Evaluation of Corrosion Characteristics on Welding Zone of Leakage SeawaterPipe Welded by Underwater Welding Electrode (수중 용접봉으로 용접한 누수배관 용접부위의 부식 특성 평가)

  • Moon, Kyung-Man;Lee, Sung-Yul;Kim, Yun-Hae;Lee, Myung-Hyoon;Kim, Jin-Gyeong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.8
    • /
    • pp.1240-1247
    • /
    • 2008
  • Leakage trouble on the sea water pipeline in engine room is often resulted from a localized corrosion due to severe corrosive environment caused by both high speed and high pressure of sea water flowing through the inner pipe. In addition, when the ship is in stand-by or emergency condition, underwater welding to control the leakage of sea water from a hole of its pipe is very important in an industrial safety point of view. In this study possibility of underwater welding to control leakage of sea water and corrosion property of its welding zone were investigated with the electrochemical methods by parameters of welding methods and welding electrodes when underwater welding is achieved with a such case that sea water is being leaked out with a height at 50mm from a hole of $2.5mm{\emptyset}$ of test pipe. Corrosion resistance of weld metal zone is better than the base metal and its hardness is higher than that of the base metal. However corrosion potential of weld metal zone showed a negative value than that of the base metal, therefore weld metal zone is preferentially corroded rather than the base metal by performance of galvanic cell due to difference of corrosion potential between weld metal zone and base metal. Eventually it is suggested that leakage of sea water is successfully controlled by underwater welding,

A Study on Automatic Sensing Device for Water Leakage of Cooling Pipe at Blast Furnace by Use The Electronic System (전자제어 장치를 이용한 용광로 냉각관 누수 지동 감지장치 개발에 관한 연구)

  • Kang, Chang-Soo;Kang, Ki-Seong
    • 전자공학회논문지 IE
    • /
    • v.46 no.4
    • /
    • pp.25-30
    • /
    • 2009
  • The cooling water circulation pipes had been used to drop the temperature of refractory outside shell of blast furnace by cooling plate or stave type. They were attacked by surrounding CO gas and it was the cause that they were corroded and the water inflow in the refractory due to leakage of water. So, the life of refractory material was shorten and changed for the worse the conditions of blast furnace. The automatic sensing device for water leakage of cooling pipe was developed to check the position of trouble by use the micro-process system when cooling water leak and then CO gas will be inflowed into the cooling pipe at the leakage position. The inflowed CO gas will be detected in the micro-process system and delivered the detected position of cooling plate or stave to main control room through the wireless-radio relay station. This system can be possible to detect the position of cooling plate or stave the water leakage part immediately and then deliver the signal to main control room by use the micro-process system and wireless-radio relay station. This system will develop the working condition from manual system to unmanned auto alarm system.

MARGINAL ADAPTATION OF COMPOSITE RESIN USING GLASS IONOMER CEMENT BASES (Glass ionomer cement를 이장한 Composite resin의 변연 적합성에 관한 연구)

  • Han, Seung-Weon
    • Restorative Dentistry and Endodontics
    • /
    • v.14 no.2
    • /
    • pp.5-19
    • /
    • 1989
  • The purpose of this study was to observe the microleakage of composite resin filling using several glass ionomer cements. The Class V cavities of eighty noncarious human molars were prepared at the cementoenamel juction on the facial and lingual surfaces of each tooth with a No.330 carbide bur in a high speed handpiece. The cavity dimensions were $3.0{\pm}0.5mm$ wide, $2.0{\pm}0.5mm$ high, and $1.5{\pm}0.5mm$ deep and all enamel cavosurface margins were beveled with a No.558 carbide bur in low speed handpiece. The bevel was approximately $45^{\circ}$ and 0.5-1.0mm in width. A total of the 160 cavities was divided into four groups, and then 144 cavities among them were three experimental groups and remaining sixteen cavities were control group. All of the prepared cavities were restored as follows: group 1 : Preparations were restored with there three glass ionomer cements. group 2 : Preparations were restored with a composite resin with three glass ionomer cement bases placed $0.2{\pm}0.1mm$ short of the cavosurface margin. group 3 : Preparations were restored with a composite resin with three glass ionomer cement bases extened to the cavosurface margin. group 4 : As control group, preparations were restored with a composite resin, PALFIQUE. The specimens were then thermocycled in a range of $6^{\circ}C-60^{\circ}C$ and immersed in a bath of 2.0% aqueous basic fuchsin solution for 24 hours. Dye penetration was read on a scale of 0 to 4 by Tani and Buonocore's method. The following conclusions were derived from the results obtained; 1. All groups showed significantly more leakage at the gingival margins than at the occlusal margins(p<0.0005). 2. At the gingival margins, group 1 showed less leakage than group 3(p<0.01) and group 4(p<0.0005), while group 3 exhibited less leakage than group 2(p<0.01) and group 4(p<0.0005). 3. At the occlusal margins, group 4 showed less leakage than group 3(p<0.1) and group 1(p<0.005), while group 3 exhibited less leakage than group 2(p>0.1) and group 1(p<0.025).

