Prevention of Soil Contamination from Underground Storage Facilities (유류저장시설로 인한 토양오염 예방대책)

  • 배우근;홍종철;정진욱;강우재
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1998.11a
    • /
    • pp.169-173
    • /
    • 1998
  • The practice of the construction and management of the underground petroleum storage facilities in Korea was investigated extensively, and the problems were identified. The advanced technologies in the U.S.A was comparatively studied. Considering the effectiveness of leak prevention and technology applicability, the following measures were suggested. To prevent corrosion of the tank, a clad tank, an interior-lining tank, or a double-wall tank was appropriate and appeared to be most cost effective. For piping, non-metalic material was suggested. To prevent spill, a catchment basin can be effective. For monitoring of leak, construction of more than one of one or combination of an automatic leak-detection device, a vapor-detection system, a ground water-monitoring system, and a double-wall detection system was recommended.

  • PDF

우리나라 토양환경관리 현황과 정부의 역할

  • 황상일
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.17-19
    • /
    • 2004
  • Recently, we have recognized that ‘Soil Environmental Prevention Act’could not provide perfect solutions on many complicated problems which are now emerging and/or can be solved by adopting comprehensive policies. In this study, some suggestions were made to solve a few tangled problems such as conducting the Land Partnership Plan(LPP) project, investigating soil and ground water contamination of the industrial area, building a integrated information system for soil and ground water, establishing detailed guidelines for remediation and verification, and re-constructing the legal and institutional framework for integrated management of soil and ground water. These suggestions may help policy makers to build conceptual frameworks for solving these problems.

  • PDF

A Research and Analysis on the Actual Condition of Safety Management at Small-Medium Chemical Plant (중소기업 화학 사업장의 안전관리 실태 조사 분석)

  • 이태우
    • Journal of the Korea Safety Management & Science
    • /
    • v.1 no.1
    • /
    • pp.183-195
    • /
    • 1999
  • Most of chemical plant are using toxic and dangerous materials, inflammable and poisonous. There are many accidental dangers by escaping of fire, explosive and poisonous materials in case of high temperature and pressure. The accidents lead to taking employer's and local people's life and environmental contamination. Therefore, 27 small-medium chemical plant, which size is 30 ∼ 200 employees out of safety management agent ill the area of A was selected in this study. The problems of safety management and several countermeasures at the chemical plants was indicated through the analyzed data. Prior to this analysis, top managers' concerns, equipment maintenance for the safety management are needed. For the future, calamity prevention countermeasures by industrial disaster analysis are needed and active safety management programs are investigated for the industrial disaster prevention and productivity enhancement at the chemical plant.

  • PDF

A Research and Analysis on the Actual Condition of Safety Management at Small-Medium Chemical Plant (중소기업 화학 사업장의 안전관리 실태 조사 분석)

  • 이태우;강경식
    • Proceedings of the Safety Management and Science Conference
    • /
    • 1999.11a
    • /
    • pp.97-108
    • /
    • 1999
  • Most of chemical plant are using toxic and dangerous materials, inflammable and poisonous. There are many accidental dangers by escaping of fire, explosive and poisonous materials in case of high temperature and pressure. The accidents lead to taking employer's and local people's life and environmental contamination. Therefore, 27 small-medium chemical plant, which size is 30∼200 employees out of safety management agent in the area of A was selected in this study. The problems of safety management and several countermeasures at the chemical plants was indicated through the analyzed data. Prior to this analysis, top managers' concerns, equipment maintenance for the safety management are needed. For the future, calamity prevention countermeasures by industrial disaster analysis are needed and active safety management programs are investigated for the industrial disaster prevention and productivity enhancement at the chemical plant.

