• Title/Summary/Keyword: container detection

Search Result 91, Processing Time 0.021 seconds

Development of X-ray Non-destructive Testing (NDT) Equipment for the Detection of Alien Substances (이물질 검출을 위한 X-Ray 비파괴검사 장비 개발)

  • Yoo, Young-Tae;Oh, Joon-Ho;Kim, Jin-Woo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.8
    • /
    • pp.60-66
    • /
    • 2019
  • This study aims to develop and manufacture a device for inspecting impurities in a sealed aluminum container using an X-ray technique. Two X-ray oscillators and detectors are used to detect the entire sample. The stage for sample movement was fabricated using two high-voltage generators and X-ray detectors arranged diagonally. In addition, the high-voltage generator is composed of a vacuum tube, a high-voltage generator, and circulating oil for cooling. It includes a control unit for controlling other equipment, a power supply unit, and a video output unit; the most important part of the X-ray is the X-ray generation part. In this study, a flat panel was used along with the aim of developing the detector part. In particular, the development of the scintillator introduced in this study is a primary focus. The developed scintillator can be combined with a lens and can then be assembled with a charge coupled device (CCD) sensor.

A Case Report of Cardiac Arrest Following Intentional Ingestion of Liquid Nicotine for Electronic Cigarette (전자담배용 니코틴 원액 음독 후 발생한 심정지 1례)

  • Kim, Jung Ho
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.16 no.2
    • /
    • pp.172-175
    • /
    • 2018
  • Acute nicotine poisoning by liquid nicotine for electronic cigarettes is becoming an increasing problem worldwide. On the other hand, there are no regulations regarding its concentration, container or labelling in Korea. This is the first case of a cardiac arrest after liquid nicotine ingestion that was confirmed by plasma nicotine detection in Korea. A 34-year-old male was found with a cardiac arrest at home by the emergency medical services crew, and had a return of spontaneous circulation after 27 minutes of cardio-pulmonary resuscitation. The cause of his cardiac arrest was suspected to be acute nicotine poisoning by the ingestion of liquid nicotine. Toxicology analysis of the National Forensic Service confirmed plasma nicotine, and the pharmacokinetic estimated average concentration of plasma nicotine at the time of the cardiac arrest was 29.7 mg/L, a lethal dose. He was hospitalized for further treatment, but was discharged after 20 days without any improvement. Considering the strong toxicity of nicotine, appropriate policy decisions are required for sales and distribution.

Time Serial Concentration of Phthalate Esters and Bisphenol-A Contaminated from Spring Water Container's Cap and Seal Film

  • Park Chan Koo;Shin Jeong Sik;Kim Min Young;Kim Pan Gyi
    • Journal of Environmental Health Sciences
    • /
    • v.31 no.6
    • /
    • pp.457-466
    • /
    • 2005
  • Industrial plasticizers such as phthalates can induce peroxisome proliferation. A growing concern among environmental and health groups has arisen because phthalates such as di-2-ethy1hexy1 phthalate (DEHP) and DBP may cause hormonal disorders, reproductive toxicity, hepatocellular tumors, genital disorders owing to a capacity to bind estrogen receptors, and a low-dose toxic action during certain periods of fetal development. Phthalate esters are used extensively as a plasticizer for plastic manufacture such as PVC bags and medical devices. This study investigated the effects of leached components from spring water container's cap and seal film. Phthalates, e.g. dimethy1 phthalate (DMP), diethy1 phthalate (DEP), di-n-buty1 phthalate (DBP), benzy1buty1 phthalate (BBP), di-(2-ethy1hexy1) phthalate (DEHP), and bisphenol A (BPA) were measured in the spring water. The bisphenol A was not detected or below the detection limit on the leaching from cap, sealing or spring water. DEHP were detected 90-116 ppb on the leaching from seal after 2 weeks, and 0.48-0.51 ppb from the spring water after I week. BBP were measured from seal within 1 week 25.4-66 ppb and below 0.12 ppb from spring water within 2 days. DMP were detected from seal within 2 weeks 51-68.5 ppb and 0.12 ppb after 2 weeks. DEP were measured from seal within 2 weeks 48.1-141 ppb and the concentrations were increased by the time from 0.10 to 0.31 ppb at spring water. DBP were detected from the seal within 2 weeks 92.3-5100 ppb and the concentration were decreased by the time from 0.24 to 0.10 ppb at spring water. These results indicate that some phthalate esters contaminated with spring water using the intact cap and seal film. It is concluded that the measured levels of phthalates leaching from these materials might in vivo only be slightly less than 1/10 of the LOAEL.

