• Title/Summary/Keyword: continuous band

Search Result 283, Processing Time 0.027 seconds

Robust Speech Detection Based on Useful Bands for Continuous Digit Speech over Telephone Networks

  • Ji, Mi-Kyongi;Suh, Young-Joo;Kim, Hoi-Rin;Kim, Sang-Hun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.3E
    • /
    • pp.113-123
    • /
    • 2003
  • One of the most important problems in speech recognition is to detect the presence of speech in adverse environments. In other words, the accurate detection of speech boundary is critical to the performance of speech recognition. Furthermore the speech detection problem becomes severer when recognition systems are used over the telephone network, especially wireless network and noisy environment. Therefore this paper describes various speech detection algorithms for continuous digit recognition system used over wire/wireless telephone networks and we propose a algorithm in order to improve the robustness of speech detection using useful band selection under noisy telephone networks. In this paper, we compare some speech detection algorithms with the proposed one, and present experimental results done with various SNRs. The results show that the new algorithm outperforms the other speech detection methods.

Photosynthetic Characteristics of Polyvinylalcohol-Immobilized Spinach Chloroplasts (Polyvinylalcohol에 고정화한 시금치 엽록체의 광합성특성에 대한 연구)

  • 박인호
    • Journal of Plant Biology
    • /
    • v.34 no.3
    • /
    • pp.215-221
    • /
    • 1991
  • Photoxynthetic properties of polyvinylalcohol (PVA)-immobilized chloroplast especially regarded to stability of photosynthetic electron transport and the fluorescence induction pattern were studied. When isolated spinach chloroplasts were immobilized with PVA, it showed good preservation of photosynthetic electron transport activity, especially PS II activity, during storage at -15$^{\circ}C$, 4$^{\circ}C$ and 2$0^{\circ}C$. And immobilized chloroplasts revealed similar thermostability of whole chain electron transport to free chloroplsts. And the absorption peak of red band of chloroplasts showed the blue-shift of 2-4 nm after immobilization. Fv/Fm ratio of chlorophyll fluorescence slightly decreased after immobilization. White light pulse after continuous light do not induced the additional fluorescence rise. This means chlorophyll fluorescence at room temperature reached to Fmax under continuous light in the immobilized chloroplasts. It seems that PVA may be a good candidate for immobilization matrix for the preservation of photosynthetic function of thylakoids and for the continuous use of chloroplast membranes of higher plants for solar energy storage and conversion.

  • PDF

The Effect of Isothermal Annealing on Microstructure of Forged Parts (단조품의 등온 어닐링에 따른 미세조직 변화)

  • Kim, D.B.;Lee, J.H.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.13 no.5
    • /
    • pp.303-308
    • /
    • 2000
  • The ring gears of automobile parts are manufactured generally process chart of which is as follows : forging ${\rightarrow}$ annealing or normalizing ${\rightarrow}$ rough machining ${\rightarrow}$ hardening(Quenching-Tempering or carburizing process) ${\rightarrow}$ finish machining. Isothermal annealing process after forging is most effective in the side of improvment of machinability. On this study we selected two kinds of steel;SCM415, SCM435 of most universal and investigated microstructures to find out most suitable condition of heat treatment in proportion continuous cooling and isothermal annealing. As the cooling rate is $5^{\circ}C$ per minute in continuous cooling process, martensite and bainite are coexisted with ferrite and pearlite in SCM435 steel. If the cooling rate is slower than $5^{\circ}C$ per minute, microstructure were only ferrite and pearlite but formation of band structure can't be avoid. On the other hand, microstructure is only ferrite and pearlite regardless of cooling rate because carbon content of SCM415 steel is low. Moreover formation of band structure isn't exposed by faster cooling rate. Most optimal temperature of the isothermal annealing is from $650^{\circ}C$ to $680^{\circ}C$ in SCM435 steel. When holding time is 60 minute with $650^{\circ}C$, the identical ferrite and pearlite microstructures can be obtained.

