• Title/Summary/Keyword: control period

Search Result 9,308, Processing Time 0.041 seconds

Effect of Cold Treatment for Mother Plants of New Strawberry Cultivars Bred in Korea on the Production of Runners and Daughter Plants (국내 육성 신품종 딸기의 모주 저온처리가 런너와 자묘의 발생에 미치는 영향)

  • Jun, Ha Jun;Jun, Eui Hwan;Kang, Su In;Bae, Keun Hye
    • Journal of Bio-Environment Control
    • /
    • v.24 no.1
    • /
    • pp.8-12
    • /
    • 2015
  • There are various limiting factors that take part in the production of daughter plants, but the important thing for mother plants of strawberries is to undergo a sufficient period of dormancy during winter. It is a well known fact that many runners and daughter plants are generated from mother plants that have been through sufficient cold treatment, but such researches were not found in Korea. This experiment was conducted due to the recent need for a research on the effects of cold treatment using 'Seolhyang,' 'Maehyang' and 'Ssanta' cultivars bred in Korea for two years in 2012 and 2013. The strawberries were divided into 4 types treatments: cold treatment plants in which 1,000 hours have passed in the temperature of $5^{\circ}C$ and below; cold+heated treatment plants in which 1,000 hours have passed in the temperature of $5^{\circ}C$ and below, and then 2 weeks in the greenhouse; greenhouse treatment plants raised in the greenhouse; and plants in harvest treatment. The results of the 2012 experiment showed that 'Seolhyang' had the bigger number of daughter plants in the cold, cold+heated, and harvest than greenhouse. 'Maehyang' had the biggest number of daughter plants in the cold+heated, and lowest in the greenhouse and harvest. 'Ssanta' had no significant difference in all treatments. The results of the 2013 experiment showed that 'Seolhyang' and 'Maehyang' both had more daughter plants in cold and cold+heated than in the greenhouse and harvest. 'Ssanta' tended to show a similar result and cold+heated had statistically more daughter plants than greenhouse.

Effect of Nutrient Solution Concentration on the Growth and Mineral Uptake of Various Wrap-up Vegetables and Herbs Grown with Mixed Planting in DFT Hydroponics (담액 수경재배 시 양액농도 처리가 혼식한 쌈 채소류와 허브류의 생육과 무기양분 흡수에 미치는 영향)

  • Seo, Tae-Cheol;Rho, Mi-Young;Gang, Nam-Jun;Lee, Seong-Chan;Choi, Young-Hah;Yun, Hyung-Kweon
    • Journal of Bio-Environment Control
    • /
    • v.16 no.4
    • /
    • pp.395-406
    • /
    • 2007
  • The twenty seven wrap-up vegetables (13 Compositae, 14 Brassicaceae) and seven herbs (6 Labiatae, 1 Umbelliferae) were cultivated with a deep flow technique (DFT) hydroponic beds and treated with 3 levels of nutrient solution concentrations of 1.2, 2.4, and $3.6dS{\cdot}m^{-1}$ in summer and autumn season. The pH and electrical conductivity (EC) change of nutrient solution, fresh weight, and mineral contents of plants were investigated. The pH was maintained lower in high electrical conductivity (EC) treatment and in summer than autumn. EC of nutrient solution in EC $3.6dS{\cdot}m^{-1}$ treatment increased up to $4.8dS{\cdot}m^{-1}$ during the growing period in summer season. The growth of tested plants showed high variations by plant species and nutrient solution concentrations. The coefficient variation (CV) of the shoot fresh weight of plants was higher in summer than autumn. The growth of Compostiae and herbs was better at EC $1.2dS{\cdot}m^{-1}$, and 14 Brassicaceae was better at EC $2.4dS{\cdot}m^{-1}$ in summer. In autumn, the growth was better at EC $2.4dS{\cdot}m^{-1}$ in all plants except kale 'TBC F1' and red rape 'honchaetae'. In mineral contents, total nitrogen and potassium were higher in autumn than summer. Total nitrogen, potassium, calcium, magnesium were higher in Brassicaceae than others. Iron and manganese, however, were higher in Compositae. As the results, this study suggests that mixed planting of 27 wrap-up vegetables and 7 herbs in DFT hydroponics in two seasons was possible and EC $1.2dS{\cdot}m^{-1}$ in summer and EC $2.4dS{\cdot}m^{-1}$ in autumn be recommended as for the nutrient solution concentration to produce them safely year round.

