• Title/Summary/Keyword: continuous method

Search Result 5,663, Processing Time 0.033 seconds

Continuous relaxation spectrum for the numerical analysis of concrete creep

  • Zi, Goang-Seup
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.466-471
    • /
    • 2004
  • Efficient numerical finite element analysis of creeping concrete structures requires the use Kelvin or Maxwell chain model, which is most conveniently identified from a continuous retardation or relaxation spectrum, the spectrum in turn being determined from the given compliance or relaxation function. The method of doing that within the context of solidification theory for creep with aging was previously worked out by Bazant and Xi, but only for the case of a continuous retardation spectrum based on Kelvin chain. The present paper is motivated by the need to incorporate concrete creep into the recently published microplane model M4 for nonlinear triaxial behavior of concrete, including tensile fracturing and behavior under compression. In that context. the Maxwell chain is more effective than Kelvin chain. because of the kinematic constraint of the microplanes used in M4. Determination of the continuous relaxation spectrum for Maxwell chain. based on the solidification theory, is outlined and numerical examples are presented.

  • PDF

Characteristics of Indium-Tin-Oxide Electrode for Continuous-flow PCR Chip (연속흐름 중합효소연쇄반응칩 제작을 위한 인듐 산화막 전극의 특성분석)

  • Joung, Seung-Ryong;Kim, Jun-Hyeok;Yi, In-Je;Kang, C.J.;Kim, Yong-Sang
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.3
    • /
    • pp.561-565
    • /
    • 2007
  • We propose glass and PDMS (polydimethylsiloxane) chips for DNA amplification with continuous-flow PCR (polymerase chain reaction). The PDMS microchannel was fabricated using a negative molding method for sample injection. Three heaters and sensors of ITO (indium-tin-oxide) thin films were fabricated on glass chip. ITO heaters and sensors were calibrated accurately for the temperature control of the liquid flow. ITO heater generated stable heat versus applied power. ITO sensor resistance was changed linearly versus temperature increase as a RTD (resistance temperature detector) sensor. As a result, we enable precision temperature control of continuous-flow PCR chip. Using the continuous-flow PCR chip DNA plasmid pKS-GFP 720 bp was successfully amplified.

Design of Continuous Sterilizer for Retort Pouch (레토르트용 연속 살균기의 개발)

  • Park, Cheol-Jae
    • Journal of Power System Engineering
    • /
    • v.19 no.2
    • /
    • pp.57-63
    • /
    • 2015
  • In this paper, we developed a continuous sterilizer in order to improve the productivity of the retort product. To this end, we design the sterilizer with a product inlet, outlet, and chain for continuously conveying the retort. The temperature analysis is performed to optimize the design parameters of the internal sterilizer. The experimental apparatus is developed to verify the productivity of the sterilizer based on the temperature analysis. The test is performed to optimize the evaluation parameters using Box-Behnken design method of a response surface methodology. From the test, the productivity of the continuous sterilizer is improved over 1,000 kg/h.

A Case Study of Continuous Improvement Methodology by Calculated Quality-Cost (품질비용 산정에 의한 지속적 개선 방법 사례 연구)

  • Lee, Kang-In;Han, Seok-Man
    • Journal of Korean Society for Quality Management
    • /
    • v.33 no.3
    • /
    • pp.19-30
    • /
    • 2005
  • Recently many organization to become survival in changing marketplace, they must commit to implementing tools, systems, and quality management techniques. In this paper we develop process method of Team's problem-solving to reduce in failure costs. This paper suggest the step process how to measure quality cost reasonably that works in all types organizations. Or what is continuous improvement? Continuous improvement can be described as the continuous reduction of variation. Variation has many sources(machines, methods, materials, measurements, people, and environments) and cause(special & common in organization). As quality cost are not the answer to every organization financial, or quality-related problem, it's real results are designing & implementing quality cost system might be the answer.

Analysis of Aluminum Powder Densification by Continuous Front Extrusion-Equal Channel Angular Pressing (등통로각압축이 결합된 압출 공정에 의한 알루미늄 분말의 치밀화 거동)

  • Yoon, Seung-Chae;Kim, Hyoung-Seop
    • Journal of Powder Materials
    • /
    • v.15 no.3
    • /
    • pp.204-209
    • /
    • 2008
  • Aluminum alloys are not only lightweight materials, but also have excellent thermal conductivity, electrical conductivity and workability, hence, they are widely used in industry. It is important to control and enhance the densification behavior of metal powders of aluminum. Investigation on the extrusion processing combined with equal channel angular pressing for densification of aluminum powders was performed in order to develop a continuous production process. The continuous processing achieved high effective strain and full relative density at $200^{\circ}C$. Optimum processing conditions were suggested for good mechanical properties. The results of this simulation helped to understand the distribution of relative density and effective strain.

