• Title/Summary/Keyword: control leakage

Search Result 935, Processing Time 0.025 seconds

Labyrinth Seal Design Considering Leakage Flow Rate and Rotordynamic Performance (누설유량과 회전체동역학적 성능을 고려한 래버린스 씰 설계)

  • Minju Moon;Jeongin Lee;Junho Suh
    • Tribology and Lubricants
    • /
    • v.39 no.2
    • /
    • pp.61-71
    • /
    • 2023
  • This study proposes a procedure for designing a labyrinth seal that meets both leakage flow rate and rotordynamic performance criteria (effective damping, amplification factor, separation margin, logarithmic decrement, and vibration amplitude). The seal is modeled using a one control volume (1CV) bulk flow approach to predict the leakage flow rate and rotordynamic coefficients. The rotating shaft is modeled with the finite element (FE) method and is assumed to be supported by two linearized bearings. Geometry, material and operating conditions of the rotating shaft, and the supporting characteristics of the bearings were fixed. A single labyrinth seal is placed at the center of the rotor, and the linearized dynamic coefficients predicted by the seal numerical model are inserted as linear springs and dampers at the seal position. Seal designs that satisfy both leakage and rotordynamic performance are searched by modifying five seal design parameters using the multi-grid method. The five design parameters include pre-swirl ratio, number of teeth, tooth pitch, tooth height and tooth tip width. In total, 12500 seal models are examined and the optimal seal design is selected. Finally, normalization was performed to select the optimal labyrinth seal designs that satisfy the system performance requirements.

A Study on Dynamic Characteristics of Electrical Fire Prevention Control Devices with a lamp and a motor load (전등 부하 및 전동기 부하시 전기화재예방 제어장치의 동작 특성에 관한 연구)

  • Lee, Sang-Ho;Oh, Hong-Seok
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.5 no.3
    • /
    • pp.255-260
    • /
    • 2002
  • Recently, the occurrences of electrical fire have been suppressed by an earth leakage breaker(ELB), a no fuse breaker(NFB) and a fuse in case of an earth leakage, a short circuit and an over current. But it is impossible for the ELB to break the circuit in the case of the failure of pressure contacts on connecting points and the momentary short circuit. Therefore, it is require to study the constructive problem of the ELB. In this paper, we have developed the auxiliary control device, electrical fire prevention control device(EFPCD), of the ELB. And we have tested the operation characteristics of the ELB according to the load(R, L) As a result of this experiment, we could prevent the electrical fire due to the spark and the overheat occurring in the failure of pressure contacts on connecting points and the momentary short circuit.

  • PDF

Analysis of Interleaving Effect for Toroidal Type Transformer Windings (토로이달 타입 변압기 권선의 Interleaving 효과 분석)

  • Shin, Kyoung-Gu;Kang, Byeong-Geuk;Chung, Se-Kyo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.3
    • /
    • pp.255-261
    • /
    • 2015
  • An analysis of the interleaving effect for the secondary winding distribution of a toroidal transformer is presented in this paper. The equations to calculate the leakage inductance of the toroidal transformer are derived using MMF diagrams for the different secondary winding distributions. The simulation and experimental results are provided to show the validity of the theoretical calculation.

A Study on the Trouble of Turbine EHC System by Chloride (염소성분에 의한 터빈 EHC계통 손상에 관한 연구)

  • Kim, Seung Min;Yang, Cheon Gyu;Yoon, Gi Nam;Jung, Jae Won;Shin, Yeul Young
    • 유체기계공업학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.366-372
    • /
    • 2000
  • In a power plant, it is generally accepted that a turbine governor system is necessary to control amount of steam supply toward the turbine system. There are many kinds of trouble at this governor system, which is recognized one of the most sensitive systems in the power plant. Especially we have experienced the internal leakage of motorization oil of servo valve. In the study, we investigated the mechanism of an internal leakage such as erosion by foreign materials and corrosion by chemical reaction between chloric healed oil and motorization oil. A precautionary measures is also performed to help the field service engineers.

