• Title/Summary/Keyword: continuous flow-through system

Search Result 139, Processing Time 0.031 seconds

Acute toxicity of hydrogen sulfide to larvae and adults of blue crab Portunus trituberculatus white shrimp Metapenaeus monoceros and prawn Macrobrachium nipponens (꽃게, 중하 및 징거미새우의 유생과 성체에 대한 황화수소의 급성독성)

  • Kang, Ju-Chan
    • Journal of fish pathology
    • /
    • v.10 no.1
    • /
    • pp.65-72
    • /
    • 1997
  • In the present study, acute toxicity data were obtained for hydrogen sulfide to larvae and adults of blue crab Portunus trituberculatus, white shrimp Metapenacus monoceros and prawn Macrobrachium nipponense under continuous flow through system. The larvae 96hr-$LC_{50}$ values of hydrogen sulfide were 7.3, 9.3 and $9.0{\mu}g/\ell$ for P. trituberculatus, M. monoceros and M. nipponense respectively. The larval sensitivity of the three crustaceans studied for the hydrogen sulfide was in the order of P. trituberculatus> M. nipponense> M. monoceros. The adults 96hr-$LC_{50}$ values of hydrogen sulfide were 42.5, 37.8 and $56.6{\mu}g/\ell$ for P. trituberculatus, M. monoceros and M. ripponense, respectively. The order of toxicity of hydrogen sulfide to adults of the three crustaceans was P. tritruberculatus> M. monoceros> M. nipponense. The larval/adult ratios of hydrogen sulfide toxicity were 5.8, 4.1 and 6.3 for P. trituberculatus M. monoceros and M. nipponense respectively, and larvae were found to be more sensitive to hydrogen sulfide than adults in all cases.

  • PDF

A Study on the Efficient Operation of VTS in Inchon (인천항 VTS의 효율적인 운영방안에 관한 연구)

  • 김상환;박진수
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 1998.10b
    • /
    • pp.11-25
    • /
    • 1998
  • Many Countries have made efforts to assist ships navigate accurately , safely and expeditiously for the safety control against increasing marine traffic , in their coastal waters. However, they are exposed in spite of these efforts,to risks of casulaties and marine polluation caused by traffic congestion when ships are navigating through waterways approaches to ports or harbors and in narrow fairways. Therefore, efficient control of VTS in Port is necessary nowadays to provide ships with necessary service , which interacts with shipping and organize the flow of traffic so as to maximize the efficiency of the port or harbor while minimizing the risk of accident and environmental pollution. Even though the navigation condition of ships is very inferior compared to other ports in Korea, such as the big difference between the ebb and flood tide, the frequent fog, the narrow fairway , the density of navigation traffic in Inchon Port is high and transportation quantity of dangerous cargoe increases gradually. In cosideration of the characteristics of natural circumstance and traffic circumstance the VTS established newly in Inchon port have to operate efficiently. The purpose of this study is to help efficient operation of VTS in Inchon port by accomplishing both the literature research and questionnaire survey. Questionnaire survey was read to the VTS personnel in Inchon Port and customer familiar to Inchon Port such as ship navigators, pilots, shipping companies and so on. Most of ship navigators who occupy half of the respondents are Korean Officer who had responded while they were calling at Inchon port. The conclusions and recommendations includes ; First, the service area should be extended over Designated area to provide the vessel with navigational assistance service regarding the information of traffic congestion area, fishing boat and small ship's activities. Second, the types of information service to be offered are ship's movement and weather condition inthe vicinity of the port and state of fairway in the approaching channel to thte fairway. Third, VTS personnel should be upgraded by the on-the-job training and continuous simulation training as well as supplement of the qualified personnel for VTS operation. Fourth , the Harbor Master System to be introduced for safe navigation and efficient port operation.

  • PDF

Comparison and Estimation of Equilibrium Constants for Deoxyribonucleosides by Plate Theory and Moment Method (단이론과 모멘트방법을 이용한 데옥시리보뉴클레오사이드의 평형상수의 계산 및 비교)

  • Lee, Ju Weon;Row, Kyung Ho
    • Applied Chemistry for Engineering
    • /
    • v.8 no.3
    • /
    • pp.403-409
    • /
    • 1997
  • The equilibrium constants of five deoxyribonucleosides (dDyd, dUrd, dGuo, dThd, dAdo) were estimated by the plate theory and the moment method under isocratic conditions of the Reversed-Phase High Performance Liquid Chromatography (RP-HPLC). The mobile phase in this system was composed of water and organic modifiers(acetonitrile and methanol) The plate theory of linear adsorption isotherm was treated on the basis of continuous flow of eluent through the plates of the column. The moment method was utilized to find the equilibrium constant from the first absolute moment of experimental data. The equilibrium constants of five deoxyribonucleosides in the two methods were very close, and also the equilibrium constants calculated by capacity factor were similar to those by both the plate theory and the moment method. The equilibrium constant was expressed as a semi-log function of the quantity of organic modifier. Excellent agreements between the calculated elusion profile by the plate theory and the experimental data were observed.

