• Title/Summary/Keyword: contamination level

Search Result 1,026, Processing Time 0.024 seconds

A Pathway Analysis Model for Determining Acceptable Levels of Contamination of Radionuclides in Soil (토양의 방사능오염 허용기준치 설정을 위한 피폭경로모델)

  • Lee, Chang-Woo;Kim, Kug-Chan;Lee, Jeong-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.15 no.2
    • /
    • pp.67-74
    • /
    • 1990
  • A methodology for calculating acceptable levels of contamination of radionuclides in soil for unrestricted use was described. Pathways of exposure include direct radiation from ground surfaces, ingestion of contaminated food and inhalation of resuspended radionuclides. Results calculated using site-specific data for Korean environment were discussed and compared with those estimated by other guidelines.

  • PDF

Contamination Level of Retail Meat and Chickens by Quantitative Test of Food Poisoning Bacteria (식중독균의 정량시험에 의한 시판 식육 및 계육의 오염도 평가)

  • 강호조;김용환;손원근
    • Journal of Food Hygiene and Safety
    • /
    • v.15 no.3
    • /
    • pp.204-208
    • /
    • 2000
  • The contamination levels of food poisoning bacteria was investigated from 350 samples of beef, 338 samples of pork, and 360 samples of chicken during the period from March 1996 to October 1998. The contamination levels of pathogenic organisms were higher in refrigerated meat than packed frozen meat and were relatively higher in chicken and packed meat than in beef The highest level detected for each of the various pathogens was . less than 10,000 cfu/g for Staphylococcus aureus : less than 0.9 MPN/g for Salmonella and Literia monocytogenes: 7MPN/g for Campylobacter jejuni /coli. In the comparisions of cross- contamination ratio of tested meat for low species food poisoning bacteria 14.3% of beef, 23.5% of pork and 55.0% of chicken were contained only one species of pathogen, whereas 2.7 of beef, 5.6% of pork and 14.7% of chicken contained two species and 2.3% of pork contained a total of three species. Generally, pathogens was encounted higher isolation freguency in packed frozen chicken meat than in chilled chickens.

  • PDF

Introduction on the Contamination Design Standard(Revision Proposal) of 345kV/154kV Transmission System in KEPCO (345kV/154kV 직접접지계 송전설비의 내오손 설계기준(안) 해설)

  • Shim, E.B.;Woo, J.W.;Kwak, J.S.;Min, B.W.;Lee, O.B.;Shin, T.W.;Park, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.262-264
    • /
    • 2002
  • This paper shows the design standard of KEPCO on the contamination design for 345 kV and 154 kV transmission tower. Up to now, because the design standard of KEPCO on the insulation design contains 154 kV transmission system only, we had investigated the 343 kV system for the revision of design standard, with respect to the contamination design, we have used the same design philosophy which were adopted to the 765 kV transmission tower. In order to determine the number of insulator discs, we had investigated the withstand voltage of discs according to the level of ESDD(Equivalent Salt Deposit Density) and kinds of disc types. The TOV(Power Frequency Temporary Overvoltage) were estimated by EMTP(Electromagnetic Transient Program) for both 154 kV and 345 kV transmission system. The overvoltage level was appeared 1.35 p.u. between phase to ground for both 154 kV and 345 kV transmission system, but finally this factor was not applied to the design standard considering current design standard and economic point of view. With regard to classification of contamination area of 345 kV transmission system, we added the clean area which was not specified in the current design practise.

