• Title/Summary/Keyword: control vibration

Search Result 4,111, Processing Time 0.037 seconds

The Use of Locally Applied Vibration to Minimize Pain during Fractional CO2 Laser Therapy in Living Liver-Donor Scar Management

  • Song, Sinyoung;Choi, Dong Hoon;Oh, Tae Suk
    • Archives of Plastic Surgery
    • /
    • v.43 no.6
    • /
    • pp.570-574
    • /
    • 2016
  • Background Fractional $CO_2$ laser is an effective treatment for scars, but most patients complain about sharp burning pain, even after the application of lidocaine ointment. This study analyzed the impact of a vibrating device to nonpharmacologically reduce the acute pain of laser treatment, in accordance with the gate control theory of pain management. Methods This is a prospective study performed from May 2013 through March 2014. Fifty-three patients (mean age, 26.7 years; range, 16-44 years) who had donated livers for liver transplantation were treated with a fractional $CO_2$ laser (10,600 nm; model $eCO_2$, Lutronic Corp) for their abdomen scars. Laser treatment was applied 4 months after surgery. A commercially available, locally applied vibrating device (model UM-30M, Unix Electronics Co. Ltd.) was used, in an on-and-off pattern, together with the $CO_2$ laser. A visual analogue scale (VAS; 0, no pain; 10, most severe pain) of pain sensation was assessed and statistically analyzed using a paired t-test. Results The average VAS score for pain with the vibrating device was 4.60 and the average VAS score without the vibrating device was 6.11. The average difference between scores was 1.51 (P=0.001). Conclusions A locally applied vibrating device was demonstrated to be effective in reducing pain when treating with a fractional $CO_2$ laser. Vibration treatment could be helpful when treating scars with fractional $CO_2$ laser in pain-sensitive patients, particularly children.

A Study on Experimental Method of Blasting Vibration in Curing Concrete (양생중인 콘크리트에서의 발파진동의 영향 시험방법에 대한 연구)

  • Kim, Jang-Deuk;Kim, Yong-Ha
    • The Journal of Engineering Geology
    • /
    • v.19 no.3
    • /
    • pp.417-422
    • /
    • 2009
  • Tunnels that have recently been constructed are characterized by longer length than ever before and furthermore they frequently go through the ground area with poor conditions such as fractured zones. If ground strength is weak, plastic deformation of tunnel occurs, and occasionally a big fall may be brought about. Up to now, the construction work of tunneling has been executed as a sequential method placing the lining concrete after completion of excavation. Such a method requires a long time and much money to complete the tunnel. It is hard to ensure the stability of tunnel if tunnel is left undone for a long time after excavation in fracture zones or plastic grounds. For this reason, we tried to take simultaneous construction of tunnel excavation and lining concrete in order to not only shorten construction schedule but also stabilize the tunnel at the highly fractures zone as soon as possible. As preliminary consideration for simultaneous construction, in-situ tests are performed to calculate the isolation distance over which blasting vibration does not influence the strength of lining concrete. Improvement of ling form, placing method of concrete, ventilation using a dust collector, together with equipment arrangement, was made to assure the simultaneous construction work.

Operation Characteristics of the HVAC System Installed in Ancient Tomb (고분내부에 설치된 공조시스템의 운전특성)

  • Jun, Yong-Du;Lee, Kum-Bae;Jun, Hee-Ho;Ko, Seok-Bo;Park, Jin-Yang;Youn, Young-Muk
    • Journal of Energy Engineering
    • /
    • v.15 no.3 s.47
    • /
    • pp.202-208
    • /
    • 2006
  • Although the importance of good conservation of historic sites including ancient royal tombs is well aware, still not much attention has been paid for the facilities and systems to preserve those historic sites, which includes precious artifacts as wall paints and carved works, etc. Even the general understanding about the environment of the underground space or tombs is not satisfactory. In the present study, vibration levels due to the operation of an HVAC system to maintain the desired indoor temperature and humidity are investigated experimentally. According to the measured data, the level of vibration inside the present model tomb with the indoor unit inside, showed order of magnitude less values than the Swiss Standards, but still higher than the value suggested by German standards, which is, zero. Further study will be pursued for cases including different ways of installation, because the vibration level depends not only on the system design, but also on the installation methods.

