• Title/Summary/Keyword: control surface

Search Result 7,687, Processing Time 0.046 seconds

THE EFFECTS OF DRYING AGENTS AND BONDING AGENTS ON THE SHEAR BOND STRENGTH OF SEALANTS TO ENAMEL (치면건조제와 접착제의 사용에 따른 치면열구전색재의 전단결합강도에 관한 연구)

  • Lim, Hyun-Hwa;Jang, Ki-Taek;Kim, Chong-Chul;Hahn, Se-Hyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.2
    • /
    • pp.196-203
    • /
    • 2003
  • The application of sealants is a highly technique-sensitive procedure, requiring an extremely dry field prior to placement. Moisture contamination of the etched enamel surface before sealant placement is cited as the main reason for sealant failure. The purpose of this study was to evaluate the effects of different methods of sealant application on the shear bond strength of sealants to enamel. In groups 1, 2, 3, 4 Teethmate(unfilled sealant) was used, while Ultraseal XTplus(filled sealant) was used in groups 5, 6, 7, 8. Groups 1 and 5(control) were acid etched for 15 seconds using 35% phosphoric acid, washed and then dried. In groups 2, 6 drying agents were applied, and in groups 3, 7 bonding agents were applied and light cured. In groups 4 and 8 both drying agent and bonding agent were applied. Then sealant was cured to the specimen using molds 3mm in diameter and 2mm in height. Thermocycling was performed and shear bond strength was finally measured. The following results were obtained : 1. Groups using filled sealant(groups 5, 6, 7, 8) showed higher shear bond strengths compared to groups using unfilled sealant(groups 1, 2, 3, 4). 2. Among groups using unfilled sealant(groups 1, 2, 3, 4), groups 2, 3, 4 showed significantly higher shear bond strength compared to group 1(p<0.05). There were no significant differences among groups 2, 3 and 4. 3. There were no significant differences(p>0.05) among groups using filled sealant(groups 5, 6, 7, 8). 4. When modes of fracture were examined, cohesive failure was observed in groups 2, 3 and 4.

  • PDF

REMINERALIZATION EFFECT OF COMMERCIALLY AVAILABLE ANTICARIOGENIC PRODUCTS ON ARTIFICIAL CARIES LESION USING QLF (QLF를 이용한 항우식 제품의 인공우식 재광화 효과에 대한 연구)

  • Song, Ju-Hyun;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taeg;Kim, Chong-Chul;Hahn, Se-Hyun;Lee, Sang-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.2
    • /
    • pp.287-296
    • /
    • 2008
  • The purpose of this in vitro study was to compare the remineralization effect of commercially available anticariogenic products, exactly low level fluoride mouthrinse(500 ppm NaF), tooth cream with Casein phosphopeptide-amorphous calcium phosphate(CPP-ACP) and fluoride mouthrinse plus tooth cream on artificial caries lesion. Artificial caries lesion was induced at the buccal surface of permanent third molar and the specimens were then divided(16 specimens/group) into four group. Twice a day during 28 days specimens of each group were treated with a commercially anticariogenic product as follows and applied to the pH cycling system. Group 1: control group (No treatment) Group 2: Tooth $Mousse^{(R)}$ (GC Co. Japan) Group 3: $chikachika^{(R)}$ (Samil Co. Korea) Group 4: $chikachika^{(R)}$+Tooth Mousse$^{(R)}$ The long-term change of mineral loss(${\Delta}Q$) was evaluated by quantitative light-induced fluorescence (QLF) and the following results were obtained: 1. ${\Delta}Q$ of Group 1 was not noticed statistically significant during 28 days comparing that prior to treatment. There was a statistically significant increase in ${\Delta}Q$ of Group 2 and 3 since 14 days. So was in ${\Delta}Q$ of Group 4 since 7 days. 2. ${\Delta}Q$ was increased as follows: Group 1< Group 2, 3< Group 4. 3. Comparing with Group 1, Group 2 was a statistically significant increase since 7 days and Group 3 and 4 were since 3 days. Comparing Group 2 with 3, there was not noticed statistically significant during whole duration. Group 4 was significantly higher than Group 2 and 3 after 28 days. 4. All groups demonstrated a decrease in the rate of remineralization as time goes on.

