  • A study on the infrared signature of a naval ship by the solar elevation was performed using the well known IR signature analysis software, ShipIR/NTCS. The contrast radiant intensity of a ship against the Eastern Sea background from sunrise to noon was investigated. Monthly averaged climate data for both January and July were applied to investigate the seasonal change in the signature. A study on the signature for different ship speeds was also carried out. Simulation results showed that the maximum signature in both wave-bands for a sea-level observer occurred at around 25~35 degrees of solar elevation and was highly dependent on the ship geometry rather than the solar irradiance.

The optical analysis of Te-based ART structure for the optical recording media (광기록 매질로 이용되는 Te계 ART구조의 광학적 해석)

  • 이성준;박태성;정홍배
    • Electrical & Electronic Materials
    • /
    • v.7 no.3
    • /
    • pp.220-224
    • /
    • 1994
  • In this study, we discussed the optical property to find the optimal condition of Te-based antireflection trilayer(ART) structure for a high density optical recording. It was found that the optical property was improved by suggesting the environmental parameters satisfied the optimum condition. As the results, the optimized(.lambda.=8.000${\AA}$.) thickness of the recording layer is 27${\AA}$, and the 1st and 2nd minimum ART conditions of dielectric layers are 1080${\AA}$, 3820${\AA}$, respectively. And the high SNR, the contrast ratio and the sensitivity are achieved by using the ART conditions.

  • PDF

Pareto Analysis of Experimental Data by L18(2 X 37) Orthogonal Array (L18(2 X 37) 직교배열표 실험자료에 대한 파레토 그림 분석)

  • 임용빈
    • The Korean Journal of Applied Statistics
    • /
    • v.17 no.3
    • /
    • pp.499-505
    • /
    • 2004
  • The Pareto diagram analysis of the experimental data by the two level orthogonal arrays has been used widely in practice since it is a graphical, quick and easy method to analyze experimental results, which does not use the analysis of variance to screen significant effects. For the analysis of the experimental data by $L_{18}(2 \times 3^7)$ orthogonal array, Park(1996) proposed Pareto ANOVA in which the size of effects is defined by the mean squares of effects and the Pareto principle is used. In this paper, a new approach of the Pareto diagram analysis of the experimental data by $L_{18}(2 \times 3^7)$ orthogonal array is proposed. The main idea is to partition the size of three level effects by that of linear and quadratic orthogonal contrasts of those effects.

Texture analysis in cone-beam computed tomographic images of medication-related osteonecrosis of the jaw

  • Polyane Mazucatto Queiroz;Karolina Castilho Fardim;Andre Luiz Ferreira Costa;Ricardo Alves Matheus;Sergio Lucio Pereira Castro Lopes
    • Imaging Science in Dentistry
    • /
    • v.53 no.2
    • /
    • pp.109-115
    • /
    • 2023
  • Purpose: The aim of this study was to evaluate changes in the trabecular bone through texture analysis and compare the texture analysis characteristics of different areas in patients with medication-related osteonecrosis of the jaw (MRONJ). Materials and Methods: Cone-beam computed tomographic images of 16 patients diagnosed with MRONJ were used. In sagittal images, 3 regions were chosen: active osteonecrosis(AO); intermediate tissue (IT), which presented a zone of apparently healthy tissue adjacent to the AO area; and healthy bone tissue (HT) (control area). Texture analysis was performed evaluating 7 parameters: secondary angular momentum, contrast, correlation, sum of squares, inverse moment of difference, sum of entropies, and entropy. Data were analyzed using the Kruskal-Wallis test with a significance level of 5%. Results: Comparing the areas of AO, IT, and HT, significant differences (P<0.05) were observed. The IT and AO area images showed higher values for parameters such as contrast, entropy, and secondary angular momentum than the HT area, indicating greater disorder in these tissues. Conclusion: Through texture analysis, changes in the bone pattern could be observed in areas of osteonecrosis. The texture analysis demonstrated that areas visually identified and classified as IT still had necrotic tissue, thereby increasing the accuracy of delimiting the real extension of MRONJ.

Study on Effectiveness of Ocean Meteorological Variables through Sensitivity Analysis of Ship Infrared Signature (함정 적외선신호 민감도 해석을 통한 기상변수 영향에 관한 연구)

  • Cho, Yong-Jin;Jung, Ho-Seok
    • Journal of Ocean Engineering and Technology
    • /
    • v.27 no.3
    • /
    • pp.36-42
    • /
    • 2013
  • According to a study on improving ship survivability, an IR signature represents the contrast radiance intensity between the radiation signature from a ship and the background signature. It was found from applying stealth techniques to the process of ship development that the IR signature is remarkably sensitive and dependent on the environment. In this study, marine climate data for the sea near the Korean Peninsula were collected, and the marine meteorological environment in Korean waters was defined. Based on this data, a study on the sensitivity of the IR signature of target objects was performed using analytical methods. The results of the research indicated that clouds have important effects on the infrared signature, but the velocity of the wind and the humidity have only slight effects on the IR signature. In addition, the air and seawater temperatures had hardly any effect on the IR signature, but it is judged that additional study is needed.

