하우징 형태(Housing Type)로 제작된 배선 연결 커넥터의 안전성 평가에 관한 연구 (A Study on the Safety Estimation of Wiring Connection Connector Manufactured by Housing Type)

  • 최충석
    • 전기학회논문지P
    • /
    • 제59권4호
    • /
    • pp.462-466
    • /
    • 2010
  • The purpose of this study is to evaluate the safety of a wire connector fabricated for the effective installation of a lighting fixture including its contact resistance, insulation resistance, withstanding voltage characteristics, etc., and to provide the basis for the analysis and judgment of PL(Product Liability) dispute by presenting a damage pattern due to a general flame and overcurrent. This study applied the Korean Standard (KS) for the incombustibility test of the connector using a general flame and performed an overcurrent characteristics test of the connector using PCITS (Primary Current Injection Test System). The contact resistance of the housing connector was measured using a high resistance meter and the insulation resistance was measured using a multimeter. In addition, a supply voltage of AC 1,500V for testing the withstanding voltage characteristics was applied to both ends of the connector. Measurement was performed on 5 specimens and the measured values were used as a basis for judgment. Since the connector is fabricated in the form of a housing, it can be connected and separated easily and has a structure that allows no foreign material to enter. In addition, since it has a structure that allows wires to be connected only when their polarity is identical, any misconnection that may occur during installation can be prevented. When the incombustibility test was performed by applying a general flame to the connector, it showed outstanding incombustibility characteristics and the blade and blade holder connected to the housing remained firmly secured even after the insulation sheath (PVC) was completely destroyed by fire. In addition, the mechanism of the damaged connecting wire showed a comparatively uniform carbonization pattern and it was found that some residual melted insulation material was attached to both ends. In the accelerated life test (ALT) to which approximately 500% of the rated current was applied, the connector damage proceeded in the order of white smoke generation, wire separation, spark occurrence and carbonization. That is, it could be seen that the connector damaged by overcurrent lost its own metallic color with traces of discoloration and carbonization. The contact resistance of the connector at a normal state was 2.164mV/A on average. The contact resistance measured after the high temperature test was 3.258mV/A. In addition, the insulation resistance after the temperature test was completed was greater than $10G\Omega$ and the withstanding voltage test result showed that no insulation breakdown occurred to all specimens showing stable withstanding voltage and insulation resistance characteristics.

A Study on the Measurement of Contact Force of Pantograph on High Speed Train

  • Seo Sung-Il;Cho Yong-Hyun;Mok Jin-Yong;Park Choon-Soo
    • Journal of Mechanical Science and Technology
    • /
    • 제20권10호
    • /
    • pp.1548-1556
    • /
    • 2006
  • Appropriate contact force is required for the pantograph on the high speed train to collect current from the catenery system without separation. However, at high speed, large aerodynamic lifting force is generated by the contact plate and the body of pantograph, which may cause wear of the contact wire. In this study, to confirm the interface performance of the pantograph on Korea High Speed Train, a method to measure the contact force of the pantograph was proposed and the related measuring system was developed. The forces acting on the pantograph were clarified and a practical procedure to estimate the forces was proposed. A special device was invented and applied to measure the aerodynamic lifting force. Measured contact forces were displayed by the developed system and evaluated based on the criteria.

Fabrication of Ordered One-Dimensional Silicon Structures and Radial p-n Junction Solar Cell

