• 제목/요약/키워드: continuous method

Search Result 5,663, Processing Time 0.03 seconds

$LiNbO_{3}$ single crystal growth by the continuous growth method (Orrms method) : (I) On the growth process (연속성장법(Orrms method)에 의한 $LiNbO_{3}$ 단결정 성장 : (I) 결정성장을 중심으로)

  • Joo, Kyung;Auh, Keun-Ho
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.6 no.3
    • /
    • pp.293-300
    • /
    • 1996
  • A continuous growth method (Orr's method) were developed to grow LiNbO3 single crystals. The optimum growth condition established are as follows; When the controlled temperature of a platinum crucible were 1190℃∼1210℃, the pulling rate was 2 mm/hr, the feeding rate was 1.5∼2.5 g/hr, and the rotation speed was 20 rpm. The phase and growth orientation of the grown LiNbO3 crystals wer characterized by a X-ray diffraction method. The overflowing phenomena, which induced cracking into the grown crystal during the process, was effectively suppressed by the control of the growth parameter.

  • PDF

Barycentric Approximator for Reinforcement Learning Control

  • Whang Cho
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.3 no.1
    • /
    • pp.33-42
    • /
    • 2002
  • Recently, various experiments to apply reinforcement learning method to the self-learning intelligent control of continuous dynamic system have been reported in the machine learning related research community. The reports have produced mixed results of some successes and some failures, and show that the success of reinforcement learning method in application to the intelligent control of continuous control systems depends on the ability to combine proper function approximation method with temporal difference methods such as Q-learning and value iteration. One of the difficulties in using function approximation method in connection with temporal difference method is the absence of guarantee for the convergence of the algorithm. This paper provides a proof of convergence of a particular function approximation method based on \"barycentric interpolator\" which is known to be computationally more efficient than multilinear interpolation .

A study on application techniques in design phase of applying a crossing stacking method of modular housing (모듈러 저층집합주거의 교차적층방식 설계 적용기술 연구)

  • Jun, Young-Hun;Lee, Young;Kim, Kyoon-Tai
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.81-82
    • /
    • 2014
  • Modular housing has many advantages such as economy, flexibility and reusability. The domestic modular housing of a continuous stacking method has been built in military facilities, and dormitories. However, there is a limit to present diversity of low-rise multi-family housing. A cross stacking method is a way to pursue diversity of that but there is a difficulty to apply it owe to lack of cases and related technologies. Therefore, the purpose of this study is to suggest application techniques in design phase of applying the crossing stacking method in advance.

  • PDF

DEVELOPMENT OF A NUMERICAL TECHNIQUE FOR CAPILLARY SPREADING OF A DROPLET CONTAINING PARTICLES ON THE SOLID SUBSTRATE (미세입자분산 액적의 고체면에서 모세퍼짐 현상에 관한 직접수치해석 기법개발)

  • Hwang, Wook-Ryol;Jeong, Hyun-Jun;Kim, See-Jo;Kim, Chong-Youp
    • Journal of computational fluids engineering
    • /
    • v.12 no.4
    • /
    • pp.14-19
    • /
    • 2007
  • We present a direct numerical simulation technique and some preliminary results of the capillary spreading of a droplet containing particles on the solid substrate. We used the level-set method with the continuous surface stress for description of droplet spreading with interfacial tension and employed the discontinuous Galerkin method for the stabilization of the interface advection equation. The distributed Lagrangian-multipliers method has been combined for the implicit treatment of rigid particles. We investigated the droplet spreading by the capillary force and discussed effects of the presence of particles on the spreading behavior. It has been observed that a particulate drop spreads less than the pure liquid drop. The amount of spread of a particulate drop has been found smaller than that of the liquid with effectively the same viscosity as the particulate drop.

A comparative study of ultra-trace-level uranium by thermal ionization mass spectrometry with continuous heating: Static and peak-jumping modes

  • Lee, Chi-Gyu;Park, Ranhee;Park, Jinkyu;Lim, Sang Ho
    • Nuclear Engineering and Technology
    • /
    • v.52 no.7
    • /
    • pp.1532-1536
    • /
    • 2020
  • For ensuring nuclear safeguards, we report the analytical signal-detection performance of thermal ionization mass spectrometry (TIMS) with continuous heating for the measurement of isotopic ratios in samples containing ultra-trace amounts of uranium. As methods for detecting uranium signals, peak-jumping mode using a single detector and static mode using multiple detectors were examined with U100 (10% 235U-enriched) uranium standard samples in the femtogram-to-picogram range. Uranium isotope ratios, n(235U)/n(238U), were measured down to levels of 1 fg and 3 fg in static and peak-jumping modes, respectively, while n(234U)/n(238U) and n(236U)/n(238U) values were measured down to levels of 100 fg in both modes. In addition, the dependency of the 238U signal intensity on sample quantity exhibited similar tendencies in both modes. The precisions of the isotope ratios obtained in the static mode over all sample ranges used in this study were overall slightly higher than those obtained in peak-jumping mode. These results indicate that isotope ratio measurements by TIMS with continuous heating are almost independent of the detection method, i.e., peak-jumping mode or static mode, which is characteristic of isotope-ratio measurements using the TIMS method with continuous heating. TIMS with continuous heating is advantageous as it exhibits the properties of multiple detectors within a single detector, and is expected to be used in various fields in addition to ensuring nuclear safeguards.