  • PDF

W-band Single-chip Receiver MMIC for FMCW Radar (FMCW 레이더용 W-대역 단일칩 수신기 MMIC)

  • Lee, Seokchul;Kim, Youngmin;Lee, Sangho;Lee, Kihong;Kim, Wansik;Jeong, Jinho;Kwon, Youngwoo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.10
    • /
    • pp.159-168
    • /
    • 2012
  • In this paper, a W-band single-chip receiver MMIC for FMCW(Frequency-modulated continuous-wave) radar is presented using $0.15{\mu}m$ GaAs pHEMT technology. The receiver MMIC consists of a 4-stage low noise amplifier(LNA), a down-converting mixer and a 3-stage LO buffer amplifier. The LNA is designed to exhibit a low noise figure and high linearity. A resistive mixer is adopted as a down-converting mixer in order to obtain high linearity and low noise performance at low IF. An additional LO buffer amplifier is also demonstrated to reduce the required LO power of the W-band mixer. The fabricated W-band single-chip receiver MMIC shows an excellent performance such as a conversion gain of 6.2 dB, a noise figure of 5.0 dB and input 1-dB compression point($P_{1dB,in}$) of -12.8 dBm, at the RF frequency of $f_0$ GHz, LO input power of -1 dBm and IF frequency of 100 MHz.

Design of Over-sampled Channelized DRFM Structure in order to Remove Interference and Prevent Spurious Signal (간섭 제거 및 스퓨리어스 방지를 위한 오버샘플링 된 채널화 DRFM 구조 설계)

  • Kim, Yo-Han;Hong, Sang-Guen;Seo, Seung-Hun;Jo, Jung-Hun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.26 no.8
    • /
    • pp.1213-1221
    • /
    • 2022
  • In Electronic Warfare, the need to develop a jamming system that protects our location information from enemy radar is constantly increasing. The jamming system normally uses wide-band DRFM(Digital Radio Frequency Memory) that processes the entire bandwidth at once. However, it is difficult to jam if there is a CW(Continuous Wave) interference signal in the band. Recently, instead of wide-band signal processing, a structure using a filter bank that divides the entire band into several sub-bands and processes each sub-band independently has been proposed. Although it is possible to handle interference signal through the filter bank structure, spurious signal occurs when the signal is received at a boundary frequency between sub-bands. Spurious signal makes a output power of jamming signal distributed, resulting in lower JSR(Jamming to Signal Ratio) and less jamming effect. This paper proposes an over-sampled channelized DRFM structure that enables interference response and prevents spurious signal for sub-band boundary frequency input.

AKARI OBSERVATIONS OF THE INTERSTELLAR MEDIUM

  • Onaka, Takashi
    • Publications of The Korean Astronomical Society
    • /
    • v.27 no.4
    • /
    • pp.187-193
    • /
    • 2012
  • AKARI has 4 imaging bands in the far-infrared (FIR) and 9 imaging bands that cover the near-infrared (NIR) to mid-infrared (MIR) contiguously. The FIR bands probe the thermal emission from sub-micron dust grains, while the MIR bands observe emission from stochastically-heated very small grains and the unidentified infrared (UIR) band emissions from carbonaceous materials that contain aromatic and aliphatic bonds. The multi-band characteristics of the AKARI instruments are quite efficient to study the spectral energy distribution of the interstellar medium, which always shows multi-component nature, as well as its variations in the various environments. AKARI also has spectroscopic capabilities. In particular, one of the onboard instruments, Infrared Camera (IRC), can obtain a continuous spectrum from 2.5 to $13{\mu}m$ with the same slit. This allows us to make a comparative study of the UIR bands in the diffuse emission from the 3.3 to $11.3{\mu}m$ for the first time. The IRC explores high-sensitivity spectroscopy in the NIR, which enables the study of interstellar ices and the UIR band emission at $3.3-3.5{\mu}m$ in various objects. Particularly, the UIR bands in this spectral range contain unique information on the aromatic and aliphatic bonds in the band carriers. This presentation reviews the results of AKARI observations of the interstellar medium with an emphasis on the observations of the NIR spectroscopy.

Effects of a Thera-Band Exercise Program on Pain, Knee Flexion ROM, and Psychological Parameters Following Total Knee Arthroplasty (슬관절 전치환술 후 세라밴드 운동프로그램이 수술 후 통증, 슬관절 굴곡각도 및 심리적 지수에 미치는 효과)

  • Yun, Ji Yeong;Lee, Jong Kyung
    • Journal of Korean Academy of Nursing
    • /
    • v.45 no.6
    • /
    • pp.823-833
    • /
    • 2015
  • Purpose: The purpose of the study was to investigate the effects of the Thera-Band exercise program following total knee arthroplasty. Methods: The research design for this study was a nonequivalent control group non-synchronized design. Participants were 30 patients for the experimental group and 30 patients for the control group. The experimental group participated in the Thera-Band exercise program in addition to conventional CPM (continuous passive motion) exercise. The control group received conventional CPM exercise only. Outcome measures were pain, knee flexion range of motion, CRP, and psychological parameters (self-efficacy and fear of falling). Data were analyzed using ${\chi}^2$-test, Fisher's exact test, t-test, and repeated measure ANOVA with SPSS/PC version 21.0. Results: There were significant improvement in self-efficacy, and decreases in pain, and fear of falling in the experimental group compared to the control group. However, no significant differences were found between the two groups for CRP and knee flexion ROM. Conclusion: The Thera-Band exercise program gave an additional benefit over the conventional CPM exercise for patients following total knee arthroplasty, and is recommended for use as an effective nursing intervention for patients after total knee arthroplasty.

