• Title/Summary/Keyword: contamination performance

검색결과 363건 처리시간 0.027초

Prevention of P-i Interface Contamination Using In-situ Plasma Process in Single-chamber VHF-PECVD Process for a-Si:H Solar Cells

  • Han, Seung-Hee;Jeon, Jun-Hong;Choi, Jin-Young;Park, Won-Woong
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.204-205
    • /
    • 2011
  • In thin film silicon solar cells, p-i-n structure is adopted instead of p/n junction structure as in wafer-based Si solar cells. PECVD is a most widely used thin film deposition process for a-Si:H or ${\mu}c$-Si:H solar cells. For best performance of thin film silicon solar cell, the dopant profiles at p/i and i/n interfaces need to be as sharp as possible. The sharpness of dopant profiles can easily achieved when using multi-chamber PECVD equipment, in which each layer is deposited in separate chamber. However, in a single-chamber PECVD system, doped and intrinsic layers are deposited in one plasma chamber, which inevitably impedes sharp dopant profiles at the interfaces due to the contamination from previous deposition process. The cross-contamination between layers is a serious drawback of a single-chamber PECVD system in spite of the advantage of lower initial investment cost for the equipment. In order to resolve the cross-contamination problem in single-chamber PECVD systems, flushing method of the chamber with NH3 gas or water vapor after doped layer deposition process has been used. In this study, a new plasma process to solve the cross-contamination problem in a single-chamber PECVD system was suggested. A single-chamber VHF-PECVD system was used for superstrate type p-i-n a-Si:H solar cell manufacturing on Asahi-type U FTO glass. A 80 MHz and 20 watts of pulsed RF power was applied to the parallel plate RF cathode at the frequency of 10 kHz and 80% duty ratio. A mixture gas of Ar, H2 and SiH4 was used for i-layer deposition and the deposition pressure was 0.4 Torr. For p and n layer deposition, B2H6 and PH3 was used as doping gas, respectively. The deposition temperature was $250^{\circ}C$ and the total p-i-n layer thickness was about $3500{\AA}$. In order to remove the deposited B inside of the vacuum chamber during p-layer deposition, a high pulsed RF power of about 80 W was applied right after p-layer deposition without SiH4 gas, which is followed by i-layer and n-layer deposition. Finally, Ag was deposited as top electrode. The best initial solar cell efficiency of 9.5 % for test cell area of 0.2 $cm^2$ could be achieved by applying the in-situ plasma cleaning method. The dependence on RF power and treatment time was investigated along with the SIMS analysis of the p-i interface for boron profiles.

  • PDF

기계학습 분류모델을 이용한 하천퇴적물의 중금속 오염원 식별 (Identifying sources of heavy metal contamination in stream sediments using machine learning classifiers)

  • 반민정;신상욱;이동훈;김정규;이호식;김영;박정훈;이순화;김선영;강주현
    • 한국습지학회지
    • /
    • 제25권4호
    • /
    • pp.306-314
    • /
    • 2023
  • 하천퇴적물은 유역내 다양한 오염원으로부터 발생하는 중금속, 유기물 등 오염물질의 수용체일 뿐만 아니라 수질 오염 및 수생태 악영향을 유발할 수 있는 2차적 오염원이기에 중요한 관리대상이라고 할 수 있다. 오염된 하천퇴적물의 효과적인 관리를 위해서는 오염원에 대한 식별과 이와 연계된 관리대책의 수립이 우선되어야 한다. 본 연구는 하천퇴적물내 측정된 다양한 이화학적 오염항목 분포 특성에 기반하여 퇴적물의 주요 오염원을 식별하기 위한 방법으로서 기계학습모델의 적용성을 평가하였다. 기계학습 모델의 성능 평가를 위해 전국 4대강 수계내 주요 폐금속광산 및 산업단지 인근에서 수집된 총 356개의 하천퇴적물에 대한 중금속 10개 항목(Cd, Cu, Pb, Ni, As, Zn, Cr, Hg, Li, Al)과 토양항목 3개(모래, 실트, 점토 비율) 수질항목 5개(함수율, 강열감량, 총유기탄소, 총질소, 총인)를 포함한 총 18개 오염항목에 대한 분석자료를 활용하였다. 기계학습 분류 모델로서 선형판별분석(linear discriminant analysis, LDA)과 서포트벡터머신(support vector machine, SVM) 분류기를 사용하여 폐금속광산('광산')과 산업단지('산단') 인근에서의 하천퇴적물 시료의 분류 성능을 평가한 결과, 채취 지점 및 시기별 4가지 경우(비강우시 광산, 강우시 광산, 비강우시 산단, 및 강우시 산단)에 대한 퇴적물 시료의 분류 성능이 우수하였으며, 특히 비선형 모델인 SVM(88.1%)이 선형모델인 LDA(79.5%) 보다 퇴적물을 분류하는데 있어 보다 우수한 성능을 나타냈다. SVM 앙상블 기반 비배타적 다중라벨분류기 모델을 이용하여 각 시료채취 지점 상류 유역 1km 반경 내 지배적인 토지이용 및 오염원을 다중 타겟값으로 다중분류 예측을 수행한 결과, 폐금속광산과 산업단지의 분류는 비교적 높은 정확도로 수행하였으나, 도시와 농업지역 등 다른 비점오염원에 대한 분류정확도는 56~60%범위로 비교적 낮게 나타났다. 이는 다중라벨 분류모델의 복잡성에 비해 데이터셋의 크기가 상대적으로 작아서 발생한 과적합에 기인한 것으로 향후 보다 많은 측정자료가 확보될 경우 기계학습 모델을 적용한 오염원 분류의 정확도를 보다 향상시킬 수 있을 것으로 판단된다.

