• Title/Summary/Keyword: control vibration

Search Result 4,111, Processing Time 0.03 seconds

Electrical Noise Reduction in the Electromagnetic Shaker System using a Class-D Amplifier (Class-D 증폭기를 사용한 가진기 시스템의 전기적 잡음 감소)

  • 윤을재;김인식;한태균
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.3 no.4
    • /
    • pp.12-22
    • /
    • 1999
  • Operation of an electromagnetic shaker system using a Class-D amplifier may cause unacceptable electromagnetic interference to another electronic system, requiring the user to take whatever steps are necessary to correct the interference. A differential amplifier in a Class-D amplifier is used to decrease the effect of a common-mode noise voltage in a shaker system. To prevent a ground loop, a transformer is inserted in another shaker system. These methods show reduction of the unwanted vibration which has occurred before. A transformer in a charge amplifier was used to prevent a ground loop in a shaker system using a Class-AB amplifier a few years ago, but it was susceptible of noise in a shaker system using a Class-D amplifier. Hence we corrected a ground loop between a charge amplifier and a vibration control/analysis system without a transformer. The usefulness of this approach is illustrated by the results of experiments.

  • PDF

Optimum Design of Viscoelastic Layered Beam to Minimize Flexural Vibration (굽힘진동 감쇠를 위한 점탄성 적층보의 최적 설계)

  • Sa-Soo Kim;Dae-Seung Cho;Min-Woo Lee
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.36 no.1
    • /
    • pp.90-98
    • /
    • 1999
  • For the control of vibration and noise of metal structures having relatively low damping, viscoelastic materials are widely used and usually attached at metal structures with an additional constraining layer to secure them. The damping and elastic properties of structures having constrained viscoelastic material layers are dependent on not only temperature and frequency but also their thicknesses. Hence, optimal design of the thicknesses of viscoelastic and constraining layers for a certain base structure are very important to maximize their efficiency and to lighten their weight. In this study, the variation of loss factor of beams having a constrained viscoelastic layer according to the change of thickness has been carefully investigated. From these, optimal design method of the minimum thickness beam having a given loss factor is suggested and numerically verified for a real beam.

  • PDF

Practical countermeasures for the aerodynamic performance of long-span cable-stayed bridges with open decks

  • Zhou, Rui;Yang, Yongxin;Ge, Yaojun;Mendis, Priyan;Mohotti, Damith
    • Wind and Structures
    • /
    • v.21 no.2
    • /
    • pp.223-239
    • /
    • 2015
  • Open decks are a widely used deck configuration in long-span cable-stayed bridges; however, incorporating aerodynamic countermeasures are advisable to achieve better aerodynamic performance than a bluff body deck alone. A sectional model of an open deck cable-stayed bridge with a main span of 400 m was selected to conduct a series of wind tunnel tests. The influences of five practical aerodynamic countermeasures on flutter and vortex-induced vibration (VIV) performance were investigated and are presented in this paper. The results show that an aerodynamic shape selection procedure can be used to evaluate the flutter stability of decks with respect to different terrain types and structural parameters. In addition, the VIV performance of $\prod$-shaped girders for driving comfortableness and safety requirements were evaluated. Among these aerodynamic countermeasures, apron boards and wind fairings can improve the aerodynamic performance to some extent, while horizontal guide plates with 5% of the total deck width show a significant influence on the flutter stability and VIV. A wind fairing with an angle of $55^{\circ}C$ showed the best overall control effect but led to more lock-in regions of VIV. The combination of vertical stabilisers and airflow-depressing boards was found to be superior to other countermeasures and effectively boosted aerodynamic performance; specifically, vertical stabilisers significantly contribute to improving flutter stability and suppressing vertical VIV, while airflow-depressing boards are helpful in reducing torsional VIV.

ALC(Autoclaved Lightweight Concrete) Hardness Prediction by Multiple Regression Analysis (다중회귀분석을 이용한 ALC 경도예측에 관한 연구)

  • Kim, Kwang-Soo;Baek, Seung-Hoon;Chung, Soon-Suk
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.7 no.2
    • /
    • pp.101-111
    • /
    • 2012
  • In the ALC(Autoclaved lightweight concrete) manufacturing process, if the pre-cured semi-cake is removed after proper time is passed, it will be hard to retain the moisture and be easily cracked. Therefore, in this research, we took the research by multiple regression analysis to find relationship between variables for the prediction the hardness that is the control standard of the removal time. We study the relationship between Independent variables such as the V/T(Vibration Time), V/T movement, expansion height, curing time, placing temperature, Rising and C/S ratio and the Dependent variables, the hardness by multiple regression analysis. In this study, first, we calculated regression equation by the regression analysis, then we tried phased regression analysis, best subset regression analysis and residual analysis. At last, we could verify curing time, placing temperature, Rising and C/S ratio influence to the hardness by the estimated regression equation.

