• Title/Summary/Keyword: continuous method

Search Result 5,661, Processing Time 0.041 seconds

Preliminary Study on the MR Temperature Mapping using Center Array-Sequencing Phase Unwrapping Algorithm (Center Array-Sequencing 위상펼침 기법의 MR 온도영상 적용에 관한 기초연구)

  • Tan, Kee Chin;Kim, Tae-Hyung;Chun, Song-I;Han, Yong-Hee;Choi, Ki-Seung;Lee, Kwang-Sig;Jun, Jae-Ryang;Eun, Choong-Ki;Mun, Chi-Woong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.12 no.2
    • /
    • pp.131-141
    • /
    • 2008
  • Purpose : To investigate the feasibility and accuracy of Proton Resonance Frequency (PRF) shift based magnetic resonance (MR) temperature mapping utilizing the self-developed center array-sequencing phase unwrapping (PU) method for non-invasive temperature monitoring. Materials and Methods : The computer simulation was done on the PU algorithm for performance evaluation before further application to MR thermometry. The MR experiments were conducted in two approaches namely PU experiment, and temperature mapping experiment based on the PU technique with all the image postprocessing implemented in MATLAB. A 1.5T MR scanner employing a knee coil with $T2^*$ GRE (Gradient Recalled Echo) pulse sequence were used throughout the experiments. Various subjects such as water phantom, orange, and agarose gel phantom were used for the assessment of the self-developed PU algorithm. The MR temperature mapping experiment was initially attempted on the agarose gel phantom only with the application of a custom-made thermoregulating water pump as the heating source. Heat was generated to the phantom via hot water circulation whilst temperature variation was observed with T-type thermocouple. The PU program was implemented on the reconstructed wrapped phase images prior to map the temperature distribution of subjects. As the temperature change is directly proportional to the phase difference map, the absolute temperature could be estimated from the summation of the computed temperature difference with the measured ambient temperature of subjects. Results : The PU technique successfully recovered and removed the phase wrapping artifacts on MR phase images with various subjects by producing a smooth and continuous phase map thus producing a more reliable temperature map. Conclusion : This work presented a rapid, and robust self-developed center array-sequencing PU algorithm feasible for the application of MR temperature mapping according to the PRF phase shift property.

  • PDF

A Comparative Study of Two Different Heel Lancet Devices for Blood Collection in Preterm Infants (미숙아에서 채혈을 위한 발뒤꿈치 천자시 두 종류 천자 기구의 비교)

  • Lim, Hyo-Bin;Rhu, Mi-Joo;Jung, Ji-Mi;Jeon, Ga-Won;Sin, Jong-Beom
    • Neonatal Medicine
    • /
    • v.17 no.2
    • /
    • pp.239-244
    • /
    • 2010
  • Purpose: To evaluate two different heel lancet device in terms of pain response and success of the procedure in the preterm infants undergoing heel puncture. Methods: 100 preterm infants undergoing capillary blood gas analysis or capillary bilirubin monitoring underwent heel puncture, were randomly allocated to blood sampling from the heel with either a conventional manual lancet or an automatic incision device. Primary outcome measures included the Premature Infants Pain Profile (PIPP) score, total duration of procedure, number of heel puncture and number of bruise. The pain response was evaluated using PIPP score and the effectiveness was evaluated using three criteria: total duration of blood sampling, number of puncture, bruising of the heel or ankle. Statistical analysis was performed using the SPSS ver. 13.0 program. Difference between the groups were analysed with t test (continuous variables) and the Chi square test or Fisher test (categorical variables). Results: The mean PIPP score was 4.91 for the automatic lancet group compared with 5.84 for the conventional manual lancet group (P=0.0255).The number of pain scores above 7 during blood collection did not differ between two groups (P=0.2167). The procedure took less time to perform in the automatic lancet group (mean, 30.69 seconds) than in the conventional lancet group (mean, 48.92 seconds) (P<0.0001). Conclusion: This study demonstrated that the automatic lancet device causes less pain and a shorter procedure time than the conventional manual lancet in preterm infants undergoing heel puncture. On the basis of these results the automatic lancet device is very useful method for blood collection in preterm infants by heel puncture.