UHPLC 시스템 종료 및 재가동 시 가이드 (UHPLC System Shutdown and Reactivation Advice)

  • Mark Fever;Gemma Lo
    • FOCUS: LIFE SCIENCE
    • /
    • 제1호
    • /
    • pp.8.1-8.3
    • /
    • 2024
  • Ultra-high performance liquid chromatography (UHPLC) systems are integral to modern analytical laboratories, necessitating careful maintenance and operation protocols to ensure optimal performance. This document provides comprehensive guidelines for the proper shutdown and reactivation of UHPLC systems to prevent damage and maintain operational efficiency. • Shutdown: Remove the column and replace it with a union to avoid blockages. Flush the system with a compatible solvent mix, clean mobile phase reservoirs to prevent microbial growth, flush the pump with storage solvent, and clean the autosampler, including the needle and injection port. • Reactivation: Inspect the system for wear or damage, gradually reintroduce mobile phases starting with a weak solvent, reinstall the column securely, and perform system checks on baseline stability, pressure consistency, and detector performance. By adhering to these guidelines, laboratories can ensure the longevity and reliability of their UHPLC systems, maintaining high analytical performance and minimizing downtime. These procedures help prevent common issues such as blockages, contamination, and component wear, thereby supporting efficient and accurate analytical operations.

  • PDF

보건소 방문간호요원의 감염관리에 대한 중요성 인지도 및 실천도 (Perception of Importance and Performance in the Infection Control of Visiting Nursing Personnel in Public Health Centers)

  • 김금남;오진주
    • 지역사회간호학회지
    • /
    • 제11권2호
    • /
    • pp.389-398
    • /
    • 2000
  • The work of visiting nursing personnel consists mostly of direct nursing and it is absolutely necessary that training of the nursing personnel for infection control be emphasized because most of patients are composed of elderly people with chronic diseases and malnutrition who are highly susceptible to infection. Accordingly. this study was designed to provide basic data for the development of an infection control program in public health centers as well as the promotion of perception and performance of infection control by analysing the perception of importance and performance in the infection control of visiting nursing personnel who carry out visiting nursing services. The subjects of this study consisted of a number of visiting nursing personnel working for 15 public health centers. 15 health-center branches. and 16 health clinics. The collection of data was grounded on a questionnaire method. The questionnaire breaks down to 8 questions about general characteristics and 108 questions in connection with the perception and performance of infection control. The results of this study are as follows: 1. 82 subjects (78.1%) responded that it is necessary to control infection. 79 subjects(75.3%) responded that education is necessary for infection control. 50 respondents (47.6%) answered in the affirmative in regard to the role of infection carriers. 2. The mean score for the perception of importance in infection control was 4.55 and that performance accounts for 4.03. this turns out to be very high. 3. In terms of the perception of importance per each field of infection control. medication. the management of contamination and sterilization, the control of environments and instruments. washing hands and individual hygiene as well as the prevention of cross-infection and the supervision of infection stand at 4.72. 4.64. 4.60. 4.58. 4.52 and 4.21 respectively. In terms of performance. the supervision of infection. the control of environments and instruments, individual hygiene and the prevention of cross infection. medication. washing hands, and the management of contamination and sterilization was 4.21. 4.12. 4.10. 4.03. 3.91 and 3.81 respectively. 4. In terms of the correlation between the perception of importance and the performance of infection control. the score stands high in all fields: this means the high perception of importance leads to high performance statistically (P< .05). 5. In terms of the perception of importance in general characteristics. there is no significant difference while the form of working places. working career and the career as visiting nursing personnel show a significant difference in terms of performance(P< .05). From the results. it is suggested that the visiting nursing personnel should be constantly educated with the aid of the development of infection control programs and that instructions and instruments for the management of infection should be worked out so as to enhance the performance of infection control on the part of nurses in applicable communities.