Phase Imaging of Worn Surface of TiN Coating and Interpretation by Force Spectroscopy

  • Hyo Sok;Chizhik, S-A;I Luzinov
    • KSTLE International Journal
    • /
    • v.1 no.2
    • /
    • pp.69-75
    • /
    • 2000
  • The paper compares topography, phase contrast and force spectroscopy in atomic force microscopy data for evaluating the microheterogeneity of surface layer. The worn surface of ion-plated TiN coating was measured using both a laboratory-built and a commercial AFM. The results of analysis revealed structural and micromechanical heterogeneity of the worn surfaces. We demonstrated that the phase image allows relatively qualitative estimation of elastic modulus of the sample surface. The tribolayer formed in the worn surface possessed much lower stiffness than the original coating. It is shown that the most stable phase imaging is provided with a stiff cantilever. In this case, phase contrast is well conditioned, first of all, by microheterogeneity of elastic properties of the investigated surfaces. In this study an attempt was also made to correlate the results of phase imaging with that of the farce spectroscopy. The joint analysis of information on the surface properties obtained by the phase imaging and quantitative data measured with the force spectroscopy methods allows a better understanding of the nature of the surface micromechanical heterogeneity.

  • PDF

Image Analysis of Black Female Fashion Models (흑인 여성 패션모델의 이미지 분석)

  • Rhew, Soo-Hyeon;Kim, Min-Ja
    • Journal of the Korean Society of Costume
    • /
    • v.59 no.2
    • /
    • pp.87-100
    • /
    • 2009
  • This study examines black images as 'the other' in history and aims to analyze images of black female fashion models which have been changed in modern society, particularly in $21^{st}$ century post-modern world. Black images, established historically as illustrated on the paintings in $19^{th}$ century, were disseminated in $20^{th}$ century throughout the world especially by way of TV and movies as several typical images such as 'Coon' the clown as the object of entertainment, 'Buck' wild and resistant black rascal, and 'Mammy' obedient and fat black woman servant. The result of image analysis of black female fashion models, can be summarized as following five images. The first is the image of 'powerful'. Black female models frequently represent healthy image which reflects black people's excellence in sports and also the traditional Image of black skin color as strength. The second is the image of 'sexy'. They are adored as having perfect ideal body shape. They show off their sex appeal with their body. The third image is 'multicultural'. Black models represent cultures besides the western. The fourth is the image of 'fantastic'. In contrast to the real, resonable things, black female models represent wild, fancy, ghost things. The fifth is the image of 'racial discrimination' By arranging them in contrast to whites, a metaphoric image of racial discrimination can be displayed. The result shows that tome of racial images still remain on the other way.

Improved Perfusion Contrast and Reliability in MR Perfusion Images Using A Novel Arterial Spin Labeling

  • Jahng, Geon-Ho;Xioaping Zhu;Gerald Matson;Weiner, Michael-W;Norbert Schuff
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.341-344
    • /
    • 2002
  • Neurodegenerative disorders, like Alzheimer's disease, are often accompanied by reduced brain perfusion (cerebral blood flow). Using the intrinsic magnetic properties of water, arterial spin labeling magnetic resonance imaging (ASLMRI) can map brain perfusion without injection of radioactive tracers or contrast agents. However, accuracy in measuring perfusion with ASL-MRI can be limited because of contributions to the signal from stationary spins and because of signal modulations due to transient magnetic field effects. The goal was to optimize ASL-MRI for perfusion measurements in the aging human brain, including brains with Alzheimer's disease. A new ASL-MRI sequence was designed and evaluated on phantom and humans. Image texture analysis was performed to test quantitatively improvements. Compared to other ASL-MRI methods, the newly designed sequence provided improved signal to noise ratio improved signal uniformity across slices, and thus, increased measurement reliability. This new ASL-MRI sequence should therefore provide improved measurements of regional changes of brain perfusion in normal aging and neurodegenerative disorders.

  • PDF

A Novel Multi-Channel Hearing Aid Algorithm with SMR(signal-to-masking ratio) Improvement (신호 대 마스킹 비 개선을 통한 다채널 보청 알고리즘)

  • 김헌중;홍민철;차형태
    • The Journal of the Acoustical Society of Korea
    • /
    • v.19 no.8
    • /
    • pp.12-21
    • /
    • 2000
  • In this paper, we propose a novel hearing aid algorithm for sensorinural hearing loss restoration with multi-channel(band) dynamic range compression and psychoacoustics. In this way, we can present a normal perception condition to the impaired listener. The proposed algorithm make loudness scaling function achieve proper loudness level, and analysis masking property for the signal will be perceived to impaired listener, and then, restore normal spectral contrast using SMR(signal-to-masking ratio) defined by distance between the level of each frequency and masking threshold.

  • PDF

AN EXPERIMENTAL STUDY ON THE TOOTH ROOT RESORPTION FOR DIGITAL RADIOGRAPHY (디지털 방사선 촬영술을 이용한 치근 흡수 판독에 관한 실험적 연구)

  • Oh Phill-Gyo;Kim Jae-Duk
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.25 no.2
    • /
    • pp.375-387
    • /
    • 1995
  • The purpose of this study was to quantitatively evaluated experimental tooth root resorption for digital radiography. For this study, experimentally three root sites were used, and radiograms were taken with standardized apparatus. Digital imaging system were consisted of NEC PC-980l(computer), TRINITRON(monitor), SONY XC-711 CCD camera. The display monitor had a resolution of 512X512 pixels. The obtained results were as follows: 1. In the difference of the four X-ray film of the contrast correction, the contrast difference was one gray scale variation at mean value. 2. Viewing of the view box of the periapical radiographs, experimental tooth root resorption of the periapical area of the first premolar, middle of mesial surface of the first molar mesial root, middle of lingual surface of the first molar distal root were recognized by increased diameter. 3. On the analysis by histogram, the periapical area of the first premolar, the middle of mesial surface of the first molar mesial root were each recognized tooth root resorption of the 5,6,7 pixel, 2,4,5 pixel by increased diameter. 4. On the analysis by histogram, the middle of lingual surface of the first molar distal root was each recognized tooth root resorption of the none, 3,6 pixel by increased diameter.