• 제목/요약/키워드: continuous system

검색결과 6,359건 처리시간 0.034초

A Continuous Evaluation Processes for Information Security Management

  • Choi, Myeonggil
    • Journal of Information Technology Applications and Management
    • /
    • 제23권3호
    • /
    • pp.61-69
    • /
    • 2016
  • Growing information threats have threatened organization to lose information security controls in these days. Many organizations have accepted the various information security management systems does mention necessity of a continuous evaluation process for the executions of information security management in a theoretical aspect. This study suggests a continuous evaluation process for information security management reflecting the real execution of managers and employees in organizations.

연속시간 자기동조 제어기의 강인성 (Robustness of Continuous-time Self-Tuning Control)

  • 김종문;허욱열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 추계학술대회 논문집 학회본부
    • /
    • pp.360-364
    • /
    • 1989
  • In this paper, the robustness of self tuning controller for continuous time system is investigated. The continuous time least square algorithm is used in estimating parameters. The main control algorithm is the pole-zero placement control. The effects of unmodeled dynamics on continuous time approach and discrete-time approach are compared.

  • PDF

SLIDING MODE MOULD LEVEL CONTROL IN CONTINUOUS CASTING PROCESS

  • Kueon, Yeong-Seob
    • 한국생산제조학회지
    • /
    • 제7권4호
    • /
    • pp.50-55
    • /
    • 1998
  • Mould level control system for continuous casting process involves stick-slip friction in the sliding gate , time-delay, non-linearity, and certain uncertainties such as friction force variations between molten steel and the inner wall of mould. In this paper, sliding mode control technique was used to solve these complex control problem. The controller is then designed and implemented onto the continuous casting process. Testing result shows that sliding mode controller can decrease the fluctuating magnitude of the mould level and is superior to the existing PID controller.

Treatment of Refractory Chylous Ascites with an Innovative Peritoneovenous Shunt: Temporary Usage of a Continuous Renal Replacement System: A Case Report

  • Park, Jiyoun;Lee, Jae Jun;Lee, Jung Hee;Shim, Young Mog
    • Journal of Chest Surgery
    • /
    • 제55권1호
    • /
    • pp.81-84
    • /
    • 2022
  • Esophagectomy and esophageal reconstruction are commonly chosen as surgical options for esophageal cancer. However, prolonged untreated chyle leakage is associated with a poor prognosis. We report the case of a patient with refractory chylous ascites. To limit the ongoing fluid loss, we utilized the chylous ascites as an additional fluid source in a renal replacement therapy system. A continuous renal replacement therapy (CRRT) drainage system was modified to drain both the chylous ascites and venous blood. The ascites drainage rate was determined empirically and regulated by a dial-flow extension set. The CRRT mode was set to continuous venovenous hemodiafiltration and maintained for 7 days. After the patient was weaned from CRRT, ascites did not reaccumulate, and the patient's general condition improved dramatically. No infections related to the system occurred. This procedure temporarily alleviates symptoms and provides more time for alternative treatment strategies.

Nitrate reduction by iron supported bimetallic catalyst in low and high nitrogen regimes

  • Hamid, Shanawar;Lee, Woojin
    • Advances in environmental research
    • /
    • 제4권4호
    • /
    • pp.263-271
    • /
    • 2015
  • In this study, the effect of initial nitrate loading on nitrate removal and byproduct selectivity was evaluated in a continuous system. Nitrate removal decreased from 100% to 25% with the increase in nitrate loading from 10 to $300mg/L\;NO_3-N$. Ammonium selectivity decreased and nitrite selectivity increased, while nitrogen selectivity showed a peak shape in the same range of nitrate loading. The nitrate removal was enhanced at low catalyst to nitrate ratios and 100% nitrate removal was achieved at catalyst to nitrate ratio of ${\geq}33mg\;catalyst/mg\;NO_3-N$. Maximum nitrogen selectivity (47%) was observed at $66mg\;catalyst/mg\;NO_3-N$, showing that continuous Cu-Pd-NZVI system has a maximum removal capacity of 37 mg $NO_3{^-}-N/g_{catalyst}/h$. The results from this study emphasize that nitrate reduction in a bimetallic catalytic system could be sensitive to changes in optimized regimes.