  • PDF

Investigations of Accelerated Aged Polymeric Insulators Using Partial Discharge Signal Measurement and Analysis

  • Mekala, K.;Chandrasekar, S.;Ravindran, R. Samson
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.299-307
    • /
    • 2015
  • Reduction in pollution performance of polymeric insulators, aged due to water absorption stress and thermal stress, is a major threat to the reliable operation of power transmission and distribution system. Formation of partial discharges on the surface of wet polluted insulator plays a major role in determining the life time and pollution performance of outdoor polymeric insulators. However, reports on partial discharge characteristics of water absorption stress aged and thermal aged polymeric insulators are scanty. This paper discusses the pollution performance characteristics of accelerated aged polymeric insulators using the advanced ultra wide band PD signal measurement and analysis. Laboratory experiments on accelerated aged polymeric insulators were carried out as per IEC 60507 under AC voltage, at different humidity and contamination levels using NaCl as a contaminant. PRPD pattern and Time-Frequency map analysis of PD signals were carried out. From the results, it can be speculated that PD analysis is a well suited technique to understand the pollution performance of aged polymeric insulators.

충진재의 표면처리와 실리콘 고무의 트래킹특성 (The Surface Treatment of Fillers and Tracking Performance of Silicone Rubber)

  • 이수부;지원영;이철규;이준호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2364-2367
    • /
    • 1999
  • Polymer insulating materials are widely used in power distribution and transmission systems for their good dielectric properties, light weight, low cost, and good contamination performance. Tracking is one of the biggest problems to be overcome in polymer insulating materials. The alumina trihydrate(ATH) is widely used as a filler for improve the tracking performance of silicone rubber. In this paper, we have investigated the influence of surface treatment of fillers on the tracking performance of silicone insulator using the IEC 587 tracking test method.

  • PDF

차영상 분석 기반의 자동차 엔진 실링상태 검사 시스템 (Car Engine Sealing Inspection System Based on Analysis of Difference Image)

  • 최상복;반상우;김기택
    • 한국멀티미디어학회논문지
    • /
    • 제14권3호
    • /
    • pp.356-367
    • /
    • 2011
  • 본 논문에서는 차 엔진의 누수 방지를 위한 실링 처리 후 실링 처리 영역에 대한 정확도를 검사하는 새로운 알고리즘을 제안하고, 실제 생산라인에서 동작하는 자동차 엔진 실링검사 시스템을 개발하였다. 검사 방법은 기존에 제안된 영상처리 기법에 기반을 두는 세 가지 검사 방법들이 갖는 설치의 어려움, 높은 계산의 복잡도, 유사 색 기름에 의한 실링검사 성능 저하 등의 여러 가지 단점을 해결하고 저 비용의 시스템을 개발하기 위해 개발되었다. 제안하는 시스템은 기존의 방법에서 적용하지 않은 설링 전후의 차영상을 활용하는 기법을 이용하여 다양한 환경변화에 적응적이며, 고정형 카메라 1대로 검사가 가능한 저 비용 시스템이다. 실제 생산라인에서의 비교 실험을 통해 제안하는 실링검사 방법은 기존의 생산라인에서 적용되고 있는 세 가지 다른 방법들에 비해 높은 실링검사 정확도를 보여 성능의 우수성을 입증하였다.

사료 중 Nivalenol, Deoxynivalenol, T-2 foxin과 Zearalenone의 동시분석과 오염도조사 (Simultaneous Analysis and Survey for Contamination of Nivalenol, Deoxynivalenol, T-2 toxin and Zearalenone in Feed)

  • 김동호;김현정;장한섭;김영민;최흥보;안종성
    • 한국식품위생안전성학회지
    • /
    • 제26권1호
    • /
    • pp.1-11
    • /
    • 2011
  • 국내 유통사료 239점에 대하여 푸사리움 속 곰팡이독소 4종(NIV, DON, T-2, ZEN)에 대하여 오염도조사를 실시하였다. 일반적으로 곰팡이독소 정제에 많이 사용되는 면역친화 컬럼을 사용하지 않고 일반 SPE컬럼을 이용하였으며, HPLC/MS/MS로 동시 분석하였다. 각각의 성분 별로 77.42~111.20%의 회수율과 $0.3{\sim}2.0\;{\mu}g/l$의 양호한 정성한계(LOD)를 보였다. 분석 결과 사료 중에 조사대상 곰팡이독소가 광범위하게 오염되어 있었으며, 특히 DON과 ZEN은 모든 배합에서 확인되었다. 소 사료의 경우 DON과 ZEN은 평균 $812.1\;{\mu}g/kg$$147.2\;{\mu}g/kg$의 오염도를 보여 닭 사료나 돼지 사료보다 약 4배정도 높은 오염도를 보였으며, 그 원료로 사용된 단미 사료를 조사해본 결과 수입 단백피가 주요 오염원인 것으로 확인됐다.

