• Title/Summary/Keyword: convective conditions

Search Result 214, Processing Time 0.026 seconds

COMPUTATIONAL ANALYSIS FOR IMPROVING UNIFORMITY OF $SNO_2$ THIN FILM DEPOSITION IN AN APCVD SYSTEM ($SnO_2$ 박막증착을 위한 APCVD Reactor 내 유량 균일도 향상에 대한 수치 해석적 연구)

  • Park, J.W.;Yoon, I.R.;Chung, H.S.;Shin, S.W.;Park, S.H.;Kim, H.J.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.567-570
    • /
    • 2010
  • With continuously increasing flat panel display size, uniformity of thin film deposition has been drawing more attentions and associated fabrication methodologies are being actively investigated. Since the convective flow field of mixture gas plays a significant role for deposition characteristics of thin film in an APCVD system, it is greatly important to maintain uniform distribution and consistent concentration of mixture gas species. In this paper, computational study has been performed for the improvement of flow uniformity of mixture gas in an APCVD reactor during thin film deposition process. A diffuser slit has bee designed to spread the locally concentrated gas flow exiting from the flow distributor. A uniform flow distributor has been developed which has less dependency on operating conditions for global flow uniformity

  • PDF

The Effects of Heat Diffusion Fin on the Thermal Behavior and Performance of Radiant Heatomg Panel (방열핀이 난방용 패널의 열적거동 및 성능에 미치는 영향)

  • 이태원
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.9
    • /
    • pp.2486-2493
    • /
    • 1994
  • Transient heat transfer characteristics in th radiant heating panel with heat diffusion fin were predicted by numerical analysis. Thermal behaviors of panel, such as temperature distributions in panel and convective and radiative heat fluxes in panel surface with advance of time, were obtained for several important parameters. The performance and thermal comfort of heating panel were studied and compared for various design conditions, such as pipe pitch, area ratio and thermal conductivity of optimal design of the new heating panels with heat diffusion fin. It was concluded that the efficient area ratio of heat diffusion fin is about 0.5, and the greater the thermal conductivity of fin is, the better the performance of panel is.

Approximate Solution of Absorption Process in an Air-Cooled Vertical Plate Absorber (공냉식 수직평판형 흡수기의 흡수과정에 대한 근사해법)

  • Jeong, E.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.4
    • /
    • pp.453-462
    • /
    • 1994
  • An unsteady quasi one-dimensional model of momentum, heat and mass transfer in a falling film of a vertical plate absorber which is cooled by air was developed using the integral method. Energy conservation of the absorber wall is considered in the model. The model can predict absorption rate, film thickness and mean velocity as well as concentration and temperature profiles. Predictions of steady state temperature and concentration profiles for LiBr/water system for constant wall temperature condition are in good agreement with the two-dimensional finite difference method solutions. Effects of operating conditions, such as convective heat transfer coefficient between the cooling air and the absorber wall, cooling air temperature and film thickness at inlet, on absorption rate of water vapor into LiBr/water solution were shown.

  • PDF

Buoyant Convection in a Cylinder with Azimuthally-varying Sidewall Temperature (방위각방향 온도변화를 가지는 실린더 내의 부력 유동)

  • Chung, K.H.;Hyun, J.M.;Song, T.H.
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.45-50
    • /
    • 2000
  • A numerical investigation is made of three-dimensional buoyant convection of a Boussinesq-fluid in a vertical cylinder. The top and bottom endwalls are thermally insulated. Flow is driven by the substantial azimuthal variations in thermal boundary conditions. Comprehensive numerical solutions to the Navier-Stokes equations are obtained. The representative Rayleigh number is large, thus, the overall flow pattern is of boundary layer-type. Three-dimensional (low characteristics are described. Specially, the global flow and the heat transfer features are delineated when the severity of azimuthal variation of sidewall temperature n, is intensified. Temperature and velocity fields on the meridional planes and the planes of constant height are presented. The global flow weakens as n becomes large. The pattern of the local Nusselt number on the surface of cylinder is similar regardless of n. The convective gain in heat transfer activities is reduced as n increases.

  • PDF

Experimental and Numerical Study on Characteristics of Air-assisted Spray and Spray Flames (2유체 분무의 연소특성에 관한 실험 및 수치 해석적 연구)

  • Kim, Dong-Il;Oh, Sang-Huen
    • Journal of the Korean Society of Combustion
    • /
    • v.3 no.2
    • /
    • pp.51-63
    • /
    • 1998
  • Air-assisted atomizer flames are investigated numerically to study spray structures in nonburning and burning conditions based on experimental data. A PDA is used to measure droplet size, velocity, and number density for both nonburning and burning spray. Computations utilize time-averaged gas-phase equations and $k-{\varepsilon}$ turbulence model for simplicity. The major features of the liquid-phase model are that a SSF approach is used to represent the effect of gas-phase turbulence on droplet trajectories and vaporization, an infinite-diffusion model is employed to represent the transient liquid-phase process. Computation and experiment results show that the droplet acceleration and evaporation proceed quickly in near the atomizer, characterizing high number densities and a strong convective effect. The primary combustion zone, however, is dorminated by the gas phase reaction and exhibits a sheath combustion.

