• Title/Summary/Keyword: contrast analysis

Search Result 3,295, Processing Time 0.031 seconds

The Clothing Image according to Coloration, Tone, and Interval of Checked Pattern in Color Contrast (색상대비 체크무늬의 배색, 톤, 간격에 따른 의복이미지)

  • Jeong, Su-Jin;Choi, Su-Koung
    • Fashion & Textile Research Journal
    • /
    • v.13 no.2
    • /
    • pp.147-154
    • /
    • 2011
  • The purpose of this study was to investigate the clothing image according to coloration, tone, and interval of checked pattern in color contrast. The experimental materials developed for this study were a set of stimulus and response scales. The stimuli were 24 color pictures, in which coloration(RB: Red+Blue, YP: Yellow+Purple), tone(light, dull, dark), and interval(0.5 cm, 1.5 cm, 3.5 cm, 5.5 cm) were manipulated. The 7-point scale was used for evaluation of clothing image. Data were obtained from 240 female college students living in Seoul, Gwangju, Jinju, and Masan on May 2010. For data analysis, ANOVA and Duncan-test were used by using SPSS program. Results of this study were as follows.; Clothing image according to coloration, tone, and interval of checked pattern consisted of five dimensions of attractiveness, freshness, appeal, modesty, and activity. Coloration showed an independent effect on attractiveness and appeal. Tone showed an independent effect on freshness, appeal, and modesty. Interval showed an independent effect on freshness. Also, interaction effects of coloration and tone on appeal were found. Interaction effects of coloration and interval on modesty were found.

A Study on Cognition and Perception of Space through Contrast and Integration of Light and Darkness (빛과 어둠의 대비와 통합에 나타난 공간의 지각과 인식에 관한 연구)

  • Kim, Jong-Jin
    • Korean Institute of Interior Design Journal
    • /
    • v.19 no.5
    • /
    • pp.3-10
    • /
    • 2010
  • In the history of art and architecture, there are different characteristics in relationship between light and space. Among them, two characteristics seem to be fundamental : The first is that contrast between light and darkness is more articulated. Direct sunlight penetrates into the dark interior space made by heavy masonry structure. This is generally found in the traditional western religious buildings. The second is that light is mixed with darkness and becomes shade. Shade is different from shadow that is usually perceived as the opposite of light. Sunlight is filtered under through the big horizontal roof and rice paper walls in the traditional far-east Asian architecture and becomes weak ambient light. In this shade, there is no strong contrast between light and darkness. This difference is not only originated from the architectural differences, but also originated from the conceptual differences about light, space, and the world in two cultures. This paper tries to study the philosophical, aesthetical backgrounds as well as case examples in art and architecture of two characteristics. Based on the case studies, this paper aims to analyze the main perceptual structure. Finding the relationship between light, space, and human body by making three dimensional models is the crucial analysis method of this research. Although in real life and experiencing the world, these two characteristics are not clearly separated, comparative study based on different cultures gives opportunity to think of diverse perspectives on light and space.

MR Spectroscopy of Cerebral Fat Embolism in Cats

  • Park Byung-Rae
    • Biomedical Science Letters
    • /
    • v.11 no.2
    • /
    • pp.221-225
    • /
    • 2005
  • To investigate the spectroscopic findings of embolized lesions induced with a fat-emulsion technique with magnetic resonance images (MRI). A fat emulsion was made with 0.1 ml of triolein and 20 ml of normal saline. In 12 cats, the internal carotid artery was infused with the fat emulsion. Contrast-enhanced T1-weighted MRI and multivoxel spectroscopy were obtained at 1 hour, 1 and 4 days, and 1 week after embolization. NAA (N-acetylaspartate), Cr (creatine) and Cho (choline) were evaluated on the spectroscopy. Statitistical analysis wsperformed at the embolized and contralateral normal hemisphere in the integral and amplitude of NAA, Cr and Nho in time course. Also NAA/Cr and Cho/Cr were compared in both hemisphere and in time course. The emboli zed lesions showed contrast enhance ments on Gd-enhanced Tl-weighted i~ages at 1 hour. This contrast enhancement was decreased at day 1, and id not appear agter day 4. In spectroscopy, the embolized hemisphere showed no statistical difference to the normal contralateral side at 1 hour and in time course. NAA/Cr and Cho/Cr were not significantly different in both hemispheres at 1 hour and in time course. Cerebral-fat embolism induced by a triolein emulsion in cats revealed no statistical difference on MR spectroscopy. Triolein-emulsion can be used in the study of blood-brain barrier.