Growth and Physiological Adaptations of Tomato Plants (Lycopersicon esculentum Mill) in Response to Water Scarcity in Soil (토양 수분 결핍에 따른 토마토의 생육과 생리적응)

  • Hwang, Seung-Mi;Kwon, Taek-Ryun;Doh, Eun-Soo;Park, Me-Hea
    • Journal of Bio-Environment Control
    • /
    • v.19 no.4
    • /
    • pp.266-274
    • /
    • 2010
  • This study aim to investigate fundamentally the growth and physiological responses of tomato plants in responses to two different levels of water deficit, a weak drought stress (-25 kPa) and a severe drought stress (-100 kPa) in soil. The two levels of water deficit were maintained using a micro-irrigation system consisted of soil sensors for the real-time monitoring of soil water content and irrigation modules in a greenhouse experiment. Soil water contents were fluctuated throughout the 30 days treatment period but differed between the two treatments with the average -47 kPa in -25 kPa set treatment and the -119 kPa in -100 kPa set treatment. There were significant differences in plant height between the two different soil water statuses in plant height without differences of the number of nodes. The plants grown in the severe water-deficit treatment had greater accumulation of biomass than the plants in the weak water-deficit treatment. The severe water-deficit treatment (-119 kPa) also induced greater leaf area and leaf dry weight of the plants than the weak water-deficit treatment did, even though there was no difference in leaf area per unit dry weight. These results of growth parameters tested in this study indicate that the severe drought could cause an adaptation of tomato plants to the drought stress with the enhancement of biomass and leaf expansion without changes of leaf thickness. Greater relative water content of leaves and lower osmotic potential of sap expressed from turgid leaves were recorded in the severe water deficit treatment than in the weak water deficit treatment. This finding also postulated physiological adaptation to be better water status under drought stress. The drought imposition affected significantly on photosynthesis, water use efficiency and stomatal conductance of tomato plants. The severe water-deficit treatment increased PSII activities and water use efficiency, but decreased stomatal conductance than the weak water-deficit treatment. However, there were no differences between the two treatments in total photosynthetic capacity. Finally, there were no differences in the number and biomass of fruits. These results suggested that tomato plants have an ability to make adaptation to water deficit conditions through changes in leaf morphology, osmotic potentials, and water use efficiency as well as PSII activity. These adaptation responses should be considered in the screening of drought tolerance of tomato plants.

Fruit Characteristics of Gaeryangmeoru Grapes According to Gibberellic Acid and Thidiazuron Treatments (Gibberellic acid와 thidiazuron 처리에 의한 개량머루의 과실 특성)

  • Kwon, YongHee
    • Journal of Bio-Environment Control
    • /
    • v.23 no.2
    • /
    • pp.77-82
    • /
    • 2014
  • The present study was conducted to establish an effect and a proper concentration for treatment with gibberellic acid ($GA_3$) and thidiazuron (TDZ), resulting with increase berry size and yield in Gaeryangmeoru grapes. Berry size was increased by treatment with $GA_3$, and the fruit clusters obtained for the groups treated with $GA_3$ concentrations of 100 and $200mg{\cdot}L^{-1}$ were bigger. The berry number was also enhanced in $GA_3$ treated groups, but the soluble solid content and acidity was not significantly different. Damage caused by $GA_3$ treatment, such as peel pollination and berry shatter, was observed in the group with $200mg{\cdot}L^{-1}$. The berry size was larger in group treated with a high concentration of $GA_3$ and TDZ respectively than in those treated with low concentrations in the treatment mixed $GA_3$ and TDZ; however, fruit with low soluble solid content and high acidity was harvested after $GA_3$ and TDZ treatment due to delay of berry ripening. The pericarp tissue layers were not changed, but the distance from the epidermis layer to vascular bundle tissue was increased as a result of $GA_3$ and TDZ treatment. Therefore, $GA_3$ and TDZ did not affect an cell division but not cell size, resulting in an enlarged berry size. It is necessary to treat plant growth regulators 2~3 times and immediately after berry set to enhance berry set rate, because the period of berry set is short. This study suggests that the proper concentration for enhancing berry size and set were up to $100mg{\cdot}L^1$ $GA_3$ or $50mg{\cdot}L^{-1}GA_3+1.25mg{\cdot}L^{-1}$ TDZ, and it is necessary to pay attention to harvest mature fruits because of the delay of ripening caused by the usage of TDZ.

