• 제목/요약/키워드: contamination degree

검색결과 338건 처리시간 0.028초

옥외절연물의 오손도 파악을 위한 위상차 측정 (A Estimation of Contamination Degree by the Measurement of Phase Difference on the Outdoor Insulator)

  • 심규일;이원영;한상옥;박강식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집
    • /
    • pp.443-446
    • /
    • 2002
  • In this paper, a phase difference of liveline insulator was measured and analyzed to estimate the contamination degree. The probability of accident rises according to the increase of the contamination. So the estimation of contamination degree is very important in design and maintenance of outdoor insulator. There are many methods to measure the contamination degree, but those methods use the spacial sense to measure the contamination degree. So, we have no information about the contamination from the liveline insulator, but there is a measurement of phase difference to estimate the contamination degree. The phase difference is varied with the increase of ESDD, so the contamination degree could be estimated by using those characteristics. The experiment is performed to analyze the interrelationship between contamination degree and phase difference. The variable condition is relative humidity that increases from 30 to 100 % in a chamber. We use the DAS program to measure and analyze the data. From the result, the variation of phase difference is different by the contamination degree, so we can confirm the possibility of estimating the contamination degree by the phase difference.

  • PDF

발진주파수 및 전도도를 통한 오손도 자동측정 (Automatic Measurement of the Degree of Contamination with Electric Conductivity and Oscillating Frequency)

  • 최남호;구경완;이명섭;한상옥;정재기
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.153-156
    • /
    • 2000
  • To reduce the maintenance expense, and the possibility of electric outage and accident, we should optimize the outdoor insulation system. And for the optimization, accurate measurement for the degree of contamination with climatic conditions, such as wind, rain, and drought, should be carried. However the classical measuring method, brush wiping, has some problems in the aspect of man power, reliability, and expense. In this paper, we propose two type apparatus, which could detect the degree of contamination on insulators in outdoor insulation system, such as transmission and distribution line insulator and bushing. One use the leakage current, and the other use the oscillating frequency to check the degree of contamination. To avoid the oxidation of electrode AC source, and the low degree of contamination was applied. From the result of this investigation we could get the good relationship between the degree of contamination and the leakage current and oscillating frequency

  • PDF

누설전류 측정을 통한 활선 절연물의 오손도 추정 (Estimation of Pollution Degree for Liveline Insulator with Leakage Current Measurement)

  • 심규일;최남호;박강식;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1472-1474
    • /
    • 2001
  • In this paper, a method was presented to estimate the contamination degree of outdoor insulator by the measurement of surface leakage current. Contamination is one of the most important factor to determine the performance of insulator. Thus, it is very important to exam the contamination degree on the outdoor insulator. There are many limits, such as reliability of data, interval of measurement and similarity of environmental conditions, in conventional method. So, the estimation technique for contamination has been needed to monitor the accurate pollution degree of insulator in situ. In this investigation, phase difference was measured to compare the variance of phase difference with the contamination degree and relative humidity. From the result, we could confirm the capability of the estimation method.

  • PDF

환경조건의 변화에 따른 EPDM 애자의 표면 오손정도의 진단기술 (Diagnosis Technique of Surface Contamination Degree for EPDM Insulator according to Variation of Environment Condition)

  • 박재준;최인혁;김정부
    • 한국전기전자재료학회논문지
    • /
    • 제17권10호
    • /
    • pp.1132-1141
    • /
    • 2004
  • The waveforms of the leakage currents for the surface discharge according to the degree of salt contamination and the variation of environmental condition on the EPDM polymer insulators, were shown in this paper. The variation phenomena of fundamental wave, 3rd and 5th harmonic waveforms were also shown from the beginning of the applied voltage and to the flashover voltage. To develop the technique of percentage contamination degree of EPDM polymer insulator according to the variation of environmental condition, the distortion degree of 3rd and 5th harmonic wave to the fundamental wave was utilized through the spectrum analysis for the waveforms of leakage current in the simulation of salt and fog test. The fact that distortion degree % of 3rd and 5th harmonics for fundamental wave is a necessary indicator for the assessment of contamination degree for the polymer insulators, was known.

