• Title/Summary/Keyword: contamination performance

Search Result 366, Processing Time 0.024 seconds

Electrical Conduction Properties of Surface in Materials for Outdoor Insulator (옥외 애자용 재료의 표면 전기전도 특성)

  • 박영국;이운석;정수현;장동욱;임기조
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.10
    • /
    • pp.758-762
    • /
    • 1998
  • Electrical conduction property of insulator surface is most important factor to assess the insulation performances of outdoor insulating materials. In this paper, contamination performance of the materials to be used for outdoor insulator such as porcelain, EPDM, silicone rubber was discussed by measuring properties of average leakage current and scintillation discharge pulses under salt fog conditions. The fog was applied by nozzle in chamber and fogging fluids were deionized distilled water, 0.5wt% NaCI solution and 2wt% NaCl solution. The average leakage current showed linearly with applied voltage at dry and clean surface condition. The magnitude of leakage current was almost same at different kinds of samples. In case of deionized distilled water fog, the characteristics of leakage current and applied voltage were much different to those in case of dry and clean condition with 2wt% salt fog. In case of slat fog pollution condition, the leakage current was increased above critical voltage. the scintillation discharges were also activated at the level. The leakage current and scintillation discharges were increased with increasing pollution degree. The resistance to pollution properties of silicone rubber appeared excellent among them.

  • PDF

Surface aging and hydrophobicity recovery of silicone rubber by salt fog method (Salt fog 시험법에 의한 실리콘 고무의 표면 열화 및 발수성 회복 특성)

  • 김정호;서광석;문중섭;송우창;이재형;박용관;양계준;유영식
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.7
    • /
    • pp.636-641
    • /
    • 2000
  • The purpose of this study is assessing the characteristics of surface aging and recovery of hydrophobicity for silicone rubber which takes a great interest as outdoor insulation recently subjected to the combined stressed of salt fog and AC power. The methods for assessing are contact angle ATR-FRIR, AFM and XRD. In addition salt fog method is adopted as the artificial contamination experiment and AC power is applied 24 hour on and 24 hour off repeatedly for 5 cycles. The results suggest that degraded surface was more rough than virgin but was restored water repellency through the off cycle. It was due to not only the formation of fractal surface but also maintenance of hydrophobic surface by diffusion of low molecular oil. Although surface recovers initial hydropohbicity there are possibilities of decreasing electrical performance due to irreversable changes such as depolymerization of surface and loss of filler particles. This fact is confirmed by surface conductivity measurement showing that the degradation is significant and the recovery of hydrophobicity is imperfect as the energized cycle increases.

  • PDF

Controller Design of a Novel Power Conditioning System with an Energy Storage Device for Renewable Energy Sources under Grid-Connected Operation

  • Park, Sun-Jae;Lee, Hwa-Seok;Kim, Chan-In;Park, Joung-Hu;Jeon, Hee-Jong;Ryeom, Jeongduk
    • Journal of Power Electronics
    • /
    • v.13 no.3
    • /
    • pp.390-399
    • /
    • 2013
  • As a result of the depletion of fossil fuels and environmental contamination, it has become important to use renewable energy. For the stable utilization of renewable energy sources, energy storage devices must be used. In addition, renewable and distributed power sources with energy storage devices must operate stably under grid-connected mode. This paper proposed dynamic response modeling for renewable power generation systems including a charger/discharger with an energy storage device in order to derive a method to guarantee stable operation while fully utilizing the energy from the energy storage device. In this paper, the principle operation and design guidelines of the proposed scheme are presented, along with a performance analysis and simulation results using MATLAB and PSIM. Finally, a hardware prototype of a 1kW power conditioning system with an energy storage device has been implemented for experimental verification of the proposed converter system.