Field Survey on the Maintenance Status of Greenhouses in Korea (온실의 유지관리 실태조사 분석)

  • Choi, Man Kwon;Yun, Sung Wook;Kim, Hyeon Tae;Lee, Si Young;Yoon, Yong Cheol
    • Journal of Bio-Environment Control
    • /
    • v.23 no.2
    • /
    • pp.148-157
    • /
    • 2014
  • The purpose of this study was to investigate greenhouse maintenance by farms by looking into greenhouses across the nation for greenhouse specification, disaster-resistance greenhouse construction, types and degree of damage due to natural disasters, pre-inspection in case of typhoon or heavy snow forecast, and fire-fighting facilities to prevent a fire. The findings were summarized as follows: as for greenhouse specification, the highest proportion of them were 90 m or longer both in single- and multi-span greenhouses in terms of length; 8 m or wider and 7.0~7.9 m in single- and multi-span greenhouses, respectively, in terms of width; 1.5~1.9 m and 2.0~2.9 m in single-and multi-span greenhouses, respectively, in terms of height; and 3.0~3.9 m and 6 m in single- and multi-span greenhouses, respectively, in terms of diameter. As for disaster-resistance greenhouses, farmers were reluctant to install such greenhouses. The low distribution of disaster-resistance greenhouses was attributed to the greenhouses built dependent on the old practice, the greenhouses already completed, and relatively high construction costs. As for damage by natural disasters, greenhouses were subject to more damage by typhoons than heavy snow. They mainly inspected the ceiling and side windows, entrances, and fixation bands for covering materials in case of typhoon forecast and the heating devices in case of heavy snow forecast. As for repair methods for greenhouse pipe corrosion, they preferred partial replacement to painting and did not use stiffeners for structures to prevent a natural disaster in most cases. As for the maintenance of greenhouse covering materials, most farmers inspected their sealing property but did not clean the coverings for light transmission. The destruction of structural materials can be prevented by eliminating greenhouse covering materials during a typhoon, but they were not able to do so because of the covering material replacement costs and the crops they were growing. The study also examined whether greenhouse farms had fire-fighting facilities to prevent a fire and found that they lacked the perception of greenhouse fire prevention to a great degree.

Heating Performance Analysis of the Heat Pump System for Agricultural Facilities using the Waste Heat of the Thermal Power Plant as Heat Source (발전소 폐열을 이용한 농업시설용 히트펌프시스템의 난방 성능 분석)