  • PDF

Prevention of P-i Interface Contamination Using In-situ Plasma Process in Single-chamber VHF-PECVD Process for a-Si:H Solar Cells

  • Han, Seung-Hee;Jeon, Jun-Hong;Choi, Jin-Young;Park, Won-Woong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.204-205
    • /
    • 2011
  • In thin film silicon solar cells, p-i-n structure is adopted instead of p/n junction structure as in wafer-based Si solar cells. PECVD is a most widely used thin film deposition process for a-Si:H or ${\mu}c$-Si:H solar cells. For best performance of thin film silicon solar cell, the dopant profiles at p/i and i/n interfaces need to be as sharp as possible. The sharpness of dopant profiles can easily achieved when using multi-chamber PECVD equipment, in which each layer is deposited in separate chamber. However, in a single-chamber PECVD system, doped and intrinsic layers are deposited in one plasma chamber, which inevitably impedes sharp dopant profiles at the interfaces due to the contamination from previous deposition process. The cross-contamination between layers is a serious drawback of a single-chamber PECVD system in spite of the advantage of lower initial investment cost for the equipment. In order to resolve the cross-contamination problem in single-chamber PECVD systems, flushing method of the chamber with NH3 gas or water vapor after doped layer deposition process has been used. In this study, a new plasma process to solve the cross-contamination problem in a single-chamber PECVD system was suggested. A single-chamber VHF-PECVD system was used for superstrate type p-i-n a-Si:H solar cell manufacturing on Asahi-type U FTO glass. A 80 MHz and 20 watts of pulsed RF power was applied to the parallel plate RF cathode at the frequency of 10 kHz and 80% duty ratio. A mixture gas of Ar, H2 and SiH4 was used for i-layer deposition and the deposition pressure was 0.4 Torr. For p and n layer deposition, B2H6 and PH3 was used as doping gas, respectively. The deposition temperature was $250^{\circ}C$ and the total p-i-n layer thickness was about $3500{\AA}$. In order to remove the deposited B inside of the vacuum chamber during p-layer deposition, a high pulsed RF power of about 80 W was applied right after p-layer deposition without SiH4 gas, which is followed by i-layer and n-layer deposition. Finally, Ag was deposited as top electrode. The best initial solar cell efficiency of 9.5 % for test cell area of 0.2 $cm^2$ could be achieved by applying the in-situ plasma cleaning method. The dependence on RF power and treatment time was investigated along with the SIMS analysis of the p-i interface for boron profiles.

  • PDF

ISO14001-based u-LCA System Development for Operation of Environmental Facilities (환경기초시설 운영을 위한 ISO14001 기반 u-LCA 시스템 개발)

  • Han, Kwang-Rok;Lee, Ki-Cheol;Sohn, Surg-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.8
    • /
    • pp.2117-2125
    • /
    • 2009
  • This paper describes an information system of operation adequacy in environmental facilities such as environmental contamination prevention and processing equipments, which is namely, an integrated management system for environmental facilities. By developing this system, we can improve environmental characteristics and maximize the efficiency throughout the life cycle from generation of contaminant source to contamination prevention processing, and to contaminant disappearance. In order to meet these objects, we have developed ubiquitous life cycle assessment(u-LCA) for environmental facilities, which is an ISO14001-based incineration facility information system. The developed system is currently operating for test at an incinerator in Koyang city. Due to this system, the managers can confirm the operation condition of the incinerator with real-time and they will be able to improve the problems immediately.

The Development of the Contamination Prevention Module of an Optical Window Using Ultrasonic Waves (초음파를 이용한 광학창 오염방지 모듈 개발)

  • Lee, ChangHee;Jeon, KiMun;Shin, JaeSoo;Yun, JuYoung;Cho, Seonghyun;Kang, Sang-Woo
    • Journal of the Korean Vacuum Society
    • /
    • v.22 no.4
    • /
    • pp.175-180
    • /
    • 2013
  • We developed the contamination prevention module of an optical window for an In-Situ Particle Monitor (ISPM) system. the core part of the module is the generator of an ultrasonic wave and the module is to remove particles stuck to the window by the transfer of the wave force to the window surface. In order to enhance transfer efficiency of the waves the frequency of the ultrasonic wave was optimized and a low impedance material (plexiglass) and a soft sealing material (Si rubber) were used. The ISPM with the developed module was installed at the exhaust line of a BPSG CVD equipment and the effect of the module was verified.

