• Title/Summary/Keyword: control vibration

Search Result 4,113, Processing Time 0.029 seconds

Roll Motion Control of a Mover in Bearingless Linear Motor by Using One-sided Active Magnetic Bearings (베어링리스 리니어 모터에서의 편측식 전자기 베어링을 이용한 이동자의 롤 운동 제어)

  • Kim, Woo-Yeon;Lee, Jong-Min;Kim, Seung-Jong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.11
    • /
    • pp.1184-1191
    • /
    • 2009
  • A bearingless linear motor(BLLM) which consists of two stators and a common mover is able to levitate and move its mover without any linear bearing or even additive windings. In the previous study, BLLM was actively controlled on the translation and pitch motion, while the roll motion is passively stable. In order to control the roll motion, this paper suggests adding active magnetic bearings(AMBs) at bottom of the mover in BLLM. The AMBs control the roll motion and also partially supports the weight of the mover. In this paper, magnetic forces generated by the AMBs are estimated by using an FEM model. Based on the analysis results, the bias current of the AMBs is determined and a PD controller is designed. Through an experimental levitation test, it was verified that roll motion is well controlled by AMB during levitation.

LMI Based $H_{\infty}$ Active Vibration Control of a Structure with Output Feedback : Experiment Results (LMI에 기초한 구조물의 $H_{\infty}$ 능동진동제어 : 실험적 고찰)

  • Byun, J.H.;Kim, Y.B.;Jeong, H.J.
    • Journal of Power System Engineering
    • /
    • v.3 no.3
    • /
    • pp.83-90
    • /
    • 1999
  • 제어이론분야에서의 발전은 그러한 이론을 다방면으로 응요할 수 있는 분야를 더더욱 폭넓게 제공해 주고 있다. 자동화와 관련된 분야뿐만 아니라, 건축 및 토목분야에서도 고도의 제어어이론을 응용한 예를 쉽게 접할 수 있게 되었으며, 지진동에 의한 구조물의 진동을 억제하려는 방책이 그 ??ㅣ다. 이에 관한 많은 연구에서도 알 수 있듯이, 일반적으로 구조물의 수학적 모델에만 의존하여, 즉 구조물의 설계파라미터는 이미 설계되어져 있다는 가정하에 제어계를 설계하고 있다. 그러나 이러한 설계법에 있어서는 설계자로 하여금 구조물의 설계파라미터를 조정할 수 있는 자유도는 전혀 주어지지 않게 되며 단지 제어계의 파라미터를 조정하는 자유도만 허용된다. 이러한 문제점을 극복하기 위해 구조계 및 제어기의 설계파라미터를 동시에 조절할 수 있는 자유도가 허용되는 '구조계/제어계의 동시 최적화' 기법이 있다. 따라서 본 논문에서는 교량의 주탑 및 해양구조물 등의 진동제어 문제에 이러한 설계기법을 이용하여 주어진 설계사양을 만족하도록 구조계 및 제어계의 파라미터를 최적화 한다. 특히 본 논문에서는 제어계 설계 문제에 있어서의 일반적인 경우를 고려하여 상태의 일부가 관측된다고 가정하고 출력피드백의 경우에 대해 고찰하고 있다. 이때의 설계사양은 선형행렬부등식(LMI)으로 주어지며, 실험을 통하여 본 논문에서 소개하는 설계기법의 유효성을 검증한다.

  • PDF

Cabin Noise Reduction Using Unit Cabin Mock-up of High Value-added Vessel (고부가가치선의 Unit Cabin Mock-up을 이용한 캐빈소음 저감 연구)

  • Song, Keun-Bok;Joo, Won-Ho
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.12
    • /
    • pp.1210-1215
    • /
    • 2010
  • Unit cabin means room, which is installed in the high value-added vessel such as drill ship, offshore platform and FPSO, after pre-assembled. In order to develop the noise control design for a unit cabin, a variety of acoustic tests such as sound absorption, transmission and radiation measurements were carried out by using the deckhouse mock-up. From the tests, it was found out that the sound transmission loss between cabin and corridor was 13 dB below than FPSO standard and the combined noise level of the unit cabin was dominated by the radiated noise from wall panel in low frequency range. Based on the test results, design guidelines for the noise control of the unit cabin were fully established, such as the improvement of sound transmission loss between the cabin and corridor, and radiated cabin noise reduction.