  • PDF

Comparison of Changes in Upstream and Downstream Water Quality of Tributary Rivers: Gyeseong-stream and Hwapo-stream in Nakdongmiryang Watershed (지류하천의 상·하류 수질변화 비교: 낙동밀양 중권역 내 계성천 화포천을 대상으로)

  • Shim, Kyuhyun;Kim, Gyeonghoon;Kim, Seongmin;Kim, Youngseok;Kim, Jin-pil
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.5
    • /
    • pp.445-452
    • /
    • 2020
  • Tributary is a part of life space for people and a very important place that accommodates rest recreation and other daily activities. absolutely insufficient basic data about water quality and flow rate are available for basin management. Efficient water and basin management systems, which are also supported by local residents can be established by securing such basic data of major tributaries in the Nakdong river system. In this study, the fluctuation characteristics of upstream and downstream water pollution levels were compared using the measurement results of the water environment measurement network and the tributary monitoring project for the gyeseong-stream and Hwapo-stream in the Nakdong-miryang watershed. In 2017, when water pollution is the highest, it was confirmed that the annual average rainfall was the lowest. Although the upstream and downstream water quality tendencies of the Gyeseong-stream are similar, the water quality concentrations of the Gyeseong-stream are relatively different. But although the Hwapo stream has various causes of pollution, there was not much difference in the level of pollution between the upper and lower streams. In addition, both rivers need the ability to purify rivers by securing sufficient water for river maintenance, and if the correlation between water quality items can be inferred through continuous monitoring of tributaries where the aspect of water quality change is unclear, water quality management Determined to be efficient operation.

Numerical Simulation of an Impinging Jet with Various Nozzle-to-strip Distances in the Air-knife System

  • So, Hong-Yun;Yoon, Hyun-Gi;Chung, Myung-Kyoon
    • Corrosion Science and Technology
    • /
    • v.9 no.6
    • /
    • pp.239-246
    • /
    • 2010
  • When galvanized steel strip is produced through a continuous hot-dip galvanizing process, the thickness of the adhered zinc film is controlled by impinging a thin plane nitrogen gas jet. The thickness of the zinc film is generally affected by impinging pressure distribution, its gradient and shearing stress at the steel strip. These factors are influenced by static pressure of gas spraying at air knife nozzle, a nozzle-to-strip distance and strip and a geometric shape of the air knife, as well. At industries, galvanized steel strip is produced by changing static pressure of gas and a distance between the air knife nozzle and strip based on experimental values but remaining a geometric shape of nozzle. Splashing and check-mark strain can generally occur when a distance between the air knife nozzle and strip is too short, while ability of zinc removal can lower due to pressure loss of impinging jet when a distance between the air knife nozzle and strip is too long. In present study, buckling of the jet and change of static pressure are observed by analyzing flow characteristics of the impinging jet. The distance from the nozzle exit to the strip varies from 6 mm to 16 mm by an increment of 2 mm. Moreover, final coating thickness with change of a distance between the air knife nozzle and strip is compared with each case. An ability of zinc removal with the various distances is predicted by numerically calculating the final coating thickness.

Characteristics of Capacitive Deionization Process using Carbon Aerogel Composite Electrodes (탄소에어로젤 복합전극의 전기용량적 탈이온 공정 특성)

  • Lee, Gi-Taek;Cho, Won-Il;Cho, Byung-Won
    • Journal of the Korean Electrochemical Society
    • /
    • v.8 no.2
    • /
    • pp.77-81
    • /
    • 2005
  • Porous-composite electrodes have been developed using silica gel, which reduce carbon aerogel usage with high cost. Silica gel powder was added to the carbon aerogel to simplify the manufacturing procedure and to increase the wet-ability, the mechanical strength and the CDI efficiency. Porous composite electrodes composed of carbon aerogel and silica gel powder were prepared by paste rolling method. Carbon aerosol composite electrodes with $10\times10cm^2$ are placed face to face between spacers, and assembled the four-stage series cells for CDI process. Each stage is composed of 45 cells. Four-stage series cells (flow through cells) for CDI process are put in continuous-system reactor containing 1,000ml-NaCl solution bath of 1,000 ppm. The four-stage series cells with carbon aerogel electrodes are charged at 1.2V and are discharged at 0.001V, and then read the current. Conclusively, removal efficiencies of ions using the four-stage series cells composed of carbon aerogel composite electrodes show good removal efficiency of $99\%$ respectively.