  • PDF

Effect of Pumpkin, Corn Silk, Adzuki Bean, and Their Mixture on Weight Control and Antioxidant Activities in High Fat Diet-Induced Obesity Rats (호박즙, 옥수수수염차, 팥차 및 혼합물이 식이유도 비만동물모델에서 체중과 항산화 활성에 미치는 영향)

  • Park, Jae-Hee;Lee, Eunji;Park, Eunju
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.45 no.9
    • /
    • pp.1239-1248
    • /
    • 2016
  • Pumpkin juice (PJ), corn silk tea (CT), and adzuki bean tea (AT) have long been used for treatment of obesity in Korea. This study investigated the efficacy of PJ, CT, AT, and their mixture (PCA) on alteration of body weight and antioxidant metabolism in high-fat diet (HFD)-induced obese rats. After being fed HFD for 4 weeks, SD rats were divided into six groups fed a normal diet (ND), HFD, HFD+PJ [250 mg/kg body weight (BW)], HFD+CT (250 mg/kg BW), HFD+AT (250 mg/kg BW), and HFD+PCA (PJ : CT : AT=1:1:1, 250 mg/kg BW) for another 9 weeks. HFD consumption resulted in total lipid, triglyceride, and total cholesterol accumulation in adipose tissue, which was reduced by administration of PJ, CT, AT, or PCA. The plasma oxygen radical absorbance capacity value and hepatic glutathione peroxidase activity significantly increased compared to the HFD group. The liver thiobarbituric acid reactive substances was significantly lower in the PCA group than the HFD group. HFD-induced DNA damage in hepatocytes, as measured by comet assay, decreased in the PJ, AT, and PCA-supplemented groups. The PCA group exerted a superior antigenotoxic effect compared to other treatments. PCA recovered the concentration of plasma adiponectin, which was reduced by HFD. Adipocyte surface area (%) was significantly higher in the HFD group than the ND group, significantly lower in the PJ and PCA groups than the HFD group, and not significantly different compared with the ND group. Based on the results, supplementation of PJ, CT, AT, and PCA exhibited lipid-lowering effects in adipocytes of HFD-induced obese rats. Furthermore, the PCA group exhibited superior antioxidant activity in all treated groups. This study suggests that a mixed beverage consisting of PJ, CT, and AT may be a significant source of natural antioxidants, which might be helpful in preventing obesity and progress of various oxidative stresses induced by HFD.

The Suppressive Effects of Integrin Antibodies on the Infection of Hantaan Virus in Fibroblasts (한탄바이러스의 섬유아세포 감염에 대한 Integrin 항체의 억제 효과)

  • Park, Ho-Sun;Kim, Ki-Duk;Kim, Sung-Kwang
    • Journal of Yeungnam Medical Science
    • /
    • v.15 no.1
    • /
    • pp.55-66
    • /
    • 1998
  • Pathophysiological mechanism of hemorrhagic fever with renal syndrome (HFRS) is not fully understood. Major clinical findings of HFRS patients are widespread hemorrhage, acute renal failure and shock. Basic lesion is vascular injury with microvascular hemorrhage and relatively little inflammation. According to autopsy findings, renal medulla shows focal hemorrhage, tubular necrosis and interstitial mononuclear infiltrates. The predominant cell type in the renal and pulmonary interstitium is a fibroblast and it participates in the healing process at the injury site by secreting a large amount of extracellular matrix proteins. Cultured human lung fibroblasts and Mongolian gerbil fibroblasts were known to be good host cells for the hantaan virus. It is possible that not only the endothelial cell but also the fibroblast is a target of Hantaan virus and the fibroblast might be involved in the pathogenesis and the healing process in HFRS. Integrins are adhesion molecules, and act as receptors for many extracellular matrix proteins. Recently, there are many reports that cell surface integrins influence on some viral infections or reversely viruses influence on the expression of integrins. The ${\alpha}_5{\beta}_1$ integrin is a major receptor for the fibronectin which is an important extracellular matrix protein secreted by fibroblasts. In this study, the role of ${\alpha}_5{\beta}_1$ integrin in the infection of Hantaan virus was examined by using anti-${\alpha}_5{\beta}_1$, integrin, anti-${\alpha}_5$ integrin and anti-${\beta}_1$, integrin antibodies in chicken embryo fibroblasts (CEF) and Mongolian gerbil fibroblasts(MGF). The treatment of anti-${\alpha}_5{\beta}_1$, integrin antibody in CEF reduced the virion titers 26.8% and the amount of nucleocapsid N protein 32.6% when compared with control CEF. When MGF were treated with anti-${\alpha}_5$, anti-${\beta}_1$ and anti-${\alpha}_5{\beta}_1$ integrin antibodies, virion titers were reduced by 26.5%, 29.4% and 28.7% and the amount of nucleocapsid N protein were reduced by 65.2%, 59.7% and 72.6%. These results suggested that ${\alpha}_5{\beta}_1$ integrin might act as a receptor for the Hantaan virus or blocking of ${\alpha}_5{\beta}_1$ integrin influences on the viral replication in CEF and MGF. It is also possible that the blocking of only one subunit of integrin represents similar results in that of whole molecule.