  • PDF

Variations of Air Temperature, Relative Humidity and Pressure in a Low Pressure Chamber for Plant Growth (식물생장용 저압챔버 내의 기온, 상대습도 및 압력의 변화)

  • Park, Jong-Hyun;Kim, Yong-Hyeon
    • Journal of Bio-Environment Control
    • /
    • v.18 no.3
    • /
    • pp.200-207
    • /
    • 2009
  • This study was conducted to analyze the variations of air temperature, relative humidity and pressure in a low pressure chamber for plant growth. The low pressure chamber was composed of an acrylic cylinder, a stainless plate, a mass flow controller, an elastomer pressure controller, a read-out-box, a vacuum pump, and sensors of air temperature, relative humidity, and pressure. The pressure leakage in the low pressure chamber was greatly affected by the material and connection method of tubes. The leakage rate in the low pressure chamber with the welding of the stainless tubes and a plate decreased by $0.21kPa{\cdot}h^{-1}$, whereas the leakage in the low pressure chamber with teflon tube and rubber O-ring was given by $1.03kPa{\cdot}h^{-1}$. Pressure in the low pressure chamber was sensitively fluctuated by the air temperature inside the chamber. An elastomer pressure controller was installed to keep the pressure in the low pressure chamber at a setting value. However, inside relative humidity at dark period increased to saturation level.. Two levels (25 and 50kPa) of pressure and two levels (500 and 1,000sccm) of mass flow rate were provided to investigate the effect of low pressure and mass flow rate on relative humidity inside the chamber. It was concluded that low setting value of pressure and high mass flow rate of mixed gas were the effective methods to control the pressure and to suppress the excessive rise of relative humidity inside the chamber.

A Study of Network 2-Factor Access Control Model for Prevention the Medical-Data Leakage (의료 정보유출 방지를 위한 네트워크 이중 접근통제 모델 연구)

  • Choi, Kyong-Ho;Kang, Sung-Kwan;Chung, Kyung-Yong;Lee, Jung-Hyun
    • Journal of Digital Convergence
    • /
    • v.10 no.6
    • /
    • pp.341-347
    • /
    • 2012
  • Network Access Control system of medical asset protection solutions that installation and operation on system and network to provide a process that to access internal network after verifying the safety of information communication devices. However, there are still the internal medical-data leakage threats due to spoof of authorized devices and unauthorized using of users are away hours. In this paper, Network 2-Factor Access Control Model proposed for prevention the medical-data leakage by improving the current Network Access Control system. The proposed Network 2-Factor Access Control Model allowed to access the internal network only actual users located in specific place within the organization and used authorized devices. Therefore, the proposed model to provide a safety medical asset environment that protecting medical-data by blocking unauthorized access to the internal network and unnecessary internet access of authorized users and devices.

An Architecture of Access Control Model for Preventing Illegal Information Leakage by Insider (내부자의 불법적 정보 유출 차단을 위한 접근통제 모델 설계)

  • Eom, Jung-Ho;Park, Seon-Ho;Chung, Tai-M.
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.20 no.5
    • /
    • pp.59-67
    • /
    • 2010
  • In the paper, we proposed an IM-ACM(Insider Misuse-Access Control Model) for preventing illegal information leakage by insider who exploits his legal rights in the ubiquitous computing environment. The IM-ACM can monitor whether insider uses data rightly using misuse monitor add to CA-TRBAC(Context Aware-Task Role Based Access Control) which permits access authorization according to user role, context role, task and entity's security attributes. It is difficult to prevent information leakage by insider because of access to legal rights, a wealth of knowledge about the system. The IM-ACM can prevent the information flow between objects which have the different security levels using context role and security attributes and prevent an insider misuse by misuse monitor which comparing an insider actual processing behavior to an insider possible work process pattern drawing on the current defined profile of insider's process.