Availability of Oral Hygiene Devices for the Patients with Smoking in some Dental Clinics (일부 치과병원 흡연환자의 구강위생용품 이용도)

  • Jang, Kyeung-Ae;Seong, Mi-Gyung;Kang, Hyun-Kyung;Choi, Jung-Ok;Kim, Yoon-Sin
    • Journal of dental hygiene science
    • /
    • v.8 no.1
    • /
    • pp.7-12
    • /
    • 2008
  • The purpose of this study is to improve the oral health after understanding the usage status of oral health items and to conduct active guidance for prohibition of smoking. The survey of 326 visitors for continuous oral health management in the dentist from April 2nd 2007 to May $20^{th}$ is accomplished. The data is handled from the SPSS 12.0 statistics program and we can get the results like below. 1. The number of people answering the usage of the smooth toothbrush is 64.5% which is higher in smoking peoples than in non-smoking ones (p < 0.001). Non-smoking people 61.4% answering '3 minutes more' per brushing their teeth is higher than smoking respondents. 2. The more used device is the interdental brush by non-smoking people 36.7% than smoking ones and the answer. 3. The percentage answering 'recommendation in the dentist' in the question about the motive using the oral health devices are nearly same in 69.6 % and 67.5% by non-smoking and smoking persons. The most reason not using these devices is 'don't know how to use this' and the number of smoking guys is 38.7% which is higher than that of non-smoking ones(p < 0.05). 4. The percentage of answering 'regular visiting the dentist', the method for oral health management is 28.3% in smoking parts and 35.3% in non-smoking ones which is slightly higher. From this study, the usage and the recognition of oral hygiene devices of the patient with smoking is a little bit lower than those of non-smoking patients and small difference is shown. So public relations of the effects and the necessity of the oral hygiene devices to all people have to be performed and the education and the activity prohibiting smoking are expanded by the dental hygienist based on the understanding of oral health when the patients are smoking or not.

  • PDF

Shallow Subsurface Structure of the Yaksoo Area, Ulsan, Korea by Geophysical Surveys (물리탐사기법에 의한 울산광역시 약수지역 천부지하구조 조사)

  • Lee, Jung-Mo;Kong, Young-Sae;Chang, Tae-Woo;Park, Dong-Hee;Kim, Tae-Kyung
    • Journal of the Korean Geophysical Society
    • /
    • v.3 no.1
    • /
    • pp.57-66
    • /
    • 2000
  • The location and geometry of the Ulsan Fault play important roles in interpreting tectonic evolution of the southeastern part of the Korean Peninsula. Dipole-dipole electrical resistivity surveys and seismic refraction surveys were carried out in the Yaksoo area, Ulsan in order to measure the thickness of the alluvium covering the Ulsan Fault and to find associated fracture zones and possibly the location of its major fault plane. The collected data were analyzed and interpreted. Some results reported previously by others were also used in this interpretation. No low resistivity anomalies were found in the cross-sectional resistivity image of the survey line located in the east of the Dong River. In contrast, well-developed continuous low resistivity anomalies were detected in the west of the Dong River. This strongly suggests that the major fault plane of the Ulsan Fault is located under or in the west part of the Dong River. Two refraction boundaries corresponding to the underground water level and the bottom of the alluvium were found by refraction surveys carried out on the limited part of the east survey line. The thickness of the alluvium was found to be about 30 m. Small faults in the basement rock identified by reflection surveys were not detected by both resistivity and refraction seismic surveys. This might be explained by assuming that low resistivity anomaly is more closely related to the clay contents than the water contents. On the other hand, it may be resulted by the limited resolution of the resistivity and refraction surveys. Detailed study is required to clarify the reason. Resistivity survey is frequently considered to be a good exploration method to detect subsurface faults. However, it appears to be less useful than reflection seismic survey in this work. In dipole-dipole resistivity survey, the number of separation should be increased to survey deeper subsurface with the same resolution. However, signal to noise ratio decreases as the number of separation increases. In this survey area, the signal to noise ratio of up to sixteen separations was good enough based on the statistical properties of measurements.

