• Title/Summary/Keyword: contrast medium injection

Search Result 64, Processing Time 0.025 seconds

Evaluation of the Solitary Pulmonary Nodule by Spiral Computed Topography with Contrast Enhancement (고립성 폐결절의 감별에 있어서 나선형 흉부 전산화 단층촬영시 조영증강의 의의)

  • Song, Kwang Seon;Shin, Kye Chul;Yong, Suk Joong;Ryu, Jeong Seon;Kang, Sin Goo;Kim, Chong Ju;Sung, Ki Joon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.4
    • /
    • pp.519-526
    • /
    • 1996
  • Background : Clinical and Radiographic studies to differentiate benign from malignant pulmonary nodules have previously focused on clinical status and the morphologic and the computed tomographic attenuation characteristics of the lung nodules. Distinctive differences in the vascularity and pathophysiology of malignant versus benign pulmonary nodules were identified. We evaluated the diagnostic method for differentiating malignant from benign solitary pulmonary nodule by contrast enhancement on the spiral CT. Method : Sixteen patients with solitary pulmonary nodule were examined(Tuberculoma 8, primary lung cancer 8). Serial thin section on the spiral CT was performed before and after(45second, 2min, 5min) the onset of the injection of 100mL of nonionic contrast material(2mL/sec). Results : There was no difference in size of nodule and pre-contrast CT number (Hounsfield unit) between benign and malignant nodules. At forty-five second after the onset of the injection, malignant neoplasms($19.6{\pm}7.9$ HU) enhanced significantly more than tuberculomas($4.9{\pm}9.4$ HU, p=0.008). At 2minute and 5 minute after, malignant neoplasms($34.0{\pm}19.2$HU, $34.0{\pm}15.4$HU) enhanced significantly more than tuberculomas ($6.7{\pm}9.7$HU, p=0.007 and $7.7{\pm}11.5$HU, p=0.011). On cut-off value 20HU(contrast enhancement) 2minute after the injection of contrast media, sensitivity was 87% and specificity was 87%. No correlation between the contrast enhancement and size of the nodules was observed. Conclusion : Studies with the use of an intravenously administered noniodinated contrast medium in examining the enhancement properties of lung nodules was performed. The contrast enhancement was useful in differential diagnosis of solitary pulmonary nodules.

  • PDF

THE DYNAMICS OF STELLAR WINDS: THEIR STRUCTURES AND [OIII] LINE FORMATION

  • CHA SEUNG-HOON;LEE YOUNG-JIN;CHOE SEUNG-URN
    • Journal of The Korean Astronomical Society
    • /
    • v.29 no.spc1
    • /
    • pp.253-254
    • /
    • 1996
  • To understand the dynamical structures of stellar wind bubble, one and two-dimensional calculations has been performed. Using FCT Code with cooling effects and assuming constant mass loss rate and ambient medium density, we could divide stellar winds into the regime of slow and fast winds. The slow wind driven bubble shows initially radiative and becomes partially radiative bubble in which shocked stellar wind zone is still adiabatic. In contrast., the fast wind driven bubble shows initially fully adiabatic and becomes adiabatic bubbles with radiative outer shell. We also determine analytically the onset of thin-shell formation time in case of fast wind driven bubble with power-law energy injection and ambient density structure. We solve the line transfer problem with numerical results in order to calculate line profile of [OIII] forbidden line.

  • PDF

Power Doppler ultrasound-guided sialography using the phenomenon of increased blood flow: A technical report

  • Oh, Song Hee;Seo, Yu-Kyeong;Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.49 no.4
    • /
    • pp.301-306
    • /
    • 2019
  • Purpose: This report presents a procedure for performing power Doppler ultrasound-guided sialography using the phenomenon of increased blood flow and illustrates its application to practical patient cases. Materials and Methods: The salivary gland was scanned using ultrasound equipment (GE LOGIQ5 Expert® device; GE Medical Systems, Milwaukee, WI, USA) to identify pathological findings related to the patient's chief complaint. To identify the orifice of the main duct, it should be cannulated using a lacrimal dilator. After inserting the catheter into the cannulated main duct, the position of the catheter within the duct was confirmed by ultrasound. A contrast agent was injected until the patient felt fullness, and ultrasound (B-mode) was used to confirm whether the contrast agent filled the main canal and secondary and tertiary ducts. Then, power Doppler ultrasound was performed to determine whether the salivary gland had increased blood flow. Results: In 2 cases in this report, a power Doppler ultrasound scan showed a significant increase in blood flow after contrast medium injection, which was not observed on a preoperative scan. Conclusion: Power Doppler ultrasound was found to be a simple, safe, and effective tool for real-time sialography monitoring.

