• Title/Summary/Keyword: contamination degree

Search Result 338, Processing Time 0.027 seconds

Estimation of Pollution Degree of Surface Sediment from Incheon H Wharf (인천 H항 표층 퇴적물의 오염도 평가)

  • Kim, Jeong-Ho;Nam, Se-Yong
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.20 no.5
    • /
    • pp.504-510
    • /
    • 2014
  • In this study, physico-chemical properties and pollution degree of surface sediments collected at 5 stations(S1~S5) of Incheon H wharf in March 2014 were investigated. From particle size, surface area, XRD and XRF analyses, the sediment samples consisted of similar oxides and minerals. Considering total score of COD, AVS and IL, pollution level ranged between 2 and 3 based on domestic standards. In case of heavy metal contamination, Cd, Ni and Pb were classified as moderately polluted by USEPA standards. However, Cu, Zn and Cr were classified as heavily polluted. With geoaccumulation index value($I_{geo}$), Cd contamination was estimated as class 3. In addition, the calculated enrichment factors of Cd, Pb and Zn were exceeded a value of 1. Site S4 was high as 3.1 in total enrichment factor.

Postharvest Procedures on Storage, Management and Utilization of Sweetpotato (고구마의 수확 후 관리현황과 개선방안)

  • Ahn Young-Sup;Jeong BC;Lee JS;Chung MN;Kim HS
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2004.10a
    • /
    • pp.36-41
    • /
    • 2004
  • Postharvest handling of sweetpotatoes is inevitable procedure for the maintenance, storage, management and utilization of high fresh quality of storage roots. It ranges in degree from simple lifting of roots, carrying them from field to storage house and immediate consumption after cooking, to sophisticated methods of curing, and storage under controlled conditions followed by processing into a high quality food products. Postharvest saleability, quality and nutritional value of roots and the presence or absence in roots of bitter, toxic furanoterpenoid phytoalexins or mycotoxins depends greatly on the degree and types of treatment to which produce is subjected. Climatic and soil conditions before harvest and contamination or attack by microorganisms or insect pests in the field may initiate or enhance subsequent postharvest deterioration. Careless postharvest handling can lead to both quantitative and qualitative losses which may be extremely high in some circumstances. Research has concentrated on the improvement of preharvest conditions to increase yield and lower decrease rates. However, such efforts are wasted unless they go hand in hand with others designed to reduce the high degree of loss associated with careless postharvest handling.

  • PDF

A Study on the heavy metal contents in the soils and vegetables (중금속에 의한 토양오염과 그 작물함량에 관한 연구)

  • 김명미;고영수
    • Journal of Food Hygiene and Safety
    • /
    • v.1 no.1
    • /
    • pp.51-56
    • /
    • 1986
  • In the particular area the heavy metal concentrations in the soil were determined and compared to the contents in vegetables which were grown on the soil. Simultaneously the degree of contamination was examined. Samples were collected from Chinese cabbage, radish and Altari-mu, together with the soil on which the three kinds of vegetables have grown. The sites of samples collection were Jinguan-sa(non-polluted area) and Sangaedong(polluted area). The contents of cadimium, copper, lead and zinc were determined by means of atomic absorption spectro-photometer. The results obtained were as follows; 1. In soils, the average contents of heavy metal in Jinguan-sa area (Cd; 0.15ppm, Cu; 0.15ppm, Zn; 11.5ppm) were lower than those in sangye-dong(Cd; 0.26ppm, Cu; 13.0ppm, Zn; 17.1ppm). 2. In vegetables, the average have metal contents in Jinguan-sa were cadmium; 0.11ppm, copper; 5.29ppm, zinc; 18.75ppm and the average contents in Sangye-dong were cadmium; 0.16ppm, copper; 6.64ppm, lead; 0.14ppm, zinc; 15.01ppm. 3. The contents of lead showed zero ppm in Jinguan-sa area(soil and vegetables). In vegetables difference in concentration of heavy metals was not observed between reclaimed area and non reclaimed area. Statistical analysis showed that no correlation in the heavy metal concentrations between those in soils and in vegetables.