A Study on Teaching Continuous Probability Distribution in Terms of Mathematical Connection (수학적 연결성을 고려한 연속확률분포단원의 지도방안 연구)

  • Hwang, Suk-Geun;Yoon, Jeong-Ho
    • School Mathematics
    • /
    • v.13 no.3
    • /
    • pp.423-446
    • /
    • 2011
  • In school mathematics, concepts of definite integral and integration by substitution have mathematical connection with introduction of probability density function, expectation of continuous random variable, and standardization of normal distribution. However, we have difficulty in finding mathematical connection between integration and continuous probability distribution in the curriculum manual, 13 kinds of 'Basic Calculus and Statistics' and 10 kinds of 'Integration and Statistics' authorized textbooks, and activity books applied to the revised curriculum. Therefore, the purpose of this study is to provide a teaching method connected with mathematical concepts of integral in regard to three concepts in continuous probability distribution chapter-introduction of probability density function, expectation of continuous random variable, and standardization of normal distribution. To find mathematical connection between these three concepts and integral, we analyze a survey of student, the revised curriculum manual, authorized textbooks, and activity books as well as 13 domestic and 22 international statistics (or probability) books. Developed teaching method was applied to actual classes after discussion with a professional group. Through these steps, we propose the result by making suggestions to revise curriculum or change the contents of textbook.

  • PDF

Composite estimation type weighting adjustment for bias reduction of non-continuous response group in panel survey (패널조사에서 비연속 응답 그룹 편향 보정을 위한 복합가중값)

  • Choi, Hyunga;Kim, Youngwon
    • The Korean Journal of Applied Statistics
    • /
    • v.32 no.3
    • /
    • pp.375-389
    • /
    • 2019
  • Sample attrition according to a long-term tracking reduces the representativeness of the sample data in a panel study. Most panel surveys in South Korea and other countries have prepared response adjustment weights in order to solve problems regarding representativeness due to sample attrition. In this paper, we divided the panel data into continuous response group and non-continuous response group according to response patterns and considered a weighting adjustment method to reduce the bias of the non-continuous response group. A simulation indicated that the proposed composite estimation type weighting method, which reflected the characteristics of non-continuous response groups, could be more efficient than other weighting methods in terms of reducing non-response bias. As a case study, the proposed methods are applied to the Korean Longitudinal Study of Ageing (KLoSA) data of the Korea Employment Information Service.

Analysis on the Importance and Competitiveness of Support Services of the Food Service Franchise Headquarters AHP Technique (AHP를 이용한 외식프랜차이즈 가맹본부의 지원서비스의 중요도 및 경쟁력 분석)

  • CHOI, Chaebong;LEE, Sang-Suk
    • The Korean Journal of Franchise Management
    • /
    • v.10 no.4
    • /
    • pp.7-18
    • /
    • 2019
  • Purpose: This study identifies the relative importance of the sub - factors of initial services and continuous services using AHP (Analytic Hierarchy Process) method, and calculates the competitive index for the detailed factors. The purpose of this paper is to propose the establishment of long - term and short - term management strategy for expansion of business of food service franchise, franchisors, long - term and win - win relationship with franchisees, and rationalization of operating system. Research design, data, and methodology: The population for the survey is 92 franchisees in 46 foreign brands and 46 domestic brands in the Seoul metropolitan area (Seoul / Gyeonggi / Incheon). The survey was conducted from July 1 to August 31, 2018 through the survey agency with a telephone interview and a surveyor's direct visit. A total of 100 questionnaires were collected, but a total of 92 parts were used for analysis except 8 parts that were considered to contain false information. Using the AHP method, relative importance and competitiveness index were calculated for the details of initial services and continuous services. Results: The results shows continuous services were significantly higher for both foreign brand franchises, domestic brand franchises, and overall than initial services, This suggests that the continuous services of the affiliated franchisors has a higher relative importance than the initial services. Among the continuous services, brand reinforcement and promotion were significantly higher for both foreign brand merchants and domestic brand franchises. This can be regarded as the most important factor in brand reinforcement and promotion when selecting a food service franchisors. Conclusions: In the Standard Terms and Conditions governed by the Fair Trade Commission, the franchisors should increase the fairness by creating manuals for supporting services, especially after opening, and regularly checking whether the supporting services have been carried out like manuals since the establishment of franchisees. In addition, the Brand Strengthening and Public Relations Committee (tentative name) jointly participated by the franchisors and franchisees for the purpose of strengthening and promoting the brand, suggesting a system for transparent and efficient execution of the brand reinforcement and promotion budget and monitoring afterwards.