Radiological Perspectives for Diagnosis of Vasospastic Angina with Coronary Angiography (이형성 협심증 진단 조영 검사의 방사선학적 관점)

  • Jong-Gil Kwak;Young-Hyun Seo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.589-595
    • /
    • 2023
  • If complete coronary artery occlusion occurs due to severer coronary spasm, malignant arrhythmias can lead to death. Therefore, early screening for coronary artery spasm angina is essential. Among the test methods, the drug injection test through coronary angiography is generally performed. Therefore, the purpose of this study was to evaluate the advantages of ergonovine drug test for vasospasitc angina examination during coronary angiography, such as the relationship between the procedure time, contrast medium usage, and radiation exposure effects of coronary angiography. Follow-up data of 142 patients who underwent coronary angiography and variant angina examination from september 2021 to february 2023 were used. As a result of analyzing contrast usage dose and dose area product and air kerma dose and number of imaging series and procedure time, variant angina examination was statistically significantly higher than coronary angiography. (p<0.001) In conclusion, variant angina examination other than coronary artery angiography are radiologically negative. Therefore, we think it is better to avoid excessive inspection. Nevertheless, in the case of the provocation test, the longer the examination time, the higher the fluoroscopy time and the amount of contrast medium used, so it is better to conduct the test as quickly as possible or shorten it.

Should Cerebral Angiography Be Avoided within Three Hours after Subarachnoid Hemorrhage?

  • An, Hong;Park, Jaechan;Kang, Dong-Hun;Son, Wonsoo;Lee, Young-Sup;Kwak, Youngseok;Ohk, Boram
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.5
    • /
    • pp.526-535
    • /
    • 2019
  • Objective : While the risk of aneurysmal rebleeding induced by catheter cerebral angiography is a serious concern and can delay angiography for a few hours after a subarachnoid hemorrhage (SAH), current angiographic technology and techniques have been much improved. Therefore, this study investigated the risk of aneurysmal rebleeding when using a recent angiographic technique immediately after SAH. Methods : Patients with acute SAH underwent immediate catheter angiography on admission. A four-vessel examination was conducted using a biplane digital subtraction angiography (DSA) system that applied a low injection rate and small volume of a diluted contrast, along with appropriate control of hypertension. Intra-angiographic aneurysmal rebleeding was diagnosed in cases of extravasation of the contrast medium during angiography or increased intracranial bleeding evident in flat-panel detector computed tomography scans. Results : In-hospital recurrent hemorrhages before definitive treatment to obliterate the ruptured aneurysm occurred in 11 of 266 patients (4.1%). Following a univariate analysis, a multivariate analysis using a logistic regression analysis revealed that modified Fisher grade 4 was a statistically significant risk factor for an in-hospital recurrent hemorrhage (p=0.032). Cerebral angiography after SAH was performed on 88 patients ${\leq}3$ hours, 74 patients between 3-6 hours, and 104 patients >6 hours. None of the time intervals showed any cases of intra-angiographic rebleeding. Moreover, even though the DSA ${\leq}3$ hours group included more patients with a poor clinical grade and modified Fisher grade 4, no case of aneurysmal rebleeding occurred during erebral angiography. Conclusion : Despite the high risk of aneurysmal rebleeding within a few hours after SAH, emergency cerebral angiography after SAH can be acceptable without increasing the risk of intra-angiographic rebleeding when using current angiographic techniques and equipment.

Extracting Blood Vessels through Similarity Analysis and Intensity Correction (유사도 분석과 명암 보정을 통한 혈관 추출)

  • Jang Seok-Woo
    • Journal of Internet Computing and Services
    • /
    • v.7 no.4
    • /
    • pp.33-43
    • /
    • 2006
  • This paper proposes a method to extract coronary arteries effectively in the angiography, In general. DSA(Digital Subtraction Angiography) is a well-established technique for the visualization of coronary arteries, DSA involves the subtraction of a mask image, an image of a heart before the injection of contrast medium, from a live image, However, this technique is sensitive to the movement of background and can cause wrong detection due to the variance of background intensity between two images. Therefore, this paper solves the structural problem resulted from background movement by selecting an image which has the least difference of movement through the similarity analysis of background texture, and it extracts only the blood vessels effectively through local intensity correction of the selected images, Experimental results show that the proposed method has the lower false-detection rate and higher accuracy rate than existing methods.