  • Kim, Jae-Hyun;Baek, Seong-Ho
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제43회 하계 정기 학술대회 초록집
    • /
    • pp.86-86
    • /
    • 2012
  • The new approaches for silicon solar cell of new concept have been actively conducted. Especially, solar cells with wire array structured radial p-n junctions has attracted considerable attention due to the unique advantages of orthogonalizing the direction of light absorption and charge separation while allowing for improved light scattering and trapping. One-dimenstional semiconductor nano/micro structures should be fabricated for radial p-n junction solar cell. Most of silicon wire and/or pillar arrays have been fabricated by vapour-liquid-solid (VLS) growth because of its simple and cheap process. In the case of the VLS method has some weak points, that is, the incorporation of heavy metal catalysts into the growing silicon wire, the high temperature procedure. We have tried new approaches; one is electrochemical etching, the other is noble metal catalytic etching method to overcome those problems. In this talk, the silicon pillar formation will be characterized by investigating the parameters of the electrochemical etching process such as HF concentration ratio of electrolyte, current density, back contact material, temperature of the solution, and large pre-pattern size and pitch. In the noble metal catalytic etching processes, the effect of solution composition and thickness of metal catalyst on the etching rate and morphologies of silicon was investigated. Finally, radial p-n junction wire arrays were fabricated by spin on doping (phosphor), starting from chemical etched p-Si wire arrays. In/Ga eutectic metal was used for contact metal. The energy conversion efficiency of radial p-n junction solar cell is discussed.

  • PDF

카본열선을 사용하는 전기장판의 국부가열에 의한 화재원인 분석 (Fire Cause Analysis of Local Heating on Carbon Type Hot Wire Electric Pad)

  • 송재용;김진표;남정우;사승훈
    • 한국화재소방학회논문지
    • /
    • 제24권4호
    • /
    • pp.104-108
    • /
    • 2010
  • 본 논문은 카본열선을 사용하는 전기장판에서 발생한 전기화재에 관하여 기술하였다. 카본열선을 사용하는 전기장판은 카본 재질의 특성상 전기용접이나 납땜 등의 방법으로 접속이 불가능하며, 열선 끝단을 카본 재질의 연결부를 만들어 접속해야 한다. 이러한 과정에서 열선 사이의 불완전 접속이 발생되며, 불완전 접속부에는 접촉저항의 증가로 국부적인 발열이 발생되고, 최종적으로 화재사고로 진전된다. 본 논문에서는 카본 열선 접속부에서 불완전 접속이 형성되는 경우, 접속부에서 전기적 발열에 의해 발생되는 열선의 손상 형태를 분석하여 화재원인을 규명하였다. 이러한 분석 결과는 카본 열선을 사용하는 전기장판의 화재원인 조사의 기초 자료로 활용 가능할 것으로 기대한다.

팬터그래프와 전차선간 최소 이선아크 지속시간에 따른 이선율 변화량 분석 (Analysis of Percentage of Arcing between Pantograph and Overhead Contact Line as a Function of Duration of Arc)

  • 박영;이기원;권삼영;박철민;김재광;최원석
    • 전기학회논문지
    • /
    • 제63권6호
    • /
    • pp.855-859
    • /
    • 2014
  • Quality criteria for interaction between a pantograph and overhead contact wire is a most important requirement to assess of the performance for the current collection system. Interaction performance between pantograph and catenary system is subject to approval by the infrastructure manager when a new design and contraction of overhead contact line and pantograph are installed. Among the various performance, percentage of arcing at maximum line speed is a simple test method compared with contact force of pantograph due to direct sensing of pantagraph, calibrations, installations of train, and etc. On the other hand, percentage of arcing is need to reliable arcing detector and general requirements with accordance with EN 50317. In this paper, percentage of arcing are investigated on the function of duration of arc and proposed which is satiable of percentage of arcing. As a results, we proposed which duration of arcs are unsuitable from infrastructures point of view as performance testing for quality of current collection.

강수의 영향에 따른 Pantograph 주습판의 마모특성 분석 (Analysis on Wearing Characteristics of Main Wearing Slider for Pantograph According to Precipitation)

  • 김경섭;김관수;조관현
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.994-999
    • /
    • 2011
  • The main wearing slider of pantograph is a difference which is considerable to wear phenomenon according to material properties. Especially, Cu-type wearing slider suddenly occurs the abnormal wear by precipitation, this threatens the travelling safety of the train. The abnormal wear by precipitation and arc influences are main factor decided to life time of Cu-type wearing slider and contact wire. Consequently, the application of the main wearing slider with wear resisting capacity, electrical conductivity, resistance arc and lubrication is demanded. In this paper through tribologic approach, overcame abnormal phenomenon of the Cu-type wearing slider by the precipitation and for the economic efficient augmentation by durability improvement and the travelling safety were accomplished. The Cu-type wearing slider which has excellent electric conductivity and arc characteristic but it occurs the normal and abnormal wear phenomenon according the precipitation which changes, respectively. Consequently, this phenomenon grasps fixed quantity according to precipitation, a mileage and wear volume then Fe-type wearing slider compared and analyzed.