  • PDF

The experimental study of early loading on the Miniplate in the beagle dog (성견의 하악골에 식립된 Miniplate에 가한 조기 부하의 영향에 관한 실험적 연구)

  • Chung, Yong-Koo;Lee, Young-Jun;Chung, Kyu-Rhim
    • The korean journal of orthodontics
    • /
    • v.33 no.4 s.99
    • /
    • pp.307-317
    • /
    • 2003
  • Conventional osseointegrated titanium implants have many limitations; large size, limited location for placement of the implant, severity of the surgery, discomfort of initial healing, difficulty of oral hygiene and uncontrollable force direction. Recently titanium miniscrew and miniplate have been used for an alternative to conventional dental implant. But in relation to miniplate, miniscrew has disadvantages in that more potential inflammation, light orthodontic force application and limited orthodontic application. This study was conducted to evaluate the effectiveness of miniplate by observing the reactions of peri-implant tissues to early orthodontic and orthopedic loading of titanium miniplate. In four adult beagle dogs 10 miniplates were inserted into the alveolar bone using 20 osseointegrated titanium screws. 4 miniplates were placed in two dogs(dogA, B) and 6 miniplates in two dogs(dogC, D). In dogA, B miniplates were loaded with 200gm of force immediately after placement for 15 weeks. In dogc, D, miniplates were loaded with 400gm of force immediately after placement for 8 weeks. Miniplates of dogA were removed, dogA was healed for 4 weeks, and the area which was removed of miniscrew was examined. Following an observation period, the miniplates including miniscrews and the surrounding bone of dogB and dogC, D were removed, respectively. Undecalcified section along the long axis of miniscrews were made and the degree of osseointegration was examined under the light microscope. The results were as follows. 1. In the histologic features there was direct contact between bone and miniscrew in all groups except one, dogC control group. The loaded miniscrew demonstrated only a slight increase of the osseous proximaty when compared with unloaded miniscrew 2. There was no significant difference of the osseointegration of Peri-miniscrew surface between dogB and dogC, D. But dogB showed slightly more increased bone apposition than dogC, D 3. The gingiva overlapping the miniplate and miniscrew showed no inflammatory sign in clinical and histological aspects. 4. The impaled hard and soft tissues at the area which was removed of miniscrews showed good healing without inflammatory reaction. 5. The mobility showed slight increase in un-loaded miniplate but that was insignificant. Based on the results of this study, miniplate(C-tube) can be used as a firm osseous orthodontic and orthopedic anchorage unit immediately after insertion.

PHOTOELASTIC ANALYSIS OF STRESS INDUCED BY FIXED PROSTHESES WITH RIGID OF NONRIGID CONNECTION BETWEEN NATURAL TOOTH AND OSSEOINTEGRATED IMPLANT (골육착성 보철 치료시 임플랜트와 자연 지대치와의 연결 방법에 따른 관탄성 응력 분석)

