Design of the Controller with Sliding Mode for Robot Arm (슬라이딩모드를 갖는 로봇 팔의 제어기 설계)

  • 서원창;임규만;정영창
    • Proceedings of the IEEK Conference
    • /
    • 1999.11a
    • /
    • pp.703-706
    • /
    • 1999
  • In this paper, robust vibration control of a one-link flexible robot arm based on variable structure system is discussed. We derive dynamic equations of it using a Lagragian assumed modes method based on Bernoulli-Euler beam theory. The optimal sliding surface is designed and the problem of chattering is also solved by the adoptation of a continuous control law within a small neighborhood of the switching hyperplane.

  • PDF

Position control of single-link manipulator using neural network (신경 회로망을 이용한 단일 링크의 유연한 매니퓰레이터의 위치제어)

  • 이효종;최영길;전홍태;장태규
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10a
    • /
    • pp.18-23
    • /
    • 1990
  • In this paper, the dynamic modeling and a tip-position controller of a single-link flexible manipulator are developed. To design the controller of a flexible manipulator, at first, it is required to obtain the accurate dynamic model of manipulator describing both rigid motion and flexible vibration. For this purpose, FEM(Finite Element Method) and Lagrange approach are utilized to obtain the dynamic model. After obtaining the dynamic model of a single-link manipulator, a controller which computes the input torque to perform the desired trajectory is developed using neural network.

  • PDF

Automatic measurement of blade width using image processing techniques (영상처리에 의한 연삭면 너비 계측)

  • 김선일;박종구;박찬웅
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10a
    • /
    • pp.799-804
    • /
    • 1990
  • In the blade grinding process, Blade image is captured. It is captured in the environment with vibration, using monochrome CCD camera with high speed electronic shutter. The image is preprocessed using LoG filter and zero crossing. We used Hough transformation to detect straight lines from the preprocessed image. From the equations of detected lines, we calculated width between lines caused by grinders. This paper proposes automatic measurement of blade width to automate the process control of blade grinding line.

  • PDF

Displacement Sensorless Active Magnetic Bearing Control by Current Measurement (전류신호를 이용한 능동 자기 베어링계의 제어)

  • 권계시;정호섭;이종원
    • Journal of KSNVE
    • /
    • v.5 no.1
    • /
    • pp.49-57
    • /
    • 1995
  • An electronic circuit device is developed such that the displacement between an electromagnet and a moving target can be estimated from the coil current measurement, and then applied to an active magnetic bearing system. In order to levitate the shaft without using displacement sensor the stable control gains are obtained from the linearized model which includes the gap estimation circuit. Experimental results show that the shaft, by the estimated gap feedback, can be levitated within $\pm$6 ${\mu}m$ positioning error.

  • PDF

A Study on Control Parameter Tuning for Actuator in Control Loading System (조종 반력 시스템에서의 액츄에이터 제어 파라미터 조정에 관한 연구)

  • Yoon, Tae-Sung;Park, Seung-Gyu;Park, Joon-Ho;Kim, Tae-Kue
    • Proceedings of the KIEE Conference
    • /
    • 2006.04a
    • /
    • pp.249-251
    • /
    • 2006
  • In this study, a systematic and effective tuning method of the actuator control parameters of the control loading system for aircraft based on control theory is presented. Firstly, to raise the time response of the system, the proportional gain and the integral gain of the velocity control loop is maximized within the range where vibration and noise does not occur. And then the position control loop is composed by getting the transfer function of the control loading system including the velocity control loop. With the root locus of the composed position control loop, the proportional gain of the position control loop that keeps stable transient state and leads good time response of the system is predicted, and the simulations are performed by using the predicted gain. Lastly, the actuator control parameters of actual control loading system are set to the previously obtained gain values. And the experiments to actuate the control loading system are executed. It shows that the tuning method of the actuator control parameter proposed in this study is applied to actual control loading system very well by comparing the results of the experiments with those of the simulations.

  • PDF

The Control of Vertical Vibration of Building Slabs using Tuned Mass Dampers (동조질량 감쇠기에 의한 건물 바닥판의 연직진동제어)

  • 이동근;김진구;안상경
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.2 no.4
    • /
    • pp.103-114
    • /
    • 1998
  • The floors of building structures equipped with vibrating machines can be susceptible to large vibration as a result of resonance or beating. Such a vibration can be reduced efficiently by using tuned mass dampers. However, the effectiveness of the damper depends greatly on the location and the natural frequency of the damper. To determine the optimum damper location is especially important since the dynamic behavior of a building structure varies with the location of the input loading. To this end, it is intended to decide the location and natural frequency of tuned mass dampers for reducing vibration of both loaded floors and floors located nearby the loaded floors considering the location and frequency components of the loading. The Vector composition method and the super elements are used th obtain the responses in steady states, and the optimum damper location and natural frequencies were found with the given damper mass.