Field Test and Evaluation of Wind Turbine Noise according to IEC Standards (IEC 규격에 따른 풍력 터빈 소음의 현장 실증)

  • Cheong, Cheol-Ung;Jung, Sung-Su;Cheung, Wan-Sup;Shin, Soo-Hyun;Chun, Se-Jong;Lee, Sang-Hee
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.11a
    • /
    • pp.579-582
    • /
    • 2005
  • The sound measurement techniques in IEC 61400-11 are applied to field test and evaluation of noise emission from 1.5 MW wind turbine generator (WTG) at Yongdang-Lee and 650 kW WTG at Hangwon-Lee in Jeju Island. Apparent sound power level, wind speed dependence and third-octave band levels are evaluated for both of WTGs. 1.5 MW WTG at Yongdang is found to emit lower sound power than 660 kW one at Hangwon, which seems to be due to lower rotating speed of the rotor of WTG at Yongdang. Equivalent continuous sound pressure level s (ECSPL) of 650 kW WTG at Hangwon vary more widely with speed than those of 1.5 MW WTG at Yongdang. The reason for this is believed to be the fixed blade-rotating speed of WTG at Yongdang. One-third octave band analysis of the measured data show that the band components around 400-500 Hz are dominant for 1.5 MW WTG at Yongdang and those around 1K Hz are dominant for 660 kW WTG at Hangwon.

  • PDF

Design of PLL Frequency Synthesizer for a 915MHz ISM Band wireless transponder using CPFSK communication (CPFSK communication 사용한 915MHz ISM Band 위한 PLL Frequency Synthesizer 설계)

  • Kim, Seung-Hoon;Cho, Sang-Bock
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.286-288
    • /
    • 2007
  • In this paper, the fast locking PLL Frequency Synthesizer with low phase noise in a 0.18um CMOS process is presented. Its main application IS for the 915MHz ISM band wireless transponder upon the CPFSK (Continuous Phase Frequency Shift Keying) modulation scheme. Frequency synthesizer, which in this paper, is designed based on self-biased techniques and is independent with processing technology when damping factor and bandwidth fixed to most important parameters as operating frequency ratio, broad frequency range, and input phase offset cancellation. The proposed frequecy synthesizer, which is fully-integrated and is in 320M $^{\sim}$ 960MHz of the frequency range with 10MHz of frequency resolution. And its is implemented based on integer-N architecture. Its power consumption is 50mW at 1.8V of supply voltage and core area is $540{\mu}m$ ${\times}$ $450{\mu}m$. The measured phase noises are -117.92dBc/Hz at 10MHz offset, with low settling time less than $3.3{\mu}s$.

  • PDF

Field Test and Evaluation of Noise from Wind Turbine Generators at Yongdang and Hangwon in Jeju Island (제주도 용당/행원 풍력발전기 현장 소음 실증)

  • Cheong, Cheol-Ung;Jeong, Sung-Su;Cheung, Wan-Sup;Shin, Su-Hyun;Jeon, Se-Jong;Lee, Saeng-Hui
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.818-821
    • /
    • 2005
  • The sound measurement procedures of IEC 61400-11 are applied to field test and evaluation of noise emission from 1.5 MW wind turbine generator (WTG) at Yongdang and 660 kW WTG at Hangwon in Jeju Island. Apparent sound power level, wind speed dependence and third-octave band levels are evaluated for both of WTGs. 1.5 MW WTG at Yongdang is found to emit lower sound power than 660 kW one at Hangwon, which seems to be due to lower rotating speed of the rotor of WTG at Yongdang. Equivalent continuous sound pressure levels (ECSPL) of 660 kW WTG at Hangwon vary more widely with wind speed than those of 1.5 MW WTG at Yongdang. The reason for this is believed to be the fixed blade rotating speed of WTG at Yongdang. One-third octave band analysis of the measured data show that the band components around 400-500 Hz are dominant for 1.5 MW WTG at Yongdang and those around 1K Hz are dominant for 660 kW WTG at Hangwon.

  • PDF