• Title/Summary/Keyword: contamination performance

Search Result 363, Processing Time 0.023 seconds

Monte Carlo simulation for verification of nonparametric tests used in final status surveys of MARSSIM at decommissioning of nuclear facilities

  • Sohn, Wook;Hong, Eun-hee
    • Nuclear Engineering and Technology
    • /
    • v.53 no.5
    • /
    • pp.1664-1675
    • /
    • 2021
  • In order to verify the statistical performance of the nonparametric tests used in the MARSSIM approach, all plausible contamination distribution types that can be encountered in a survey area should be investigated. As the first of such investigations, this study aims to perform the verification for normal distribution of the contamination in a survey area by simulating the collection of random samples from it through the Monte Carlo simulation. The results of the simulations conducted for a total of 81 simulation cases showed that Sign test and WRS test both exhibited an excellent statistical performance: 100% for the former and 98.8% for the latter. Therefore, in final status surveys of the MARSSIM approach, a high statistical performance can be expected in applying the nonparametric hypothesis tests to survey areas whose net contamination can be assumed to be normally distributed.

Effects of Formic Acid Administration in the Drinking Water on Performance, Intestinal Microflora and Carcass Contamination in Male Broilers under High Ambient Temperature

  • Aclkgoz, Z.;Bayraktar, H.;Altan, O.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.24 no.1
    • /
    • pp.96-102
    • /
    • 2011
  • In this study, we examined the effects of formic acid administration to the drinking water on performance, intestinal microflora and carcass contamination in male broilers. A total of 312 day-old male broiler chicks were allocated to two groups with three replicates. The first group (control) received normal drinking water (pH 7.4) during the experiment. The second group consumed acidified drinking water (pH 4.5) after 5 d of age. At 43 d of age, twelve birds were randomly selected from the control group to determine the effect of acidified drinking water on carcass contamination. These birds were only given normal or acidified (pH 3) drinking water for 8 h prior to slaughter. The reduction of water pH from 7.4 to 4.5 significantly decreased body weights of male broilers at 21 and 42 d of age. However, no differences were observed between male broilers given normal and acidified drinking water in terms of feed intake, feed conversion ratio and mortality. The pH value of the gizzard contents was not significantly affected by acid water treatment. There were no significant differences in the intestinal population of E. coli, total organism and Salmonella between the groups. The total organism and E. coli counts of the carcass slightly decreased in the acidified group. No Salmonella was identified in carcass samples of any of the treatment groups. The results showed that drinking water acidification did not provide beneficial effects on performance, intestinal microflora and carcass contamination in male broilers.

Effect of CO in Anode Fuel on the Performance of Polymer Electrolyte Membrane Fuel Cell (수소연료 중 일산화탄소의 고분자전해질 연료전지에 대한 영향)

  • Kwon, Jun-Taek;Kim, Jun-Bum
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.19 no.4
    • /
    • pp.291-298
    • /
    • 2008
  • Carbon monoxide(CO) is one of the contamination source in reformed hydrogen fuel with an influence on performance of polymer electrolyte membrane fuel cell(PEMFC). The studies of CO injection presented here give information about poisoning and recovery processes. The aim of this research is to investigate cell performance decline due to carbon monoxide impurity in hydrogen. Performance of PEM fuel cell was investigated using current vs. potential experiment, long time(10 hours) test, cyclic feeding test and electrochemical impedance spectra. The concentrations of carbon monoxide were changed up to 10 ppm. Performance degradation due to carbon monoxide contamination in anode fuel was observed at high concentration of carbon monoxide. The CO gas showed influence on the charge transfer reaction. The performance recovery was confirmed in long time test when pure hydrogen was provided for 1 hour after carbon monoxide had been supplied. The result of this study could be used as a basis of various reformation process design and fuel quality determination.

