• Title/Summary/Keyword: continuous method

Search Result 5,661, Processing Time 0.034 seconds

Echocardiographic Diagnosis of Pulmonary Arterial Hypertension in Chronic Lung Disease with Hypoxemia (만성 저산소성 폐질환의 폐동맥 고혈압에 대한 심초음파 검사)

  • Chang, Jung-Hyun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.6
    • /
    • pp.846-855
    • /
    • 1999
  • Background : Secondary pulmonary hypertension is an important final endpoint in patients with chronic hypoxic lung disease, accompanied by deterioration of pulmonary hemodynamics. The clinical diagnosis of pulmonary hypertension and/or cor pulmonale could be difficult, and simple noninvasive evaluation of pulmonary artery pressures has been an relevant clinical challenge for many years. Doppler echocardiography might to be a more reliable method for evaluating pulmonary hemodynamics in such patients in terms of the accuracy, reproducibility and easiness for obtaining an appropriate echocardiographic window than M-mode echocardiography. The aim of this study was to assess echocardiographic parameters associated with pulmonary arterial hypertension, defined by increasing right ventricular systolic pressure(RVSP), calculated from trans-tricuspid gradient in patients with chronic hypoxic lungs. Method : We examined 19 patients with chronic hypoxic lung disease, suspected pulmonary hypertension under the clinical guidelines by two dimensional echocardiography via the left parasternal and subcostal approach in a supine position. Doppler echocardiography measured RVSP from tricuspid regurgitant velocity in continuous wave with 2.5MHz transducer and acceleration time(AT) on right ventricular outflow tract in pulsed wave for the estimation of pulmonary arterial pressure. Results : On echocardiography, moderate to severe degree of pulmonary arterial hypertension was defined as RVSP more than 40mmHg, presenting tricuspid regurgitation. Increased right ventricular endsystolic diameter and shortened AT were noted in the increased RVSP group. Increased RVSP was correlated negatively with the shortening of AT. Other clinical data, including pulmonary functional parameters, arterial blood gas analysis and M mode echocardiographic parameters were not changed significantly with the increased RVSP. Conclusion : These findings suggest that shortened AT on pulsed doppler can be useful when quantifying pulmonary arterial pressure with increased RVSP in patients with chronic lung disease with hypoxemia. Doppler echocardiography in pulmonary hypertension of chronic hypoxic lungs is an useful option, based on noninvasiveness under routine clinical practice.

  • PDF

Effect of Oral Healthcare Program of Exemplary Kindergartens for Prevent the Dental Caries in Incheon City, Korea (치아우식증 예방을 위한 모범 유치원 구강건강관리프로그램 효과 - 인천 일부지역 유치원을 중심으로)

  • Ahn, Se-Youn;Hwang, Yoon-Sook;Han, Su-Jin
    • Journal of dental hygiene science
    • /
    • v.13 no.4
    • /
    • pp.501-509
    • /
    • 2013
  • The purpose of the study is to confirm the effect of the oral health management program in exemplary kindergartens for prevent the dental caries. The study performs the survey on the parents about the changes in the oral health behaviors after the oral health education in April 2012 and measures the patient hygiene performance (PHP) index before the education, after the education and 3 weeks after the education to assess the removal capability to plaque on the teeth surface for the children. The analysis is performed on 130 people who join the program and respond the survey. There is no change in the behavior related to the tooth brushing of children after the oral health education. No change is found from the interest in the oral health education (p>0.05) but the recognition in the importance of the tooth positively change, as well as recognition of the tooth brushing method and the reaction to recommending to tooth brushing. The PHP index of children is significantly improved from 3.87 before the education through 2.71 after the education and 3.27 3 weeks after the education (p<0.001). The observation from the patents shows that their children have interest in preventing the cavities including 33.1% after having xylitol and 60.7% after the oral health education. In conclusion, the study confirms the effect of the oral health management program in exemplary kindergartens to prevent the cavities, meaning that it is required to activate the programs and keep implementing the programs including providing xylitol and education for teachers, parents and children to habituate the oral health behavior of the children and completely learn toothbrushing method under continuous management and reeducation.