  • Kang, Youn Koo;Kang, Suk Won;Paek, Yee;Kim, Young Hwa;Jang, Jae Kyung;Ryou, Young Sun
    • Journal of Bio-Environment Control
    • /
    • v.26 no.4
    • /
    • pp.317-323
    • /
    • 2017
  • In this study, the heating performance and the energy saving effect of the heat pump system using hot waste water(waste heat) of the thermal power plant discharged from a thermal power plant to the sea were analyzed. The greenhouse area was $5,280m^2$ and scale of the heat pump system was 120 RT(Refrigeration Ton), which was divided into 30 RT, 40 RT and 50 RT. The heat pump system consisted of the roll type heat exchangers, hot waste water transfer pipes, heat pumps(30, 40, 50 RT), a heat storage tank and fan coil units. The roll type heat exchangers was made of PE(Poly Ethylene) pipes in consideration of low cost and durability against corrosion, because hot waste water(sea water) is highly corrosive. And the heating period was 5 months from October to February. During the heating performance test(12 hours), the inlet water temperature of evaporator was changed from $32^{\circ}C$ to $26^{\circ}C$, and heat absorption of he evaporator was changed from 175 kW to 120 kW. The inlet water temperature of the condenser rose linearly from $15^{\circ}C$ to $50^{\circ}C$, and the heat release of condenser was reduced by 40 kW from 200 kW to 160 kW. And the power consumption of the heat pump system increased from 30 kW to 42 kW. When the inlet water temperature of condenser was $15^{\circ}C$, the heating COP(Coefficient Of Performance) was over 7.0. When it was $30^{\circ}C$, it dropped to 5.0, and when it was above $40^{\circ}C$, it decreased to less than 4.0. It was analyzed that the reduction of heating energy cost was 87% when compared to the duty free diesel that the carbon dioxide emission reduction effect was 62% by recycling the waste heat of the thermal power plant as a heat source of the heat pump system.

Comparison of Heating Characteristics of Electric Heating Element Heater and Oil Hot Air Heater in Single Span Greenhouses (전기발열체 난방기 및 유류온풍 난방기의 단동온실 난방 특성 비교)

  • Kwon, Jin Kyung;Kim, Seung Hee;Shin, Young An;Lee, Jae Han;Park, Kyeong Sub;Kang, Youn Koo
    • Journal of Bio-Environment Control
    • /
    • v.26 no.4
    • /
    • pp.324-332
    • /
    • 2017
  • The comparative experiments were conducted for single span greenhouses where cucumbers were cultivated to analyze the effect of heating between a carbon fiber electric heating element heater and an oil hot air heater in terms of the inside climate, energy consumption and plant growth. In order to analyze the effect of heating capacity, 6, 9, and 16 kW of electric powers were supplied to the electric heating element for same setting temperature of 15?. As a result, as the heating capacity increased, the number of ON-OFF cycles of the electric heating element and the temperature inside the greenhouse increased proportionally. In the comparison of two heaters, it was shown that the temperature and relative humidity distributions of the electric heating element installed greenhouse was much uniform than those of the oil hot air heater installed greenhouse. The heating energy consumptions during the heating period of 79 days were 867L for the oil hot air heater and 8,959 kWh for the electric heating element heater, and the heating costs were 607 and 403 thousand won respectively. In the electric heating element installed greenhouse, the cucumber growth was slightly better and the yield was 4.3% higher than those of the oil hot air heater installed greenhouse, but there were no statically significant difference in the cucumber growth and yield between greenhouses.

Comparison of Center Error or X-ray Field and Light Field Size of Diagnostic Digital X-ray Unit according to the Hospital Grade (병원 등급에 따른 X선조사야와 광조사야 간의 면적 및 중심점 오차 비교)

  • Lee, Won-Jeong;Song, Gyu-Ri;Shin, Hyun-yi
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.245-252
    • /
    • 2020
  • The purpose of this study was intended to recognize the importance of quality control (QC) in order to reduce exposure and improve image quality by comparing the center-point (CP) of according to hospital grade and the difference between X-ray field (XF) and light field (LF) in diagnostic digital X-ray devices. XF and LF size, CP were measured in 12 digital X-ray devices at 10 hospitals located in 00 metropolitan cities. Phantom was made in different width respectively, using 0.8 mm wire after attaching to the standardized graph paper on transparent plastic plate and marked as cross wire in the center of the phantom. After placing the phantom on the table of the digital X-ray device, the images were obtained by shooting it vertically each field of survey. All images were acquired under the same conditions of exposure at distance of 100cm between the focus-detector. XF and LF size, CP error were measured using the picture archiving communication system. data were expressed as mean with standard error and then analyzed using SPSS ver. 22.0. The difference in field between the XF and LF size was the smallest in clinic, followed by university hospitals, hospitals and general hospitals. Based on the university hospitals with the least CP error, there was a statistically significant difference in CP error between university hospitals and clinics (p=0.024). Group less than 36-month after QC had fewer statistical errors than 36-month group (0.26 vs. 0.88, p=0.036). The difference between the XF and LF size was the lowest in clinic and CP error was the lowest in university hospital. Moreover, hospitals with short period of time after QC have fewer CP error and it means that introduction of timely QC according to the QC items is essential.