  • PDF

The Analysis of Activities and Satisfaction of Volunteers for Hospice Care (호스피스 자원봉사자의 활동 및 만족도 분석)

  • Kim, Boon-Han;Jung, Yun;Park, Kyung-Bok
    • Journal of Hospice and Palliative Care
    • /
    • v.5 no.2
    • /
    • pp.163-171
    • /
    • 2002
  • Purpose : The purpose of this study was to analyze activities and satisfaction of volunteers for hospice care. Methods : We used 271 reports of hospice care and 20 questionnaire of activities and satisfaction of volunteers for hospice care from volunteers of in a community. Window SPSS-PC was used for the data analysis and the statistical method used were the descriptive statistics, t-test, ANOVA and Pearson's correlation coefficient. Results : 1) The highest score of activity was emotional area and the next activities was physical area. 2) The degree of emotional area (t=4.94, P<.05) and spiritual area (t=3.80, P<.05) was influence by religion of volunteers. 3) The mean score of satisfaction was 3.61. 4) There was correlation between duration of activity and death experience (r=.558, P<.05), emotional care (r=.698, P<.01), spiritual care (r=.474, P<.05), satisfaction (r=.651, P<.01), and the between physical care and family care (r=.559, P<.05), and the between spiritual cue and family care (r=.512, P<.05), and between emotional care and satisfaction (r=.536, P<.05). Conclution : The above result indicated that we must develope the management and education of volunteer of hospice care for various hospice care. Also, We should to encouraged the continuous education and efficient management.

  • PDF

Study on Evaluation of Carbon Emission and Sequestration in Pear Orchard (배 재배지 단위의 탄소 배출량 및 흡수량 평가 연구)

  • Suh, Sanguk;Choi, Eunjung;Jeong, Hyuncheol;Lee, Jongsik;Kim, Gunyeob;Sho, Kyuho;Lee, Jaeseok
    • Korean Journal of Environmental Biology
    • /
    • v.34 no.4
    • /
    • pp.257-263
    • /
    • 2016
  • Objective of this study was to evaluate the carbon budget on 40 years old pear orchard at Naju. For carbon budget assessment, we measured the soil respiration, net ecosystem productivity of herbs, pear biomass and net ecosystem exchange. In 2015, pear orchard released about $25.6ton\;CO_2\;ha^{-1}$ by soil respiration. And $27.9ton\;CO_2\;ha^{-1}$ was sequestrated by biomass growth. Also about $12.6ton\;CO_2\;ha^{-1}$ was stored at pruning branches and about $5.2ton\;CO_2\;ha^{-1}$ for photosynthesis of herbs. As a result, 25.6 ton of $CO_2$ per ha is annually released to atmosphere. At the same time about 45.7 ton of $CO_2$ was sequestrated from atmosphere. When it sum up the amount of $CO_2$ release and sequestration, approximately $20.1ton\;CO_2\;ha^{-1}$ was sequestrated by pear orchard in 2015, and it showed no significant differences with net ecosystem exchanges ($17.8ton\;CO_2\;ha^{-1}\;yr^{-1}$) by eddy covariance method with the same period. Continuous research using various techniques will help the understanding of $CO_2$ dynamics in agroecosystem and it can be able to present a new methodology for assessment of carbon budget in woody crop field. Futhermore, it is expected that the this study can be used as the basic data to be recognized as a carbon sink.