An Efficient Heuristic for Storage Location Assignment and Reallocation for Products of Different Brands at Internet Shopping Malls for Clothing (의류 인터넷 쇼핑몰에서 브랜드를 고려한 상품 입고 및 재배치 방법 연구)

  • Song, Yong-Uk;Ahn, Byung-Hyuk
    • Journal of Intelligence and Information Systems
    • /
    • v.16 no.2
    • /
    • pp.129-141
    • /
    • 2010
  • An Internet shopping mall for clothing operates a warehouse for packing and shipping products to fulfill its orders. All the products in the warehouse are put into the boxes of same brands and the boxes are stored in a row on shelves equiped in the warehouse. To make picking and managing easy, boxes of the same brands are located side by side on the shelves. When new products arrive to the warehouse for storage, the products of a brand are put into boxes and those boxes are located adjacent to the boxes of the same brand. If there is not enough space for the new coming boxes, however, some boxes of other brands should be moved away and then the new coming boxes are located adjacent in the resultant vacant spaces. We want to minimize the movement of the existing boxes of other brands to another places on the shelves during the warehousing of new coming boxes, while all the boxes of the same brand are kept side by side on the shelves. Firstly, we define the adjacency of boxes by looking the shelves as an one dimensional series of spaces to store boxes, i.e. cells, tagging the series of cells by a series of numbers starting from one, and considering any two boxes stored in the cells to be adjacent to each other if their cell numbers are continuous from one number to the other number. After that, we tried to formulate the problem into an integer programming model to obtain an optimal solution. An integer programming formulation and Branch-and-Bound technique for this problem may not be tractable because it would take too long time to solve the problem considering the number of the cells or boxes in the warehouse and the computing power of the Internet shopping mall. As an alternative approach, we designed a fast heuristic method for this reallocation problem by focusing on just the unused spaces-empty cells-on the shelves, which results in an assignment problem model. In this approach, the new coming boxes are assigned to each empty cells and then those boxes are reorganized so that the boxes of a brand are adjacent to each other. The objective of this new approach is to minimize the movement of the boxes during the reorganization process while keeping the boxes of a brand adjacent to each other. The approach, however, does not ensure the optimality of the solution in terms of the original problem, that is, the problem to minimize the movement of existing boxes while keeping boxes of the same brands adjacent to each other. Even though this heuristic method may produce a suboptimal solution, we could obtain a satisfactory solution within a satisfactory time, which are acceptable by real world experts. In order to justify the quality of the solution by the heuristic approach, we generate 100 problems randomly, in which the number of cells spans from 2,000 to 4,000, solve the problems by both of our heuristic approach and the original integer programming approach using a commercial optimization software package, and then compare the heuristic solutions with their corresponding optimal solutions in terms of solution time and the number of movement of boxes. We also implement our heuristic approach into a storage location assignment system for the Internet shopping mall.

Discounted Cost Model of Condition-Based Maintenance Regarding Cumulative Damage of Armor Units of Rubble-Mound Breakwaters as a Discrete-Time Stochastic Process (경사제 피복재의 누적피해를 이산시간 확률과정으로 고려한 조건기반 유지관리의 할인비용모형)