Unified calculation model for the longitudinal fundamental frequency of continuous rigid frame bridge

  • Zhou, Yongjun;Zhao, Yu;Liu, Jiang;Jing, Yuan
    • Structural Engineering and Mechanics
    • /
    • v.77 no.3
    • /
    • pp.343-354
    • /
    • 2021
  • The frequencies formulas of the bridge are of great importance in the design process since these formulas provide insight dynamic characteristics of the structure, which guides the designers to parametric analyses and the layout of the bridge in conceptual or preliminary design. Continuous rigid frame bridge is popular in the mountainous area. Mostly, this type of bridge was simplified either as a girder or cantilever when calculating the frequency, however, studies showed that the different configuration of the bridge made the problem more complex, and there is no unified fundamental calculation pattern for this kind of bridge. In this study, an empirical frequency equation is proposed as a function of pier's height, stiffness of pier and the weight of the structure. A unified fundamental frequency formula is presented based on the energy principle, then the typical continuous rigid frame bridge is investigated by finite element method (FEM) to study the dynamic characteristics of the structure, and then several key parameters are investigated on the effect of structural frequency. These parameters include the number, position and stiffness of the tie beam. Nonlinear regression analyses are conducted with a comprehensive statistical study from plenty of engineering structures. Finally, the proposed frequency equation is validated by field test results. The results show that the fundamental frequency of the continuous rigid frame bridge increases more than 15% when the tie beams are set, and it increases with the stiffness ratio of tie beam to pier. The results also show that the presented unified fundamental frequency has an error of 4.6% compared with the measured results. The investigation can predicate the approximate longitudinal fundamental frequency of continuous ridged frame bridge, which can provide reference for the seismic response and dynamic impact factor design of the pier.

Experimental Study of the Anastomosis with Suture vs Non-suture Techinique (미세 혈관 접합술에서 봉합적 수기와 비봉합적 수기의 실험적 비교 연구)

  • Chung, Duke-Whan;Han, Chung-Soo;Yoo, Myung-Chul;Nam, Gi-Un;Sun, Seung-Deok
    • Archives of Reconstructive Microsurgery
    • /
    • v.3 no.1
    • /
    • pp.45-53
    • /
    • 1994
  • Suture microvascular anastomosis is time-consuming and tedious and demands long and continuous training. Techinique of anastomosis of microvessel was presented interrupted suture and continuous suture. Recently the unilink instrument system is created as a fast and simple method to achieve high patency rates without long and continuous training in the anastomosis of small vessels. The author experimentally studied the femoral artery of 20 mice(0.5-1.0mm, av. 0.7mm), the femoral vein of 20 mice(0.8-1.6mm, av. 1.2mm) after anastomosis with interrupted suture in 20 cases and continuous sutre in 20 cases. For the unilink apparatus we used the carotid arteries of 15 cases in 14 rabbits(1.0-1.6mm, av. 1.3mm) and facial veins of 12 cases in 14 rabbits(0.9mm-2.2mm, av. 1.5mm). A total of 27 arterial and venous anastomoses were performed. We examined the postoperative patency at immediate, 2 weeks, and 8 weeks. The results were as followings, 1. In the arterial anastomosis the rate of patency was 90%(18/20) in interrupted suture, 90%(18/20) in continuous suture and 93%(13/15) in unilink apparatus. In the venous anastomosis the rate of patency was 90%(18/20) in interrupted suture, 80%(16/20) in continuous suture and 100%(9/9) in unilink apparatus. 2. The mean time for completion of the arterial anastomosis were 12.2 minutes in interrupted suture group, 10.3 minutes in continouous suture group and 8.5 minutes in unillnk apparatus group. The mean time for completion of the venous anastomosis were 13.6 minutes in interrupted suture group, 11.0 minutes in continuous suture group and 6.2 minutes in unilink apparatus group. 3. At the histological examination of suture group, hyperplastic reaction of middle layer and subintimal hyperplasia were observed. In unilink apparatus group, the endothelium layer was continued and the thickness of vessel wall was decreased due to moderate atrophy of the media and mild degree of nonspecific chronic inflammation were seen around the unilink apparatus. 4. No significants was noticied in foreign body reaction among the interrupted, continuous and unilink apparatus group. 5. A case of the arterial anastomosis was released with acting out at 15 minutes after operation. 6. The important factors in the technical problems were accurate apposition of the cut vessel edges in suture group and the proper selection of the ring size and optimal fitting between two rings in unilink apparatus group. Even though the outer diamater of vessel in suture group was different from that in unilink apparatus group the unilink method provides a very safe, fast, and simple way to perform microvascular anastomoses especially in anastomosis of vein. But howerver suture was needed in vessels below 1 mm outer diamater. In that situation continuous suture was benefit than the interrupted suture in operation time.

  • PDF