• Title/Summary/Keyword: contact sensitivity

Search Result 253, Processing Time 0.029 seconds

Reduction of the Roll-Over of the Sector Tooth for Achieving Improved Recliner Locking Performance (리클라이너 결합 성능 향상을 위한 섹터투스의 롤오버 저감 방법)

  • Lee, Sang-Hoon;Choi, Hong-Seok;Chang, Myung-Jin;Kim, Dong-Su;Bae, Jae-Ho;Ko, Dae-Cheol;Kim, Byung-Min
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.11
    • /
    • pp.1623-1630
    • /
    • 2010
  • In this study, effective forming methods for reducing the roll-over of a sector tooth, which is a main component of an automotive seat recliner, are proposed. Due to the large amount of roll-over, accurate contact between the inner gear of a sector tooth and the outer gear of a pawl tooth cannot be normally achieved; thus sensitivity and safety for the passengers decrease. To overcome the aforementioned drawback, we investigated the effect of flowcontrol forming methods involving local embossing die, coining punch, and VIC (Variable Inverse Clearance) on the roll-over depth by FE-analysis and an experiment. The results of a fine-blanking experiment for verifying the proposed methods showed that VIC type is decidedly superior from the aspects of reduction of roll-over and tool strength of the sector tooth.

Development of electric safety control system for incapable operation of ELB and MCB using the low voltage distribution line (저압 배전선로의 누전 및 배선용 차단기의 오동작 방지를 위한 전기안전 제어장치 개발)

  • Kwak, Dong-Kurl;Shin, Mi-Young;Jung, Do-Young;Kim, Hyo-Jin;Baek, Seong-Hyun;Choi, Byung-Seub
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.371-372
    • /
    • 2007
  • The major causes of electrical fire are classified to short circuit fault, overload fault, electric leakage and electric contact failure. The occurrence factor of the fire is electric arc or spark accompanied with electrical faults. Residual Current Protective Device (RCD), that is Earth Leakage Circuit Breaker(ELB) and Molded_case Circuit Breaker (MCB), of high sensitivity type used at low voltage wiring cuts off earth leakage and overload, but the RCD can't cut off electric arc or spark to be a major factor of electrical fire. As the RCDs which are applied low voltage distribution panel are prescribed to rated breaking time about 30[ms] (KS C 4613), the RCDs can't perceive to the periodic electric arc or spark of more short wavelength level. To be improved on such problem, this research development is proposed to a auxiliary control apparatus for RCD trip on electric arc or spark due to electrical fire. Some experimental results of the proposed apparatus is confirmed to the validity of the analytical results.

  • PDF

Measurement of rivulet movement and thickness on inclined cable using videogrammetry

  • Jing, Haiquan;Xia, Yong;Xu, Youlin;Li, Yongle
    • Smart Structures and Systems
    • /
    • v.18 no.3
    • /
    • pp.485-500
    • /
    • 2016
  • Stay cables in some cable-stayed bridges suffer large amplitude vibrations under the simultaneous occurrence of rain and wind. This phenomenon is called rain-wind-induced vibration (RWIV). The upper rivulet oscillating circumferentially on the inclined cable surface plays an important role in this phenomenon. However, its small size and high sensitivity to wind flow make measuring rivulet size and its movement challenging. Moreover, the distribution of the rivulet along the entire cable has not been measured. This paper applies the videogrammetric technique to measure the movement and geometry dimension of the upper rivulet along the entire cable during RWIV. A cable model is tested in an open-jet wind tunnel with artificial rain. RWIV is successfully reproduced. Only one digital video camera is employed and installed on the cable during the experiment. The camera records video clips of the upper rivulet and cable movements. The video clips are then transferred into a series of images, from which the positions of the cable and the upper rivulet at each time instant are identified by image processing. The thickness of the upper rivulet is also estimated. The oscillation amplitude, equilibrium position, and dominant frequency of the rivulet are presented. The relationship between cable and rivulet variations is also investigated. Results demonstrate that this non-contact, non-intrusive measurement method has good resolution and is cost effective.