On the Vibration Control of Ship (선박진동 제어기술에 관한 소고)

  • 이호섭
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1996.04a
    • /
    • pp.11-21
    • /
    • 1996
  • 선박은 화물 및 여객을 수송하는 해상교통 수단으로써 여객 및 승무원의 안락성, 탑재장비, 기기의 성능 보전 상, 화물 및 구조부재의 안전성 차원에서 진동제어가 주요 해결 기술의 하나이다. 또한 최근 선박의 대형화, 고속화로 인해 엔진과 프로펠러의 기진력은 커지는데 반해 구조 강도계산 기술의 발달로 인해 선체구조 경량화가 촉진되어 선체의 유연성이 커질 뿐 아니라 전통적인 선체 구조와 기관, 축계 강성사이의 균형이 깨어짐으로 선박의 진동제어는 더욱 중요시 되고 있다. 선박의 경우 건조 후에 진동제어를 위한 조치를 취하는 일은 매우 제한적이고 많은 비용이 들기 때문에 설계단게에서 선박진동제어를 위한 사전 노력이 충분히 이루어지는 것이 중요하다. 따라서 선박의 주 기진원인 프로펠러, 주기관 등의 기진력 자체를 적정화하는 노력과 함께 그로 인한 응답을 극소화하기 위해 설계 단계부터 인도까지 단게별로 많은 노력을 기울이고 있다. 단계별 진동제어의 한 예를 Fig.1에서 보여주고 있다[1]. 선체와 같이 복잡한 대형구조물의 진동특성 및 응답을 계산함에 있어서 컴퓨터의 발달과 유한요소법과 같은 해석기술의 발달로 실제 구조와 매우 유사한 3차원 모델링이 가능하게 되어 해석의 정도를 높일 수 있게 되었다. 그러나 프로펠러 기진력, 유체와의 연성효과, 감쇠특성 등을 정도 높게 산정하는 데는 아직도 많은 어려움이 있다. 이와같은 문제는 진동응답의 계산정도를 저하시키는 주요 요인이 되어 설게단계에서 충분히 진동 제어가 이루어졌다 하더라도 건조 후 실제운항 시 진동문제가 발생되는 경우가 있다. 건조 후 진동문제 발생시 구조변경을 통한 해결은 한계가 있기 때문에 각종 진동제어 장치의 연구개발이 최근에 활발히 이루어지고 있다[2]. 본 고에서는 설계단계에서부터 건조 후까지의 선박진동제어 과정[1,2,5,6]을 단계별로 고찰하여, 점점 까다로워져 가는 선박 진동규제[3,4]에 대처하고 승무원의 안락성에 대한 욕구, 구조물의 안전성, 장비의 성능보존이 만족되는 저진동 선박의 건조를 위해 향후 해결해야할 과제들을 도출하여 선박진동분야이 연구개발 방향을 제시하고자 한다.

  • PDF

Vibration Control of the Continuous System Under White Noise Disturbance (백색잡음가진을 받는 연속체의 진동제어)

