• Title/Summary/Keyword: control device for PM

Search Result 118, Processing Time 0.026 seconds

Development of a Low-cost Metering Device for Automatic Mixing of Nutrient-Solution

  • Ryu, K.H.;Lee, K.C.;Lee, J.H.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.1117-1125
    • /
    • 1996
  • A low-cost and precise metering device, which is suitable to automatic mixing of nutrient-solution for hydroponic culture, was developed for small-scale growers. The metering accuracy of the metering device developed was compared with commercial metering pumps. The mixing performance through the control of EC and pH was also evaluated. The accuracy of the metering device in terms of the full -scale error was $\pm$0.3% , which was much better compared to $\pm$2.45% and $\pm$1.38% for the two types of commercial metering pumps. The mixing system of nutrient-solution with the metering device showed a satisfactory control performance with the accuracies of $\pm$0.05mS/cm and$\pm$0.2pH for EC and pH, respectively.

  • PDF

Reduction of Particulate Matters Levels in Railway Cabins in Korea

  • Park, Duck-Shin;Kwon, Soon-Bark;Cho, Young-Min;Park, Eun-Young;Jeong, Woo-Tae;Lee, Ki-Young
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.1
    • /
    • pp.51-56
    • /
    • 2012
  • Objectives: High concentrations of airborne particulate matters (PM) can affect the health of passengers using public transportation. The objectives of this research were to develop a PM control system for a railway cabin and to evaluate the performance of the device under conditions of an actual journey. Methods: This study measured the concentrations of $PM_{10}$ and $PM_{2.5}$ simultaneously in a reference cabin and a cabin with the PM control device. Results: The average $PM_{10}$ concentration in the reference cabin was 100 ${\mu}g/m^3$, and the $PM_{10}$ concentration in the cabin with the control device was 79 ${\mu}g/m^3$. While the overall control efficiency of the control device was 15.4%, reduction was more effective for peak $PM_{10}$ concentration. However, $PM_{2.5}$ levels did not differ greatly between the reference cabin and the cabin with the control device. The ratio of $PM_{2.5}$ to $PM_{10}$ was 0.37. $PM_{10}$ concentrations in cabins were not associated with ambient concentrations, indicating that the main sources of $PM_{10}$ were present in cabins. Additionally, average $CO_2$ concentration in the cabins was 1,359 ppm, less than the maximum of 2,000 ppm set out by the Korean Ministry of Environment's guideline. The $CO_2$ concentration in cabins was significantly associated with the number of passengers: the in-cabin concentration = $23.4{\times}N+460.2$, where N is the number of passengers. Conclusions: Application of the PM control device can improve $PM_{10}$ concentration, especially at peak levels but not $PM_{2.5}$ concentration.

Development of a Low -Cost and Precise Liquid Metering Device for Automatic Nutrient-Solution Control (양액 자동조제용 액제 정밀계량 장치 개발)

  • 이정훈;류관희;이규철
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1997.12a
    • /
    • pp.255-262
    • /
    • 1997
  • A low-cost and precise metering device, which is suitable to automatic mixing of nutrient-solution for hydroponic culture, was developed for small-scale growers. The metering device was composed of three parts those were supply pumps, metering cylinders and venturi tube. Those parts were controlled by personal computer with time-based odoff control method. To verify the performance of the developed metering device, the relationship between operating time and discharge was examined and the accuracy of the developed metering device was compared with commercial metering pumps. The results of this study are as follows. 1. The correlation coefficient between the flow rate and operating time was 0.9999, and the linear regression equation computed was y=21.759x, where y is the discharge(g) and x is the operating time(s). 2. The developed device has greater accuracy than commercial metering pumps in terms of the full-scale error. Calculated errors for the developed metering device and two commercial pump were $\pm$0.3 %, $\pm$2.45 % and $\pm$1.38 % respectively. 3. Above results show developed metering device is a useful tool for nutrient-solution control system.