  • PDF

비접촉식 전류 검출 장치에 관한 연구 (A Study on the Current Detector with Non Contact Type)

  • 김기준
    • 한국전기전자재료학회논문지
    • /
    • 제31권5호
    • /
    • pp.351-356
    • /
    • 2018
  • Commonly, a live-line alarm can be used to measure the electric field strength of a high-voltage system to calculate its current, but it is hard to detect the electric field of shielded cables or concealed structures, such as underground distribution cables. Current sensors can detect the magnetic field in a single core wire, but they cannot determine the magnetic field about a double-core wire because the currents flow in opposite directions. Therefore, it is very difficult to detect certain current problems, such as a fault current in an extension line comprised of a double line. In this paper, to ultimately develop a sensor that can detect the current regardless of line conditions, we used a simulation to determine the concentration of the magnetic field dependent on the distribution of the external magnetic field and the path of each line's core.

3상 전기제어반 전기사고 예방을 위한 계측시스템 설계 (An Instrumentation System Design for Electrical Accident Prevention of 3-Phase Electrical Control Panel)

  • 곽동걸;최정규;김재중;권영준;송강
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2016년도 전력전자학술대회 논문집
    • /
    • pp.36-37
    • /
    • 2016
  • The main cause of electrical fires are caused due to short circuit and open circuit. This is generates an instantaneous electric arc or spark accompanied with such electric faults. These arcs generate a pressed wire, contact badness, and a weakness in the wire coating etc.. This research proposes a protection circuit to prevent open-phase accident due to contact failure of electromagnetic contactor, tracking arc fault, open-phase within the three-phase electrical control panel which is the most commonly applied in the industry. The proposed circuit also alarms and cuts off of power system when electrical faults occurs. In addition, the proposed circuit is validated by various electric accident simulator.

  • PDF

자동운전 도시철도차량의 운전특성을 고려한 절연구분장치 이론적 고찰 (Theoretical Study of Neutral Section Considering the Driving Characteristics of ATO Urban Railway Vehicle)

  • 이재봉;김재문
    • 전기학회논문지
    • /
    • 제62권10호
    • /
    • pp.1470-1474
    • /
    • 2013
  • In this paper, proper length of neutral section and neutral section system configuration is proposed to minimize accidents if ATO urban railway vehicle stops maintaining the leading vehicles in air section at regular intervals. When considering the minimum voltage sensing of power conversion unit in the urban railway vehicle, the effective length of 14,280[mm] with neutral section can be minimized damage due to high current because the urban railway vehicle is very little present chance compare neutral section with pantograph interval installed on a unit vehicle. In addition, uplift of catenary line and contact wire consider to minimize damage. The result of theoretical review, as the proposed neutral section shorter, isolated neutral section is effective than the integrated neutral section.

강체전차선방식(AL T-Bar)에서의 Expansion joint 및 Air Section 설비 개량방안 연구 (A Study of Equipment Improvment method of the Expansion joint & Air Section in Rigid Trolley Bar System (AL T-Bar))

  • 유정상;장우진;이병송
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2003년도 추계학술대회 논문집(III)
    • /
    • pp.523-528
    • /
    • 2003
  • AS City traffic means, the electric railway of the role is overwhelming with recognizing good merits of safety, no environment disruption and accurate destination time. Currently, Korea subway are running about 290km through eight subway lines. The latest constructed subway had been made by imperoved matherials which is going on improving. Therefore, we researched this project to keep up facilites easily, repress a leakge current and reduse install cost and repair time in changing facility at overhead Contact wire system because of arc by reforming construction plan about Expansion Joint and Air Section which is regarded as weak point when facilities are fixed and maintianed of Rigid Trolley bar System. as above we can contribute various part to making useful O.C.S(overhead contact wire system)

  • PDF