  • Kim, Young-Il;Chung, Chae-Heon;Cho, Kyu-Zong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.2
    • /
    • pp.271-300
    • /
    • 1993
  • The purpose of this study was to analyze the stress distribution at supporting bone according to the types of connection modality between implant and tooth in the superstrcture. This investigation evaluated the stress patterns in a photoelastic model produced by three different types of dental implants such as Branemark, Steri-Oss, IMZ and resin tooth using the techniques of quasi three dimensional photoelasticity. The teeth-supported bridge had a first molar pontic supported by second premolar and second molar as a control group. The implant and toothsupported bridge had a first molar pontic supported by second premolar and implant posterior retainer as an experimental group. Prostheses were mechanically connected to an adjacent second premolar by the rigid of nonrigid connection, Nonrigid connection used an attachment placed between the tooth-supported and fixture-supported component. The female(keyway) of attachment was placed on the distal end of the retainer supported by the tooth ; the male(Key) of attachment connected to the osseointegrated bridge was engaged into the keyway. All prostheses were casted in the same nonprecious alloy and were cemented and screwed on their respective abutments and implants. 16㎏ of vertical loads on central fossae of second premolar, first molar pontic, implant of second molar were applied respectively and 6.5㎏ of inclined load on middle buccal surface of first molar pontic was applied. The results were as follows : 1. Under the vertical load on the central fossa of first mloar pontic, the stress developed at the apex of tooth of implat was more uniformly distributed in the case of nonrigid connection than in the case of rigid connection. 2. Under the vertical load on the central fossa of first molar pontic, the stress developed around the cervical area of tooth of implant was larger in the case of rigid connection than in the case of nonrigid connection because the bending moment was more occured in the case of rigid connection than in the case of nonrigid connection. 3. Stress was more restricted to the loaded side of nonrigid connection than to that of rigid connection 4. Under the inclined load. The set screw loosening of implant was more easily occured in the case of nonrigid connection than in the case of rigid connection due to torque moment. 5. In the case of Branemark implant, the stress concentration in second premolar was larger and the stress developed around the cervical area of implant was lower than any other cases under the vertical load, because Branemark implant with the flexible gold screw was showed in incline toward second premolar by a bending moment. 6. The stress developed around the apex of tooth or implant was more uniformly distributed in the case of Steri-Oss implant with stiff screw than in the case of Branemark implant under the vertical load. But, the stress developed around the cervical area of the Steri-Oss implant was larger than that of any other implants because bending moment was occured by vertical migration of second premolar. 7. The stress distribution in the case of IMZ implant was similar to the case of natural teeth under small vertical load. But, the residual stress around the implant was showed to occurdue to deformation of IMC and sinking of screw under larger vertical load.

  • PDF

Analysis of radiation exposure in radiation worker in medical facility and student in clinical practice (의료기관 방사선작업종사자와 임상실습 학생의 피폭선량 분석)

  • Lee, Joo-Ah;Choi, Kwan-Woo;Min, Jung-Whan;Lim, Jong-Cheon;Son, Soon-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.8
    • /
    • pp.442-448
    • /
    • 2016
  • This study was conducted to determine the appropriateness of systemic radiation exposure control for students in clinical practice by comparing radiation exposure in radiography employees at different stations of a hospital with that of students conducting clinical practice using identical stations. Overall, 121 students who conducted clinical practice in the department of radiology area of C university hospital from July 2014 to August 2014 and 62 workers working in the same medical facility (47 in the department of radiology, 8 in the department of radiation oncology, 7 in the department of nuclear medicine) were investigated. The radiation exposure experienced by students was measured for 8 weeks, which is the duration of the clinical practice. Additionally, radiation exposure of workers were classified into 4 groups, department of radiology, department of radiation oncology, and department of nuclear medicine was compared. Dose was measured with OSLD and differences among groups were identified by ANOVA followed by Duncan's multiple range test. Among employees, those in the department of radiology, oncology and nuclear medicine were exposed depth doses of $0.127{\pm}0.331mSv$, $0.01{\pm}0.003mSv$, and $0.431{\pm}0.205mSv$, respectively, while students were exposed to $0.143{\pm}0.136mSv$. Additionally, workers in the department of radiology, oncology and nuclear medicine were exposed to surface doses of $0.131{\pm}0.331mSv$, $0.009{\pm}0.003mSv$, and $0.445{\pm}0.198mSv$, respectively, while students were exposed to $0.151{\pm}0.14mSv$, which was significantly different in both doses (p < 0.01). The average dose that students received is higher than that of the other groups (except for nuclear medicine workers), indicating that further improvements must be made in systemic controls for individual radiation exposure by including the students as subjects of management for protection from radiation.