  • PDF

Paraplegia Following Celiac Plexus Block -A case report- (복강신경총 차단후 하지마비 -증례 보고-)

  • Na, Ae-Ja;Moon, Dong-Eon;Suh, Jae-Hyun
    • The Korean Journal of Pain
    • /
    • v.6 no.1
    • /
    • pp.129-132
    • /
    • 1993
  • Paraplegia complicating a block of the celiac plexus with alcohol for recurrent stomach cancer is described. A 33 year old male patient was admitted to control for severe epigastric pain. With the patient in prone position, the needle was advanced further than 2 cm on the anterior margin of $L_1$ vertebral body under fluoroscopy. 3 ml of 1% lidocaine and 5 ml of conray were injected through each needle, and the diffusion of the contrast medium was checked, This was followed by 7 ml of pure alcohol and 8 ml of 50% alcohol for each needle. At that time, the patient was very satisfied with loss of abdominal pain. About 30 minutes after injection of alcohol, suddenly patient complained of severe burning pain on back and both extremities. Thereafter, loss of sensation and paralysis in both extremities were developed slowly. The senstivity to cold recovered 3 days after block. By the 33rd day after the block, sensation had recovered in both extremities, the bladder and rectum. Movement of the right ankle joint and left great toe was also possible.

  • PDF

주사용 요오드화 조영제 및 MRI용 가돌리늄 조영제 유해 반응에 대한 한국 임상진료지침: 개정된 임상적 합의 및 권고안(2022년 제3판)

  • Se Won Oh;So Young Park;Hwan Seok Yong;Young Hun Choi;Min Jae Cha;Tae Bum Kim;Ji Hyang Lee;Sae Hoon Kim;Jae Hyun Lee;Gyu Young Hur;Jae Yeon Hwang;Sejoong Kim;Hyo Sang Kim;Ji Young Ryu;Miyoung Choi;Chi-Hoon Choi
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.2
    • /
    • pp.254-264
    • /
    • 2022
  • The Korean Society of Radiology and Medical Guidelines Committee amended the existing 2016 guidelines to publish the "Korean Clinical Practice Guidelines for Adverse Reactions to Iodide Contrast for Injection and Gadolinium Contrast for MRI: The Revised Clinical Consensus and Recommendations (2022 Third Edition)." Expert members recommended and approved by the Korean Society of Radiology, the Korean Academy of Asthma, Allergy and Clinical Immunology, and the Korean Nephrology Society participated together. According to the expert consensus or systematic literature review, the description of the autoinjector and connection line for the infection control while using contrast medium, the acute adverse reaction, and renal toxicity to iodized contrast medium were modified and added. We would like to introduce the revised contents.

Comparison of Image Quality in Magnetic Resonance Imaging of the Abdominal Organ at 1.5T and 3.0T before the Gadolinium Injection (조영제 주입 전 1.5T 와 3.0T를 이용한 복부장기 자기공명영상에서 영상의 질 비교)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.619-625
    • /
    • 2017
  • The sudy was intended to evaluate the optimal equipment selection by quantitatively assessing the SNR(signal to noise ratio) and CNR(contrast to noise ratio) on the abdominal organ. This study performed on 1.5 T and 3.0 T MRI units focusing on HASTE, HASTE(f/s) and FFE(in of phase), FFE(out of phase) without using the contrast medium(Gadolinium). The data analysis was performed by randomly selecting on 1.5 T and 3.0 T abdominal MRI images. As a results, SNR and CNR values of 3.0 T is higher than 1.5 T at liver, kidney and spleen(p<0.05). Stomach, abdominal fat and pancreas was obtained a higher value at 1.5 T(p<0.05). On conclusion, the organs of outer part in the body showed generally a high value at 3.0 T, and the organs of inner part in the body including the gas showed a high value at 3.0 T because of a large difference on magnetic susceptibility.

An Experimental Study for the Prevention of CT Contrast Media Extravasation with Extravasation Detection Accessory System in Femoral Vein of Rabbit (가토 정맥에서 CT 조영제의 혈관외유출 예방을 위한 EDA 시스템의 실험적 연구)

  • Kweon, Dae-Cheol;Jeong, Seok-Hee;Yang, Sung-Hwan;Cho, Mun-Son;Jang, Keun-Jo;Kim, Sun-Geun;Yoo, Beong-Gyu;Lee, Jong-Seok
    • Progress in Medical Physics
    • /
    • v.17 no.4
    • /
    • pp.238-245
    • /
    • 2006
  • To assess the ability of an extravasation defection accessory (EDA) to detect the clinically important extravascular Injection of iodinated contrast material that was delivered with an automated mechanical power injector. The purpose of this study was to assess the ability of this device during clinically important episodes of extravasation. The EDA system was composed of a strain gage, an amplifier and a computer-based system. In the rabbit experimental cases, there were seven true-positive cases (range of the extravasation volumes: $14{\sim}23 ml$). The algorithm results showed seven true-positive cases (range of the extravasation volumes: $7{\sim}16ml$), nineteen true-negative cases, two false-positive cases and no false-negative cases. The EDA system had a sensitivity of 100% and a specificity of 90% for the detection of clinically important extravasation. The EDA system had good sensitivity for the detection of clinically important extravasation and the EDA system has the clinical potential for the early detection of extravasation of the contrast medium that is administered with power injectors.

  • PDF