• 제목/요약/키워드: contact wire

검색결과 327건 처리시간 0.025초

호남고속철도 전차선로의 이상 상태 분석 (Analysis for Catenary System with Focus on Abnomal Conditions on Honam High Speed Line)

  • 전재근;신승권;정호성;나경민;박영
    • 한국전기전자재료학회논문지
    • /
    • 제32권1호
    • /
    • pp.1-5
    • /
    • 2019
  • The overhead contact line (OCL) is a key piece of equipment for transmitting electrical energy to the pantograph of rail cars. Recently, a 400 km/h OCL was applied to the Honam high-speed line, and its performance was examined by running HEMU-430X. For the study, we analyzed the current of catenary wire concurrently while running HEMU-430X in the Honam high-speed line. Specifically, this study recorded the currents for each speed during operation of the railway vehicle. The analysis of the frequency of line current showed generation of third-harmonics, 15th-harmonics, 17th-harmonics, and 19th-harmonics. The current of catenary wire is a basic technology assessment used to determine the electrical safety of electric railway systems, and it can be used as a technology for analyzing circulating currents generated in the current configuration, as well as for analyzing electric fatigue of the OCL components.

최고운행속도 350km/h급 전차선로 최대경간길이 계산 기법 (Technique of Maximum Span Length Calculation for 350km/h High Speed Catenary System)

  • 창상훈;이기원;유향복
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.924-931
    • /
    • 2011
  • This paper deal with maximum span calculation technique for 350km/h high speed catenary system. Considers a geometric interaction, possible maximum span length is between two pole. Wind condition and the train current collector is moving even to being pantograph does not escape while operating. Uses like this justice and possible maximum span length is follow next condition. (i) Operating range of pantograph fan head, (ii) The wind velocity which assumes from system, (iii) Width in pantograph from operation height moving, (iv) Type of processing Catenary system, specially tensile strength of overhead contact wire and messenger wire etc. When accurately calculates the maximum permission span, the dropper between of overhead contact wire and messenger wire and must consider the correlation.

  • PDF

Effects of Cu Wire's Shape on the Plating Property of Sn-Pb Solder for Photovoltaic Ribbons

  • Cho, Tae-Sik;Chae, Mun-Seok;Cho, Chul-Sik
    • Transactions on Electrical and Electronic Materials
    • /
    • 제15권4호
    • /
    • pp.217-220
    • /
    • 2014
  • We studied the plating properties of Sn-Pb solder according to the shape of the Cu wire's cross-section for photovoltaic ribbon. The thickness of the Sn-Pb layer largely decreased to 29% on a curved Cu surface, compared to a flat Cu surface. This phenomenon is caused by the geometrical decrease in the contact angle of the liquid Sn-Pb solder and an increase in the surface energy of the solid/vapor on the curved Cu surface. We suggest a new ribbon's design where the Cu wire's cross-section is a semi-ellipse. These semi-ellipse ribbons can decrease the use of Sn-Pb solder to 64% and increase the photovoltaic efficiency, by reducing the contact area between the ribbon and cell, to 84%. We also see an improvement of reflectivity in the curved surface.

집전성능 향상을 위한 팬터그래프-전차선의 주요 설계 파라미터분석 (Analysis of the Major Design Parameters of a Pantograph-Railway Catenary System for Improving the Current Collection Quality)

  • 조용현
    • 한국철도학회논문집
    • /
    • 제17권1호
    • /
    • pp.7-13
    • /
    • 2014
  • 팬터그래프와 전차선 사이의 이선을 유발하는 주요 요인은 팬터그래프로 인하여 전차선에 야기되는 파동의 전파와 반사 그리고 열차 진행방향의 전차선로 강성변화이다. 본 논문의 목적은 200km/h급 일반철도와 300km/h급 고속철도에서 이선을 효과적으로 줄이기 위하여 앞서 언급하였던 두 가지 요인 중에서 어느 쪽을 중요하게 고려해야 하는지를 분석하는 것이다. 고속철도 경우에는 파동의 전파와 반사가 강성 변화에 비하여 집전성능에 영향을 더 크게 미친다. 증속을 위해서는 드로퍼 경량화와 전차선 고 장력 부여를 위한 고 강도 전차선 개발이 필요하다. 파동전파속도를 향상하기 위하여 조가선의 장력을 증가시키면 오히려 집전성능을 악화할 수 있음에 유의해야 한다. 200km/h급 일반철도의 경우에는 전차선로 강성 변화가 파동 전파 및 반사에 비하여 집전성능에 영향을 더 미치므로 강성변화를 완화시키기 위하여 경간길이 축소, 전차선로의 장력 증가 및 드로퍼배치 최적화가 필요하다.

전기철도의 전력선 통신망 설계에 관한 연구 (A Study on the Network Design of Electric Railway for Power Line Communication)

  • 김재문;김양수;안승호;이희준;이종구
    • 한국산학기술학회논문지
    • /
    • 제11권10호
    • /
    • pp.3756-3760
    • /
    • 2010
  • 본 논문은 조가선을 이용한 전기철도의 전력선 통신을 위한 네트워크 설계를 제안한다. 전기철도에서 필수적인 전차선 및 조가선을 이용하여 전력선 통신에 대한 타당성 검토를 선행연구로 수행하였다. 이를 위해 우선 무가압상태에서 조가선에 신호결합기를 취부하여 양방향 데이터 통신을 구현하였다. 데이터 전송속도가 양호하게 나타났으며 이를 토대로 전력선 통신을 위한 주요 구성품을 제시하고 네트워크 설계를 제안하였다. 향후 네트워크 설계에 대한 타당성을 확보하기 위해 지속적인 연구를 수행하고자 한다.