  • PDF

Microbial Contamination Level and Disinfection Effect of Electrolyzed Water in the Production Process of Dried-Laver Pyropia sp. (마른김(Pyropia sp.) 가공 공정에서의 미생물 오염도 및 전기분해수의 처리 효과)

  • Cho, Jong-Lak;Hong, Do-Hee;Kim, Young-Mog;Kim, Hyun-Joong;Kim, Jeong-Mok
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.55 no.5
    • /
    • pp.662-669
    • /
    • 2022
  • The purpose of this study is to test the effects of electrolyzed water treatment on dried-laver Pyropia sp. processing facilities to control microbial contamination. Following the progression of the process to the next step, as well as during the lapse between process operating hours, the contamination level of total viable cell counts (TVC) and total coliform (TC) of laver increased. The TVC increased during the aging step, and after the molding-drying steps were completed, it increased by approximately 2.0 log CFU (colony forming unit)/g. Freshwater used for processing in April had a TVC of 4.31 log CFU/mL, which was more polluted than 2.61 log CFU/mL of seawater. Electrolyzed water was used to treat the sponge used in the laver-molding process, which resulted in a 2 log CFU/mL decrease.The TVC of dried-laver decreased by 1 to 2 log CFU/g when electrolyzed water was applied to the process. In conclusion, application of electrolyzed water in dried-laver processing was shown to be effective in reducing the microbiological contamination of the final product.

The analysis of heavy metal total contents In milt of Han river (한강유역 저니층의 중금속 함량 전분석)

  • 정일현;김세진
    • Journal of environmental and Sanitary engineering
    • /
    • v.9 no.2
    • /
    • pp.63-71
    • /
    • 1994
  • An analytic and comparative study on the level of concentration on heavy metals in silt of Han- River was described. The Paldang lake supplies tap water resources for the 20 million residents in the metropolitan zone. It is composed that three steps for water works by the water volume in all 35,072 thousand tons : the first section is 7,251 thousand tons, the second is 15,980 thousand tons and the third is 11,841 thousand tons. However, recently it has becoming a serious social issue for water contamination on Paldang by heavy metals due to gathering of silt. It has concentrated on analysis and comparison study on the level of heavy metals between contamination- estimated zone and the other zones. After all, Concentration on heavy metals of expected none pollute's zone and expected pollute's zone indicate almost similar results. In the end, heavy metals within silt of Han- River consider not to effect on pollution but quantity of natural condition.

  • PDF

기름 유출로 인한 토양 및 지하수의 오염

  • Kim Dong-Jin;Yang Jae-Eui;Yu Jin-Yeol;Kim Hui-Gap;Kim Gi-Dong
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2006.04a
    • /
    • pp.424-427
    • /
    • 2006
  • Soil contamination with petroleum oil around a military army was investigated. It showed that soils of a riverside highland, an entrance of the military army, and nearby roads were contaminated with total petroleum hydrocarbons (TPH) released from the military army to the depth of approximately 2 m. The measured concentrations were as high as 15,277 mg/kg. A wide range of soil in the riverside highland was contaminated by the movement of oil to the surface soil, which occurred with the vertical movement of groundwater table caused by the change of river water level and groundwater level. Spilled petroleum oil components were released into Wonju Stream by the increase of hydraulic conductivity and the groundwater flow.

  • PDF

Visualization and contamination analysis for groundwater quality of CDEWSF in Gwangju area using statistical method (통계적 기법을 이용한 광주지역 민방위비상급수용 지하수 수질 오염도 분석 및 시각화 연구)

  • Jang, Seoeun;Lee, Daehaeng;Kim, Jongmin;Kim, Haram;Jeong, Sukkyung;Bae, Seokjin;Cho, Younggwan
    • Analytical Science and Technology
    • /
    • v.31 no.3
    • /
    • pp.122-133
    • /
    • 2018
  • In this study, groundwater quality data measured for 11 years from 2006 to 2016 were analyzed statistically for 101 civil defense emergency water supply facilities (CDEWSF) in the Gwangju area. The contamination level was quantified into four grades by using excess drinking water quality standards, average concentration analysis, and tendency analysis results for each facility. On the basis of this approach, the groundwater contamination degree of each item was evaluated according to land use status, installation year, depth, and geological distribution. The contamination grade ratios, which were obtained by analyzing three contamination indicators (water quality exceeded frequency, average concentration analysis, and trend analysis) for 15 items on statistically significant of civil defense emergency water was relatively high, in the order of Turbidity (51.5 %) > Color (32.7 %) > Nitrate nitrogen (28.7 %) > Hardness (25.7 %). As a result of the contamination grade analysis, except for the items of Turbidity, Color, and Nitrate nitrogen, the contamination levels were distributed in various degrees from "clean (0)" to "seriously contaminated (3)." Regarding the contamination grade of 12 items, 25 % of the total were classified as "possibly contaminated (1)," and 75 % were rated "clean (0)." The four items (Turbidity, Color, Nitrate nitrogen, and Hardness) for which contamination indication rate were evaluated as "high" by the were visualized on a contamination map.