Modeling of a Continuous-Time System with Time-delay

  • Park, Jong-Jin;Choi, Guy-Seok
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제4권2호
    • /
    • pp.1-6
    • /
    • 2012
  • Control Theory for continuous-time system has been well developed. Due to the development of computer technology, digital control scheme are employed in many areas. When delays are in control systems, it is hard to control the system efficiently. Delays by controller-to-actuator and sensor-to-controller deteriorate control performance and could possibly destabilize the overall system. In this paper, a new approximated discretization method and digital design for control systems with multiple state, input and output delays and a generalized bilinear transformation method with a tunable parameter are also provided, which can re-transform the integer time-delayed discrete-time model to its continuous-time model. Illustrative examples are given to demonstrate the effectiveness of the developed method.

자기유변유체 댐퍼를 이용한 운전석의 진동감쇠에 대한 연구 (A Study on The Vibration Reduction of a Driver Seat Controlling an MR Fluid Damper)

  • 안병일;전도영
    • 제어로봇시스템학회논문지
    • /
    • 제8권10호
    • /
    • pp.861-866
    • /
    • 2002
  • A seat suspension system with a controlled MR(Magneto Rheological) fluid damper is introduced to improve the ride quality and prevent the health risk of a driver compared to fixed seats. The system is located between a seat cushion and the base, and is composed of a spring, MR fluid damper and controller. The MR fluid damper designed in valve mode is capable of producing a wide range of damping force according to applied currents. In experiments, a person was sitting on the controlled seat excited by a hydraulic system The skyhook control, continuous skyhook control and relative displacement control were applied and the continuous skyhook control improved the vibration suppression by 36.6%.

연속시간 유한정정제어기의 설계방법 고찰 (A Study on the Design Method of a Continuous Time Deadbeat Controller)

  • 김성열;이금원
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.326-326
    • /
    • 2000
  • Continuous time system deadbeat controller(CdbC) has been studied mainly since 1992 especially by Japan researchers. They suggested delay elements. These elements stem from the finite Laplace Transform which is the starting point in deadbeat control system design in continuous time system. Every transfer function is established by these elements. From some conditions such as internal model stability and peasibility of a CdbC controller. unknown polynomials or coefficients can be calculated. In this paper, optimal pole placement of the closed loop system is suggested. From this. a CdbC controller with lower order can be obtained which attains the same level of weighted sensitivity function's H$_{\infty}$ norm used as a measure of the robustness property as existing CdbCs.

  • PDF

복사열전달을 고려한 고층아파트 연속난방 열공급제어 시뮬레이션 (Simulation of Heat Supply Control of Continuous Heating System of Multistoried Apartment in Consideration of Radiation Heat Transfer)

  • 최영돈;홍진관;윤종호;이남호
    • 설비공학논문집
    • /
    • 제6권2호
    • /
    • pp.78-92
    • /
    • 1994
  • Thermal performance of pipe network of continuous heating system controlled by thermostat and flow control valve was simulated in consideration of radiation heat transfer and solved by linear analysis method. Thermal performance of real apartment building with radiant floor heating system was simulated by equivalence heat resistance-capacity method. This method enables to simulate the unsteady variation of temperature or each element of building. Heat transfer characteristics of each element were also investigated.

  • PDF

연속계 Deadbeat제어를 적용한 도립진자 제어 (Control of Inverted Pendulum Using Continuous Time Deadbeat Control)

  • 김진용;김성열;이금원
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.555-558
    • /
    • 2004
  • Due to the asymptotic property, deadbeat control can hardly applied to the continuous time system control. But some delay element method can deal such a problem. Except delay element method, well-known digital deadbeat control can br used with the aid of som smoothing elements. In this paper, and order smoothing element is used for the smoothing of the digital deadbeat controller. And this element is argumented to the plant, and so control problem is to control digitally the argumented system. We simulated this control system using Matlab language and finally apply this algorithm to the rotary inverted pendulum system.

  • PDF