  • PDF

CFD Analysis of the Inertial Impaction Pre-Filter for a Particulate Matter Collecting Device (미세먼지 포집장치 개발을 위한 관성충돌 프리필터 유동 전산해석)

  • Kyung, Dae Seung;Hwang, Dae Sung
    • Land and Housing Review
    • /
    • v.10 no.2
    • /
    • pp.53-58
    • /
    • 2019
  • Particulate matter (PM) is designated as a group 1 carcinogen by the International Agency for Research on Cancer (IARC) of the World Health Organization (WHO). In South Korea, the health threat caused by PM is the most serious level internationally. Therefore, in order to solve the urban PM problem, it is important to develop the technology that can control PM efficiently. In this study, CFD(Computational Fluid Dynamics) simulation was performed for PM pre-filter (type 1-3 with different PM collecting room) to develop a high-efficiency PM collecting device. The complex flow field and the local flow phenomenon inside the PM collecting device were understood with CFD simulation by changing the shape and size of the pre-filter. The PM removal performance can be described with flow rate through the device and PM removal efficiency. The type-1 pre-filter with 5x5 size collecting room was confirmed to have the highest efficiency. Based on the analysis results, the optimal type of pre-filter could be developed and it would be applied as an element technology included in the PM collecting device.

Development of Automatic Nutrient-Solution Mixing System Using a Low-Cost and Precise Liquid Metering Device (액제 정밀계량 장치를 이용한 양액 자동조제 시스템 개발)

  • 이규철;류관희;이정훈;김기영;황호준
    • Journal of Biosystems Engineering
    • /
    • v.22 no.4
    • /
    • pp.469-478
    • /
    • 1997
  • This study was conducted to develop an automatic nutrient-solution mixing system for small-scale sewers. The nutrient-solution mixing system consisted of a low-cost and precise metering device and data acquisition & control system with a personal computer. and, the metering device was composed of three parts those were supply pumps, metering cylinders and venturi tube. The system controlled electric conductivity(EC) and pH of nutrient-solution based on the time-based feedback control method with the information about temperature, EC, and pH of the nutrient-solution. The performance of the nutrient-solution mixing system was evaluated through the control of EC and pH while compared with those of commercial system. Also an experimental cultivation of tomato was conducted to verify and to improve the developed system. Results of this study were as follows. 1. The correlation coefficient of meteing device between the flow rate and operating time was 0.9999, and the linear reuession equation computed was y=21.759x, where y is the discharge($g$) and x is the operating time(s). 2. Calculated errors for the developed metering device and two commercial pump were $\pm$0.3% $\pm$2.45% and $\pm$1.38 % FS error respectively. 3. An automatic nutrient-solution mixing system based on a low-cost and precise metering device was developed. 4. The full scale errors of the developed system in controlling EC and pH at 23$\pm$1$^{\circ}C$ were $\pm$0.05mS/cm and $\pm$0.2, respectively 5. When using the commercial system, the controlled values of EC and pH of the 500 $\ell$ of water were 1.29 mS/cm and 6.1 pH for the setting points of 1.4 mS/cm and 6.0 pH respectively at 23$pm1^{\circ}C$. 6. The developed nutrient-solution control system showed $\pm$0.05 ms/cm of deviation from the setting EC value over the experimental cultivation period. 7. The deviation from the average values of Ca and Mg mass content in the several nutrient-solution were 0.5% and 1.8% respectively.

  • PDF

Effect of Using Progesterone Releasing Intravaginal Device with Ovsynch Program on Reproduction in Dairy Cattle during Summer Season