  • Lee, Cheol-Eung;Park, Dong-Heon
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.29 no.2
    • /
    • pp.109-120
    • /
    • 2017
  • A discounted cost model for preventive maintenance of armor units of rubble-mound breakwaters is mathematically derived by combining the deterioration model based on a discrete-time stochastic process of shock occurrence with the cost model of renewal process together. The discounted cost model of condition-based maintenance proposed in this paper can take into account the nonlinearity of cumulative damage process as well as the discounting effect of cost. By comparing the present results with the previous other results, the verification is carried out satisfactorily. In addition, it is known from the sensitivity analysis on variables related to the model that the more often preventive maintenance should be implemented, the more crucial the level of importance of system is. However, the tendency is shown in reverse as the interest rate is increased. Meanwhile, the present model has been applied to the armor units of rubble-mound breakwaters. The parameters of damage intensity function have been estimated through the time-dependent prediction of the expected cumulative damage level obtained from the sample path method. In particular, it is confirmed that the shock occurrences can be considered to be a discrete-time stochastic process by investigating the effects of uncertainty of the shock occurrences on the expected cumulative damage level with homogeneous Poisson process and doubly stochastic Poisson process that are the continuous-time stochastic processes. It can be also seen that the stochastic process of cumulative damage would depend directly on the design conditions, thus the preventive maintenance would be varied due to those. Finally, the optimal periods and scale for the preventive maintenance of armor units of rubble-mound breakwaters can be quantitatively determined with the failure limits, the levels of importance of structure, and the interest rates.

A Study on the Management Method in Accordance with the Vegetation Structure of Geumgang Pine (Pinus densiflora) Forest in Sogwang-ri, Uljin (울진 소광리 금강소나무림 식생구조 특성에 따른 관리방안)

  • Kim, Dong-Wook;Han, Bong-Ho;Park, Seok-Cheol;Kim, Jong-Yup
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.50 no.1
    • /
    • pp.1-19
    • /
    • 2022
  • The Geumgang Pine (Pinus densiflora) Forest in Sogwang-ri, Uljin has traditionally been a pine tree protection area (prohibited forest) for timber production purposes, and is now designated and managed as a protected area for forest genetic resource conservation by the Korea Forest Service. This study, we analyzed topographical characteristics, existing vegetation, tree age, and plant community structure, and proposed a sustainable management method for the Geumgang Pine (Pinus densiflora) Forest in Sogwang-ri, Uljin for timber havesting purposes. The topographical characteristics of the target area were 36.7% ridges and 38.7% valleys; the ratio of ridges to valleys was similar, and the slopes formed 24.7% of the total area. The types of pine forest communities are divided into six types based on the progress of pine forest renewal, the competition with other species such as deciduous broadleaf trees, and the formation of layered structures. It has been confirmed that the age of the large-diameter pine trees (40~60cm in diameter) is approximately 60~70 years, which is relatively low. As a result of the analysis of the relative importance percentage and layered structure, differences depended on the progress of the pine forest renewal project, and not only the maintenance of the pine forest, but also the creation of a secondary growth forest, the density adjustment of pine trees, and the active management of competitive trees. The average basal area by the community was 12,642.1~25,424.4cm2 for the tree layer and 1.8~1,956.5cm2 for the low tree layer based on a quadrat of 400m2. The difference in the basal area appeared to depend on the size and number of trees forming the tree layer and the degree of pine forest renewal (the degree of time elapsed after thinning pine trees). The average number of species that appeared in each community was 8.7-20.3; there were many species located in valleys, and the type competes with deciduous broadleaf trees due to the lack of management. The diversity of species ranged from 0.6915-1.0942, and was evaluated as low compared to pine communities in central temperate zones. In this paper, we determined the management goals of Geumgang Pine (Pinus densiflora) Forest in Sogwang-ri, Uljin to produce timber with high economic value, and suggested efficient vegetation management for continuous afforestation, the establishment of a timber production system, and improvement of wood production as a management direction.

A study on inspection methods for waste treatment facilities(I): Derivation of impact factor and mass·energy balance in waste treatment facilities (폐기물처리시설의 세부검사방법 마련연구(I): 공정별 주요인자 도출 및 물질·에너지수지 산정)