  • PDF

Comparison of static culture, micro-vibration culture, and micro-vibration culture with co-culture in poor ovarian responders

  • Hur, Yong Soo;Ryu, Eun Kyung;Yoon, San Hyun;Lim, Kyung Sil;Lee, Won Don;Lim, Jin Ho
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.43 no.3
    • /
    • pp.146-151
    • /
    • 2016
  • Objective: This study was conducted to compare the effects of static culture, dynamic culture, and the combination of dynamic culture with specialized surfaces involving co-culture on human embryonic development. Embryos cultured using conventional static culture (SC) techniques served as a control group. We compared dynamic culture using micro-vibration culture (MVC) and micro-vibration with co-culture (MCoC), in which autologous cumulus cells were used as a specialized surface. Methods: We conducted a chart review of patients who were treated between January 2011 and November 2014 in order to compare embryonic development rates and pregnancy rates among the groups. Zygotes were cultured in micro-droplets, and embryos were subsequently selected for transfer. Some surplus embryos were cryopreserved, and the others were cultured for blastocyst development. A micro-vibrator was set at the frequency of 42 Hz for duration of 5 seconds per 60 minutes to facilitate embryo development. Results: No significant differences among the groups were present in patient's characteristics. However, the clinical pregnancy rates were significantly higher in the MVC group and the MCoC group than in the SC group. No significant differences were found in the blastocyst development rate between the SC group and the MVC group, but the blastocyst development rate in the MCoC group was significantly higher than in the SC and MVC groups. Conclusion: The clinical pregnancy rate was significantly increased by the application of micro-vibration to the embryonic cultures of poor responders. The blastocyst development rate was significantly increased by the application of MCoC to surplus embryos.

Damping and vibration response of viscoelastic smart sandwich plate reinforced with non-uniform Graphene platelet with magnetorheological fluid core

  • Eyvazian, Arameh;Hamouda, Abdel Magid;Tarlochan, Faris;Mohsenizadeh, Saeid;Dastjerdi, Ali Ahmadi
    • Steel and Composite Structures
    • /
    • v.33 no.6
    • /
    • pp.891-906
    • /
    • 2019
  • This study considers the instability behavior of sandwich plates considering magnetorheological (MR) fluid core and piezoelectric reinforced facesheets. As facesheets at the top and bottom of structure have piezoelectric properties they are subjected to 3D electric field therefore they can be used as actuator and sensor, respectively and in order to control the vibration responses and loss factor of the structure a proportional-derivative (PD) controller is applied. Furthermore, Halpin-Tsai model is used to determine the material properties of facesheets which are reinforced by graphene platelets (GPLs). Moreover, because the core has magnetic property, it is exposed to magnetic field. In addition, Kelvin-Voigt theory is applied to calculate the structural damping of the piezoelectric layers. In order to consider environmental forces applied to structure, the visco-Pasternak model is assumed. In order to consider the mechanical behavior of structure, sinusoidal shear deformation theory (SSDT) is assumed and Hamilton's principle according to piezoelasticity theory is employed to calculate motion equations and these equations are solved based on differential cubature method (DCM) to obtain the vibration and modal loss factor of the structure subsequently. The effect of different factors such as GPLs distribution, dimensions of structure, electro-magnetic field, damping of structure, viscoelastic environment and boundary conditions of the structure on the vibration and loss factor of the system are considered. In order to indicate the accuracy of the obtained results, the results are validated with other published work. It is concluded from results that exposing magnetic field to the MR fluid core has positive effect on the behavior of the system.

An Experimental Study on the Pump Operating Characteristics with Low Flow Operation (펌프의 저 유량 운전특성에 관한 실험적 연구)

  • 오광석;신필권;박종호;심우건;조두연
    • Journal of KSNVE
    • /
    • v.9 no.1
    • /
    • pp.85-96
    • /
    • 1999
  • For ASME Code pumps in nuclear power plants, inservice test is required to assess the operational readiness in accordance with ASME code and related regulations. The objective of this study therefore, is to develop the technical background of the degradation of pump performances and conditions due to low flow rate operation. In addition. the detection techniques of pump operating conditions are to be developed to enhance the safety and economy of nuclear power plants. A test loop consisted of pump, motor. water tank, flow rate measurements and piping system with flow control devices was established for this study. Two typical pumps, 1-stage volute pump and 3-stage turbine pump, were selected and the test was performed upon two major point of views ; i.e., pump discharge pressure pulsations analysis and pump vibration spectrum analysis. From the test results, it is concluded that (1) the pump vibration affected by the natural frequency of operating pump is significant in the low frequency zone (around 1 Hz) : the vibration amplitude. especially. is an important factor during low flow rate operation. and shall be monitored to ensure that it is within the limit of ASME OM code Part 6, (2) the vibration frequency and pump discharge pressure are affected by vane pass frequency and running speed, (3) the wave phenomena due to the compressiblity of water is anticipated during low flow rate operation. and the pump system shall be designed to prevent it and. finally, (4) the technical background of the degradation of pump performances and conditions due to low flow rate operation is provided.

  • PDF

The Design of the Motor Bracket for Reduction of Structure- Borne Noise in Package Air-Conditioner (에어컨의 구조 소음 저감을 위한 실내기 모터 브라켓의 설계)

  • Sim Hyoun-Jin;Lee Sung-Jin;Kang Tae-Ho;Lee Jung-Yoon;Oh Jae-Eung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.2 s.245
    • /
    • pp.202-209
    • /
    • 2006
  • As the economic power is improved and the customer's demand is hard to please, the noise and vibration is the most important yardstick that can determine the quality of the product. Especially, as the airconditioner's demand increase suddenly, the product of quality and the noise is becoming a decisive factor of determining whether purchase the product or not. Therefore, every manufactory is investing a lot of money and research to cut down the unpleasantness induced from noise and vibration. And they are emphasizing their product's difference by advertising a silence very actively. With these reason, the demand of a silent indoor air-conditioner is the essential research filed when the product is develop(:d. In this study, the noise and vibration is visualized in the space and frequency domain by using experimental methods such as operational deflection shape (ODS), modal testing and sound intensity. Also the location of noise source and its characteristic is analyzed in an acoustical point of view to reduce the structure borne noise that come from the fan motor, and the pertinent control method is suggested. Furthermore, the most suitable shape of the motor bracket is suggested by applying FEM and DOE (Design of experiments) in the noise and vibration point a view.