  • PDF

An Implementation Method of Improved Document DRM for Preventing Information Leakage using RBAC Approach (RBAC을 이용한 정보유출 방지를 위한 보안성이 강화된 문서 DRM 구현)

  • Choi, Young Hyun;Eom, Jung Ho;Chung, Tai Myoung
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.7 no.4
    • /
    • pp.57-66
    • /
    • 2011
  • We implemented the document DRM applying role based access control(RBAC) mechanism for preventing the information leakage of a document which is transmitted in network environment. It must prevent to access document not related to user role and duty, and must allow operation to document for improving security, considering user role and security level according to a document importance. We improved the security of document DRM by adding to the access control module applying RBAC for satisfying security requirements. Though the user access document, our system allows operation authorizations to document by the user's role & security level and the security attribute of RBAC. Our system prevents indiscriminate access to the documents by user who is not associated with the role, and prevents damage the confidentiality and integrity.

Development of an Architecture Monitoring System Using Wireless Sensor Network (무선 센서네트워크를 이용한 건축물 모니터링 시스템 구현)

  • Chang, Hyung-Jun;Kim, Beom-Soo;Kong, Young-Bae;Park, Gwi-Tae;Shim, II-Joo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.6
    • /
    • pp.568-573
    • /
    • 2007
  • Environmental information (temperature, humidity, vibration, $CO_2$, gas leakage, etc.) of building is an essential item to manage and monitor a building. For intelligent building, it is necessary to get temperature and illumination information to save energy and crack information to prevent structural problems. Moreover, temperature and gas leakage information to alarm a tire precaution, or humidity information to maintain comfortable environment. However, there have not been many researches on systems for gathering environmental information and building maintenance due to high costs. In this paper, wireless sensor network technology is applied to collecting building environmental information. Wireless sensor network is one of the latest issues and has low-power consumption, low-cost, self-configuration features.

System of gas sensor for conbinating wire and wireless using Internet of Things (IOT기술을 이용한 유무선 통합 가스검출 시스템 구현)

  • Bang, Yong-Ki;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.4
    • /
    • pp.297-304
    • /
    • 2015
  • This study concerns the integrated gas sensor system of wire and wireless communication by using IoT(Internet of Things) technology. First, communication part is that it delivers the detection information, which transferred by wire or wireless communication and required control procedure based on a wireless module that receives the gas leakage information from wired or wireless detector, to administrator or user's terminal. Second, receiver part is that it shows the location and information, which received from the wired detector formed by a detecting sensor's node as linking with the communication part, and transfers these to the communication part. Third, wireless detector formed as a communication module of a detecting sensor node is that it detects gas leakage and transfers the information through wireless as a packet.Fourth, wired detector communicated with the receiver part and formed as a communication module of a detecting sensor node is that it detects gas leakage, transfers and shows the information as a packet. Fifth, administrator's terminal is that it receives gas leakage information by the communication part, transfers the signal by remote-control, and shut off a gas valve as responding the information. Sixth, database is that it is connected with the communication part; it sets and stores the default values for detecting smoke, CO., and temperature; it transfers this information to the communication part or sends a gas detecting signal to user's terminal. Seventh, user's terminal is that it receives each location's default value which stored and set at the database; it manages emergency situation as shutting off a gas valve through remote control by corresponding each location's gas leakage information, which transferred from the detector to the communication part by wireless.It is possible to process a high quality data regarding flammable or toxic gas by transferring the data, which measured by a sensor module of detector, to the communication part through wire and wireless. And, it allows a user to find the location by a smart phone where gas leaks. Eventually, it minimizes human life or property loss by having stability on gas leakage as well as corresponding each location's information quickly.