  • Pul-Eip Lee;Eunhye Kwon;Jun-Ik Son;Jun-Gu Kang;Taewan Jeon;Dong-Jin Lee
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.31 no.1
    • /
    • pp.69-84
    • /
    • 2023
  • Despite the continuous installation and regular inspection of waste treatment facilities, complaints about excessive incineration and illegal dumping stench continue to occur at on-site treatment facilities. In addition, field surveys were conducted on the waste treatment facilities currently in operation (6 type) to understand the waste treatment process for each field, to grasp the main operating factors applied to the inspection. In addition, we calculated the material·energy balance for each main process and confirmed the proper operation of the waste disposal facility. As a result of the site survey, in the case of heat treatment facilities such as incineration, cement kilns, and incineration heat recovery facilities, the main factors are maintenance of the temperature of the incinerator required for incineration and treatment of the generated air pollutants, and in the case of landfill facilities Retaining wall stability, closed landfill leachate and emission control emerged as major factors. In the case of sterilization and crushing facilities, the most important factor is whether or not sterilization is possible (apobacterium inspection).In the case of food distribution waste treatment facilities, retention time and odor control during fermentation (digestion, decomposed) are major factors. Calculation results of material balance and energy resin for each waste treatment facility In the case of incineration facilities, it was confirmed that the amount of flooring materials generated is about 14 % and the amount of scattering materials is about 3 % of the amount of waste input, and that the facility is being operated properly. In addition, among foodwaste facilities, in the case of an anaerobic digestion facility, the amount of biogas generated relative to the amount of inflow is about 17 %, and the biogas conversion efficiency is about 81 %, in the case of composting facility, about 11 % composting of the inflow waste was produced, and it was comfirmend that all were properly operated. As a result, in order to improve the inspection method for waste treatment facilities, it is necessary not only to accumulate quantitative standards for detailed inspection methods, but also to collect operational data for one year at the time of regular inspections of each facility, Grasping the flow and judging whether or not the treatment facility is properly operated. It is then determined that the operation and management efficiency of the treatment facility will increase.

Contaminant Mechanism and Management of Tracksite of Pterosaurs, Birds, and Dinosaurs in Chungmugong-dong, Jinju, Korea (천연기념물 진주 충무공동 익룡·새·공룡발자국 화석산지의 오염물 형성 메커니즘과 관리방안)

  • Myoungju Choie;Sangho Won;Tea Jong Lee;Seong-Joo Lee;Dal-Yong Kong;Myeong Seong Lee
    • Economic and Environmental Geology
    • /
    • v.56 no.6
    • /
    • pp.715-728
    • /
    • 2023
  • Tracksite of pterosaurs, birds, and dinosaurs in Chungmugong-dong in Jinju was designated as a natural monument in 2011 and is known as the world's largest in terms of the number and density of pterosaur footprints. This site has been managed by installing protection buildings to conserve in 2018. About 17% of the footprints of pterosaur, theropod, and ornithopod in this site under management in the 2nd protection building are of great academic value, but observation of footprints has difficulties due to continuous physical and chemical damage. In particular, the accumulation of milk-white contaminants is formed by the gypsum and air pollutant complex. Gypsum remains evaporated with a plate or columnar shape in the process of water circulation around the 2nd protection building, and the dust is from through the inflow of the gallery windows. The aqueous solution of gypsum, consisting of calcium from the lower bed and sulfur from grass growth, is catchmented into the groundwater from the area behind the protection building. Pollen and a few minerals other constituents of contaminants, go through the gallery window, which makes it difficult to expel dust. To conserve the fossil-bearing beds from two contaminants of different origins, controlling the water and atmospheric circulation of the 2nd protection building and removing the contaminants continuously is necessary. When cleaning contaminants, the steam cleaning method is sufficiently effective for powder-shaped milk-white contaminants. The fossil-bearing bed consists of dark gray shale with high laser absorption power; the laser cleaning method accompanies physical loss to fossils and sedimentary structures; therefore, avoiding it as much as possible is desirable.