Safety analysis and design of full balanced hoist vertical shiplifts

  • Liao, Lekang
    • Structural Engineering and Mechanics
    • /
    • v.49 no.3
    • /
    • pp.311-327
    • /
    • 2014
  • The safety relating to leakage of water and pitch instability of ship chambers of the full balanced hoist vertical shiplifts has been the focus of adoption of the type of vertical shiplifts. This paper aims to remove the doubts through theoretical and engineering researches. The leakage and pitch stability of ship chambers of full balanced hoist vertical ship lifts are investigated on the basis of theoretical analysis and exploration of engineering measures. Regarding the issue of leakage of ship chambers, a mathematical model on leaking process is built and corresponding formula and coping measures are obtained which can be applied in control program of ship lifts by linking with monitoring. The concept of safety grade is put forward to seek the best technical and economic index and the corresponding technical measures are for different grades of ship lift is suggested. For the issue of pitch instability, a methodology of combining theoretical deduction and summary of achievements of design and operation of the type of the full balanced hoist shiplifts is adopted, and the formula for design about pitch stability of ship chambers is derived.

ELECTROCHEMICAL STUDY ON THE SEALING EFFECT OF CALCIUM HYDROXIDE-BASED SEALERS (수종 수산화칼슘 Sealer의 근관폐쇄효과에 관한 전기화학적연구)

  • Choi, Kook-Ryeol;Hong, Chan-Ui;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.1
    • /
    • pp.164-172
    • /
    • 1995
  • The purpose of this electrochemical study was to determine and compare the sealing effect of three commonly used calcium hydroxide-based sealers (Sealapex, Apexit, and CRCS) with that of Roth 801 which is a ZOE-based sealer. 64 single rooted teeth were used in this experiment. After removing the crown, the teeth were devided into 4 groups of 15 in each and obturated with gutta-percha and experimental sealers. 4 teeth were as controls(2 positive and 2 negative). The results were as follows : 1. During the observation period, all sealers showed varying degree of microleakage. 2. The mean leakage currents according to the electrochemical study of each group showed $0.418{\pm}0.006mV$ for Roth 801, $2.03{\pm}0.035mV$ for Sealapex, $3.33{\pm}0.069mV$ for Apxit and $6.48{\pm}0.097mV$ for CRCS group. The positive control group showed 600mV. 3. There were statistically significant difference in mean leakage among experimental groups. ZOE-typed Roth 801 sealer was the lowest, and Sealapex, Apexit, CRCS group in that order showed increased leakage(P<0.05). 4. Roth 801, Sealapex and Apexit group showed increasing leakage with time, but CRCS group showed stable or decreasing leakage tendency.

  • PDF

Design Effect of Sealing Characteristics of Non-Contact Type Seal for High Speed Spindle (형상설계에 관한 고속주축용 비접촉 시일의 밀봉특성 연구)

  • 나병철;전경진;한동철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.610-614
    • /
    • 1996
  • Sealing of lubricat-air mixture in the high performance machining conte is one of most the important characteristics to carry out enhanced lubrication. High speed spindle requires non-contact type of sealing mechanism. Evaluating an optimum seal design to minimize leakage is concerned in the aspect of flow control. Effect of geometry and leakage path are evaluated according to variation of sealing geometry, Velocity, pressure, turbulence intensity of profile is calculated to fina more efficient geometry and variables. This offers a methodological way of enhancement seal design for high speed spindle. The working fluid is regarded as two phases that are mixed flow of oil phase and air phase. It is more reasonable to simulate an oil jet or oil mist type high speed spindle lubrication. Turbulence and compressible flow model are used to evaluate a flow characteristic, This paper arranges a geometry of mostly used non-contact type seal and analyzes leakage characteristics to minimize a leakage on the same sealing area.

  • PDF

Labyrinth Seal Design Considering Leakage Flow Rate and Rotordynamic Performance (누설유량과 회전체동역학적 성능을 고려한 래버린스 씰 설계)

  • Minju Moon;Jeongin Lee;Junho Suh
    • Tribology and Lubricants
    • /
    • v.39 no.2
    • /
    • pp.61-71
    • /
    • 2023
  • This study proposes a procedure for designing a labyrinth seal that meets both leakage flow rate and rotordynamic performance criteria (effective damping, amplification factor, separation margin, logarithmic decrement, and vibration amplitude). The seal is modeled using a one control volume (1CV) bulk flow approach to predict the leakage flow rate and rotordynamic coefficients. The rotating shaft is modeled with the finite element (FE) method and is assumed to be supported by two linearized bearings. Geometry, material and operating conditions of the rotating shaft, and the supporting characteristics of the bearings were fixed. A single labyrinth seal is placed at the center of the rotor, and the linearized dynamic coefficients predicted by the seal numerical model are inserted as linear springs and dampers at the seal position. Seal designs that satisfy both leakage and rotordynamic performance are searched by modifying five seal design parameters using the multi-grid method. The five design parameters include pre-swirl ratio, number of teeth, tooth pitch, tooth height and tooth tip width. In total, 12500 seal models are examined and the optimal seal design is selected. Finally, normalization was performed to select the optimal labyrinth seal designs that satisfy the system performance requirements.