An Experimental Study on the Sound Insulation Performance of Korean Traditional Houses (전통주택의 차음성능 평가에 관한 실험적 연구)

  • Kim, Sun-Woo;Lee, Tai-Gang;Kim, Hyung-Ryul;Kim, Hang;Choi, Eun-Suk
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.2 s.107
    • /
    • pp.141-148
    • /
    • 2006
  • Korean traditional houses have been evolved and developed in many years, adopting the natural environment to control exterior conditions. These control method are various Passive system of using natural materials, considering micro climate, building lay out, and these system are much natural and ecological to make the comfortable indoor climate than active systems of the present houses. This study aims to analyzed the acoustical characteristics of Korean traditional houses varied with lay out and floor plan to reflect the way of control for environmental condition. The reverberation time and level difference between rooms of the main living room and other main floored room, master room and kitchen are measured in each houses. As a result, the reverberation time of Korean traditional rooms are below 0.6 second, and the sound insulation performance of Korean traditional door are mostly very low grade with D-15. The level difference between rooms are low grade not to meet minimum class except between main living room and master room away from main living building. These above results show that our traditional house are much more emphasized seeking visual privacy of rooms than aural privacy.

Ramp Load/Unload Velocity Control of VCM Using BEMF in HDD (램프 로드/언로드 하드디스크 드라이브의 역기전력을 이용한 VCM 속도제어)

  • Jeong, Jun;Kim, Tae-Soo;Kang, Tae-Sik;Jung, Kwang-Jo;Lee, Chul-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.1 s.106
    • /
    • pp.50-56
    • /
    • 2006
  • Since most of small form-factor drives have a load/unload mechanism and the flying height of the head is getting lower as the capacity of disk drives increases, the load/unload velocity becomes one of the important factors to ensure the reliability of the load/unload mechanism. To control the load/unload velocity accurately, velocity sensing is essential. In this paper, we introduce a very practical method that acquires the load/unload velocity from the back electromotive force (BEMF) of a voice coil motor (VCM) and propose a calibration method for measuring the BEMF from a given circuit. Moreover, the effect of calibration error and temperature variation on the measurement of BEMF is shown by simulation. Then, this present method is applied to the load/unload velocity controller and is verified from the experimental result.

Optimal placement and tuning of multiple tuned mass dampers for suppressing multi-mode structural response

  • Warnitchai, Pennung;Hoang, Nam
    • Smart Structures and Systems
    • /
    • v.2 no.1
    • /
    • pp.1-24
    • /
    • 2006
  • The optimal design of multiple tuned mass dampers (multiple TMD's) to suppress multi-mode structural response of beams and floor structures was investigated. A new method using a numerical optimizer, which can effectively handle a large number of design variables, was employed to search for both optimal placement and tuning of TMD's for these structures under wide-band loading. The first design problem considered was vibration control of a simple beam using 10 TMD's. The results confirmed that for structures with widelyspaced natural frequencies, multiple TMD's can be adequately designed by treating each structural vibration mode as an equivalent SDOF system. Next, the control of a beam structure with two closely-spaced natural frequencies was investigated. The results showed that the most effective multiple TMD's have their natural frequencies distributed over a range covering the two controlled structural frequencies and have low damping ratios. Moreover, a single TMD can also be made effective in controlling two modes with closely spaced frequencies by a newly identified control mechanism, but the effectiveness can be greatly impaired when the loading position changes. Finally, a realistic problem of a large floor structure with 5 closely spaced frequencies was presented. The acceleration responses at 5 positions on the floor excited by 3 wide-band forces were simultaneously suppressed using 10 TMD's. The obtained multiple TMD's were shown to be very effective and robust.