Environmental Investigation of a Long-term Care Hospital with Respect to COVID-19

  • Park, Min Woo;Shin, Seung Hwan;Cha, Jeong Ok;Lim, Hyeon Jeong;Kim, Jun Nyun
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.5
    • /
    • pp.599-609
    • /
    • 2020
  • Objectives: Coronavirus disease 2019 (COVID-19) first emerged in December 2019 in Wuhan, China, and has rapidly become a global pandemic with over 26.4 million confirmed cases and approximately 871,000 fatalities worldwide as of this writing. In the Republic of Korea, disease clusters frequently occurred in long-term care hospitals where the majority of residents are elderly with underlying medical conditions. Despite the fact that public health authorities and local community health centers have put tremendous efforts into preventing the spread of disease, positive cases have continued to occur. Thus, the Korea Centers for Disease Control & Prevention rapid response team decided to conduct an environmental investigation of a long-term care hospital to identify whether environmental contamination has remained and contributed to the spread of COVID-19. Methods: An environmental investigation was conducted at Hospital A. The characteristics of the facility and its HVAC system were assessed by checking the layout and interviewing the people in charge. A total of 64 surface samples were collected from areas of concern, including patient rooms, toilets, elevators, and nurses' station. These samples were tested by a regional health and environmental research institute using real-time reverse transcription polymerase chain reaction. Results: All samples from Hospital A were confirmed to be negative. Through interviews with high-level personnel at the regional community health center, we found that extensive disinfection is frequently performed on potentially contaminated areas in Hospital A in accordance with government guidelines. Conclusion: The environmental control measures implemented in Hospital A had been sufficient for mitigating the risk of further infection, suggesting that such measures may also be effective for other long-term health care facilities.

Microbiological Quality Evaluation for Implementation of a HACCP System in Day-Care Center Foodservice Operations II. Focus on Non-Heating Process (보육시설급식소의 HACCP시스템 적용을 위한 미생물적 품질평가 II. 비가열조리 공정을 중심으로)

  • 민지혜;이연경
    • Journal of Nutrition and Health
    • /
    • v.37 no.8
    • /
    • pp.722-731
    • /
    • 2004
  • The objective of this study was to evaluate the microbiological quality of non-heat-processed foods for implementation of a HACCP (Hazard Analysis and Critical Control Point) system in day-care center foodservice operations. The evaluating points were microbial assessment of foods, utensils, and employee's hands during preparation, cooking, and serving. The temperature of non-heated food being served was also measured. Microbiological quality was assessed using 3 M Petrifilm/syp TM/ to measure total plate count and coliforms for food and utensils and Staphylococcus aureus for hands in five Gumi day-care centers. Results showed low microbiological quality of non-heated foods. This was probably due to contaminated raw ingredients and cross-contamination that occurred during preparation and cooking (e.g., unsatisfactory washing and disinfection of raw materials and utensils). These results suggest that it is essential to educate employees on good personal hygiene (hand washing) , prevention of cross-contamination through use of properly washed and sanitized utensils, and proper washing and disinfection of raw vegetables. Establishing Sanitation Standard Operating Procedures (SSOPs) are an essential part of any RACCP system in day-care center foodservice operations.

Study on HVAC System in Nuclear Facility (원자력시설의 공기조화 시스템 고찰)

  • 백상열;송웅섭;오연우;주용선;홍권표
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.503-508
    • /
    • 2003
  • Heating, Ventilation and hir Conditioning (HVAC) system in nuclear facility should be equipped and constructed more stable and allowable than that in common facility. The purpose of HVAC system is the maintenance of optimum working environment, the protection of worker against a contaminated air and the prevention of atmospheric contamination due to a outward ventilation, etc.. The basic scheme of a safety operation of nuclear facility is to prevent the atmospheric contamination even in low level. The adaptability of HVAC system should be taken into account in the design stage so that it is possible to modify the system which is in operation. In this study, the design requirements of HVAC system in nuclear facility and the HVAC systems in foreign countries are reviewed, and the results can be utilized in the design of HVAC system in nuclear facility.

  • PDF