• Title/Summary/Keyword: contrast analysis

Search Result 3,335, Processing Time 0.038 seconds

A Simulation Study on the Transfer Characteristics of the Talbot Pattern Through Scintillation Screens in the Grating Interferometer (격자 간섭계에서 탈봇 패턴의 섬광체 스크린 투과 시 전달 특성에 대한 시뮬레이션 연구)

  • Kim, Daeseung;Kim, Youngju;Lee, Seho;Lee, Seung Wook
    • Journal of radiological science and technology
    • /
    • v.42 no.1
    • /
    • pp.67-75
    • /
    • 2019
  • Grating interferometry based imaging technology is a kind of radiation imaging system, which can acquire not only absorption image but also phase difference and dark field image using the Talbot pattern. However, because of the technological difficulties and high cost of fabricating the gratings that make up the system, much efforts are being made to look for ways to replace them. The is a preliminary study to see how the Talbot pattern transfer through various kinds of scintillators and if the optical grating can be a way to replace the conventional absorption gratings. The geometry of the interferometer, the scintillator model, and the scintillator thickness are the main inputs for our simulation. We have used the concept of modulation for quantitative analysis of the contrast ratio of the Talbot pattern. This research is expected to provide very useful information on the design of optical gratings, which is an alternative way to analyze the Talbot pattern, which we have filed a patent on.

Morphometric Analysis of the Ureter with Respect to Lateral Lumbar Interbody Fusion Using Contrast-Enhanced Computed Tomography

  • Chunneng Huang;Zhenyu Bian;Liulong Zhu
    • Journal of Korean Neurosurgical Society
    • /
    • v.66 no.2
    • /
    • pp.155-161
    • /
    • 2023
  • Objective : To analyze the anatomical location of the ureter in relation to lateral lumbar interbody fusion and evaluate the potential risk of ureteral injury. Methods : One hundred eight patients who performed contrast-enhanced computed tomographic scans were enrolled in this study. The location of the ureter from L2-L3 to L4-L5 was evaluated. The distances between the ureter and psoas muscle, intervertebral disc, and retroperitoneal vessels were also recorded bilaterally. Results : Over 30% of the ureters were close to the working corridor of extreme lumbar interbody fusion at L2-L3. Most of the ureters were close to working corridor of oblique lumbar interbody fusion, especially at L4-L5. The distance from the ureter to the great vessels on the left side was significantly narrowing from L2-L3 to L4-L5 (28.8±9.5 mm, 22.0±8.0 mm, 15.5±8.4 mm), and it was significantly larger than that on the right side (12.3±6.1 mm, 7.4±5.7 mm, 5.4±4.4 mm). Conclusion : Our findings indicate that the location of the ureter varies widely among individuals. To avoid unexpected damage to the ureter, it is imperative to directly visualize it and verify the ureter is not in the surgical pathway during lateral lumbar interbody fusion.

The Guideline for Colorectal Cancer Screening (대장암 선별검사 권고안)

  • Dong Il Park
    • Journal of Digestive Cancer Research
    • /
    • v.4 no.1
    • /
    • pp.17-20
    • /
    • 2016
  • Colorectal cancer is the 2nd most common cancer in men, and the 3rd most common cancer in women in Korea. This incidence has been increasing steadily since the data analysis began in 1999. Guidelines from many countries including Korea recommend annual or biennial fecal occult blood test as a national colorectal cancer screening program, however, colonoscopy, stool DNA test, double contrast barium enema, and sigmoidoscopy are recommended in some countries. I will summarize the Korean National Screening Guideline for colorectal cancer revised by multi-society expert committee in Korea last year. They recommend annual or biennial fecal immunochemical test between 45 and 80 year-old asymptomatic average risk people. Selective use of colonoscopy is recommended, taking into consideration of individual preference and the risk of colorectal cancer. There is no evidence for the risks or benefits of double contrast barium enema or computed tomographic colonography for colorectal cancer screening.