Saltwater Intrusion Monitoring Evaluation through Automatic Vertical Line Method in a Costal Aquifer of the Eastern Part of Jeju Island (수직 라인 관측시스템을 이용한 제주 동부 해안대수층에서 해수침투 모니터링 평가)

  • Jang, Hojune;Ha, Kyoochul;Hwang, Inuk;Kim, Gee-Pyo;Park, Won-Bae
    • Journal of Soil and Groundwater Environment
    • /
    • v.26 no.3
    • /
    • pp.1-13
    • /
    • 2021
  • Groundwater monitoring is commonly practiced with real-time sensors placed in several depth spots in aquifer. However, this method only provides monitoring data at the point where the sensors are installed. In this study, we developed a vertical line monitoring system (VLMS) that can provide continuous data of groundwater parameters along the vertical depth. The device was installed in a well located on the coast of the eastern part of Jeju island to monitor electrical conductivity, temperature, salinity, pH, dissolved oxygen, and oxidation-reduction potential over approximately 3 months from September 11 to December 3, 2020. The results indicated that the groundwater levels fluctuated with the tidal change of seawater level, and the upper and lower boundaries of the freshwater and saltwater zone in the groundwater were located at below 16 m and 36 m of mean sea level, respectively. There was a large variation in EC values during the high tide and temperature change was the greatest during flow tide. Although further investigation is needed for improvement of the device to obtain more accurate and reliable data, the device has a potential utility to provide fundamental data to understand the seawater intrusion and transport mechanisms in coastal aquifers.

Anaerobic Reductive Dechlorination of Tetrachloroethylene (PCE) in Two-in-series Semi-continuous Soil Columns (반연속 흐름 2단 토양 컬럼에서의 사염화 에틸렌(PCE)의 혐기성 환원탈염소화)

  • Ahn, Young-Ho;Choi, Jeong-Dong;Kim, Young;Kwon, Soo-Youl;Park, Hoo-Won
    • Journal of Soil and Groundwater Environment
    • /
    • v.11 no.2
    • /
    • pp.68-76
    • /
    • 2006
  • Anaerobic reductive dechlorination of tetrachloroethylene (PCE) to ethylene was investigated by performing laboratory experiments using semi-continuous flow two-in-series soil columns. The columns were packed with soils obtained from TCE-contaminated site in Korea. Site ground water containing lactate (as electron donor and/or carbon source) and PCE was pumped into the soil columns. During the first operation with a period of 50 days, injected mass ratio of lactate and PCE was 620:1 and incomplete reductive dechlorination of PCE to cis-DCE was observed in the columns. However, complete dechlorination of PCE to ethylene was observed when the mass ratio increased to 5,050:1 in the second operation, suggesting that the electron donor might be limited during the first operation period. Dechlorination rate of PCE to cis-DCE was $0.62{\sim}1.94\;{\mu}mol$ PCE/L pore volume/d and $2.76\;{\mu}mol$ cis-DCE/ L pore volume/d for that for cis-DCE to ethylene, resulting that net dechlorination rate in the system was 1.43 umol PCE/L pore volume/d. During the degradation of cis-DCE to ethylene, the concentration of hydrogen in column groundwater was $22{\sim}29\;mM$ and $10{\sim}64\;mM$ for the degradation of PCE to cis-DCE. These positive results indicate that the TCE-contaminated groundwater investigated in this study could be remediated through in-situ biological anaerobic reductive dechlorination processes.