  • PDF

Stability Analysis of Marangoni Convection for $NH_3\;-H_2O$ Absorption Process (전파이론을 통한 $NH_3\;-H_2O$ 흡수과정의 마란고니 대류 안정성 해석)

  • 최창균;김제익;강용태
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.6
    • /
    • pp.450-455
    • /
    • 2002
  • Convective instability driven by surface tension is analyzed in an initially quiescent water absorbing ammonia gas using the linear stability theory. The propagation theory is adapated to find the critical conditions of the onset of solutal Maragoni convection. In this theory, the solutal penetration depth is chosen as the length scale factor. The results show that the liquid layer becomes more stable with decreasing the Schmidt number It is interesting that for a smaller Biot number than 100, the system becomes stable with decreasing Bi but for a larger Bi, it becomes unstable with decreasing Bi.

PRELAUNCH THERMAL ANALYSIS OF KSLV-I PAYLOAD FAIRING

  • Choi Sang-Ho;Kim Seong-Lyong;Kim Insun
    • Bulletin of the Korean Space Science Society
    • /
    • 2004.10b
    • /
    • pp.356-359
    • /
    • 2004
  • Prelaunch thermal analysis of the KSLV (Korea Space Launch Vehicle)-I PLF (Payload Fairing) was performed to predict maximum/minimum liftoff temperatures and to evaluate of air conditioning performance. Prelaunch thermal analysis includes internal air conditioning effect, external convective heating/cooling, radiation exchange with the ground and sky, radiation between spacecraft and PLF, and solar radiation incident on PLF. Analysis was performed at two extreme conditions, hot day condition and cold day condition. The results showed that the maximum liftoff temperature was $53^{\circ}C$ and the minimum liftoff temperature was $-3.8^{\circ}C$. It was also found that conditioned air supplying, in $20{\pm}2^{\circ}C\;and\;1200\;m^3/hr$, is sufficient to keep the internal air in required temperature range.

  • PDF

Wolf-Rayet star evolution with clumpy envelope structure

  • Jang, Hye-Eun;Yoon, Sung-Chul
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.1
    • /
    • pp.42.2-42.2
    • /
    • 2016
  • It is well known that theoretical models of Wolf-Rayet stars are not consistent with observational data in terms of temperature and stellar radius. Recent study in analytical and numerical simulations show the importance of density inhomogeneity in stellar envelope. Using 1-dimensional numerical simulations, we study how such clumpiness arisen over convective surface of Wolf-Rayet stars affect their evolutionary path. Starting from pure helium star models, we constructed 21 different initial conditions by varying stellar mass, metallicity, and the clumpiness of the sub-surface convection zone. We run the simulations until the oxygen-burning is reached and find that the influence of the clumpiness is sensitive to the initial metallicity. Our models with high metallicity including the effect of the density inhomogeneity can roughly explain the observed properties of Wolf-Rayet stars such as stellar radius and temperature. By contrast, despite a considerable amount of density inhomogeneity is given, low metallicity models could not fully explain observations. To understand the inconsistency in low metallicity models, detailed study with improved model is required, taking account of the error range of the observations.

  • PDF

A Study on Response Time Index for Sprinkler Head (스프링클러 헤드의 응답시간지수 측정)

  • 태순호;이병곤
    • Journal of the Korean Society of Safety
    • /
    • v.5 no.3
    • /
    • pp.51-55
    • /
    • 1990
  • This study describes the engineering approach adopted to investigate sprinkler head during the early stage of a fire when they are subjected to convective heating and low gas velocities. Comparions are made between the parameters derived using basic methods, ie. ramp test, for evaluating sprinkler parameters(time constant, response time index) is illustrated. Evidence is presented that the propotion of heat loss by conduction from a sprinkler element may very typically employed in the rate of rise test. This fact alone may justfy the precautionary need to perform a limited number of rate of rise tests to confirm a sprinklers capacity to function correctly in reasonably unfavourable yet realistic conditions. The work is aimed primarily at meeting the needs of sprinkler industry.

  • PDF

Condensation Heat Transfer Correlation for Smooth Tubes in Annular Flow Regime

  • Han Dong-Hyouck;Moon C.;Park C.;Lee Kyu-Jung
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.8
    • /
    • pp.1275-1283
    • /
    • 2006
  • Condensation heat transfer coefficients in a 7.92 mm inside diameter copper smooth tube were obtained experimentally for R22, R134a, and R410A. Working conditions were in the range of $30-40^{\circ}C$ condensation temperature, $95-410 kg/m^2s$ mass flux, and 0.15-0.85 vapor quality. The experimental data were compared with the eight existing correlations for an annular flow regime. Based on the heat-momentum analogy, a condensation heat transfer coefficients correlation for the annular flow regime was developed. The Breber et al. flow regime map was used to discern flow pattern and the Muller-Steinhagen & Heck pressure drop correlation was used for the term of the proposed correlation. The proposed correlation provided the best predicted performance compared to the eight existing correlations and its root mean square deviation was less than 8.7%.