The Relationship of between Anxiety Tendency and Recurrent Abdominal Pain in Elementary School Children (학동기 소아에서 반복성 재발성 복통과 불안 성향과의 관련성)

  • Moon, Ji-Young;Moon, Kyung-Rye
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.10 no.2
    • /
    • pp.129-137
    • /
    • 2007
  • Purpose: It has been reported that children with chronic pain have higher levels of anxiety than age-matched controls. Therefore, this study was designed to determine the relationship between anxiety and recurrent abdominal pain in elementary school children. Methods: In 2005, we surveyed 1,254 elementary school children (592 boys and 662 girls) whose ages ranged from 7 to 12 years. The degree of trait and state anxiety was compared between agroup suffering from intermittent abdominal pain, a group suffering from recurrent abdominal pain and a normal control group following the Korean version of Spielberger's State-Trait Anxiety Inventory YZ form (STAI-YZ). Results: 709 (56.5%) and 69 (5.5%) of the patients reported intermittent abdominal pain and and recurrent abdominal pain, respectively, during the 12 month period before this study was conducted, and trait and state anxiety values for each of these groups was 116 (9.3%) and 63 (5.0%), respectively. In addition, the State-Trait Anxiety score was significantly higher in the group with intermittent abdominal pain and RAP than the anxiety score of the normal control group. Additionally, the STAI-YZ score increased in proportion to the severity of abdominal pain, but was not correlated with the duration, frequency, onset time or location of abdominal pain. Furthermore, the proportion of the group with abdominal pain in the group that had trait or state anxiety was significantly higher than the proportion of the group that did not have trait and state anxiety. Conclusion: Recurrent abdominal pain during childhood is correlated with state and trait anxiety, therefore, psychological factors, such as anxiety duringtreatment, must also be considered when determining the cause of recurrent abdominal pain.

  • PDF

Effects of Feeding Induced Molting on the Performance, Egg Quality, and Visceral Organs in Laying Hens (산란계에서 급이환우가 산란계의 생산성과 계란의 품질 및 주요 장기에 미치는 영향)

  • Hong, E.C.;Na, J.C.;You, D.C.;Jang, B.G.;Kim, H.K.;Choi, Y.H.;Park, H.D.;HwangBo, J.
    • Korean Journal of Poultry Science
    • /
    • v.34 no.3
    • /
    • pp.197-205
    • /
    • 2007
  • This study was conducted to compare the effect of feeding molting and fasting molting on the performance, egg quality, and visceral organs in laying hens for animal welfare. Eighty one 62-wk-old White Leghorn hens that egg production was over 80% and average weight was $1.6{\pm}0.3\;kg$ were used in this study. Treatments were control (non-molt treatment), feeding molt treatment, and fasting molt treatment. The three treatments were administered to three replicate group of nine hens wherein each group. All treatment groups were fed the basal diet (CP 15%, ME 2,700 kal/kg) for two weeks as the adaptation period. Induced molt diets contains low CP (6.7%) and low energy (2,200 kal/kg). Test periods were 14 days for feeding molting and 10 days for fasting molting. Egg production decreased to be 0% at 10 days of feeding molting treatment, but at 2 or 3 days of fasting molting treatment. Egg production restarted after 19 days ending molt at feeding molting treatment, while after 24 days at fasting molting treatment. On the egg quality was improved at molting treatments (p<0.05) except egg yolk. Egg shell tissue was crowded at molting treatment to compare to control. Liver weights, heart weight, and oviduct weight of laying hens decreased at molting treatments (p<0.05). Finally, feeding molting might could be replaced fasting molting on the welfare and further studies were needed about molting program.