곡류가공품 중 제랄레논 오염도 조사 (Analysis of Zearalenone Contamination in Cereal-Based Products Using High Performance Liquid Chromatography-Fluorescence Detector and Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry)

  • 장미란;이창희;최인선;신춘식;김진희;장영미;김동술;안동현
    • 한국식품과학회지
    • /
    • 제43권2호
    • /
    • pp.224-229
    • /
    • 2011
  • 시중 유통 중인 과자류, 빵, 떡류, 면류 및 선식 등 432건을 immunoaffinity column으로 정제하여 HPLC-FLD로 제랄레논에 대한 오염실태를 조사하였다. 제랄레논의 검량선은 결정계수($R^2$)가 0.999 이상으로 양호한 직선성을 보였고 검출한계 및 정량한계는 각각 2.0, $6.0{\mu}g/kg$, 회수율 80.2-98.4%이었으며 RSD가 0.82-6.40%로 양호한 재현성을 나타내었다. 제랄레논 모니터링 결과, 과자류 중 스낵과자류 66건 중 3건에서 $6.02-11.82{\mu}g/kg$ 검출되었고 비스킷 71건 중 2건에서는 $14.78-17.83{\mu}g/kg$ 검출되었다. 면류, 빵류 및 떡류에서는 제랄레논이 검출되지 않았으며 침출차 14건에서 최고 $53.76{\mu}g/kg$ 검출, 선식 24건 중 16건에서 가장 높은 검출율(66.7%)을 나타내었다. 전분 2건, 시리얼두유 1건에서 제랄레논이 각각 5.55-8.56, $10.26{\mu}g/kg$ 검출되었다. 제랄레논 모니터링 결과는 기준이 설정되어 있는 유럽연합(곡류분말: $75{\mu}g/kg$, 빵, 비스킷, 스낵, 아침식사대용 시리얼류: $50{\mu}g/kg$, 영아 및 유아용 시리얼류: $20{\mu}g/kg$) 기준이하의 수준이었으며 국내외 연구보고와 비교한 결과 낮거나 비슷한 수준으로 검토되었다. 연구결과 곡류가공품에 대한 제랄레논 오염수준은 높지 않았으나 지구 온난화로 기후변화에 민감한 곰팡이독소와 같은 자연독소의 발생 증가가 우려되므로 선제적으로 대응하는 안전관리가 요구된다.

HPLC-FLD 및 LC-MS/MS에 의한 두류 중 제랄레논 오염실태 조사 (A Survey of Zearalenone in Beans Using High Performance Liquid Chromatography-Fluorescence Detector (HPLC-FLD) and Ultra Performance Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS))

  • 장미란;이창희;이효정;김지연;손상혁;신춘식;김소희;김대병
    • 한국식품과학회지
    • /
    • 제40권3호
    • /
    • pp.354-359
    • /
    • 2008
  • 국내유통 중인 대두, 붉은콩, 검은콩 녹두 등 6품목의 두류 총 127건을 immunoaffinity column 정제방법 및 HPLC-FLD을 이용하여 제랄레논에 대한 오염실태를 조사하였다. 상관계수($R^2$) 0.999 이상으로 양호한 직선성을 보였고 검출한계 및 정량한계는 각각 2.0 ${\mu}g/kg$, 6.0 ${\mu}g/kg$, 회수율 82.2-98.4%로 나타났다. RSD가 0.82-6.40%로 양호한 재현성을 나타내었다. 모니터링 결과, 대두(백태) 27건 중 1건(3.7%)에서 37.62 ${\mu}g/kg$ 검출되었고 붉은콩(팥) 27건 중 12건 검출되어 44.4%의 검출율을 보였고 그 오염수준은 8.01-38.98 ${\mu}g/kg$이었다. 나머지 시료 검정콩 16건, 녹두 24건, 서리태(속청) 19건, 서목태(약콩) 14건에서는 모두 검출되지 않았다. 따라서 총 시료 127건 중 13건 검출되어 10.2%의 검출율을 보였고 그 오염수준은 8.01-38.98 ${\mu}g/kg$이었다, 검출시료 13건을 LCMS/MS로 확인한 결과 모두 제랄레논임이 확인되었다. 본 연구결과에서 나타난 두류의 검출빈도 및 오염수준은 유럽연합에서 설정된 기준규격 이하의 수준이었으나 곰팡이독소의 생성의 특이성을 고려한다면 지속적이고 광범위하게 오염실태 조사가 되어야 한다고 판단된다.