  • PDF

The Study of the Printability on the Phenol Free Heat-Set Web Inks(II) - Analysis by the trial printing test - (Phenol Free Heat-Set 윤전 잉크의 인쇄적성에 관한 연구(제2보) - 실 인쇄 실험에 의한 분석 -)

  • Ha, Young-Baeck;Oh, Sung-Sang;Lee, Won-Jae
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.44 no.3
    • /
    • pp.41-48
    • /
    • 2012
  • Materials used for the inks in the printing industry is an important material following the paper. The composition of the ink is pigment and organic solvents. However, Ink is used in a variety of chemicals, they are classified as non-green. Therefore, rosin-modified phenolics manufactured by the reaction of phenol and formaldehyde can take the place of eco-phenol free resin and by experiment density, gloss, trapping, contrast and dot gain of printing has been studied as printability. The result of study can support that the properties of printing using eco-phenol free resin such as density, gloss, contrast and trapping is similar to existing ink. In the part of dot gain, the result is excellent. So we were thought to be able to improve some characteristics such as dispersion of black ink, that will be possible for the field applicability.

Research on the Technology of Alternative Continuous Wide Spectral Spatial Heterodyne Spectrometer

  • Zhang, Wenli;Tian, Fengchun;Zhao, Zhenzhen;Song, An;Zhang, Li
    • Current Optics and Photonics
    • /
    • v.1 no.4
    • /
    • pp.295-307
    • /
    • 2017
  • An innovative system for the alternative continuous wide spectral spatial heterodyne spectrometer (ACWS-SHS) is proposed. The relationship between the ACWS-SHS and the wide spectral spatial heterodyne spectrometer (WS-SHS) at the resolution limit, the spectral range, the grating diffraction efficiency and the interference fringes contrast ratio has been analyzed theoretically. Through the comparison of the theoretical analysis and simulation results, it is found that the two systems for the WS-SHS and the ACWS-SHS have the same resolution limit and spectral range, which are ${\delta}{\sigma}$ and ${\sigma}_{01}$, while in the ACWS-SHS system the critical diffraction efficiency of echelle grating is 68.39% and the critical contrast ratio of interference fringes is 0.4135, which is much better than the performance of the WS-SHS system. Therefore, the ACWS-SHS reduces the high requirements for the precision of equipment and expands the application field of SHS effectively.

Maximum TE Setting Range for Quantitatively Evaluating T2 Relaxation Time : Phantom Study (T2 이완시간의 정량적 평가에 있어서 Maximum TE의 설정 범위에 대한 연구 : 팬텀연구)

  • Park, Jin Seo;Kim, Seong-Ho
    • Journal of radiological science and technology
    • /
    • v.41 no.1
    • /
    • pp.25-31
    • /
    • 2018
  • This study aimed to evaluate the range of maximum TE that could measure T2 relaxation time accurately by setting diverse maximum TE with using contrast medium phantoms. Contrast medium phantoms ranging from low to high concentrations were made by using Gadoteridol. The relaxation time and relaxation rate were compared and evaluated by conducting T2 mapping by using reference data based on various TEs and data obtained from different maximum TEs. It was found that accurate T2 relaxation time could be expressed only when the maximum TE over a certain range was used in the section with long T2 relaxation time, such as the low concentration section of saline or gadolinium contrast medium. Therefore, the maximum TE shall be longer than the T2 relation time for accurately maturing the T2 relaxation of a certain tissue or a substance.

Clinical Usefulness of Contrast Echocardiography: The Dose Effect for Left Ventricle Visualization in Dogs (심초음파의 조영제의 임상적 유용성: 개에서 좌심영상화에 대한 조영제 용량의 영향)