Continuous Lumbar Epidural Analgesia for Labor and Vaginal Delivery in Epileptic Pregnant Women (간질이 있는 산모에서 간질의 예방 및 분만통 감소를 위한 경막외 진통의 경험 1예 -증례 보고-)

  • Choi, So-Yong;Rim, Sung-Jin;Lee, Jung-Tae
    • The Korean Journal of Pain
    • /
    • v.11 no.2
    • /
    • pp.332-334
    • /
    • 1998
  • A 25-year-old epileptic female patient scheduled for vaginal delivery, was referred to the pain clinic for the relief of labor pain. She had been taking anticonvulsant drugs, but suffered from seizure attacks three or four times a month. We had induced continuous lumbar epidural analgesia successfully and she subsequently gave birth to a healthy infant. So we report that continuous lumbar epidural analgesia should be considered as a safe method for reduction of labor pain and prevention of seizure attacks in epileptic pregnant women.

  • PDF

Alternative Derivation of Continuous-Time Model for Current-Mode Control (전류모드제어를 위한 연속시간모델의 새로운 유도 방법)

  • 정동열;홍성수;최병조;안현식;사공석진
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.2
    • /
    • pp.137-142
    • /
    • 2003
  • Two existing continuous-time models for the current-mode control have presented noticeable differences in their small-signal predictions. As an attempt to clarify the origin of these disparities, this paper presents an alternative way of deriving a continuous-time model for the current-model control. The results of this paper would provide insights to comprehend the dissimilarity in the modeling method and final results of the earlier models of current-mode control models.

Development of Continuous/Discrete Mixed $H_2$/H$\infty$ Filtering Design Algorithms for Time Delay Systems

  • Kim, Jong-Hae
    • Transactions on Control, Automation and Systems Engineering
    • /
    • v.2 no.3
    • /
    • pp.163-168
    • /
    • 2000
  • The problems of mixed $H_2/H_{\infty}$ filtering design fer continuous and discrete time linear systems with time delay are investigated. The main purpose is to design a stable mixed $H_2/H_{\infty}$ filter which minimizes the H$_2$Performance measure satisfying a prescribed H$_{\infty}$ norm bound on the closed loop system in continuous-time case and discrete-time case, respectively. The sufficient conditions of existence of filter, the mixed $H_2/H_{\infty}$ filter design method, and the upper bound of performance measure are proposed by LMI(linear matrix inequality) techniques in terms of all finding variables. Also, we present optimization problems in order to get the optimal mixed $H_2/H_{\infty}$ filter in continuous and discrete time case, respectively.

  • PDF

Combinatorial continuous non-stationary critical excitation in M.D.O.F structures using multi-peak envelope functions

  • Ghasemi, S. Hooman;Ashtari, P.
    • Earthquakes and Structures
    • /
    • v.7 no.6
    • /
    • pp.895-908
    • /
    • 2014
  • The main objective of critical excitation methods is to reveal the worst possible response of structures. This goal is accomplished by considering the uncertainties of ground motion, which is subjected to the appropriate constraints, such as earthquake power and intensity limit. The concentration of this current study is on the theoretical optimization aspect, as is the case with the majority of conventional critical excitation methods. However, these previous studies on critical excitation lead to a discontinuous power spectral density (PSD). This paper introduces some critical excitations which contain proper continuity in frequency domain. The main idea for generating such continuous excitations stems from the combination of two continuous functions. On the other hand, in order to provide a non-stationary model, this paper attempts to present an appropriate envelope function, which unlike the previous envelope functions, can properly cover the natural earthquakes' accelerograms based on multi-peak conditions. Finally, the proposed method is developed into the multiple-degree-of-freedom (M.D.O.F) structures.

On-line parameter estimation of continuous-time systems using a genetic algorithm (유전알고리즘을 이용한 연속시스템의 온라인 퍼래미터 추정)

  • Lee, Hyeon-Sik;Jin, Gang-Gyu
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.4 no.1
    • /
    • pp.76-81
    • /
    • 1998
  • This paper presents an on-line scheme for parameter estimation of continuous-time systems, based on the model adjustment technique and the genetic algorithm technique. To deal with the initialisation and unmeasurable signal problems in on-line parameter estimation of continuous-time systems, a discrete-time model is obtained for the linear differential equation model and approximations of unmeasurable states with the observable output and its time-delayed values are obtained for the nonlinear state space model. Noisy observations may affect these approximation processes and degrade the estimation performance. A digital prefilter is therefore incorporated to avoid direct approximations of system derivatives from possible noisy observations. The parameters of both the model and the designed filter are adjusted on-line by a genetic algorithm, A set of simulation works for linear and nonlinear systems is carried out to demonstrate the effectiveness of the proposed method.

  • PDF