  • Alnimer, M.;Lubbadeh, W.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.16 no.9
    • /
    • pp.1268-1273
    • /
    • 2003
  • Sixty postpartum lactating Friesian cows in 3 treatments at a commercial dairy farm were used to study the effect of using progesterone supplementation with GnRH and PGF2$\alpha$ synchronization with and without timed AI on fertility during summer. Cows in treatment1($Tr_1$) and treatment2 ($Tr_1$) were fitted with progesterone releasing intravaginal device (PRID) device and injected with 10 g GnRH agonist on $51{\pm}3$ d postpartum (pp). Seven days later, PRID was removed and cows received 25 mg PGF2$\alpha$. Two days later, $Tr_1$ cows received another injection of 10 g GnRH and timed AI 16-20 h later. Control cows received only 25 mg PGF2$\alpha$ $58{\pm}3d\;pp$. $Tr_2$ and control cows were AI at detected estrus. Serum progesterone for all cows was determined on days of injection, AI and 21, 23 and 28 d postinsemination. Pregnancy rates from first AI based on serum P4 concentrations on d 21, 23 and 28 postinsemination (50, 40 and 35%) and that based on rectal palpation 40-45 d postinsemination (30, 15 and 15% for $Tr_1$, $Tr_2$ and control cows, respectively) did not differ among the three groups. Whereas, pregnancy rate at 120 d pp for $Tr_1$ (65%) was higher (p<0.05) than that in $Tr_2$ (30%) or control (30%). The overall pregnancy rate was not significantly different (90, 90 and 75% for $Tr_1$, $Tr_2$ and control, respectively). Days open for cows in $Tr_1$ ($100.3{\pm}9$) was less (p<0.03) than that in $Tr_2$ ($130.9{\pm}9$) or control ($135.1{\pm}10$). Results indicate that using PRID device with Ovsynch program had significantly increased pregnancy rate and decreased days open compared to AI at detected estrus after synchronization with GnRH, PRID and PGF2$\alpha$ or synchronization with one injection of PGF2$\alpha$.

Assistant device development and effects for promotion of bag-valve-mask ventilation (백-밸브-마스크 환기증진을 위한 보조기구 개발 및 효과)

  • Kwon, Chan-Yang;Lee, In-Soo
    • The Korean Journal of Emergency Medical Services
    • /
    • v.22 no.1
    • /
    • pp.49-59
    • /
    • 2018
  • Purpose: The purpose of this study was to develop an assistant device for the promotion of bag-valve-mask ventilation based on a non-equivalent control group pre-test and post-test design. Methods: The experimental tool was a mask assistance device developed by the researchers. Data were analyzed using SPSS 21.0 with the cardiopulmonary resuscitation (CPR) evaluation program from August 18 to 30, 2016. The research tools included general, hand-related, and ventilation-related characteristics. Results: Before and after using the mask assistance device, the tidal volume increased by 64 mL (p<.001) from 461.76 mL to 525.86 mL. The tidal volume for control was 477.86 mL, and there was a statistical difference (p<.05). The ventilation frequency in device users was 10 times per minute for a total of 20 ventilations with before 10.65 after 10 times, and that of the control group was before 10.36 times after 10 times; there was no difference in both groups(p>.05). The accuracy of the assistance device was $81.72{\pm}30.86%$, which was a very high value. However, the accuracy of ventilation in the control group with no assistance device was $18.97{\pm}32.44%$, which was a very low accuracy rate. Conclusion: This study's results suggested utilizing the newly-developed mask assistance device in CPR, and showed increases in tidal volume and accuracy of ventilation using the bag-valve-mask ventilation equipment. The general and hand-related characteristics did not have any effect, so the use of the device proved to increase the efficacy in all users.

Development of Automatic Nutrient-Solution Control System Using a Low -Cost and Precise Liquid Metering Device (액제 정밀계량장치를 이용한 액제 자동조제 시스템개발)

  • 류관희;홍순호;이규철;이정훈;황호준
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1997.06c
    • /
    • pp.89-98
    • /
    • 1997
  • This study was conducted to develop an automatic nutrient-solution control system for small-scale growers. The nutrient-solution control system consisted of a low-cost and precise metering device and a personal computer. The system controlled electric conductivity(EC) and pH of nutrient-solution based on the time-based feedback control method with the information about temperature, EC, and pH of the nutrient-soIution. The performance of the nutrient-solution control system was evaluated through the control of EC and pH while compared with those of commercial nutrient-solution control system. Also an experimental cultivation of tomato was conducted to verify and to improve the developed system. Results of this study were as follows. 1. An automatic nutrient-solution control system based on a low-cost and precise metering device was developed. 2. The developed system controlled EC and pH within $\pm$0.05 mS/cm and $\pm$0.2 pH full scale error respectively at $24^{/circ}C$. 3. When using the commercial system, the controlled values of EC and pH of the 500l of water were 1.29 mS/cm and 6.1 pH for the setting points of 1.4 mS/cm and 6.0 pH respectively at $22^{/circ}C$. 4. The developed nutrient-solution control system showed $\pm$0.05 mS/cm of deviation from the setting EC value over the experimental cultivation period. 5. The deviation from the average values of Ca and Mg mass content in the several nutrient-solution were 0.5% and 1.8% respectively.