A Study on Development of an Active Hybrid Mount for Naval Ships (함정용 능동 하이브리드 마운트 개발에 대한 연구)

  • Moon, Seok-Jun;Ji, Yong-Jin;Yoon, Jeong-Sik;Choi, Seung-Bok;Lee, Hyun-Yup;Kim, Jae-Ho;Jung, Woo-Jin
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.45 no.3
    • /
    • pp.288-295
    • /
    • 2008
  • Passive-type control devices such as resilient mounts and wire rope isolators are generally used for protecting the shipboard equipment from shock loading and for suppressing the mechanical vibration of the equipment in naval ships. To improve the performance of the control device, a new hybrid mount is under development in this study. This mount consists of a passive-type rubber element and an active-type piezo-stack element. It can be expected that the mount has enhanced performance of about 20 dB or more with respect to transmissibility through a series of performance tests of prototype mount.

Performance Evaluation of Driver Supportive System with Haptic Cue Gear-shifting Function Considering Vehicle Model (차량모델을 고려한 햅틱 큐 기어변속보조 시스템의 성능평가)

  • Han, Young-Min;Sung, Rockhoon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.1
    • /
    • pp.54-61
    • /
    • 2014
  • This paper proposes a driver supportive device with haptic cue function which can transmit optimal gear shifting timing to a driver without requiring the driver's visual attention. Its performance is evaluated under vehicle model considering automotive engine, transmission and vehicle body. In order to achieve this goal, a torque feedback device is devised and manufactured by adopting the MR (magnetorheological) fluid and clutch mechanism. The manufactured MR clutch is then integrated with the accelerator pedal to construct the proposed haptic cue device. A virtual vehicle emulating a four-cylinder four-stroke engine, manual transmission system of a passenger vehicle and vehicle body is constructed and communicated with the manufactured haptic cue device. Control performances including torque tracking and fuel efficiency are experimentally evaluated via a simple feed-forward control algorithm.

Control Performance Evaluation of MR Brake Depending on Durability (MR 브레이크의 내구성에 따른 제어성능평가)

  • Kim, Wan Ho;Park, Jhin Ha;Yang, Soon Yong;Shin, Cheol Soo;Choi, Seung-Bok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.6_spc
    • /
    • pp.660-666
    • /
    • 2016
  • This paper presents performance comparison results of magneto-rheological (MR) brake in the sense of wear characteristics. To create wear circumstance, the brake is operated in 100 000 cycles by DC motor. To make wear test in same design parameters such as the radius of the housing, ferromagnetic disc and gap size, small sample of stainless are inserted in housing of MR brake. The performances of brake are compared between the initial stage (no wear) and 100 000 revolution cycles operated stage (wear). At each circumstance, torque of the brake is measured and compared by applying step current and sinusoidal control input. The controller used in this work is a simple, but effective PID controller. It is demonstrated that the wear behavior is more obvious as the operating cycle is increased in the torque control process.

Seismic Qualification of the Main Control Board for Nuclear Power Plant (원자력발전소용 주 제어반의 내진 검증)

  • 변훈석;이준근
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.11
    • /
    • pp.856-863
    • /
    • 2002
  • Seismic qualification of the main control board(MCB) for the nuclear power plant Ulchin 5 and 6 has been performed with the guideline of ASME Section III and IEEE 344 code. As the size and weight of the MCB are too large and heavy to excite using the excitation table, finite element analysis is used in order to investigate the dynamic behaviors and structural integrity of the MCB. As the fundamental frequencies of the equipment are found to be less than 33 Hz, which is the upper frequency limit for the dynamic analysis, response spectrum analysis using ANSYS is performed in order to combine the modal stresses within the frequency limit. In order to confirm the electrical stability of the major components of the MCB. modal analysis theory has been adopted to derive the required response spectra at the component locations. As the all combined stresses obtained from the above procedures are less than the allowable stresses and no mechanical or electrical failures are found from the seismic testing, the authors can confirm the safety of the nuclear equipment MCB under the given seismic loading conditions.