Modified Blalock-Taussig Shunt for the Patients with Complex Congenital Heart Defects in Early Infancy (조기 영아기에 시행된 복합 심기형 환자들에서의 변형 Blalock-Taussig 단락술)

  • Lim Hong Gook;Kim Woong-Han;Hwang Seong Wook;Lee Cheul;Kim Chong Whan;Lee Chang-Ha
    • Journal of Chest Surgery
    • /
    • v.38 no.5 s.250
    • /
    • pp.335-348
    • /
    • 2005
  • Background: This retrospective review examines the preoperative condition, postoperative course, mortality and cause of death for the patients who underwent modified Blalock-Taussig shunt for complex congenital heart defects in early infancy. Material and Method: Fifty eight patients underwent modified Blalock-Taussig shunts from January 2000 to November 2003. The mean age at operation was $23.1\pm16.2$ days ($5\~81\;days$), and the mean body weight was $3.4\pm0.7\;kg\;(2.1\~4.3\;kg)$. Indications for surgery were pulmonary atresia with ventricular septal defect in 12 cases, pulmonary atresia with intact ventricular septum in 17, single ventricle (SV) in 18, and hypoplastic left heart syndrome (HLHS) in 11. Total anomalous pulmonary venous return (TAPVR) was associated with SV in 4 cases. Result: There were 11 ($19.0\%$) early, and 5 ($10.6\%$) late deaths. Causes of early death included low cardiac output in 9, arrhythmia in 1, and multiorgan failure in 1. Late deaths resulted from pneumonia in 2, hypoxia in 1, and sepsis in 1. Risk factors influencing mortality were preoperative pulmonary hypertension, metabolic acidosis, use of cardiopulmonary bypass, HLHS and TAPVR. Twenty four patients ($41.4\%$) had hemodynamic instability during the 48 postoperative-hours. Six patients underwent shunt revision for occlusion, and 1 shunt division for pulmonary overflow. Conclusion: Modified Blalock-Taussig shunt for complex congenital heart defects in early infancy had satisfactory results except in high risk groups. Many patients had early postoperative hemodynamic instability, which means that continuous close observation and management are mandatory in this period. Aggressive management may appear warranted based on understanding of hemodynamic changes for high risk groups.

Effect of Aprotinin on Changes in Plasma Thromboxane $B_2$ and Endothelin-1 Concentratin after Extracorporeal Circulation (체외순환후 혈중 Thromboxane $B_2$와 Endothelin-1 농도 변화에 미치는 Aprotinin의 효과)

  • Lim, Cheong;Yun, Tae-jin;Kim, Yeon-seung;Kim, Seung-hoo;Lee, Jae-dam;Rho, Joon-Ryang;Song, Meong-Gun
    • Journal of Chest Surgery
    • /
    • v.33 no.3
    • /
    • pp.221-229
    • /
    • 2000
  • Background: Thromboxane A2 and endothelin-1 are the potent vasoconstrictors affecting pulmonary pathophysiology in response to whole body inflammatin following CPB. Aprotinin, as an antiiflammatory agent, may decrease the release of such vasoactive substance from pulmonary tissues, preventing pulmonary hypertension after cardiopulmonary bypass. Material and Method: Ten mongrel dogs(Bwt. ac. 20kg) were subjected to cardioupulmonary bypass for 2 hours and postbypass pulmonary vascular resistance(0, 1, 2, 3 hours) were compared with prebypass level. The dogs were divided into 2 groups; control group(n-5) and aprotinin group(n=5). In the aprotinin group, aprotinin was administered as follows; 50,000 KIU/kg mixed in pump priming solution, 50,000 KIU/kg prebypass intravenous infusion over 30 minutes, 10,000 KIU/kg/hour postbypass continuous infusion. Prebypass and postbypass 0, 1, 2, 3 hour pulmonary vascular resistance were measured. At prebypass and postbypass 0, 90, 180 minutes, blood samples were obtained from pulmonary arterial and left atrial catherers for the assay of plasma thromboxane B2 a stable metabolite of thromboxane A2, and endothelin-1 concentrations. Result: The ratios of pustbypass over prebypass pulmonary vascular at postbypass 0, 1, 2, 3 hours were 1.28$\pm$0.20, 1.82$\pm$0.23, 1.90$\pm$0.19, 2.14$\pm$0.18 in control group, 1.58$\pm$0.18, 1.73$\pm$0.01, 1.66$\pm$0.10, 1.50$\pm$0.08 in aprotinin group ; the ratios gradually increased in control group while decreased or fluctuated after postbypass 1 hour in aprotinin group. There was statistically significant difference between control group and aprotinin group at postbypass 3 hours(P=0.014). Pulmonary arterial plasma concentration of thromboxane B2(pg/ml) at prebypass, postbypass 0, 90, 180 minutes were 346.4$\pm$61.9, 529.3$\pm$197.6, 578.3$\pm$255.8, 493.3$\pm$171.3 in control group, 323.8$\pm$118.0, 422.6$\pm$75.6, 412.3$\pm$59.9, 394.5$\pm$154.0 in aprotinin group. Left atrial concentrations were 339.3$\pm$89.2, 667.0$\pm$65.7, 731.2$\pm$192.7, 607.5$\pm$165.9 in control group, 330.0$\pm$111.2, 468.4$\pm$190.3, 425.4$\pm$193.6, 4.7.3$\pm$142.8 in aprotinin group. These results showed decrement of pulmonary thromboxane A2 generation in aprotinin group. Pulmonary arterial concentrations of endothelin-1(fmol/ml) at the same time sequence were 7.84$\pm$0.31, 13.2$\pm$0.51, 15.0$\pm$1.22, 16.3$\pm$1.73 in control group, 7.76$\pm$0.12, 15.3$\pm$0.71, 22.6$\pm$6.62, 14.9$\pm$1.11 in aprotinin group. Left atrial concentrations were 7.61$\pm$17.2, 57.1$\pm$28.4, 18.9$\pm$18.2, 31.5$\pm$20.5 in control group, 5.61$\pm$7.61, 37.0$\pm$26.2, 28.6$\pm$21.7, 37.8$\pm$30.6 in aprotinin group. These results showed that aprotinin had no effect on plasma endothelin-1 concentration after cardiopulmonary bypass. Conclusion: Administration of aprotinin during cardiopulmonary bypass could attenuate the increase in pulmonary vascular resistance after bypass. Inhibition of pulmonary thromboxane A2 generation was thought to be one of the mechanism of this effect. Aprotinin had no effect on postbypass endothelin-1 concentration.