종합병원 영상의학과의 감염관리 대한 분석 (Analysis on infection control of general hospital radiology)

  • 신정섭;박철우;전병규
    • 한국방사선학회논문지
    • /
    • 제6권5호
    • /
    • pp.335-342
    • /
    • 2012
  • 경상북도에 소재한 5개 종합병원 영상의학과의 오염도를 계수하고, 오염 원인균을 배양하여 동정하고 이를 토대로 지역사회 영상의학과의 효율적인 감염관리 방안을 모색하고자 하였다. 확인된 표면오염 균주는 Staphylococcus, Micrococcus, Pseudomonas stutzeri, Pseudomonas oryzihabitans로 병원 감염의 원인균으로 알려진 균주였고 영상의학과의 오염원으로 특이성을 가진 균주는 없었다. 조사대상 병원은 비슷한 감염관리교육을 실시하고 있었으나 병원별 오염도의 차이는 유의한 차이를 보였다. 조사대상 병원별 접촉원에 따른 오염도의 차이는 방사선사 사용, 환자사용, 공통사용으로 구분하여 분석한 결과 환자사용이 방사선사사용, 공통사용에 비해 유의하게 높은 오염도를 보였다(p<0.001). 병원별 월평균 검사건수의 차이가 적은 장치는 모든 병원에서 유의한 차이를 보이지 않았으나 이에 비해 촬영건수가 가장 많은 일반촬영장치, 흉부전용촬영대의 오염도가 다른 촬영장치에 비해 오염도가 높았다. 또한 월평균 촬영건수가 많은 A, B, C 병원은 방사선사가 단독으로 사용하거나 또는 환자와 공통으로 사용하는 방사선조사장치, 사무용책상, 출입문 손잡이에서 비교적 높은 오염도를 보였다.

기후인자와 ESDD간의 상관관계 분석통한 오손도 예측 (The prediction of contamination degree through the relationship analysis between the climatic factor and ESDD)

  • 이원영;김도영;박흥석;한상옥;박강식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.1
    • /
    • pp.440-443
    • /
    • 2003
  • Recently, with the rapid growth of industry, environmental condition became worse. With the mix of the various contaminants, such as, salts, dust and industrial pollutants, synergy effect could be happened. So, many researches have been focused on the issue. The cause of natural accident could be classified as, lightning, rainstorm and contamination. However, the accident by contamination influences on the larger area than that by lightning, and, in the case of rapid contamination, it takes a shorter time than rainstorm. The salt contaminant is one of the most representative pollutants, and known as the main source of the accident by contamination. So, in this investigation we make a research on the prediction of contamination degree through the relationship analysis between the climatic factor and ESDD.

  • PDF

통계적 분석 방법을 이용한 국가지하수수질측정망의 오염 등급 정량화 및 평가 (Quantification and Evaluation of Groundwater Quality Grade by Using Statistical Approaches)

  • 윤희성;배광옥;이강근
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제17권1호
    • /
    • pp.22-32
    • /
    • 2012
  • This study suggests a method to grade groundwater quality quantitatively using statistical approaches for evaluating the quality of groundwater in wells included in the Groundwater Quality Monitoring Network (GQMN). The proposed analysis method is applied to GQMN data from 2001 to 2008 for nitrate nitrogen, chloride, trichloroethylene, potential of hydrogen (pH), and electrical conductivity. The analysis results are obtained as groundwater quality grades of the groundwater representing each of the monitoring stations. The degree of groundwater contamination is analysed for water quality parameters, district, and usage. The results show that the degree of groundwater contamination is relatively high by nitrate nitrogen, bacteria and electrical conductivity and at Seoul, Incheon, Gwangju, Gyeonggido and Jeollado. The degree of contamination by nitrate nitrogen and trichloroethylene is especially high when the groundwater is used for agricultural and industrial water, respectively. It is evaluated that potable groudnwater in GQMN is significantly vulnerable to nitrate nitrogen and bacteria contamination.