Exposure Assessments of Environmental Contaminants in Ansim Briquette Fuel Complex, Daegu(II) - Concentration distribution and exposure characteristics of TSP, PM10, PM2.5, and heavy metals - (대구 안심연료단지 환경오염물질 노출 평가(II) - TSP, PM10, PM2.5 및 중금속 농도분포 및 노출특성 -)

  • Jung, Jong-Hyeon;Phee, Young-Gyu;Lee, Jun-Jung;Oh, In-Bo;Shon, Byung-Hyun;Lee, Hyung-Don;Yoon, Mi-Ra;Kim, Geun-Bae;Yu, Seung-do;Min, Young-Sun;Lee, Kwan;Lim, Hyun-Sul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.3
    • /
    • pp.380-391
    • /
    • 2015
  • Objectives: The objective of this study is to assess airborne particulate matter pollution and its effect on health of residents living near Ansim Briquette Fuel Complex and its vicinities. Also, this study measured and analyzed the concentration of TSP, $PM_{10}$, $PM_{2.5}$, and heavy metals which influences on the environmental and respiratory disease in Ansim Briquette Fuel Complex, Daegu, Korea. Methods: In this study, we analyzed various environmental pollutants such as particulate matter and heavy metals from Ansim Briquette Fuel Complex that adversely affected local residents's health. In particular, we verified the concentration distribution and characteristics of exposure for TSP, $PM_{10}$, and $PM_{2.5}$ among particulate matters, and heavy metals(Cd, Cr, Cu, Mn, Ni, Pb, Fe, Zn, and Mg). In that regard, the official test method on air pollution in Korea for analysis of particulate matter and heavy metal in atmosphere were conducted. The large capacity air sampling method by the official test method on air pollution in Korea were applied for sampling of heavy metals in atmosphere. In addition, we evaluated the concentration of seasonal environmental pollutants for each point of residence in Ansim Briquette Fuel Complex and surrounding area. The sampling measured periods for air pollutants were from August 11, 2013 to February 21, 2014. Furthermore, we measured and analyzed the seasonal concentrations(summer, autumn and winter). Results: The average concentration for TSP, $PM_{10}$, and $PM_{2.5}$ by direct influence area at Ansim Briquette Fuel Complex were 1.7, 1.4 and 1.9 times higher than reference region. In analysis results of seasonal concentrations for particulate matter in four direct influence and reference area, concentration levels for winter were generally somewhat higher than concentrations for summer and autumn. The average concentrations for Cd, Cr, Mn, Ni, Pb, Fe, and Zn in direct influence area at Ansim Briquette Fuel Complex were $0.0008{\pm}0.0004{\mu}g/Sm^3$, $0.0141{\pm}0.0163{\mu}g/Sm^3$, $0.0248{\pm}0.0059{\mu}g/Sm^3$, $0.0026{\pm}0.0011{\mu}g/Sm^3$, $0.0272{\pm}0.0084{\mu}g/Sm^3$, $0.4855{\pm}0.1862{\mu}g/Sm^3$, and $0.3068{\pm}0.0631{\mu}g/Sm^3$, respectively. In particularly, the average concentrations for Cd, Cr, Mn, Ni, Pb, Fe, and Zn in direct influence area at Ansim Briquette Fuel Complex were 1.9, 3.6, 2.1, 1.9, 1.4, 2.6, and 1.2 times higher than reference area, respectively. The continuous monitoring and management were required for some heavy metals such as Cr and Ni. Moreover, the average concentration in winter for particulate matter in direct influence area at Ansim Briquette Fuel Complex were generally higher than concentrations in summer and autumn. Also, average concentrations for TSP, $PM_{10}$, and $PM_{2.5}$ were from 1.5 to 2.0 times, 1.2 to 1.8 times, and 1.1 to 2.3 times higher than reference area, respectively. In results for seasonal atmospheric environment, TSP, $PM_{10}$, $PM_{2.5}$, and heavy metal concentrations in direct influence area were higher than reference area. Especially, the concentrations in C station were a high level in comparison with other area. Conclusions: In the results, some particulate matters and heavy metals were relatively high concentration, in order to understand the environmental pollution level and health effect in surrounding area at Ansim Briquette Fuel Complex. The concentration of some heavy metals emitted from direct influence area at Ansim Briquette Fuel Complex were relatively higher than reference area. In particular, average concentration for heavy metals in this study were higher than average concentrations in air quality monitoring station for heavy metal for 7 years in Deagu metropolitan region. Especially, the residents near Ansim Briquette Fuel Complex may be exposed to the pollutants(TSP, $PM_{10}$, $PM_{2.5}$, and heavy metals, etc) emitted from the factories in Ansim Briquette Fuel Complex.