Carbon nanotube field emission display

  • Chil, Won-Bong;Kim, Jong-Min
    • Electrical & Electronic Materials
    • /
    • v.12 no.7
    • /
    • pp.7-11
    • /
    • 1999
  • Fully sealed field emission display in size of 4.5 inch has been fabricated using single-wall carbon nanotubes-organic vehicle com-posite. The fabricated display were fully scalable at low temperature below 415$^{\circ}C$ and CNTs were vertically aligned using paste squeeze and surface rubbing techniques. The turn-on fields of 1V/${\mu}{\textrm}{m}$ and field emis-sion current of 1.5mA at 3V/${\mu}{\textrm}{m}$ (J=90${\mu}{\textrm}{m}$/$\textrm{cm}^2$)were observed. Brightness of 1800cd/$m^2$ at 3.7V/${\mu}{\textrm}{m}$ was observed on the entire area of 4.5-inch panel from the green phosphor-ITO glass. The fluctuation of the current was found to be about 7% over a 4.5-inch cath-ode area. This reliable result enables us to produce large area full-color flat panel dis-play in the near future. Carbon nanotubes (CNTs) have attracted much attention because of their unique elec-trical properties and their potential applica-tions [1, 2]. Large aspect ratio of CNTs together with high chemical stability. ther-mal conductivity, and high mechanical strength are advantageous for applications to the field emitter [3]. Several results have been reported on the field emissions from multi-walled nanotubes (MWNTs) and single-walled nanotubes (SWNTs) grown from arc discharge [4, 5]. De Heer et al. have reported the field emission from nan-otubes aligned by the suspension-filtering method. This approach is too difficult to be fully adopted in integration process. Recently, there have been efforts to make applications to field emission devices using nanotubes. Saito et al. demonstrated a car-bon nanotube-based lamp, which was oper-ated at high voltage (10KV) [8]. Aproto-type diode structure was tested by the size of 100mm $\times$ 10mm in vacuum chamber [9]. the difficulties arise from the arrangement of vertically aligned nanotubes after the growth. Recently vertically aligned carbon nanotubes have been synthesized using plasma-enhanced chemical vapor deposition(CVD) [6, 7]. Yet, control of a large area synthesis is still not easily accessible with such approaches. Here we report integra-tion processes of fully sealed 4.5-inch CNT-field emission displays (FEDs). Low turn-on voltage with high brightness, and stabili-ty clearly demonstrate the potential applica-bility of carbon nanotubes to full color dis-plays in near future. For flat panel display in a large area, car-bon nanotubes-based field emitters were fabricated by using nanotubes-organic vehi-cles. The purified SWNTs, which were syn-thesized by dc arc discharge, were dispersed in iso propyl alcohol, and then mixed with on organic binder. The paste of well-dis-persed carbon nanotubes was squeezed onto the metal-patterned sodalime glass throuhg the metal mesh of 20${\mu}{\textrm}{m}$ in size and subse-quently heat-treated in order to remove the organic binder. The insulating spacers in thickness of 200${\mu}{\textrm}{m}$ are inserted between the lower and upper glasses. The Y\ulcornerO\ulcornerS:Eu, ZnS:Cu, Al, and ZnS:Ag, Cl, phosphors are electrically deposited on the upper glass for red, green, and blue colors, respectively. The typical sizes of each phosphor are 2~3 micron. The assembled structure was sealed in an atmosphere of highly purified Ar gas by means of a glass frit. The display plate was evacuated down to the pressure level of 1$\times$10\ulcorner Torr. Three non-evaporable getters of Ti-Zr-V-Fe were activated during the final heat-exhausting procedure. Finally, the active area of 4.5-inch panel with fully sealed carbon nanotubes was pro-duced. Emission currents were character-ized by the DC-mode and pulse-modulating mode at the voltage up to 800 volts. The brightness of field emission was measured by the Luminance calorimeter (BM-7, Topcon).

  • PDF

THE EFFECT OF TEMPERATURE CHANGES ON THE PHYSICAL PROPERTIES OF POSTERIOR COMPOSITE RESINS (구치부용 복합 레진 가열시 물리적 성질의 변화에 관한 실험적 연구)

