitatively evaluate the effect of rhBMP-2 for repair of bone defects after cyst enucleation using the osteogenesis index (OI). Methods: Under general anesthesia, 10 patients (12 lesions) underwent oral or maxillofacial surgery for cyst enucleation. Postoperatively, 12 lesions were divided into two groups: group A (six lesions) was treated with absorbable collagen sponge (ACS) in combination with rhBMP-2, and group B (six lesions) was treated with ACS alone. After 3 months, cone-beam computed tomographic scans were obtained to measure changes in the volume of the lesions. We then calculated the OI of each group at two different Hounsfield units to determine any statistically significant difference between these two groups (Mann-Whitney U test). Results: As tested at the level of new bone, the mean OI was 72.37 % in group A and 55.08 % in group B -a statistically significant difference (p = 0.041). As tested at the level of mature bone, the mean OI was 27.47 % in group A and 18.88 % in group B, but the difference was not statistically significant (p = 0.394). Conclusions: The application of rhBMP-2 after maxillofacial cyst enucleation accelerated new bone formation in the bone defects. Thus, the use of rhBMP-2 in combination with ACS may be considered an alternative to conventional bone grafting in some patients with postoperative bone defects.

Fabrication of Piezoelectric Cantilever with Microcone Tip for Sensing Local Stiffness of Biological Tissue (생체 조직의 국소 강도 측정을 위한 마이크로 콘 팁을 가진 압전 캔틸레버 제작)

  • Roh, Hee Chang;Yang, Dasom;Ryu, WonHyoung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.11
    • /
    • pp.743-748
    • /
    • 2017
  • For diseases that are difficult to detect by conventional imaging techniques, the development of a diagnostic method that allows sensors to be inserted into the human body to aid the diagnosis of local spots of the target tissue, is highly desirable. In particular, it is extremely difficult to determine whether vulnerable plaque can later develop into atherosclerosis using only imaging techniques. However, vulnerable plaques are expected to have slightly different mechanical properties than healthy tissue. In this study, we aim to develop a piezoelectric cantilever-type sensor that can be inserted into the human body and can detect the local mechanical properties of the target tissue. A piezoelectric polymer composite based on $BaTiO_3$ nanoparticles was optimized for fabrication of a piezoelectric cantilever. Next, a micro-cone tip was fabricated at the end of the piezoelectric cantilever by thermal drawing. Finally, stiffness of biological tissue samples was measured with the piezoelectric cantilever sensor for verifying its functionality.

Rebinning-Based Deterministic Image Reconstruction Methods for Compton Camera (컴프턴 카메라를 위한 재배열 기반 확정론적 영상재구성법)

  • Lee, Mi-No;Lee, Soo-Jin;Seo, Hee;Nguyen, Van-Giang
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.1
    • /
    • pp.15-24
    • /
    • 2011
  • While Compton imaging is recognized as a valuable 3-D technique in nuclear medicine, reconstructing an image from Compton scattered data has been of a difficult problem due to its computational complexity. The most complex and time-consuming computation in Compton camera reconstruction is to perform the conical projection and backprojection operations. To alleviate the computational burden imposed by these operations, we investigate a rebinning method which can convert conical projections into parallel projections. The use of parallel projections allows to directly apply the existing deterministic reconstruction methods, which have been useful for conventional emission tomography, to Compton camera reconstruction. To convert conical projections into parallel projections, a cone surface is sampled with a number of lines. Each line is projected onto an imaginary plane that is mostly perpendicular to the line. The projection data rebinned in each imaginary plane can then be treated as the standard parallel projection data. To validate the rebinning method, we tested with the representative deterministic algorithms, such as the filtered backprojection method and the algebraic reconstruction technique. Our experimental results indicate that the rebinning method can be useful when the direct application of existing deterministic methods is needed for Compton camera reconstruction.