  • PDF

The Electrical Properties of Non-Uniformly Contaminated Insulator (국부오손에 의한 절연물의 전기적 특성)

  • Choi, Nam-Ho;Park, Kang-Sik;Koo, Kyung-Wan;Kim, Jong-Serk;Han, Sang-Ok
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.935-938
    • /
    • 2002
  • The degree of contamination in outdoor insulation system is one of the most importance factor to determine the level of insulation, and the salt is known as the most dangerous contaminants in the most region of the world. In a macroscopic point of view, as shown through the preceding study, the generation and deposition of salt contaminants has a great relation with the geographical conditions and the meteorological conditions, such as, wind velocity, wind direction, precipitation and so forth. However, in the aspect of microscopic analysis, the pollution mechanism has a great relation with aerodynamic properties of insulator, originated from the profile of insulators, and the non-uniform deposition is unevitable. So, in this investigation, we had make a experiment to seize the electrical properties of non-uniformly contaminated insulator. The results of this investigation could be used as a good groundwork in the determination of outdoor insulation design.

  • PDF

Degradation of Phenanthrene by Bacterial Strains Isolated from Soil in Oil Refinery Fields in Korea

  • KIM JEONG DONG;SHIM SU HYEUN;LEE CHOUL GYUN
    • Journal of Microbiology and Biotechnology
    • /
    • v.15 no.2
    • /
    • pp.337-345
    • /
    • 2005
  • The degradation of phenanthrene, a model PAH compound, by microorganisms either in the mixed culture or individual strain, isolated from oil-contaminated soil in oil refmery vicinity sites, was examined. The effects of pH, temperature, initial concentration of phenanthrene, and the addition of carbon sources on biodegradation potential were also investigated. Results showed that soil samples collected from four oil refinery sites in Korea had different degrees of PAH contamination and different indigenous phenanthrene-degrading microorganisms. The optimal conditions for phenanthrene biodegradation were determined to be 30$^{circ}C$ and pH 7.0. A significantly positive relationship was observed between the microbial growth and the rate of phenanthrene degradation. However, the phenanthrene biodegradation capability of the mixed culture was not related to the degree of PAH contamination in soil. In low phenanthrene concentration, the growth and biodegradation rates of the mixed cultures did not increase over those of the individual strain, especially IC10. High concentration of phenanthrene inhibited the growth of microbial strains and biodegradation of phenanthrene, but was less inhibitory on the mixed culture. Finally, when non-ionic surfactants such as Brij 30 and Brij 35 were present at the level above critical micelle concentrations (CMCs), phenanthrene degradation was completely inhibited and delayed by the addition of Triton X100 and Triton N101.

Energy Efficiency & Sustainability the Cleanliness Management Role of Components and System in Automotive and Hydraulics

  • Hong, J.H.;Day, Mike
    • Journal of Drive and Control
    • /
    • v.9 no.4
    • /
    • pp.19-25
    • /
    • 2012
  • This paper explains how eliminating contamination from the manufacturing processes will lead to better product quality and hence the need for reworking, a trouble free commissioning period and greatly improved production efficiency. All of these will reduce costs and energy usage. It will also ensure that the product is delivered to the customer in a condition that will ensure improved reliability and longer life, again reducing both energy and other operating costs. Correctly designing the contamination control measures will achieve and maintain the level of fluid cleanliness that is required by the end user. The filter is critical to cleanliness management and should be selected with the same degree of thought and consideration as for other major components. This paper explains the role that Cleanliness Management plays in the reducing the carbon footprint of systems and processes by making them perform more efficiently for longer periods. It also examines two differing ways of selecting filters to incorporate the features of newer designs, and shows how significant savings in the costs of ownership can be achieved using these approaches.

Properties of PD Pulses accompanying with propagation of Bush-type tree in LDPE (LDPE에서 부시형 전기트리의 성장에 수반되는 부분방전 펄스의 특성)

  • 박영국;강성화;정수현;박철현;임기조
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.293-296
    • /
    • 1998
  • Surface electrical conduction in insulator is most important factor to assess the insulation performances of outdoor insulating materials. In this paper, contamination performance of the widely used materials for outdoor insulator - porcelain, EPDM, Silicone rubber - were discussed by measuring properties of average leakage current and scintillation discharge pulses under artificial contamination conditions. The artificial contaminations used were deionized distilled water fog, 0.5wt% NaCl salt fog of light pollution and 2wt% NaCl salt fog of medium pollution. The average leakage current was appeared linearly with applied voltage at dry and clean surface condition. The magnitude of leakage current was almost same at different kinds of samples. In case of deionized distilled water fog, the characteristics of leakage current and applied voltage was most different to that in case of dry and clean condition. In case of salt fog pollution condition, The leakage current was increased above critical voltage. The scintillation discharges were also activated at the level. the leakage current and scintillation discharges were increased with increasing pollution degree. The resistance to pollution properties of silicone rubber appeared excellent among them.