  • PDF

MR Imaging of Congenital Heart Diseases in Adolescents and Adults

  • Yeon Hyeon Choe;I-Seok Kang;Seung Woo Park;Heung Jae Lee
    • Korean Journal of Radiology
    • /
    • v.2 no.3
    • /
    • pp.121-131
    • /
    • 2001
  • Echocardiography and catheterization angiography suffer certain limitations in the evaluation of congenital heart diseases in adults, though these are overcome by MRI, in which a wide field-of view, unlimited multiplanar imaging capability and three-dimensional contrast-enhanced MR angiography techniques are used. In adults, recently introduced fast imaging techniques provide cardiac MR images of sufficient quality and with less artifacts. Ventricular volume, ejection fraction, and vascular flow measurements, including pressure gradients and pulmonary-to-systemic flow ratio, can be calculated or obtained using fast cine MRI, phase-contrast MR flow-velocity mapping, and semiautomatic analysis software. MRI is superior to echocardiography in diagnosing partial anomalous pulmonary venous connection, unroofed coronary sinus, anomalies of the pulmonary arteries, aorta and systemic veins, complex heart diseases, and postsurgical sequelae. Biventricular function is reliably evaluated with cine MRI after repair of tetralogy of Fallot, and Senning's and Mustard's operations. MRI has an important and growing role in the morphologic and functional assessment of congenital heart diseases in adolescents and adults.

  • PDF

The Promotions of Brands and Stores and their Impact the Optimal Decisions for the Marketing Channel Members (두 종류의 촉진(브랜드 프로모션과 점포 프로모션)과 유통구성원의 최적결정)

  • 김상용
    • Journal of Distribution Research
    • /
    • v.3 no.1
    • /
    • pp.7-29
    • /
    • 1998
  • Manufacturers want brand promotions at the stores. In contrast, retailers want promotions for the stores rather than for the brands since better store promotions can attract customers from the competing retail stores. In this paper, three scenarios are assumed for the promotions in terms of the allowances or the side-payments form the manufacturer to the retailer and the pass-through rate for the allowances being used for the brand promotions by the retailer. An analytical model for the marketing channel distribution is used for the analysis. Then, several marketing implications are suggested based on the findings.

  • PDF

The Complete Analysis of Rotational Dynamics of Paramagnetic Contrast Agents

  • 황문정;장용민;강덕식
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.117-117
    • /
    • 2001
  • 목적: 상자성 자기공명 조영제의 효율을 결정하는 중요 인자중의 하나인 조영제의 rotational correlation time ($\tau$R)을 전자상자성공명 data를 측정하고 이를 정량적으로 분석하여 결정하였다. 대상 및 방법: rotational dynamics가 주로 분자의 크기 및 모양에 의해 결정된다는 점을 이용하여 anisotropic한 (equation omitted) tensor를 가지는 VO$^{2+}$의 VO(DTPA)시료에 대해 다양한 온도에서 즉 다양한 rotational time에 대해 ESR spectrum을 측정하였다. 측정된 EPR data로부터 (equation omitted) 텐서 그리고 최종적으로 $\tau$R 을 SIMPOW와 EPRLF을 사용하여 계산하였다.

  • PDF

Optical-Electronic Method for Statistical Evaluation of Human Corneal Endothelial Patterns (Human Corneal Endothelial 패턴의 통계적 분석을 위한 광전자적 방법)

  • Lee, Yim-Kul
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.11
    • /
    • pp.58-62
    • /
    • 1992
  • Hybrid optical-electronic procedures are introduced for the automated estimation of cell parameters (e.g., size, size variation, and shape). Two different optical Fourier analysis procedures are applied to high contrast cell boundary patterns obtained from specular micrographs of the endothelial layer. In one case, a large number of cell patterns are illuminated to extract average cell size information. Once the average cell size information has been obtained, individual cells are illuminated to extract shape information.

  • PDF

Analysis of Structure Model for Repeated Measurement Design and Hierarchical Design (반복측정 설계와 계층적 실험설계의 구조모형)

  • Choi, Sung-Woon
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2011.04a
    • /
    • pp.95-99
    • /
    • 2011
  • The research analyzes structure models of Repeated Measurement Design (RMD) and Hierarchical Design (HD). The experimental unit of RMD model is living organisms, such as human. In contrast, HD is used when all the factors are random. The HD models are derived from R:B:A, R:C:B:A and R:C:($A{\times}B$).

  • PDF

Predicting traffic accidents in Korea (국내 교통사고 예측)

  • Yang, Hee-Joong
    • Journal of the Korea Safety Management & Science
    • /
    • v.13 no.1
    • /
    • pp.91-98
    • /
    • 2011
  • We develop a model to predict traffic accidents in Korea. In contrast to the classical approach that mainly uses regression analysis, Bayesian approach is adopted. A dependent model that incorporates the data from different kinds of accidents is introduced. The rate of severe accident can be updated even with no data of the same kind. The data of minor accident that can be obtained frequently is efficiently used to predict the severe accident.