A Study on Development of Remote Crane Wire Rope Flaws Detection Systems (원격 크레인 와이어 로프 결함 탐지 시스템 개발에 관한 연구)

  • Min, Jeong-Tak;Lee, Jin-Woo;Lee, Kwon-Soon
    • Journal of Navigation and Port Research
    • /
    • v.27 no.1
    • /
    • pp.97-102
    • /
    • 2003
  • Wire ropes are used in a myriad of various industrial applications such as elevator, mine hoist, construction machinery, lift, and suspension bridge. Especially, the wire rope of crane is important component to container transfer. If it happens wire rope failures during the operation, it may lead to safety accident, economic loss by productivity decline and so on. To solve this problem, we developed remote wire rope fault detecting system, and this system is consisted of 3 parts that portable fault detecting part, signal processing part and remote monitoring part. All detected signal has external noise or disturbance according to circumstances. So, we applied to discrete wavelet transform to extract a signal from noisy data. It is verified that the detecting system by de-noising has good efficiency for inspecting faults of wire ropes in service. As a result, by developing this system, container terminal could reduce expense because of extension fo wire ropes exchange period and could competitive power. Also, this system is possible to apply in several field such as elevator, lift and so on.

The Change of Collected Light According to Changing of Reflectance and Thickness of CdWO4 Scintillator for High Energy X-ray Imaging Detection (고에너지 X-선 영상검출을 위한 CdWO4 섬광체 두께와 반사체의 반사율 변화에 따른 광 수집량의 변화)

  • Lim, Chang Hwy;Park, Jong-Won;Lee, Junghee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.12
    • /
    • pp.1704-1710
    • /
    • 2020
  • The high-energy X-ray imaging detector used for container inspection uses a thick scintillator to effectively acquire X-rays. X-ray incident on the scintillator is generally up to 9MeV. Therefore, to effectively collect X-ray, it is necessary to use a thick scintillator. To collect the light generated by the reaction between X-ray and scintillator, an optical-sensor must be combined with the scintillator. In this study, a study on the design conditions of the detector using a CdWO4 and a small sensor is described. To calculate the collected light according to the change of the scintillator thickness and the reflectance of surface, MCNP6 and DETECT2000 were used. As a result of calculating, it was confirmed that when the reflectance of the surface was low, it was appropriate to select a scintillator with a thickness of 15 to 20-mm, but as the reflectance increased, it was confirmed that it was appropriate to select a CdWO4 with a thickness of 25 to 30-mm.

Effect of Methodologies for Laser-Induced Plasma Creation on Hydrogen Sensing (레이저 유도 플라스마 생성 방법이 수소 검출에 미치는 영향)

  • Jang, Jung-Ik;Kim, Ki-Bum
    • Transactions of the KSME C: Technology and Education
    • /
    • v.3 no.4
    • /
    • pp.291-297
    • /
    • 2015
  • As promising future energy source, hydrogen has been drawing much attention; however, it is easily leaked from the small gap in any storage container due to its find molecule size. In this study, Laser induced breakdown spectroscopy(LIBS) was used for hydrogen leak detection, and feasibility of the scheme was evaluated based on different way for plasma generation. Laser power of 295 mW was required for generating plasma on metal surface to measure hydrogen atomic emission while approximately 2.5 times higher laser power was needed for plasma formation directly in the hydrogen gas stream. It was shown that peak to base ratio increased linearly with increasing the concentration of hydrogen. It can be concluded that LIBS is a viable technique for hydrogen sensing when the concentration of hydrogen is less than 5%.

Immunogenicity of Recombinant Human Erythropoietin: Clinical Cases, Causes and Assays

  • Heo, Tae-Hwe;Kim, Young-Kwon;Yang, Seung-Ju;Cho, Hyun-Jeong;Kim, Sung-Jo
    • Biomedical Science Letters
    • /
    • v.15 no.2
    • /
    • pp.161-166
    • /
    • 2009
  • Human erythropoietin(EPO) is a glycoprotein that enhances red blood cell production by stimulating proliferation and differentiation of erythroid progenitor cells in the bone marrow. Patients with chronic kidney disease(CKD) suffer from anemia caused by reduced production of EPO in the kidney. Recombinant human EPO protein has been used successfully for the treatment of anemia associated with CKD. Recently, attention has been paid to the development of side effect of EPO, pure red cell aplasia(PRCA), in some patients with CKD. PRCA is a rare disorder of erythropoiesis that leads to a severe anemia due to an almost complete cessation of red blood cell production. EPO-related PRCA is caused by the production of EPO-neutralizing antibodies(Abs) that eliminate the biological activity of EPO as well as endogenous EPO in patients undergoing therapy. Since 1988, almost 200 cases worldwide have been reported with Ab-positive PRCA after receiving EPO therapeutics. The underlying mechanisms of the breaking of immune tolerance to self-EPO have been investigated. Modification of formulation, organic compounds of container closures, and route of administration has been suggested for the possible mechanism of increased immunogenicity of EPO. A number of assays have been used to detect Abs specific to EPO. These assays are generally grouped into two major categories: binding Ab assays and neutralizing Ab assays(bioassays). There are several types of binding Ab assays, including radioimmunoprecipitation assay, enzyme-linked immunosorbent assay, and the BIAcore biosensor assay. In vitro cell-based bioassays have been utilized for the detection of neutralizing Abs. Finally, the recent experience with anti-EPO Abs may have considerable implications for the future development and approval of EPO preparations. Also, considering that millions of patients are being treated with EPO, clinicians need to be aware of signs and consequences of this rare but severe clinical case.