  • PDF

Reduction Method of Acoustic Vibrating Plate Using Piezo Electric Material (압전 소자를 이용한 음향 진동 박판에 대한 제어 기법)

  • Jung, Do-Hee;Park, Seen-Ok;Kim, Woo-Young;Lee, Sang-Kee
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.10
    • /
    • pp.777-784
    • /
    • 2003
  • Acoustic response control of a corner-pinned plate using piezoelectric wafers was studied, both theoretically and experimentally Three different sizes of aluminum alloy plates were used and available ball joints were employed to hold the plate at the four corners. The plate with the largest aspect ratio showed the largest and most clear responses to the acoustic excitation in the range of frequencies (0∼200 Hz), and sound pressure levels (80∼100 dB) as predicted. The reduction of the acoustic response of the plate by piezoelectric actuator was very significant, more than expected, but abatement of the sound transmission through the plate was only slightly altered by the piezoelectric actuator. This work is an original work extending earlier work with doors excited by acoustic fields. The important difference is the used of ball joints to simulate the joints.

Questionnaire Study Conducted Around Gimpo International Airport by Using THI - Comparison with the Responses of the Residents at Gimpo and Futenma, Okinawa - (THI를 이용한 항공기 소음이 주민 건강상태에 미치는 영향 연구 - 김포공항과 오키나와 Futenma 공항 주변 주민들에 대한 비교 -)

  • Son, Jin-Hee;Lee, Kun;Lee, Seung-Wook;Chang, Seo-Il
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.6
    • /
    • pp.624-631
    • /
    • 2008
  • This study evaluates the impact of aircraft noise on people's health using the Todai health index(THI). A questionnaire survey was conducted in the vicinity of Gimpo International Airport in Seoul, South Korea, from August 8th to September 9th, 2005. The survey area was divided into three groups based on different aircraft noise levels : area (1) for $80{\sim}85$ WECPNL, area (2) for $75{\sim}80$ WECPNL and area (3) for less than 75 WECPNL. In each area, approximately 200 respondents were sampled. Twelve scale scores of THI are converted to dichotomous variables based on scale scores of 90 percentile value or 10 percentile value in the control group. Logistic regression analysis taking twelve scores converted as the dependent variables and WECPNL(area), age, gender as the independent variables is conducted. Significant dose-response relationships are found in the scale of MOUT, DEPR, NERV, LIFE. Factor analysis was carried out and 2 factors are extracted. Those two factors might be called the "somatic factor" and the "mental factor". The dose-response relationship between two factors and noise seems to be unclear. Unexpectedly the odds ratio of the menatl factor in area (2), where the noise exposure level is lower than that of the area (1), is the highest and the annoyance in this area is also higher than area (1).

An Experimental Study of Squeal Noise Characteristics for Railway Using a Scale Model Test Rig (축소 모델 실험장치를 이용한 철도 스킬소음의 특성에 대한 실험적 연구)

  • Kim, Jiyong;Hwang, Donghyeon;Lee, Junheon;Kim, Kwanju;Kim, Jaechul
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.5
    • /
    • pp.352-360
    • /
    • 2015
  • Squeal noise is a harsh, high-pitched sound that occurs when railways are running at sharp curve tracks. The cause of squeal noise is known to be the transient lateral traction force between wheel and rail. Field measurements are too difficult to control the parameters. Thus, the scaled test rig should have been made in order to investigate the generating mechanism of squeal noise. The unique feature of our test rig, HSTR(Hongik Squeal Testing Rig), is that DOFs of its wheelset are as close to as those of the real railway. The attack angle and running speed of the rail roller are controlled in real time for simulating a transient characteristic of driving curve. The environment conditions, such as given axle load, running speed, and wheel's yaw angle have been identified for generating squeal noise and the squeal noise itself has been measured. The relation between wheel creepage and creep force in lateral direction and the criteria for squeal noise have been investigated, which results has been verified by finite element method.