Study on PM10, PM2.5 Reduction Effects and Measurement Method of Vegetation Bio-Filters System in Multi-Use Facility (다중이용시설 내 식생바이오필터 시스템의 PM10, PM2.5 저감효과 및 측정방법에 대한 연구)

  • Kim, Tae-Han;Choi, Boo-Hun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.48 no.5
    • /
    • pp.80-88
    • /
    • 2020
  • With the issuance of one-week fine dust emergency reduction measures in March 2019, the public's anxiety about fine dust is increasingly growing. In order to assess the application of air purifying plant-based bio-filters to public facilities, this study presented a method for measuring pollutant reduction effects by creating an indoor environment for continuous discharge of particle pollutants and conducted basic studies to verify whether indoor air quality has improved through the system. In this study conducted in a lecture room in spring, the background concentration was created by using mosquito repellent incense as a pollutant one hour before monitoring. Then, according to the schedule, the fine dust reduction capacity was monitored by irrigating for two hours and venting air for one hour. PM10, PM2.5, and temperature & humidity sensors were installed two meters front of the bio-filters, and velocity probes were installed at the center of the three air vents to conduct time-series monitoring. The average face velocity of three air vents set up in the bio-filter was 0.38±0.16 m/s. Total air-conditioning air volume was calculated at 776.89±320.16㎥/h by applying an air vent area of 0.29m×0.65m after deducing damper area. With the system in operation, average temperature and average relative humidity were maintained at 21.5-22.3℃, and 63.79-73.6%, respectively, which indicates that it satisfies temperature and humidity range of various conditions of preceding studies. When the effects of raising relatively humidity rapidly by operating system's air-conditioning function are used efficiently, it would be possible to reduce indoor fine dust and maintain appropriate relative humidity seasonally. Concentration of fine dust increased the same in all cycles before operating the bio-filter system. After operating the system, in cycle 1 blast section (C-1, β=-3.83, β=-2.45), particulate matters (PM10) were lowered by up to 28.8% or 560.3㎍/㎥ and fine particulate matters (PM2.5) were reduced by up to 28.0% or 350.0㎍/㎥. Then, the concentration of find dust (PM10, PM2.5) was reduced by up to 32.6% or 647.0㎍/㎥ and 32.4% or 401.3㎍/㎥ respectively through reduction in cycle 2 blast section (C-2, β=-5.50, β=-3.30) and up to 30.8% or 732.7㎍/㎥ and 31.0% or 459.3㎍/㎥ respectively through reduction in cycle 3 blast section (C-3, β=5.48, β=-3.51). By referring to standards and regulations related to the installation of vegetation bio-filters in public facilities, this study provided plans on how to set up objective performance evaluation environment. By doing so, it was possible to create monitoring infrastructure more objective than a regular lecture room environment and secure relatively reliable data.

A Clinical Evaluation of Splanchnic Nerve Block (내장신경차단에 관한 임상적 연구)