  • PDF

Early and Mid-Term Results of MIDCAB (최소 침습적 관상 동맥 우회술의 중단기 성적)

  • 손호성;방영호;황진욱;민병주;조양현;박성민;이성호;김광택;선경
    • Journal of Chest Surgery
    • /
    • v.37 no.10
    • /
    • pp.827-832
    • /
    • 2004
  • Background: The significance of MIDCAB is emerging topics recently as OPCAB is going to be universalized, and long-term outcome of bypass graft surgery was proved to be more excellent than balloon dilation or stent insertion. We report our MIDCAB results in 73 patients in the last three years. Material and Method: Retrospective analysis of medical records was done from November 1, 2000 through November 31, 2003. There were 47 males and 26 females ranging in age from 31 years to 79 years (average $61.3\pm9.8$ years). Observation periods after operative procedures were 10 to 1238 days (average $763\pm319.8$ days). Left longitudinal parasternal incision as a standard procedure was done to approach the heart after dissection of the left internal thoracic artery by partial or total resection of 3rd to 5th ribs. Result: Of those patients, 46 patients were transferred to ICU after extubation at operation room and 58 patients were extubated within 3 hours after operation. Average ICU staying periods was $26.8\pm11.5$ hours. Follow-up angiography during admission was done in 36 patients and showed 100% patency. Only one patient died on the 10$^{th}$ post operative day because of sudden CVA. Complications included wound problems in 4 patients, and constructing pericardial window using thoracoscopy due to continuous pericardial effusion in 1. Permanent pacemaker was inserted in one patient owing to sick sinus syndrome. In one patient with recurrence of angina 8 months after operation, stenosis at anastomic site was found and improved with balloon dilatation. Conclusion: We were satisfied with our results of MIDCAB in single and multi-vessel coronary artery disease. These results have made the cardiologists tried to operate positively and we expect widening operative indications including hybrid revascularization.