Analysis of Leakage Current Waveforms for Transmission Line Porcelain Insulators due to ESDD Contamination (ESDD 오손에 따른 송전용자기애자의 누설전류 파형의 분석)

  • Park, Jae-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.10
    • /
    • pp.1461-1470
    • /
    • 2012
  • This paper reports the contamination performance of transmission line porcelain insulators tested under five different contaminant conditions - clean and ESDD (equivalent salt deposit density) level (A, B, C, and D) through measurement of their leakage current under drop of potential method. To estimate the contamination for transmission line porcelain insulators, leakage current waveform and its maximum value were measured under step-up power test. In the clean insulators test, % distortion factors decreased with increasing step-up power, and as the ESDD level increased, some characteristics such as frequency analysis, harmonics and % distortion facotor could be used for contamination diagnosis of the transmission line porcelain insulators.

Estimation of Pollution Degree for Liveline Insulator with Leakage Current Measurement (누설전류 측정을 통한 활선 절연물의 오손도 추정)

  • Shim, Kyu-Il;Choi, Nam-Ho;Park, Kang-Sik;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1472-1474
    • /
    • 2001
  • In this paper, a method was presented to estimate the contamination degree of outdoor insulator by the measurement of surface leakage current. Contamination is one of the most important factor to determine the performance of insulator. Thus, it is very important to exam the contamination degree on the outdoor insulator. There are many limits, such as reliability of data, interval of measurement and similarity of environmental conditions, in conventional method. So, the estimation technique for contamination has been needed to monitor the accurate pollution degree of insulator in situ. In this investigation, phase difference was measured to compare the variance of phase difference with the contamination degree and relative humidity. From the result, we could confirm the capability of the estimation method.

  • PDF

Decrease of PEMFC Performance by Ion Contamination (이온 오염에 의한 고분자전해질 연료전지의 성능저하)

  • Song, Jinhoon;Woo, Myungwu;Kim, Saehoon;Ahn, Byungki;Lim, Taewon;Park, Kwonpil
    • Korean Chemical Engineering Research
    • /
    • v.50 no.2
    • /
    • pp.187-190
    • /
    • 2012
  • Contamination of ion from cathode air on the membrane and electrode assembly (MEA) is the serious degradation source in proton exchange membrane fuel cells (PEMFC). In this study, concentration of ions in air at industry region, street and seaside were measured. There were comparably high concentration of $Na^+$, $K^+$, $Ca^{2+}$ and $Fe^{3+}$ in this regions. This paper shows the effects of MEA contamination by these ions generated from humidification water. After 170 hours of fuel cell operation using city water as humidification water, the performance of unit cell decrease to 11% of initial performance. The electrolyte membrane easily absorbed foreign contaminant cations due to the stronger affinity of foreign cations with the sulfonic acid group compared to $H^+$. The contaminant ions existing in the interface between the platinum catalyst and ionomer layer turn out to be the most serious factor to decrease cell performance.

Performance Evaluation of Fine-Dust Blocking Effect of Functional Clothing (미세먼지 차단 기능성 의류 제품의 성능 평가에 관한 연구)

  • Seok-Ju, Hwang;Chang-Hoon, Lee;Jin-Kyung, Kwon;Young-Sil, Kim;Eun-Jin, Choi;Da-Jin, Kim;Min, Kim;Se-Jin, Yook
    • Particle and aerosol research
    • /
    • v.18 no.4
    • /
    • pp.137-145
    • /
    • 2022
  • As many studies on the harmfulness of fine dust have been reported, awareness of its seriousness is spreading. Recently, interest in indoor air quality as well as air pollution is increasing, and research on measures to block fine dust flowing into the room from the outside is being conducted. The clothing company is launching functional clothing to prevent fine dust attached to clothing from entering the room through outdoor activities. However, it is difficult to confirm whether there is actually fine-dust blocking performance, and there is no evaluation standard. In this study, the contamination rate caused by fine dust was quantitatively compared through image processing after contamination of the outer fabric for 4 types of commercially available functional clothing with fine-dust blocking effect. The difference in particle contamination according to the material of the outer fabric was analyzed by comparing the surface resistance, and it was found that the higher the surface resistance of the outer fabric material, the more fine dust was attached. The analysis method of this study is expected to be able to quantitatively compare and evaluate the fine-dust blocking performance of functional clothing.