  • Paik, Jong-Han;Heo, Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.116-120
    • /
    • 1994
  • 최근 항공우주 및 생산자동화 분야의 급격한 발달에 따라 정밀도와 효율성을 향상시키기 위해 저중량, 고강도 구조물이 요구된다. 그러나 경량화 추세로 인해 수반되는 구조물의 유연성 증가로 외력에 대한 구조응답의 진폭이 커지고 구조물의 피로 수명이 단축되어 매우 위험한 상황에 이를 수 있다. 이런 바람직하지 않은 진동현상을 제어하기 위해 여러 제어이론을 응용한 진동억제시스템의 연구가 활발하며, 신소재인 압전재료의 개발로 새로운 방향이 제시되고 있다. 압전재료는 유연한 구조물에 부착되어 압전재료의 수축, 팽창 운동에 의해 발생된 에너지를 부착된 구조물에서의 제어력으로 사용되어, 진동 혹은 자세 및 형상 제어에 활용되고 있다. 압전재료에 대한 연구로는 Crawley, de Luis3가 보의 표면 혹은 내부에 압전세라믹을 부착하여 액튜에이터로 사용하는 경우 집중모멘트를 가하는 역할을 함을 밝혔고, Hanagud, obal은 압전재료를 센서와 액튜에이터로 사용해 복합재료 보에 대한 최적 진동제어 알고리즘을 개발, 그 성능에 대한 효과를 조사하였고 임의의 위치에 부착된 센서 및 액튜에이터를 고려한 복합재료 보의 운동방정식을 유한요소법을 이용 유도하였으며 변위율 피드백(rate feedback)과 모달피드백(modal feedback) 제어기를 적용하여 진동제어 효과를 고찰하였다. 그리고 Tomas, James, Hubbard는 압전필름을 액튜에이터로 사용해 복합재료 보에 Liapunov 제어기와 변위율 피드백 제어기를 사용하여 능동감쇠기를 설계하였고, Lee, Chaing, Sullivan은 압전필름을 센서와 액튜에이터로 사용해 평판에 변위율 피드백 제어기를 적용한 능동감쇠기를 설계하고 실험적으로 수행하였다. Base가 백색잡음가진을 지속적으로 받을 때 보끝의 움직임이 최소가 되도록 제어하고자 연구를 수행 중인 바 그 결과로소 본 논문에서는 적용시켰고 F-P-K 방정식을 이용해 확률영역으로 변환하여 LQR 제어기와 pole allocation 제어기를 시스템에 적용시켜 우수한 특성을 갖음을 제어 시뮬레이션의 결과를 통해 입증하였다.

  • PDF

Developing Tuned Mass Damper of Adjustable Damping Type to Control the Vibrations of Medical Robots (의료용 로봇의 미진동제어를 위한 가변감쇠형 동조질량감쇠기 기술 개발)

  • Cha, WoonYong;Chun, ChongKeun;Park, SangGon;Han, HyunHee
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.9
    • /
    • pp.706-715
    • /
    • 2014
  • Recently, the medical community has been enthusiastically welcoming robots that are able to provide high-quality medical services across the board, including assisting the surgeons during surgeries. In response, many higher education institutions and research facilities started to conduct various experiments and studies about these robots. During such research, it was discovered that the arm of one particular robot type that is being developed to assist surgeries are prone to vibrate even from the weakest impact, in addition to other residual vibration problems. We attempted to reduce such dynamic response by using a MF-TMD that is produced by adding magnetic fluid to ECD. We verified the MF-TMD's performance by testing it within various frequency bands and attenuations. We then designed a cantilever that was structurally similar to the robot's arm. We attached the MF-TMD to this cantilever and conducted a pilot experiment, which validated our hypothesis that MF-TMD will reduce the robot arm's vibrations through its optimal damping ratio. Henceforth, we attached the MF-TMD to the robot arm in question and conducted a performance experiment in which we tuned the MF-TMD's frequency and damping factor to its optimal level and measured the vibrations of the arm. The experiment demonstrated that the vibrations that occurred whenever the arms rotated were significantly reduced.

A Case Study of Tunnel Electronic Blasting to Control Vibration in the Proximity of the Safety Facilities (근접 보안물건의 진동제어를 위한 터널 전자발파 시공사례)

  • Seo, Yun-Sik;Woo, Sang-Don;Kwon, Yeong-Bok;Kim, Jong-Su;Choi, Hyeong-Bin;Kim, Seon-Hong;Kim, Gab-Soo;Kim, Jae-Hoon;Kim, Hee-Do;Lee, Jun-Won
    • Explosives and Blasting
    • /
    • v.30 no.1
    • /
    • pp.37-51
    • /
    • 2012
  • In this case of "Seongnam~Yeoju double-lanes railroad construction", there were safety facilities which were concerned about damages from vibration and noise. In the project design stage, the rock-splitter method was designed to prevent them. The electronic blasting was considered to improve construction speed and economic value as an alternative tunnelling method, complying with the site's vibration criteria(cowhouse : 0.09cm/sec, residence : 0.2cm/sec). In the environment evaluation report of the eDev, tunnel electronic blasting systems, the blasting pollutions can be managed by the electronic blasting method. The results were successfully conducted with high speed construction without any damages to adjacent facilities.