Effects of Non-uniform Pollution on the AC Flashover Performance of Suspension Insulators

  • Zhijin, Zhang;Jiayao, Zhao;Donghong, Wei;Xingliang, Jiang
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.4
    • /
    • pp.961-968
    • /
    • 2016
  • The non-uniform distribution of contamination on insulator surface has appreciable effects on flashover voltage, and corresponding researches are valuable for the better selection of outdoor insulation. In this paper, two typical types of porcelain and glass insulators which are widely used in ac lines were taken as the research subjects, and their corrections of AC flashover voltage under non-uniform pollution were studied. Besides, their flashover characteristics under different ratio (T/B) of top to bottom surface salt deposit density (SDD) were investigated, including the analysis of flashover voltage, surface pollution layer conductivity and critical leakage current. Test results gave the modified formulas for predicting flashover voltage of the two samples, which can be directly applied in the transmission line design. Also, the analysis delivered that, the basic reason why the flashover voltage increases with the decrease of T/B, is due to the decrease of equivalent surface conductivity of the whole surface and the decrease of critical leakage current. This research will be of certain value in providing references for outdoor insulation selection, as well as in proposing more information for revealing pollution flashover mechanism.

Performance of Polymer Suspension Insulator with Shed Profile (갓 형상에 따른 폴리머 현수애자의 열화특성)

  • Cho, H.G.;Lee, U.Y.;Kang, S.H.;Lim, K.J.;Yeo, H.G.;Ji, W.Y.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.539-542
    • /
    • 2003
  • Recently, the polymer insulators which are being used for high voltage applications have some advantages such as light weight, small size, vandalism resistance, hydrophobicity and easy making process. During outdoor service of polymer insulators, the surface of the insulating material is frequently subjected to moisture and contamination which lead to the well known phenomenon of dry band arcing. Their tracking resistance, erosion resistance, end sealing and shed design are very important because dry band arcing causes degradation of polymer surface. The shape design of porcelain insulator is formalized but design standard for polymer insulator is no standardized up to now, much research is necessary in real condition. In this paper, the aging property of polymer insulator with shed shape(regular, alternative type) is analyzed through numerical analysis, CEA(canadian electricity association) tracking wheel test and IEC 61109 Annex C.

  • PDF

Optimal Design Study for Development of Washable Faucet Assembly Housing Including Filtration Filter (여과필터를 포함한 세척이 가능한 수도꼭지 어셈블리 하우징 개발을 위한 최적설계 연구)

  • Son, In-Soo;Bae, Sang-Dae
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.5
    • /
    • pp.581-587
    • /
    • 2021
  • In recent years, contamination of drinking water sources has emerged as a serious social problem, such as a large number of impurities in tap water or groundwater or the supply of suitable water due to rust of pipes. Although the government and public institutions are implementing various measures to protect water sources, they cannot improve water quality in a short period of time because of the enormous cost involved. Therefore, in recent years, preference has been given to a device that converts tap water, which is hard water, into soft water by installing a separate water softener at the faucet from which tap water is discharged. However, the existing filtration device has a problem that filtration performance is gradually lowered when impurities accumulate in the filter, requiring continuous filter replacement. In this study, the optimal design of the filter housing was performed to develop a water softener that can be washed when impurities accumulate on the filter inside the water softener connected to the faucet. For optimal design of the filter housing, fluid and fluid-structural interaction analysis were performed on the design pressure to determine the shape and thickness of the housing, and design review was performed through prototype.

Air Quality Changes in a Museum Damaged by a Tsunami - Whale and Sea Museum, Iwate, Japan -

  • MATSUI, Toshiya;KAWASAKI, Emi;Huttmann, Imme
    • Journal of Conservation Science
    • /
    • v.35 no.1
    • /
    • pp.51-60
    • /
    • 2019
  • This paper provides quantitative data that describes the evolution of the air quality in the Whale and Sea Museum, located in the Iwate prefecture, collected after the 2011 Great East Japan Earthquake and tsunami. The museum was damaged significantly by the disaster, and restoration works continued for over six years. The air quality in the temporary storage facility and museum was monitored during the rehabilitation process. Evaluation of air quality is carried out by gas chromatography- mass spectrometry, ion chromatography and high-performance liquid chromatography. The results showed that the characteristics of the chemical components differed depending on the measurement locations inside the building. The museum atmosphere tended to be alkaline as the airtightness increased because of the maintenance works at the entrance. It was also determined that it was necessary to study the intake/exhaust routes and to clean them according to the contamination degree. In Japan, there are recommended museum air quality standards for acetic acid, formic acid, alkali, and aldehydes. The results indicated that these standards should not be used as a reference for damaged museums. Furthermore, at the temporary storage facilities for to store the collections during the rehabilitation of the museum, solvents such as ethyl benzene, toluene, and xylene are initially abundant, although they can be reduced by ventilation, while other components such as 2E1H was confirmed in this case are likely to remain.