전기철도 강체전차선로의 정적 상태 검출 기술 연구 (A Study on Technologies for Measuring Static Condition of Rigid Conductor System in Railway Electrification)

  • 나경민;이기원;박영
    • 한국전기전자재료학회논문지
    • /
    • 제32권6호
    • /
    • pp.507-511
    • /
    • 2019
  • The purpose of an electric railway system contact wire is to supply electric energy to trains through a contacted pantograph. This energy is then converted into mechanical energy. Recent developments in overhead contact lines include the increase in the tension force up to 34 kN according to train speeds that reach up to 400 km/h with a verified safety. Rigid conductor catenary (R-Bar) for high speeds of up to 250 km/h have been developed in tunnels to save on construction costs. This is significant because minor defects in R-bars in aspects, such as height and stagger affect installation conditions. In this study, we propose the use of a detector that measures the static characteristics to reduce the R-bar installation errors. This detector has been developed to measure the height and stagger of the contact wire using video images.

장력조정장치의 동작에 영향을 미치는 가선저항의 사례 (Examples of Trolley Wire Resistance Influential on The Movement of Tensioning Devices)

  • 윤용한;임금광;한양규
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.886-892
    • /
    • 2007
  • This paper presents examples of trolley wire resistance influential on the movement of tensioning devices. Therefore, this study is on the examples of trolley wire resistance which keep tensioning devices from working properly to the expansion and contraction in accordance with temperature change of overhead trolley wire system such as messenger wire and contact wire. Trolley wire resistance interrupts the working of tensioning device and drops the capacity of trolley wire. Reduced trolley wire capacity lowers the performance of current collection and has a bad effect on electrical train operation. So it is desirable to reduce the factors increasing trolley wire resistance to the minimum from the designing and construction stage of overhead trolley wire system. This study will introduce this problem and suggest the solution.

  • PDF

집전시스템의 동적 수치모의 해석에 관한 연구 (A Study on a dynamic simulation of Current Collection System)

  • 허신;경진호;;송달호;박성훈;김정수
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1999년도 춘계학술대회 논문집
    • /
    • pp.151-158
    • /
    • 1999
  • In this study, we developed the simulation program of an overhead catenary-pantograph system, The overhead catenary is modeled with point mass and the pantograph is replaced with 3 d. o. f. model which is composed of mass, spring and damper. Using the developed program, we analyzed the static structure of the overhead catenary and the dynamic characteristics of an overhead catenary-pantograph system such as uplift displacement of contact wire and contact force. we compared the analysis results with the results of GASENDO software developed at RTRI in Japan. The behaviors of uplift displacement of contact wire and contact force were similar with the results of GASENDO software.

  • PDF

광계측기를 이용한 전차선-팬터그래프 재질별 이선아크 스펙트럼 분석 (Analysis of Contact Loss Arc Spectrum between Contact Wire and Pantograph Material using a Spectrometer)

  • 장진영;정노건;박종국;구경완;김재문
    • 전기학회논문지
    • /
    • 제62권12호
    • /
    • pp.1803-1808
    • /
    • 2013
  • To maintain contact between catenary and pantograph copper is important in order to transmit power smoothly on Current collection system. But, Arc discharge with strong light is generated because of contact loss. Therefore, Arc discharge detection is important measurement factor judging performance of current collection system. In this paper, It is described to results of arc discharge applying UV detection technology using arc generator. And Arc discharge was detected using the most commonly used processing catenary and rigid catenary and pantograph copper of electric rolling stock for securing arc detection instrument reliability. Results of contact loss detection instrument in this paper will be used for maintenance of current collection quality and system.

배선에서의 반단선 및 접촉불량에 대한 열적 전조 DB구축 (Development of Thermal Precursor DB for Partial Disconnection and Poor Contact on Electrical Wire)

  • 김두현;김성철;이종호;강동규
    • 한국안전학회지
    • /
    • 제24권2호
    • /
    • pp.30-36
    • /
    • 2009
  • This paper aims at the precursor analysis and DB development of electrical fires based on thermal and current signals for partial disconnection and poor contact on electric wires through experiments and simulations. Also, DB system required for developing the precursor DB with these data was studied and designed. Firstly, in case of partial disconnection, characteristics were derived and analyzed by experiment and electrical-thermal finite element method(Flux 3D) on the model wires which consist of VCTF and IV electric wires. Based on the characteristics, About 351 partial disconnection precursor patterns were generated by the thermal analysis for electric wire according to deterioration time under normal state and 200% overload state of rated current. Secondly, in order to develop poor contact precursor patterns, temperature value and the current signal were considered. In simulating the poor contact situation on connector area of MCCB, connection torque was changed. Through the experimental analysis, about 251 poor contact precursor patterns were generated. Finally, Using thermal precursor patterns obtained by partial disconnection and poor contact, electrical fire thermal precursor DB was developed.