Fate of Heavy Metals in Activated Sludge: Sorption of Heavy Metal ions by Nocardia amarae

  • Kim, Dong-wook
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 1998.10a
    • /
    • pp.2-4
    • /
    • 1998
  • Proliferation of Nocardia amarae cells in activated sludge has often been associated with the generation of nuisance foams. Despite intense research activities in recent years to examine the causes and control of Nocardia foaming in activated sludge, the foaming continued to persist throughout the activated sludge treatment plants in United States. In addition to causing various operational problems to treatment processes, the presence of Nocardia may have secondary effects on the fate of heavy metals that are not well known. For example, for treatment plants facing more stringent metal removal requirements, potential metal removal by Nocardia cells in foaming activated sludge would be a welcome secondary effect. In contrast, with new viosolid disposal regulations in place (Code o( Federal Regulation No. 503), higher concentration of metals in biosolids from foaming activated sludge could create management problems. The goal of this research was to investigate the metal sorption property of Nocardia amarae cells grown in batch reactors and in chemostat reactors. Specific surface area and metal sorption characteristics of N. amarae cells harvested at various growth stages were compared. Three metals examined in this study were copper, cadmium and nickel. Nocardia amarae strain (SRWTP isolate) used in this study was obtained from the University of California at Berkeley. The pure culture was grown in 4L batch reactor containing mineral salt medium with sodium acetate as the sole carbon source. In order to quantify the sorption of heavy metal ions to N amarae cell surfaces, cells from the batch reactor were harvested, washed, and suspended in 30mL centrifuge tubes. Metal sorption studies were conducted at pH 7.0 and ionlc strength of 10-2M. The sorption Isotherm showed that the cells harvested from the stationary and endogenous growth phase exhibited significantly higher metal sorption capacity than the cells from the exponential phase. The sequence of preferential uptake of metals by N. amarae cells was Cu>Cd>Ni. The specific surFace area of Nocardia cells was determined by a dye adsorption method. N.amarae cells growing at ewponential phase had significantly less specific surface area than that of stationary phase, indicating that the lower metal sorption capacity of Nocardia cells growing at exponential phase may be due to the lower specific surface area. The growth conditions of Nocardia cells in continuous culture affect their cell surface properties, thereby governing the adsorption capacity of heavy metal. The comparison of dye sorption isotherms for Nocardia cells growing at various growth rates revealed that the cell surface area increased with increasing sludge age, indicating that the cell surface area is highly dependent on the steady-state growth rate. The highest specific surface area of 199m21g was obtained from N.amarae cell harvested at 0.33 day-1 of growth rate. This result suggests that growth condition not only alters the structure of Nocardia cell wall but also affects the surface area, thus yielding more binding sites of metal removal. After reaching the steady-state condition at dilution rate, metal adsorption isotherms were used to determine the equilibrium distributions of metals between aqueous and Nocardia cell surfaces. The metal sorption capacity of Nocardia biomass harvested from 0.33 day-1 of growth rate was significantly higher than that of cells harvested from 0.5- and 1-day-1 operation, indicatng that N.amarae cells with a lower growth rate have higher sorpion capacity. This result was in close agreement with the trend observed from the batch study. To evaluate the effect of Nocardia cells on the metal binding capacity of activated sludge, specific surface area and metal sorption capacity of the mixture of Nocardia pure cultures and activated sludge biomass were determined by a series of batch experiments. The higher levels of Nocardia cells in the Nocardia-activated sludge samples resulted in the higher specific surface area, explaining the higher metal sorption sites by the mixed luquor samples containing greater amounts on Nocardia cells. The effect of Nocardia cells on the metal sorption capacity of activated sludge was evaluated by spiking an activated sludge sample with various amounts of pre culture Nocardia cells. The results of the Langmuir isotherm model fitted to the metal sorption by various mixtures of Nocardia and activated sludge indicated that the mixture containing higher Nocardia levels had higher metal adsorption capacity than the mixture containing lower Nocardia levels. At Nocardia levels above 100mg/g VSS, the metal sorption capacity of activate sludge increased proportionally with the amount of Noeardia cells present in the mixed liquor, indicating that the presence of Nocardia may increase the viosorption capacity of activated sludge.

  • PDF