Safety assessment of Generation III nuclear power plant buildings subjected to commercial aircraft crash Part II: Structural damage and vibrations

  • Qu, Y.G.;Wu, H.;Xu, Z.Y.;Liu, X.;Dong, Z.F.;Fang, Q.
    • Nuclear Engineering and Technology
    • /
    • v.52 no.2
    • /
    • pp.397-416
    • /
    • 2020
  • Investigations of the commercial aircraft impact effect on nuclear island infrastructures have been drawing extensive attention, and this paper aims to perform the safety assessment of Generation III nuclear power plant (NPP) buildings subjected to typical commercial aircrafts crash. At present Part II, based on the verified finite element (FE) models of aircrafts Airbus A320 and A380, as well as the NPP containment and auxiliary buildings in Part I of this paper, the whole collision process is reproduced numerically by adopting the coupled missile-target interaction approach with the finite element code LS-DYNA. The impact induced damage of NPP plant under four impact locations of containment (cylinder, air intake, conical roof and PCS water tank) and two impact locations of auxiliary buildings (exterior wall and roof of spent fuel pool room) are evaluated. Furthermore, by considering the inner structures in the containment and raft foundation of NPP, the structural vibration analyses are conducted under two impact locations (middle height of cylinder, main control room in the auxiliary buildings). It indicates that, within the discussed scenarios, NPP structures can withstand the impact of both two aircrafts, while the functionality of internal equipment on higher floors will be affected to some extent under impact induced vibrations, and A380 aircraft will cause more serious structural damage and vibrations than A320 aircraft. The present work can provide helpful references to assess the safety of the structures and inner equipment of NPP plant under commercial aircraft impact.

Perceptual Evaluation of Noise Sources in a Chamber for Residential and Working Environment (주거 및 사무환경 챔버에서의 생활소음에 대한 감성적 평가)

  • Jeon, Jin-Yong;Kim, Kyong-Ho;Jung, Jeong-Ho;Ryu, Jong-Kwan;Cho, Moon-Jae
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.6
    • /
    • pp.437-444
    • /
    • 2002
  • This paper is to provide the basic way of a acoustical evaluation and efficient control noise by investigating the limits of perceptual loudness of living environment and by finding out any correlation between Physical characteristics of noise and psychoacoustic parameters. The limits of perceptual loudness were selected by the subjects in a chamber for residential and working environment. And the noise sources were analyzed to find out whether there is any correlation with Zwicker parameters and ACF factors. In this study especially, to set up the domestic evaluation grade about floor impact noise. we'd like to suggest the loudness Perception research result as fundamental resource for setting up the evaluation grade through the result that is based on annoyance. In the result of this research, upper limit of heavy-weight impact noise was L-60, and lower limit of it was L-50. On the other hand, upper limit of light-weight impact noise was L-70, and lower limit of it was L-55. It seemed that the loudness of noise from vacuum cleaner noise does not affect its perceived noisiness. Noises implicated In human such as floor walking noise and talking sound, are the most irritating noise in office environment.

Nonlinear Characteristic of a Tuned Liquid Column Damper under Various Excitation Amplitude (가진입력의 크기에 따른 동조액체기둥감쇠기의 비선형 특성)

  • Lee, Sung-Kyung;Lee, Hye-Ri;Min, Kyung-Won
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.11
    • /
    • pp.1167-1176
    • /
    • 2009
  • The objective of this study is to investigate design parameters of a tuned liquid column damper(TLCD), which is affected by various excitation amplitude, through shaking table test. Design parameters of a TLCD are examined based on the equivalent tuned mass damper(TMD) model of a TLCD, in which the nonlinear damping of a TLCD is transposed to equivalent viscous damping. Shaking table test is carried out for a TLCD specimen subjected to harmonic waves with various amplitude. Transfer functions are ratios of liquid displacement of TLCD and control force produced by a TLCD, respectively, with respect to the acceleration excited by a shaking table. They are derived based on the equivalent TMD model of a TLCD. Then, the variation of design parameters according to the excitation amplitude is examined by comparing analytical transfer functions with experimental ones. Finally, the dissipation energy due to the damping of a TLCD, which is experimentally observed from the shaking table test, is examined according to the excitation amplitude. Comparisons between test results and analytical transfer functions showed that natural frequencies of TLCD and the ratio of the liquid mass in a horizontal column to the total liquid mass do not depend on the excitation amplitude, while the damping ratio of a TLCD increases with larger excitation amplitude.