Journal of the Korean Society of Marine Environment & Safety
/
v.20
no.5
/
pp.504-510
/
2014
In this study, physico-chemical properties and pollution degree of surface sediments collected at 5 stations(S1~S5) of Incheon H wharf in March 2014 were investigated. From particle size, surface area, XRD and XRF analyses, the sediment samples consisted of similar oxides and minerals. Considering total score of COD, AVS and IL, pollution level ranged between 2 and 3 based on domestic standards. In case of heavy metal contamination, Cd, Ni and Pb were classified as moderately polluted by USEPA standards. However, Cu, Zn and Cr were classified as heavily polluted. With geoaccumulation index value($I_{geo}$), Cd contamination was estimated as class 3. In addition, the calculated enrichment factors of Cd, Pb and Zn were exceeded a value of 1. Site S4 was high as 3.1 in total enrichment factor.
Proceedings of the Korean Society of Crop Science Conference
/
2004.10a
/
pp.36-41
/
2004
Postharvest handling of sweetpotatoes is inevitable procedure for the maintenance, storage, management and utilization of high fresh quality of storage roots. It ranges in degree from simple lifting of roots, carrying them from field to storage house and immediate consumption after cooking, to sophisticated methods of curing, and storage under controlled conditions followed by processing into a high quality food products. Postharvest saleability, quality and nutritional value of roots and the presence or absence in roots of bitter, toxic furanoterpenoid phytoalexins or mycotoxins depends greatly on the degree and types of treatment to which produce is subjected. Climatic and soil conditions before harvest and contamination or attack by microorganisms or insect pests in the field may initiate or enhance subsequent postharvest deterioration. Careless postharvest handling can lead to both quantitative and qualitative losses which may be extremely high in some circumstances. Research has concentrated on the improvement of preharvest conditions to increase yield and lower decrease rates. However, such efforts are wasted unless they go hand in hand with others designed to reduce the high degree of loss associated with careless postharvest handling.
In the particular area the heavy metal concentrations in the soil were determined and compared to the contents in vegetables which were grown on the soil. Simultaneously the degree of contamination was examined. Samples were collected from Chinese cabbage, radish and Altari-mu, together with the soil on which the three kinds of vegetables have grown. The sites of samples collection were Jinguan-sa(non-polluted area) and Sangaedong(polluted area). The contents of cadimium, copper, lead and zinc were determined by means of atomic absorption spectro-photometer. The results obtained were as follows; 1. In soils, the average contents of heavy metal in Jinguan-sa area (Cd; 0.15ppm, Cu; 0.15ppm, Zn; 11.5ppm) were lower than those in sangye-dong(Cd; 0.26ppm, Cu; 13.0ppm, Zn; 17.1ppm). 2. In vegetables, the average have metal contents in Jinguan-sa were cadmium; 0.11ppm, copper; 5.29ppm, zinc; 18.75ppm and the average contents in Sangye-dong were cadmium; 0.16ppm, copper; 6.64ppm, lead; 0.14ppm, zinc; 15.01ppm. 3. The contents of lead showed zero ppm in Jinguan-sa area(soil and vegetables). In vegetables difference in concentration of heavy metals was not observed between reclaimed area and non reclaimed area. Statistical analysis showed that no correlation in the heavy metal concentrations between those in soils and in vegetables.
Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
/
2002.07b
/
pp.935-938
/
2002
The degree of contamination in outdoor insulation system is one of the most importance factor to determine the level of insulation, and the salt is known as the most dangerous contaminants in the most region of the world. In a macroscopic point of view, as shown through the preceding study, the generation and deposition of salt contaminants has a great relation with the geographical conditions and the meteorological conditions, such as, wind velocity, wind direction, precipitation and so forth. However, in the aspect of microscopic analysis, the pollution mechanism has a great relation with aerodynamic properties of insulator, originated from the profile of insulators, and the non-uniform deposition is unevitable. So, in this investigation, we had make a experiment to seize the electrical properties of non-uniformly contaminated insulator. The results of this investigation could be used as a good groundwork in the determination of outdoor insulation design.
The degradation of phenanthrene, a model PAH compound, by microorganisms either in the mixed culture or individual strain, isolated from oil-contaminated soil in oil refmery vicinity sites, was examined. The effects of pH, temperature, initial concentration of phenanthrene, and the addition of carbon sources on biodegradation potential were also investigated. Results showed that soil samples collected from four oil refinery sites in Korea had different degrees of PAH contamination and different indigenous phenanthrene-degrading microorganisms. The optimal conditions for phenanthrene biodegradation were determined to be 30$^{circ}C$ and pH 7.0. A significantly positive relationship was observed between the microbial growth and the rate of phenanthrene degradation. However, the phenanthrene biodegradation capability of the mixed culture was not related to the degree of PAH contamination in soil. In low phenanthrene concentration, the growth and biodegradation rates of the mixed cultures did not increase over those of the individual strain, especially IC10. High concentration of phenanthrene inhibited the growth of microbial strains and biodegradation of phenanthrene, but was less inhibitory on the mixed culture. Finally, when non-ionic surfactants such as Brij 30 and Brij 35 were present at the level above critical micelle concentrations (CMCs), phenanthrene degradation was completely inhibited and delayed by the addition of Triton X100 and Triton N101.