  • Shin, Chang-ho;Hwang, Tae-sung;Yoon, Young-min;Jung, Dong-in;Yeon, Seong-chan;Lee, Hee-chun
    • Journal of Veterinary Clinics
    • /
    • v.32 no.6
    • /
    • pp.486-490
    • /
    • 2015
  • Two-demensional echocardiography is routinely used for evaluation of cardiac function. Visualization of the endocardial border is essential for the assessment of global and regional left ventricular with cardiac disease. SonoVue$^{TM}$ is a microbubble contrast agent that consists of sulfur hexafluoride-filled microbubbles in a phospholipid shell. There were many studies about contrast echocardiographic examination using SonoVue$^{TM}$ contrast agent, and various doses of SonoVue$^{TM}$ were used. To our knowledge, in published veterinary medicine, there was not reported for diagnostic efficient dose of SonoVue$^{TM}$ to evaluate contrast enhanced left ventricular endocardial border delineation (LVEBD). The purpose of this study is to compare the visualization time of LVEBD and find efficient dose of SonoVue$^{TM}$ for using various doses in dogs. Ten healthy Beagles were recruited to the study. Three different doses (0.03 ml/kg, 0.05 ml/kg and 0.1 ml/kg) of SonoVue$^{TM}$ were injected. Endocardial segments were assigned based on previously established methodology, where by the four-chamber views of the LV were divided into 6 segments. In this study, Contrast enhancement of the LVEBD after each injection was evaluated visually at the time point of overall contrast enhancement (Segmental scoring 5+) in the LV by three investigators in a blind manner. Statistical analysis was performed with SPSS version 14.0. All data were analyzed using one-way ANOVA, the multiple comparison Scheffe test. When data for the three offsite readers were combined, mean durations of useful contrast were $3.54({\pm}2.14)$, $6.15({\pm}2.61)$, and $24.39({\pm}11.10)$ seconds for the 0.03 ml/kg, 0.05 ml/kg, and 0.1 ml/kg SonoVue$^{TM}$ doses, respectively. After injection of contrast agent, there were no significant change in side effects such as urticaria, angioedema, hypersensitivity reactions, and digestive system disorders. This study suggests that efficient dose of SonoVue$^{TM}$ contrast agent for improvement of the left ventricle visualization is 0.1 ml/kg. The duration of useful enhancement of LVEBD and the reproducibility were also the highest at the 0.1 ml/kg dosage.

Video image analysis algorithms with happy emotion tree (영상 이미지 행복 감성 트리를 이용한 분석 알고리즘)

  • Lee, Yean-Ran;Lim, Young-Hwan
    • Cartoon and Animation Studies
    • /
    • s.33
    • /
    • pp.403-423
    • /
    • 2013
  • Video images of emotional happiness or unhappiness, stress or emotional division of tranquility in the form of a tree is evaluated by weighting. Representative evaluation of the video image brightness contrast sensitivity ratings 1 car happy, unhappy or nervous, calm and refined with two car dependency, sensitivity to visual images are separated. Emotion Recognition of four compared to the numerical data is measured by brightness. OpenCV implementation through evaluation graph the stress intensity contrast, tranquility, happiness, unhappiness with changes in the value of four, separated by sensitivity to computing. Contrast sensitivity of computing the brightness according to the input value 'unhappy' to 'happy' or 'stress' to 'calm' the emotional changes are implemented. Emotion computing the regularity of the image to calculate the sensitivity localized computing system can be controlled according to the emotion of the contrast value of the brightness changes are implemented. The future direction of industry on the application of emotion recognition will play a positive role.

An Intelligent Surveillance System using Fuzzy Contrast and HOG Method (퍼지 콘트라스트와 HOG 기법을 이용한 지능형 감시 시스템)

  • Kim, Kwang-Baek
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.6
    • /
    • pp.1148-1152
    • /
    • 2012
  • In this paper, we propose an intelligent surveillance system using fuzzy contrast and HOG method. This surveillance system is mainly for the intruder detection. In order to enhance the brightness difference, we apply fuzzy contrast and also apply subtraction method to before/after the surveillance. Then the system identifies the intrusion when the difference of histogram between before/after surveillance is sufficiently large. If the incident happens, the camera stops automatically and the analysis of the screen is performed with fuzzy binarization and Blob method. The intruder is detected and tracked in real time by HOG method and linear SVM. The proposed system is implemented and tested in real world environment and showed acceptable performance in both detection rate and tracking success rate.

Four Dimension(4D) Time Resolved Imaging of Contrast Kinetics(TRICKS) MR Angiography (4차원 영상기법 Time Resolved Imaging of Contrast Kinetics MRA의 유용성)

  • Lim, cheong-hwan;Bae, sung-jin
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.1105-1110
    • /
    • 2009
  • To assess the clinical value of time resolved imaging of contrast kinetics(TRICKS) MRA by comparison with conventional time of flight(TOF) MR angiography. Both TOF-MRA and TRICKS-MRA were performed in 17 patients with cerebrovascular disease and in 6 patients with brain tumor. Among 17 cerebraovascular patients, digital subtraction angiography(DSA) data were also obtained in 11 patients. TOF-MRA showed good spatial resolution but short in temporal resolution. Although TRICKS-MRA showed somewhat low spatial resolution, it showed superior temporal resolution by distinguishing vessel and tumor in all patients. Also, from the analysis of vessel-tumor relationship, TRICKS-MRA showed better performance than TOF-MRA. TRICKS-MRA makes it possible to image arterial, capillary and venous phase sequentially with very speedy manner and therefore, the clinical use of this method is highly suggestive for future use.

  • PDF