  • PDF

Visualization and Image Processing for Measurement of Propagational Velocity of Shear Front (유동장의 이동속도측정을 위한 가시화 및 영상처리 방안)

  • Kim Jae-Won;Han Sang-Hoon;Ahn Eun-Young
    • Journal of Korea Multimedia Society
    • /
    • v.8 no.10
    • /
    • pp.1322-1328
    • /
    • 2005
  • The circulation flows passing through the Ekman boundary layer on the rotating disk and transfer the angular momentum into the interior region of the container. Consequently, the circulation enhances the momentum transfer and the interior fluid is divided by a propagating shear front. This investigation focuses on computer vision and image processing technique for analysis of Non-Newtonian Fluids. To visualize marching velocity shear front for the transient flow, a particular shaped particles and light are used. To validate the proposed method, quantitative image are compared with the optical data acquired by a direct measurement of LDV (Laser Doppler Velocimetry).

  • PDF

The Convergence Application Example of Non-destructive Inspection System (비파괴 검사 시스템의 융합 적용 사례)

  • Lee, Jeong-Ick
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.3
    • /
    • pp.191-197
    • /
    • 2017
  • This development is for non-destructive machine using X-Ray source about detecting outline faults of below middle size products. The differentiation is product of research and development unspecialized small and medium-sized products using X-Ray light sources can check real time if the surface of an external fault of radiation dose reference, within the leakage. The speed control is possible by software solution. In addition, we're working on possibly block doors for worker safety and equipment at the same time that inner drive can be identified in the image. These principles, as a key enabler of the current inspection system such as the container is small to medium-sized parts - a long way from utilization level is possible. This research will give rise to major effects for other various non-destructive market industries except car-industry. The most important fact is that this developed non-destructive machine is controlled below $0.2micro-S{\mu}v$.

Discriminant analysis of grain flours for rice paper using fluorescence hyperspectral imaging system and chemometric methods

  • Seo, Youngwook;Lee, Ahyeong;Kim, Bal-Geum;Lim, Jongguk
    • Korean Journal of Agricultural Science
    • /
    • v.47 no.3
    • /
    • pp.633-644
    • /
    • 2020
  • Rice paper is an element of Vietnamese cuisine that can be used to wrap vegetables and meat. Rice and starch are the main ingredients of rice paper and their mixing ratio is important for quality control. In a commercial factory, assessment of food safety and quantitative supply is a challenging issue. A rapid and non-destructive monitoring system is therefore necessary in commercial production systems to ensure the food safety of rice and starch flour for the rice paper wrap. In this study, fluorescence hyperspectral imaging technology was applied to classify grain flours. Using the 3D hyper cube of fluorescence hyperspectral imaging (fHSI, 420 - 730 nm), spectral and spatial data and chemometric methods were applied to detect and classify flours. Eight flours (rice: 4, starch: 4) were prepared and hyperspectral images were acquired in a 5 (L) × 5 (W) × 1.5 (H) cm container. Linear discriminant analysis (LDA), partial least square discriminant analysis (PLSDA), support vector machine (SVM), classification and regression tree (CART), and random forest (RF) with a few preprocessing methods (multivariate scatter correction [MSC], 1st and 2nd derivative and moving average) were applied to classify grain flours and the accuracy was compared using a confusion matrix (accuracy and kappa coefficient). LDA with moving average showed the highest accuracy at A = 0.9362 (K = 0.9270). 1D convolutional neural network (CNN) demonstrated a classification result of A = 0.94 and showed improved classification results between mimyeon flour (MF)1 and MF2 of 0.72 and 0.87, respectively. In this study, the potential of non-destructive detection and classification of grain flours using fHSI technology and machine learning methods was demonstrated.