  • Park, Yeon-Hong;Min, Byung-Soon;Choi, Ho-Young;Park, Sung-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.14 no.1
    • /
    • pp.41-56
    • /
    • 1989
  • The purpose of this study was to examine the effect of temperature dependence of the behavior on the physical properties of posterior composite resins. Three light cure posterior composite resins (Heliomolar, Litefil-P, and P-50) and one chemical cure posterior composite resin (Bisfil-II) were used as experimental materials. Composite resin was placed in a cylindrical brass mold (2.5 mm high and 6.5 mm inside diameter) that was rested on a glass plate. Another flat glass was placed on top of the mold, and the plate was tightly clamped together. After the mold had been filled with the light cure composite material, the top surface was cured for 30 seconds with a light source. Chemical cure resin specimens were made in the same manner as above. Three hundreds and twenty composite resin specimens were constructed from the four composite materials. One hundred and sixty specimens of them were placed in a heater at $50^{\circ}C$, $75^{\circ}C$, $100^{\circ}C$, $125^{\circ}C$, $150^{\circ}C$, $175^{\circ}C$ and $200^{\circ}C$ for 5 minutes or 10 minutes respectively before compressive strengths were measured. Another one hundred and sixty specimens were tested for the diametral tensile strengths in the same way as above. They were randomly divided into eight groups according to the mode of heating methods as follows and stored in distilled water at $37^{\circ}C$ for 24 hours. Group $37^{\circ}C$ - specimens were stored at $37^{\circ}C$ in distilled water for 24 hours. Group $50^{\circ}C$ - specimens were heated at $50^{\circ}C$ after curing. Group $75^{\circ}C$ - specimens were heated at $75^{\circ}C$ after curing. Group $100^{\circ}C$ - specimens were heated at $100^{\circ}C$ after curing. Group $125^{\circ}C$ - specimens were heated at $125^{\circ}C$ after curing. Group $150^{\circ}C$ - specimens were heated at $150^{\circ}C$ after curing. Group $175^{\circ}C$ - specimens were heated at $175^{\circ}C$ after curing. Group $200^{\circ}C$ - specimens were heated at $200^{\circ}C$ after curing. Twenty specimens of each of four composite resins were respectively made by insertion of materials into same mold for examining the dimensional changes between before and after heating. The final eighty specimens were stored in distilled water at $37^{\circ}C$ for 24 hours before testing the dimensional changes. Compressive and diametral tensile strengths were measured crosshead speed 1mm/minute and 500Kg in full scale with a mechanical testing machine (DLC 500 Type, Shimadzu Co., Japan). Dimensional changes were determined by measuring the diametral changes of eighty specimens with micrometer (Mitutoyo Co., Japan). Results were as follows: 1. Diametral tensile strengths of specimens in all groups were increased with time heated compared with control group except for that in group $50^{\circ}C$ and the maximum diametral tensile strength was appeared in the specimen of Litefil-P heated for 10 minutes at $100^{\circ}C$. In heliomolar and P-50, it could be seen in the specimen heated for 10 minutes at $150^{\circ}C$, but in Bisfil-II, it could be found in the specimen heated for 5 minutes at $150^{\circ}C$. 2. Compressive strengths of specimens in all groups was tended to be also increased with time heated but that in group $50^{\circ}C$ and the maximum compressive strengths were showed in the same specimens conditioned as the diametral tensile strengths of four composite materials tested. 3. In Heliomolar, Litefil-P, and Bisfil-II, it was decreased in diameters of resin specimens between before heating and increased in diameters of resin specimens after storing in distilled water, but it was not in P-50. 4. There is little difference in diametral tensile strengths, compressive strengths, and dimensional changes followed by heating the resin specimens for 5 minutes and 10 minutes, but there is no statistical significances.

  • PDF

Fertilization Effects on Soil Properties, Understory Vegetation Structure and Growth of Pinus densiflora Seedlings Planted after Forest Fires (산불피해지에 식재 조림된 소나무임분의 시비처리에 따른 소나무 묘목의 생장, 토양특성 및 하층식생 구조의 변화)

  • Won, Hyung-kyu;Lee, Yoon Young;Jeong, Jin-Hyun;Koo, Kyo-Sang;Lee, Choong-Hwa;Lee, Seung-Woo;Jeong, Yong-Ho;Kim, Choonsig;Kim, Hyungho
    • Journal of Korean Society of Forest Science
    • /
    • v.95 no.3
    • /
    • pp.334-341
    • /
    • 2006
  • This study was to investigate the growth of planted red pine (Pinus densiflora S. et. Z.) seedling, soil properties and understory vegetation structure after fertilizer treatments [unfertilized plot (control), CF plot (Combination Fertilizer), UF plot (Urea Formaldehyde Fertilizer)] in a Pinus densiflora stand planted after the forest fires in Gosung, Gangwon province. The height growth rates of seedlings in four years were 264% in unfertilized, 404% in CF, and 388% in UF plots, respectively. The root collar diameters were increased 340% in unfertilized, 454% in CF, and 427% in UF plots, respectively. No significant changes occurred in soil total nitrogen and potassium ion ($K^+$) with the fertilization. However, available $P_2O_5$, content in the soil surface (0-15 cm) increased with the fertilizer application. Soil organic matter increased significantly with fertilizer treatments, while gradual decrease occurred in unfertilized plots. Sodium ion ($Na^-$) decreased in all sites. Soil pH, CEC, calcium ion ($Ca^{2+}$) and magnesium ion ($Mg^{2+}$) contents were not significantly different among treatments. Although Shannon's species diversity index and species richness in understory vegetation did not change with fertilizer treatments, vegetation cover rates in forest floor increased significantly with the fertilization. These results suggest that the increase of pine seedling growth and vegetation cover rates with fertilization could enhance soil stabilization in forest tire areas.