This paper explains how eliminating contamination from the manufacturing processes will lead to better product quality and hence the need for reworking, a trouble free commissioning period and greatly improved production efficiency. All of these will reduce costs and energy usage. It will also ensure that the product is delivered to the customer in a condition that will ensure improved reliability and longer life, again reducing both energy and other operating costs. Correctly designing the contamination control measures will achieve and maintain the level of fluid cleanliness that is required by the end user. The filter is critical to cleanliness management and should be selected with the same degree of thought and consideration as for other major components. This paper explains the role that Cleanliness Management plays in the reducing the carbon footprint of systems and processes by making them perform more efficiently for longer periods. It also examines two differing ways of selecting filters to incorporate the features of newer designs, and shows how significant savings in the costs of ownership can be achieved using these approaches.
Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
/
1998.06a
/
pp.293-296
/
1998
Surface electrical conduction in insulator is most important factor to assess the insulation performances of outdoor insulating materials. In this paper, contamination performance of the widely used materials for outdoor insulator - porcelain, EPDM, Silicone rubber - were discussed by measuring properties of average leakage current and scintillation discharge pulses under artificial contamination conditions. The artificial contaminations used were deionized distilled water fog, 0.5wt% NaCl salt fog of light pollution and 2wt% NaCl salt fog of medium pollution. The average leakage current was appeared linearly with applied voltage at dry and clean surface condition. The magnitude of leakage current was almost same at different kinds of samples. In case of deionized distilled water fog, the characteristics of leakage current and applied voltage was most different to that in case of dry and clean condition. In case of salt fog pollution condition, The leakage current was increased above critical voltage. The scintillation discharges were also activated at the level. the leakage current and scintillation discharges were increased with increasing pollution degree. The resistance to pollution properties of silicone rubber appeared excellent among them.
Kim, Yong-Ki;Kim, Dong-Joo;Umarov, Alisher;Kim, Kyoung-Jin;Park, Jun-Young
Journal of the Korean Society of Manufacturing Process Engineers
/
v.10
no.6
/
pp.146-151
/
2011
Wax spin coating is a part of several wafer handling processes in the silicon wafer polishing station. It is important to ensure the wax layer free of contamination to achieve the high degree of planarization on wafers after wafer polishing. Three-dimensional air flow characteristics in a wax spin coater are numerically investigated using computational fluid dynamics techniques. When the bottom of the wax spin coater is closed, there exists a significant recirculation zone over the rotating ceramic block. This recirculation zone can be the source of wax layer contamination at any rotational speed and should be avoided to maintain high wafer polishing quality. Thus, four air suction ducts are installed at the bottom of the wax spin coater in order to control the air flow pattern over the ceramic block. Present computational results show that the air suction from the bottom is quite an effective method to remove or minimize the recirculation zone over the ceramic block and the wax coating layer.
This survey was performed to investigate contamination degree and significance in each item of 406 samples of ground water, which was collected in Seoul area from Jan. to Dec. 1988. The results of this study were as follows 1. The unsuitable rate of ground water investigated was 69.7%(32.4% in only bacteria, 23.6% in both bacteria and physico-chemistry and 13.6% in only physico-chemical contamination). 2. The unsuitable rate in each item was the highest(54.2%) in standard plate countland 29.8% in coliform, 12.8% in turbidity, 11.3% in Zn, and 10.8% in Mn. 3. The total mean concentrations in each item were lower than standard except standard plate count, coliform, and Fe. 4. In the analysis of corelation, among items, both total hardness and residual solids were showed very high correlationship (P < 0.01) with other items, and both S.P.C. and coliform showed very highly significant (P < 0.01) with NH$_3$-N.
Park, Young-Hwa;Hwang, Yoon-Jung;Seo, Young-Kyo;Baek, Sung-Ok
Journal of Korean Society of Environmental Engineers
/
v.32
no.5
/
pp.455-460
/
2010
This study was carried out to find out any inherent problems occurring in the sampling and analytical procedures, and to suggest the relevant solutions to the problems. In addition, an optimal condition of clean-up process was developed, which was based on a method using silica glass column. As a result of experiments to test any artificial contamination of blank samples such as glassware and collection media, artifacts of DBP and DEHP appeared to be detected in various kinds of laboratory tools and apparatuses used in the sampling and analytical works. Therefore, it is necessary to investigate a degree of contamination before laboratory works by conducting a prior check any possible contaminations in all experimental tools and apparatus. It is also necessary to devise a method to avoid a tool, if possible, or to use a substitute of phthalate free. If the use of any plastic tool to cause contamination is inevitable, it should be properly corrected with a blank level, as is equally treated as the sample. The clean-up process demonstrated in this study can give us a significant benefit in terms of the quantity and quality of a target compound by GC/MS analysis.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.