  • Kim, Soo-Yeoun;Oh, Hung-Kun;Yoon, Duek-Mi;Shin, Yang-Sik;Lee, Youn-Woo;Kim, Jong-Rae
    • The Korean Journal of Pain
    • /
    • v.1 no.1
    • /
    • pp.34-46
    • /
    • 1988
  • Intractable pain from advanced carcinoma of the upper abdomen is difficult to manage. One method used to control pain associated with these malignancies is to block off the splanchnic nerve. In 1919 Kappis described a technique by which the splanchnic nerve of the upper abdomen could be anesthetized, using a percutaneous injection. This method has been used for the relief of upper abdominal pain due to hematoma and cancer of the pancreas, stomach, gall bladder, bile duct, and colon. During the Period from November 1968 to January 1986, this method was used in 208 cases of malignancy at Severance Hospital and clinically evaluated. Patients were retroactively grouped according to the stage of development of technique used. Twelve patients who received the treatment in the period from November 1968 to March 1977 were designate4i as group 1, 26 patients from April 1977 to April 1979 as group 2, and 170 from May 1979 to January 1986 as group 3. The results are as follows: 1) The number of patients receiving splanchnic nerve block has been increasing since 1977. 2) A total of 208 patients, including 133 males and 75 females, ranging in age from 18 to 84 and averaging 51. 3) The causes of pain were stomach cancer 90, pancreatic cancer 69, and miscellaneous cancer 49 cases respectively. 4) There were 57.7% who had surgery. and 3.7% of whom had chemotherapy before the splanchnic nerve block was done. 5) These blocks were carried out with the patient in the prone position as described by Dr. Moore. For group 2 and 3, C-arm image intensifier was used. In group 1, a 22 gauze loom long needle was inserted at the lower border of the 12th rib on each aide about 7\;cm from the midline. The average distance from the midline was $6.60{\pm}0.61\;cm$ on the left side and $6.60{\pm}0.83\;cm$ on the right side in group 2, and $5.46{\pm}0.76\;cm$ on the left side and $5.49{\pm}0.69\;cm$ on the right side in group 3. The average depth to which the needle was inserted was $8.60{\pm}0.52\;cm$ on the left side and $8.74{\pm}0.60\;cm$ on the right side in group 2, and $8.96{\pm}0.63\;cm$ on the left side and $9.18{\pm}0.57\;cm$ on the right side in group 3. 6) The points of the inserted needles were positioned in the upper quarter anteriorly, 51.8% on the left side and 54.4% n the right side of the L1 vertebra by lateral roentgenogram in group 3. The inserted needle points were located in the upper and anterolateral part, of the L1 vertebra 68.5% on the left side and 60.6won the right side, on the anteroposterior rentgenogram in group 3. The needle tip was not advanced beyond the anterior margin of the vertebral body. 7) In some case of group 3, contrast media was injected before the block was done. It shows, the spread upward along the anterior mal gin of the vertebral body. 8) The concentration and the average amount of drug used in each group was as follows: In group 1, $39.17{\pm}6.69\;ml$ of 0.5% -l% lidocaine or 0.25% bupivacaine were injected for the test block and one to three days after the test block $40.00{\pm}4.26\;ml$ of 50% alcohol was injected for the semipermanent block. In group 2, $13.75{\pm}4.88\;ml$ of 1% lidocaine were used as the test block and followed by $46.17{\pm}4.37\;ml$ of 50% alcohol was injected as the semipermanent block. In group 3, $15.63{\pm}1.19\;ml$ of 1% lidocaine for test block followed by $15.62{\pm}1.20\;ml$ of pure alcohol and $16.05{\pm}2.58\;ml$ of 50% alcohol for semipermanent block were injected. 9) The result of the test block was satisfactory in all cases. However the semipermanent block was 83.3 percent of the patients in group 1 who received relief from pain for at least 2 weeks after the block, 73.1% in group 2, and 91.8% in group 3. In these unsuccessful cases, 2 cases in group 1 were controlled by narcotics but 7 cases in group 2 and 14 cases in group 3 received the same splanchnic nerve block 1 or 2 times again within 2 weeks. But, in some cases it was 3 to i months before the 2nd block and in 1 cases even 7 years. 10) The most common complications of splanchnic nerve block were hypotensino(25.5%) occasional flushing of the face, nausea, vomiting, and chest discomfort. 11) For the patients in group 3, the supplemental block most commonly used was a continuous epidural block; it was used as a diagnostic block and to afford relief from pain before the splanchnic nerve block was done. 12) The interval between the receiving of the alcohol block and discharge was from 5 to 8 days in 61 cases(31.1%) and from 1 to 2 days in 48 cases(24.5%). From the above results, it can be concluded that the splanchnic nerve block done in the prone position with pure and 50% alcohol immediately after an effective test block with 1% lidocaine under C-arm fluoroscopic control is satisfactory and reliable. How to minimize the repeat block is still a problem to be solved.

  • PDF