Effect of quaternary ammonium compounds on microbial contamination levels in dental clinics (치과 진료실의 미생물 오염도에 대한 4차 암모늄 화합물의 효과)

  • Baik, Sae Yun;Park, YounJung;Choi, Seung Ho;Kim, Hee Jae;Kim, Seong Taek
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.1
    • /
    • pp.55-60
    • /
    • 2020
  • The aim of this study was to investigate the change of microbial contamination levels in the different areas and at the different time points after application of a quaternary ammonium compound (QAC) that has mechanical antimicrobial effect. The microbial contamination levels were measured in three different areas; unit chair handle, spit sink area and hand piece holder at different time points using adenosine triphosphate (ATP) monitoring system and ATP surface test kit. Hand piece holder showed the highest level of microbial contamination. In most of the clinics, QAC significantly reduced the levels of microbial contamination, and maintained antimicrobial activity for 4 to 6 months. QAC may be used effectively in dental clinics due to the duration of antimicrobial effect and the minimal exposure of chemicals and further studies are needed with large sample size.

Practical Radiation Safety Control: (I) Application of Annual Limit on Intake and Derived Air Concentration (방사선안전관리 실무: (I) 연간섭취한도와 유도공기중농도의 적용)

  • Kim, Hyun Kee
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.4
    • /
    • pp.234-236
    • /
    • 2013
  • Some of radioactive contamination is unavoidable in the facilities using the unsealed radioactive material. The primary purpose of radioactive contamination control in the workplace with contamination concern is the effects from the potential intake of radioactive material into the body. This paper provides procedures to estimate the level of internal exposure for the worker based on the conservative assumptions and simple calculations. They consist of two processes; to calculate air concentration of radioactive material and annual intake by inhalation with contaminated air and to compare each of them to Derived Air Concentration and Annual Limit on Intake mentioned in the related notification. The procedures are applicable to make a decision on practical requirements for monitoring air contamination and internal exposure of worker as follows; needs for measurement of air contamination and internal exposure and acquisition of information on the design of the ventilation system.

Evaluation of contamination for the Andong-dam sediment and a magnetic separation for reducing the contamination level

  • Hong, H.P.;Kwon, H.W.;Kim, J.J.;Ha, D.W.;Kim, Young-Hun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.21 no.2
    • /
    • pp.31-35
    • /
    • 2019
  • Andong-dam was built up in 1967 and it is one of the biggest dams in Korea. Previous studies showed that the sediments are highly contaminated with heavy metals such as arsenic, cadmium, and lead. Many research projects are going on to find out the source of the contamination, to evaluate the toxicities to ecosystem, to estimate the volume of sediment to be treated and to find out a good remediation method. Reports show that the sediment is highly contaminated and the main contamination source is supposed to be abandoned mines and a zinc refinery located upper stream of the river. A magnetic separation has been tested as a treatment method for the dredged sediment. Lab scale test showed that the magnetically captured portion is about 10% in weight but the contamination of heavy metal is much higher than the contamination of the passed portion. This indicates that a magnetic separation could be applied for the purpose of reduction of sediment to be treated and for increasing the volume of low toxic sediments which can be dumped as general waste. A magnetic separation using a HGMS has been tested for the sediment with variable magnetic field and the results showed the higher magnetic field increase the captured portion but the concentrating effect of heavy metal was weakened. Further study is needed to establish a useful technology and optimization between decontamination and reduction of sediment volume.