시장의약품(市販醫藥品)의 미생물(微生物) 오염도(汚染度) 조사(調査) (제1보)(第1報) -시판내복액제(市販內服液劑)의 세균오염도(細菌汚染度)- (A Survey on Microbial Contamination of Currently-Sold Drugs (I) -Bacterial contamination of marketed liquid-)

  • 박영주;김영일
    • Journal of Pharmaceutical Investigation
    • /
    • 제3권4호
    • /
    • pp.5-15
    • /
    • 1973
  • An investigation was carried out on a basis of the bacteriological examination with a view to detecting the degree of bacterial contamination for the 77 samples collected from the locally-sold liquid specialties. It's test period was 50 days from July 10 to August 30, 1971. Specially, the survey has put emphasis on the population of general bacteria and the identification of coli-form group, staphylococcus species, streptococcus species, bacillus species, fungi, and yeast species from liquid samples. The results obtained are summarized as follows; (1) For the 77 samples tested, the contamination of general bacteria was found out as minimun 0, i,e., maximum, $12{\times}10^4$ and the total average $45{\times}10^2$ per milliliter. (2) Although streptococcus species could not be detected with the samples, the contamination of the coli-form and staphylococcus species means the strong suggestion of the possibility of pathogenic bacterial contamination. (3) Specially, the products which stay in the neutral pH range and use suspending agents need to care for the microbial contamination in the manufacturing crocess. (4) It is thought necessary to perform the microbiological quality control in the liquid preparations only at least. (5) As the microbial contamination degree in the liquid decreases according to the elapse of time, the microbiological quality control will have to be carried out immediately after the completion of the manufacturing process in order to know the accurate degree. (6) The author thinks that the main reason of the microbial contamination in the liquid is the contamination during the manufacturing process. (7) For the purpose of prevention of the microbial contamination in liquid, therefore, it is more important to make efforts for the rationalization of manufacturing process, the improvement of equipment and environment, the specific training of workers for hygienic knowledges, etc. rather than the use of preservatives for the preparations.

  • PDF

한강 저질중의 중금속 오염도 평가 방법에 관한 연구 (Studies on the Evaluation Method of Heavy Metal Contamination Degree in the Han River)

  • 어수미;박성배
    • 한국환경보건학회지
    • /
    • 제18권1호
    • /
    • pp.47-57
    • /
    • 1992
  • This study was performed to evaluate contamination degree of heavy metals in sediments of Han River, compared with other nation's evaluation method. The results were as follows 1. The contamination Ratio calculation method by heavy metal concentration in differnt fraction size has a limitation to apply to all of the areas of Han river because of its characteristics of sediment. As a result, this method applied to only 4 areas of Pal Dang, Wang Sook Chon, Uk Chon, and Bul Kwang Chon, and Contmination Ratio of heavy metals in those areas were relatively low of below 3. So it's considered that those areas have less contaminated from anthropogenic contaminants. 2. The Contamination Ratio calculation method by heavy metal concentration in different areasthat of upper area to be background level-has a limitation also to apply to Han river. But it is considered that this method was relatively suitable to apply, so it should be prepared evaluation standand method for them. Contamination ratio from background level as Pal Dang area were most high in An Yang Chon. So it must be prepared purification and control measure at An Yang Chon.

  • PDF

제주도 지하수 관정 내 질산성질소 오염도 평가 (Evaluation of Nitrate Nitrogen Contamination Degree in Groundwater Wells, Jeju Island)

  • 송성호;황보동준;장기영;김진성;서상기;양원석
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제26권4호
    • /
    • pp.8-19
    • /
    • 2021
  • In this study, the evaluation standard for nitrate nitrogen contamination degree (WELCUP) was established using six factors that influence the groundwater quality in Jeju Island. To do this, weightings, ranges, and ratings were assigned for each factor and the relative possibility of nitrate nitrogen contamination degree was evaluated using WELCUP index for each well. As a result of calculating the WELCUP index using groundwater quality data of 5,112 wells in Jeju Island for 27 years (1993-2019), all 61 wells with the WELCUP index value higher than 100 are distributed in Daejung and Hangyung watershed with relatively large area of farmland in Jeju Island. In particular, as the ratio of private wells is more than 64%, it is necessary that systematic management is needed for private wells in terms of nitrate nitrogen contamination. Consequently, based on the results of applying the WELCUP evaluation standard, it is necessary to select the prioritization of nitrate nitrogen contamination pathways project for groundwater wells in Jeju Island.