  • PDF

A Three-Dimensional CFD Study on the Air Flow Characteristics in a Wax Spin Coater for Silicon Wafer Manufacturing (실리콘 웨이퍼 생산공정용 왁스 스핀코팅장치 내 기류 특성에 대한 3차원 전산유동해석)

  • Kim, Yong-Ki;Kim, Dong-Joo;Umarov, Alisher;Kim, Kyoung-Jin;Park, Jun-Young
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.6
    • /
    • pp.146-151
    • /
    • 2011
  • Wax spin coating is a part of several wafer handling processes in the silicon wafer polishing station. It is important to ensure the wax layer free of contamination to achieve the high degree of planarization on wafers after wafer polishing. Three-dimensional air flow characteristics in a wax spin coater are numerically investigated using computational fluid dynamics techniques. When the bottom of the wax spin coater is closed, there exists a significant recirculation zone over the rotating ceramic block. This recirculation zone can be the source of wax layer contamination at any rotational speed and should be avoided to maintain high wafer polishing quality. Thus, four air suction ducts are installed at the bottom of the wax spin coater in order to control the air flow pattern over the ceramic block. Present computational results show that the air suction from the bottom is quite an effective method to remove or minimize the recirculation zone over the ceramic block and the wax coating layer.

Studies on the Water Quality of Ground Water in Seoul Area and Correlation Analysis Among their Contaminants (서울지역 지하수의 오염도와 성분별 相關性 檢討)

  • Ahn, Soo-Mi;Oh, Soo-Kyoung;Park, Sung-Bae
    • Journal of Environmental Health Sciences
    • /
    • v.15 no.1
    • /
    • pp.51-62
    • /
    • 1989
  • This survey was performed to investigate contamination degree and significance in each item of 406 samples of ground water, which was collected in Seoul area from Jan. to Dec. 1988. The results of this study were as follows 1. The unsuitable rate of ground water investigated was 69.7%(32.4% in only bacteria, 23.6% in both bacteria and physico-chemistry and 13.6% in only physico-chemical contamination). 2. The unsuitable rate in each item was the highest(54.2%) in standard plate countland 29.8% in coliform, 12.8% in turbidity, 11.3% in Zn, and 10.8% in Mn. 3. The total mean concentrations in each item were lower than standard except standard plate count, coliform, and Fe. 4. In the analysis of corelation, among items, both total hardness and residual solids were showed very high correlationship (P < 0.01) with other items, and both S.P.C. and coliform showed very highly significant (P < 0.01) with NH$_3$-N.

  • PDF

Determination of Phthalates Compounds in the Ambient Atmosphere (II) - Evaluation of Experimental Artifacts and Sample Clean-up Procedures - (환경대기 중 프탈레이트 화합물의 농도 측정 (II) - 실험재료 전처리 및 시료정제과정 평가 -)

  • Park, Young-Hwa;Hwang, Yoon-Jung;Seo, Young-Kyo;Baek, Sung-Ok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.5
    • /
    • pp.455-460
    • /
    • 2010
  • This study was carried out to find out any inherent problems occurring in the sampling and analytical procedures, and to suggest the relevant solutions to the problems. In addition, an optimal condition of clean-up process was developed, which was based on a method using silica glass column. As a result of experiments to test any artificial contamination of blank samples such as glassware and collection media, artifacts of DBP and DEHP appeared to be detected in various kinds of laboratory tools and apparatuses used in the sampling and analytical works. Therefore, it is necessary to investigate a degree of contamination before laboratory works by conducting a prior check any possible contaminations in all experimental tools and apparatus. It is also necessary to devise a method to avoid a tool, if possible, or to use a substitute of phthalate free. If the use of any plastic tool to cause contamination is inevitable, it should be properly corrected with a blank level, as is equally treated as the sample. The clean-up process demonstrated in this study can give us a significant benefit in terms of the quantity and quality of a target compound by GC/MS analysis.