The Status and Plan of KMTNet Operation

  • Lee, Chung-Uk;Kim, Seung-Lee;Lee, Dong-Joo;Cha, Sang-Mok;Lee, Yongseok;Kim, Dong-Jin;Kim, Yunjong;Park, Hong Soo;Kim, Hyun-Woo;Lim, Jin-Sun
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.1
    • /
    • pp.61.2-61.2
    • /
    • 2019
  • A total of 10,317 hours of the KMTNet telescope time were allocated for the predefined science programs, and 7,765 hours have been used for science exposures in Chile, Australia and South Africa last year. The success rate of science observation has increased from 70.7% to 75.3%, and the system operation rate has also increased from 97.6% to 99.6%. There were many improvements in mechanical parts of the dome structure and telescope system, and newly installed filter driers of the CCD camera increased the stability of the system by preventing contamination of oil in the gas line in advance. In order to prepare for the time domain astronomy and multi messenger astronomy era, a pilot program was designed and is now being tested. It targets for fast follow-up observations of optical transient events, however it runs during twilight times only so it does not interrupt any granted science program. A total of 32 SCI papers were published using the system in 2018 and it is a good indication of the high science performance of KMTNet. The selection process of the next observation programs starting from October 2020 and its timeline will be discussed in this meeting.

  • PDF

Suppressing Effect of Hydrogen Evolution by Oxygen Functional Groups on CNT/ Graphite Felt Electrode for Vanadium Redox Flow Battery (탄소나노튜브/흑연펠트 전극의 산소작용기를 활용한 바나듐 레독스 흐름 전지의 수소발생 억제 효과)

  • Kim, Minseong;Ko, Minseong
    • Journal of the Korean institute of surface engineering
    • /
    • v.54 no.4
    • /
    • pp.164-170
    • /
    • 2021
  • Vanadium redox flow batteries (VRFB) have emerged as large-scale energy storage systems (ESS) due to their advantages such as low cross-contamination, long life, and flexible design. However, Hydrogen evolution reaction (HER) in the negative half-cell causes a harmful influence on the performance of the VRFB by consuming current. Moreover, HER hinders V2+/V3+ redox reaction between electrode and electrolyte by forming a bubble. To address the HER problem, carbon nanotube/graphite felt electrode (CNT/GF) with oxygen functional groups was synthesized through the hydrothermal method in the H2SO4 + HNO3 (3:1) mixed acid solution. These oxygen functional groups on the CNT/GF succeed in suppressing the HER and improving charge transfer for V2+/V3+ redox reaction. As a result, the oxygen functional group applied electrode exhibited a low overpotential of 0.395 V for V2+/V3+ redox reaction. Hence, this work could offer a new strategy to design and synthesize effective electrodes for HER suppression and improving the energy density of VRFB.

Implementation of Photovoltaic Panel failure detection system using semantic segmentation (시멘틱세그멘테이션을 활용한 태양광 패널 고장 감지 시스템 구현)

  • Shin, Kwang-Seong;Shin, Seong-Yoon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.12
    • /
    • pp.1777-1783
    • /
    • 2021
  • The use of drones is gradually increasing for the efficient maintenance of large-scale renewable energy power generation complexes. For a long time, photovoltaic panels have been photographed with drones to manage panel loss and contamination. Various approaches using artificial intelligence are being tried for efficient maintenance of large-scale photovoltaic complexes. Recently, semantic segmentation-based application techniques have been developed to solve the image classification problem. In this paper, we propose a classification model using semantic segmentation to determine the presence or absence of failures such as arcs, disconnections, and cracks in solar panel images obtained using a drone equipped with a thermal imaging camera. In addition, an efficient classification model was implemented by tuning several factors such as data size and type and loss function customization in U-Net, which shows robust classification performance even with a small dataset.