The Change in the Buddhist Architecture of the Unified Silla Period (668-935) (통일신라시대(統一新羅時代) 불교건축(佛敎建築)의 변화(變化))

  • Kim, Sung-Woo
    • Journal of architectural history
    • /
    • v.1 no.2 s.2
    • /
    • pp.68-84
    • /
    • 1992
  • The development of Buddhist architectures of the Unified Silla period have been generally understood to have paired pagoda instead of one which had been popular until before the unification. Besides the stylistic categorization of paired pagoda system, there had been no further investigation reported concerning whether there was any detailed process of change within the development of paired pagoda style. This paper aims to identify such change inside the development of paired pagoda style, which, externally, seems to be the same pattern of site design maintained throughout the period of Unified Silla that lasted for about three centuries. Since the temple sites of study are in the same pattern of layout, the method of investigation has to be such that can identify the subtle changes that, in external appearance, are not easily discernible. Hence, this research compared the dimensions of important measurement of five temple sites to be able to clarify the process of minor changes. Among many sites of Silla temples, only five were suitable for the research since detailed measurement were possible through field research or the report of excavation. They are the sites of Sachonwang-sa, Mangduk-sa, site of Kunsuri, and Bulguk-sa. Although the five sites have the same style of paired pagoda, it is clear that there were consistant flow of change. Even though the motivation of such change were not strong enough to change the site pattern itself, it resulted continuous minor changes such as the size and location of architectures. The size of image hall, for example, was growing larger and larger as time goes on, while, the size of Pagoda was getting smaller. In the same way, the size of middle gate became smaller while the size of lecture hall became larger, although the rate of change in these cases were not as severe as that of image hall and pagoda. At the same time, pagoda was coming closer to the middle gate leaving larger space in front of the image hall. Such aspect is even more meaningful considering the fact that the pagoda, from the 8th century in Japan and China, moved outside of the major precinct. The image hall, too, moved toward the middle gate slightly so that the space in front of the lecture hall became more spacious. Such changes, of course, were not accidental but they are the same continuous motivation of change that caused the changes before the period of unification. Enlargement of image hall and reduction of pagoda, for example, represent the changing relative importance of religious meaning. Hence, it is evident that one can not easily imterprete the development of one style only by categorizing it to be one same style. In the veiwpoint of the underlying motivation of change, the fact that one style persisted for a certain period of time, does not mean there had been no change, but means that it was the time of motivational accumulation, causing minor changes within the same style, to be able to create major change coming after.

  • PDF

Continuous Wet Oxidation of TCE over Supported Metal Oxide Catalysts (금속산화물 담지촉매상에서 연속 습식 TCE 분해반응)

  • Kim, Moon Hyeon;Choo, Kwang-Ho
    • Korean Chemical Engineering Research
    • /
    • v.43 no.2
    • /
    • pp.206-214
    • /
    • 2005
  • Heterogeneously-catalyzed oxidation of aqueous phase trichloroethylene (TCE) over supported metal oxides has been conducted to establish an approach to eliminate ppm levels of organic compounds in water. A continuous flow reactor system was designed to effect predominant reaction parameters in determining catalytic activity of the catalysts for wet TCE decomposition as a model reaction. 5 wt.% $CoO_x/TiO_2$ catalyst exhibited a transient period in activity vs. on-stream time behavior, suggesting that the surface structure of the $CoO_x$ might be altered with on-stream hours; regardless, it is probable to be the most promising catalyst. Not only could the bare support be inactive for the wet decomposition reaction at $36^{\circ}C$, but no TCE removal also occurred by the process of adsorption on $TiO_2$ surface. The catalytic activity was independent of all particle sizes used, thereby representing no mass transfer limitation in intraparticle diffusion. Very low TCE conversion appeared for $TiO_2$-supported $NiO_x$ and $CrO_x$ catalysts. Wet oxidation performance of supported Cu and Fe catalysts, obtained through an incipient wetness and ion exchange technique, was dependent primarily on the kinds of the metal oxides, in addition to the acidic solid supports and the preparation routes. 5 wt.% $FeO_x/TiO_2$ catalyst gave no activity in the oxidation reaction at $36^{\circ}C$, while 1.2 wt.% Fe-MFI was active for the wet decomposition depending on time on-stream. The noticeable difference in activity of the both catalysts suggests that the Fe oxidation states involved to catalytic redox cycle during the course of reaction play a significant role in catalyzing the wet decomposition as well as in maintaining the time on-stream activity. Based on the results of different $CoO_x$ loadings and reaction temperatures for the decomposition reaction at $36^{\circ}C$ with $CoO_x/TiO_2$, the catalyst possessed an optimal $CoO_x$ amount at which higher reaction temperatures facilitated the catalytic TCE conversion. Small amounts of the active ingredient could be dissolved by acidic leaching but such a process gave no appreciable activity loss of the $CoO_x$ catalyst.