The Effects of Organic Contamination and Surface Roughness on Cylindrical Capacitors of DRAM during Wet Cleaning Process

  • Ahn, Young-Ki;Ahn, Duk-Min;Yang, Ji-Chul;Kulkarni, Atul;Choi, Hoo-Mi;Kim, Tae-Sung
    • Journal of the Semiconductor & Display Technology
    • /
    • v.10 no.3
    • /
    • pp.15-19
    • /
    • 2011
  • The performance of the DRAM is strongly dependent on the purity and surface roughness of the TIT (TiN/Insulator/ TiN) capacitor electrodes. Hence, in the present study, we evaluate the effects of organic contamination and change of surface roughness on the cylindrical TIT capacitor electrodes during the wet cleaning process by various analytical techniques such as TDMS, AFM, XRD and V-SEM. Once the sacrificial oxide and PR (Photo Resist) are removed by HF, the organic contamination and surface oxide films on the bottom Ti/TiN electrode become visible. With prolonged HF process, the surface roughness of the electrode is increased, whereas the amount of oxidized Ti/TiN is reduced due to the HF chemicals. In the 80nm DRAM device fabrication, the organic contamination of the cylindrical TIT capacitor may cause defects like SBD (Storage node Bridge Defect). The SBD fail bit portion is increased as the surface roughness is increased by HF chemicals reactions.

A Fundamental Investigation to Develope a Automatic Apparatus for Contamination Measurement (오손도 자동측정장치 개발을 위한 기초연구)

  • 최남호;한상옥
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.3
    • /
    • pp.74-82
    • /
    • 2001
  • To reduce the maintenance expense and the possibility of electric outage and/or accident, which causes the decrease in stability and reliability of transmission/distribution line, most of all, accurate measurement for the degree of contamination should be preceded. But the conventional method (brush wiping method), which is recommended in IEC 60815, has sow significant problem in the aspect of man power, expense, error, and so forth. In this investigation, we purpose the development of a new type automatic measuring apparatus, which could measure the degree of contamination on the surface of insulator in outdoor condition. To design and evaluate the apparatus, a FLUX 2D is used, and various laboratory tests, artificial contamination tests, were carried to proof the actual performance. With the result of these effort, we can get the meaningful conclusion to develope a new type automatic apparatus for contamination measurement.

  • PDF

A Study of the Mask and Hand Contamination in Dental Clinic (치과에서의 마스크 및 손의 미생물 오염정도 비교)

  • Pyo, Eunji;Lee, Kyunghee
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.7 no.3
    • /
    • pp.85-94
    • /
    • 2019
  • Purpose: The purpose of this study was to observe the degree of mask contamination in dental hygienist for general and oral bacteria and to identify areas of mask contamination after treatment. Methods: Masks were collected with every fifty dental hygienists who currently working in the department of preventive dentistry, prosthodontics, and orthodontics in Busan. The mask bacteria were collected in specific upper and side parts of the mask. Hand germs were collected using sterile cotton swabs, and then placed in a sterile conical tube. These were transferred to the laboratory. Hand germs and mask bacteria were incubated with nutrient broth (NB) and brain heart infusion broth (BHI) for 24 hrs and each cultured with NB and BHI plate at $37^{\circ}C$ for 48 hrs. Collected data were analyzed using the SPSS Window 20. Results: The number of bacteria was observed in the order of the department of preventive dentistry ($10.1{\times}10^5CFU/ml$), prosthodontics ($14.7{\times}10^5CFU/ml$), and orthodontics ($23.3{\times}10^5CFU/ml$) in the hand. In general bacteria, the difference of contamination was seen by the parts of the mask, but there was no significant difference. However, the oral bacteria were observed highly contaminated upper part of the mask in preventive dentistry. The mask contamination according to the medical departments was observed. Especially, the contamination of mask in preventive dentistry was significantly higher than other departments in oral bacteria. Conclusion: This study suggested that correct mask replacement and recognition of contamination areas can contribute to the prevention of infectious disease. and it would be necessary to increase hand hygiene performance to prevent cross-infection with masks. Also, this study may give an idea for making guidelines for mask management and supporting to establish clear criteria for the education program of personal protective equipment.