The Design of Information Security Management System for SMEs Industry Technique Leakage Prevention (중소기업 산업기술 유출방지를 위한 정보보호 관리체계 설계)

  • Chang, Hang-Bae
    • Journal of Korea Multimedia Society
    • /
    • v.13 no.1
    • /
    • pp.111-121
    • /
    • 2010
  • Since SMEs have recognized needs for industrial technique leakage prevention, they tend to construct information security system causing huge consumption of budget, yet they cannot organize information security team to operate integrated information security management system with consistency and it is fact that there only occur instant introductions of certain system. In this study, we designed information security management system for SMEs' industrial technique leakage prevention which is differentiated from those of large enterprises based on current status of SMEs' industrial technique leakage. Specifically we analyzed current status and vulnerability of SMEs' industrial technique leakage and we designed industrial technique leakage prevention management system for SMEs. Then we applied Delphi method to validate appropriateness of study result. We strongly believe that SMEs may estimate a appropriate level of investment on information security and develop countermeasures for control by utilizing this study result.

A COMPARISON OF THE APICAL SEALING ABILITY OF OBTURATION TECHNIQUES BY THERMALLY SOFTENED GUTTA PERCHA (열연화시킨 근관충전방법에 따른 근단폐쇄성에 관한 연구)

  • Baek, Seung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.2
    • /
    • pp.607-617
    • /
    • 1998
  • The purpose of this study was to evaluate the apical sealing ability of lateral condensation method, vertical condensation method, and MicroSeal obturation system. Sixty-four extracted anterior teeth were instrumented to #40 using Profile. Three groups of 20 teeth were obturated by lateral condensation technique, vertical condensation technique, and and MicroSeal obturation system. Control group were not obturated. Teeth were immersed in resorcinol-formaldehyde resin for 5 days at $4^{\circ}C$, and the resin was allowed to polymerize completely for 4 days at room temperature. Teeth were ground horizontally at 1,5mm(level 1), 2.5mm(level 2), and 3.5mm(level 3) from the anatomic apex and examined with a stereomicroscope at X40 magnification. The photographs were taken a at X40 magnification of the filling in each level and scanned. The leakage area, which was filled with the resin, was measured at each of the three levels. Each ratio of leakage was evaluated by calculating the ratio of thearea of the resin to the total area of the canal and was analyzed statistically. The results were as followed: 1. Vertical condensation group had significantly higher percentage of the area which was obturated by gutta percha than other two technique at each level. 2. At the level 1, there was the greatest leakage in the lateral condensation group, but there was no statistically significant(P>0.05) 3. At the level 2, there was the least leakage in the MicroSeal group, and the most leakage in the lateral condensation group. There was statistically significant difference between the MicroSeal group and the lateral condensation group(P<0.05). 4. At the level 3, there was least leakage in the vertical condensation group, and the most leakage in the lateral condensation group. There was statistically significant difference between the vertical condensation group and the lateral condensation group(P<0.05).

  • PDF

Robotic Agent Design and Application in the Ubiquitous Intelligent Space (유비쿼터스 지능형 공간에서의 로봇 에이전트 설계 및 응용)

  • Yoon Han-Ul;Hwang Se-Hee;Kim Dae-Wook;Lee Doong-Hoon;Sim Kwee-Bo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.11 no.12
    • /
    • pp.1039-1044
    • /
    • 2005
  • This paper presents a robotic agent design and application in the ubiquitous intelligent space. We set up an experimental environment with Bluetooth host, Bluetooth client, furniture and home appliance, and robotic agents. First, the agents basically performed patrol guard to detect unexpected penetration, and to keep home safely from gas-leakage, electric leakage, and so on. They were out to patrol fur a robbery while navigating in a living room and a private room. In this task, we used an area-based action making and a hexagon-based Q-learning to control the agents. Second, the agents communicate with Bluetooth host device to access and control a home appliance. The Bluetooth host offers a manual control to person by inquiring a client robot when one would like to check some place especially. In this exercise, we organize asynchronous connection less (ACL) between the host and the client robots and control the robot maneuver by Bluetooth host controller interface (HCI).