  • PDF

Height Measurement of Cellphone Curved Glass using Camera (카메라를 이용한 휴대폰 곡면유리의 높이측정)

  • Kim, Han-Sol;Lee, Kyung-Jun;Jung, Dong-Yean;Lee, Yeon-Hyeong;Kim, Gab-Soon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.12
    • /
    • pp.1002-1010
    • /
    • 2016
  • This paper describes the design of a cellphone curved glass measuring device using by camera. The measuring device was composed of two camera, two backlight system, a body and so on, and the program was made for a camera calibration and noise removal, and also the program was made for height measurement of a cellphone curved glass using by subpixel algorism. And then a new technique for measuring the height of the cell phone curved glass was proposed. The characteristics test of height measurement of gage blocks and cell phone curved glasses was carried out, the error of the height measurement of gage block is less than ${\pm}0.005$ and the error of the height measurement of the cell phone curved glasses is less than ${\pm}0.005$. Thus it thought that the designed cellphone curved glass measuring device and the new technique for measuring the height was used to measure the height of the cellphone curved glass.

Effect of embossed new dental pick on periodontitis (Embossed new dental pick이 치주염에 미치는 영향)

  • Suk, Hun-Joo;Kim, Chong-Kwan
    • Journal of Periodontal and Implant Science
    • /
    • v.34 no.3
    • /
    • pp.563-572
    • /
    • 2004
  • Since bacterial plaque is known as the major cause of every oral disease, it is necessary to control plaque to maintain periodontal health. Although tooth brushing has been the typical method of plaque control, additional use of plaque control devices are necessary for cleansing interdental areas. Dental floss has been used for a long time as the additional plaque control device and proved to be effective. The newly developed embossed new dental pick is composed of elastic plastic material in form with its tip longer than other toothpick. In addition, as thickness of the tip gradually increases, it can be adapted easily with minimal trauma to interdental gingiva. The embossed tip can remove dental plaque easily, and the opposite end can approach lingual and palatal areas through triple angulation. Therefore, the authors studied the effect of embossed new dental pick and dental floss on periodontally involved 15 patient. The following results were obtained. 1. For embossed new dental pick, probing depth at baseline, 1 week, 4 weeks were $3.6{\pm}0.6mm$, $3.4{\pm}0.5mm$, $3.2{\pm}0.5mm$, respectively, and $4.2{\pm}0.9mm$, $4.1{\pm}0.9mm$, $4.0{\pm}0.9mm$, respectivly for clinical attachment level. 2. In case of embossed new dental pick, bleeding on probing at baseline, 1 week, 4 weeks were $43.0{\pm}4.4%$, $28.5{\pm}5.1%$, $22.2{\pm}5.6%$, respectively, and, at 1 week and 4 weeks, they were significantly different from that of dental floss. 3. Gingival index of toαhpick at baseline, 1 week, 4 weeks were $1.7{\pm}0.5$, $1.0{\pm}0.3$, $0.9{\pm}0.2$, respectively, and, $1.7{\pm}0.5$, $1.1{\pm}0.4$, $1.0{\pm}0.4$, respectively for plaque index, and $3.0{\pm}0.5$, $1.7{\pm}0.5$, $1.4{\pm}0.4$, respectively for proximal plaque index. proximal plaque index at 4 weeks was significantly different from that of dental floss. 4. The result of questionnaire showed that the two types of device were both satisfactory, however, embossed new dental pick had higher preference as well as satisfaction. As a result, embossed new dental pick is thought to be clinically effective for its simplicity and good accessibility.