Decision Making Model for Powertrain Mount-Stop&Go Performance in a compact mobile (소형 승용차의 파워트레인 마운트 Stop&Go 성능 적용을 위한 의사결정모델)

  • Yu, Jung-Woo;Um, In-Sup;Lee, Hong-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.3
    • /
    • pp.967-976
    • /
    • 2012
  • This study presents a model to minimize vibration and noise of powertrain mount on a compact car which has the application of Stop & Go performance, in order to reduce CO2 and achieve better fuel-efficiency in accordance with the environmental regulations in automotive industries. In the first step, we analyze the powertrain mount system of the automobile "A" and present variables about rubber stiffness applied on powertrain mount using the Taguchi method. In the next step, we verify the optimization of vibration and noise which meet Stop & Go performance using the AHP(Analytic Hierarchy Process) method on the proto products for each variable. Using this validation system on the initial stage of the powertrain mount design, it is expected that we can grasp vibration and noise problems caused by engine movements and control them effectively without engineering know-how about powertrain mount rubber stiffness.

Analytical Evaluation of Airborne Noise for the Building Structure' on Railway Transportation Systems (철도부지 상부 입체 건축물의 공기전달음 소음 예측)

  • Yeon, Jun-Oh;Kim, Kyoung-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.12
    • /
    • pp.1096-1102
    • /
    • 2013
  • The useful practical land shall be reserved when an artificial land covers the railway and road. However, the problem is that since the artificial land places directly on the top of noise sources likely on the railway and road there will arise the weak points, noise and vibration. On this study based on creating the artificial land on the top of a railway vehicle base and placing a tenement on that land, it was comprehended the noise influence from the railway car through the simulation. In order to secure the input value for the simulation, at first measured the noise condition of the railway station building and the railway vehicle base. The output value for the railway station building (place A) was around (53.6~57.6) dB(A), the equivalent continuous sound level for an hour, and for the railway station building (place B) it was around (63.7~68.9) dB. The maximum outdoor noise of the tenement on the artificial land was measured as 64.1 dB(A) under the fixed condition on the simulation modeling. The built purpose of placing the artificial land to prevent the noise influence from the railway met the expectation to be less influenced on the tenement. Rather, because of placing the artificial land the noise level on the lower space could be increased so there requires having a noise control.

Buckling and free vibration analysis of tapered FG- CNTRC micro Reddy beam under longitudinal magnetic field using FEM

  • Mohammadimehr, M.;Alimirzaei, S.
    • Smart Structures and Systems
    • /
    • v.19 no.3
    • /
    • pp.309-322
    • /
    • 2017
  • In this paper, the buckling, and free vibration analysis of tapered functionally graded carbon nanotube reinforced composite (FG-CNTRC) micro Reddy beam under longitudinal magnetic field using finite element method (FEM) is investigated. It is noted that the material properties of matrix is considered as Poly methyl methacrylate (PMMA). Using Hamilton's principle, the governing equations of motion are derived by applying a modified strain gradient theory and the rule of mixture approach for micro-composite beam. Micro-composite beam are subjected to longitudinal magnetic field. Then, using the FEM, the critical buckling load, and natural frequency of micro-composite Reddy beam is solved. Also, the influences of various parameters including ${\alpha}$ and ${\beta}$ (the constant coefficients to control the thickness), three material length scale parameters, aspect ratio, different boundary conditions, and various distributions of CNT such as uniform distribution (UD), unsymmetrical functionally graded distribution of CNT (USFG) and symmetrically linear distribution of CNT (SFG) on the critical buckling load and non-dimensional natural frequency are obtained. It can be seen that the non-dimensional natural frequency and critical buckling load decreases with increasing of ${\beta}$ for UD, USFG and SFG micro-composite beam and vice versa for ${\alpha}$. Also, it is shown that at the specified value of ${\alpha}$ and ${\beta}$, the dimensionless natural frequency and critical buckling load for SGT beam is more than for the other state. Moreover, it can be observed from the results that employing magnetic field in longitudinal direction of the micro-composite beam increases the natural frequency and critical buckling load. On the other hands, by increasing the imposed magnetic field significantly increases the stability of the system that can behave as an actuator.