A New X-Ray Image Sensor Utilizing a Liquid Crystal Panel (새 구조의 액정 엑스선 감지기)

  • Rho, Bong-Gyu
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.4
    • /
    • pp.249-254
    • /
    • 2008
  • We developed a new x-ray image sensor utilizing a reflection-mode liquid crystal panel as its sensitive element, and tested its functionality by using it to obtain an x-ray image of a printed circuit board. In the liquid crystal x-ray image sensors hitherto reported, the liquid crystal layer is in direct contact with the photoconductive film which is deposited on a glass substrate. In the fabrication of the new x-ray image sensor, a liquid crystal panel is fabricated in the first step by using a pair of glass plates of a few centimeters thicknrss. Then one of the glass substrates is ground until its thickness is reduced to about $60\;{\mu}m$. After polishing the glass plate, dielectric films for high reflectance at 630 nm, a film of amorphous selenium for photoconduction, and a transparent conductive film for electrode are deposited in sequence. The new x-ray image sensor has several merits: primarily, fabrication of a large area sensor is more easily compared with the old fashioned x-ray image sensors. Since the reflection type liquid crystal panel has a very steep response curve, the new x-ray sensor has much more sensitivity to x-rays compared with the conventional x-ray area sensor, and the radiation dosage can be reduced down to less then 20%. By combining the new x-ray sensor with CCD camera technology, real-time x-ray images can be easily captured. We report the structure, fabrication process and characteristics of the new x-ray image sensor.

Development of Evaluation Model of Pumping and Drainage Station Using Performance Degradation Factors (농업기반시설물 양·배수장의 성능저하 요인분석 및 성능평가 모델 개발)

  • Lee, Jonghyuk;Lee, Sangik;Jeong, Youngjoon;Lee, Jemyung;Yoon, Seongsoo;Park, Jinseon;Lee, Byeongjoon;Lee, Joongu;Choi, Won
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.4
    • /
    • pp.75-86
    • /
    • 2019
  • Recently, natural disasters due to abnormal climates are frequently outbreaking, and there is rapid increase of damage to aged agricultural infrastructure. As agricultural infrastructure facilities are in contact with water throughout the year and the number of them is significant, it is important to build a maintenance management system. Especially, the current maintenance management system of pumping and drainage stations among the agricultural facilities has the limit of lack of objectivity and management personnel. The purpose of this study is to develop a performance evaluation model using the factors related to performance degradation of pumping and drainage facilities and to predict the performance of the facilities in response to climate change. In this study, we focused on the pumping and drainage stations belonging to each climatic zone separated by the Korea geographical climatic classification system. The performance evaluation model was developed using three different statistical models of POLS, RE, and LASSO. As the result of analysis of statistical models, LASSO was selected for the performance evaluation model as it solved the multicollinearity problem between variables, and showed the smallest MSE. To predict the performance degradation due to climate change, the climate change response variables were classified into three categories: climate exposure, sensitivity, and adaptive capacity. The performance degradation prediction was performed at each facility using the developed performance evaluation model and the climate change response variables.

A Case study of engineering comprehensive design subject incorporating convergence with art (예술과의 융합을 접목한 공학 종합설계 교과목 사례연구)

  • Huh, Wonwhoi
    • Journal of the Korea Convergence Society
    • /
    • v.13 no.4
    • /
    • pp.195-201
    • /
    • 2022
  • The core of the Fourth Industrial revolution, the topic of the 21st century, lies in the convergence of various technologies that are developing to the cutting edge. Therefore, convergence education is essential to solve problems from various perspectives. Above all, in order to solve the complex problem arising from the contact point between humans and technology in the future society, it was considered that insight through a humanities and artistic approach was necessary. Now, universities are trying to run a multidisciplinary comprehensive design to adapt to the new digital environment. In this study, an operation case of an engineering comprehensive design subject incorporating art operated by a researcher was described. The researcher presented an art convergence curriculum in a comprehensive design subject by applying 1. problem recognition and definition, 2. idea derivation and evaluation, 3. project development, 4. presentation, and demonstration process operation methods. Through this study, it is meaningful that it presented a method of operating art convergence in engineering comprehensive design subjects by allowing students to attempt an artistic aesthetic and emotional approach to project development.

Sealing design optimization of nuclear pressure relief valves based on the polynomial chaos expansion surrogate model

  • Chaoyong Zong;Maolin Shi;Qingye Li;Tianhang Xue;Xueguan Song;Xiaofeng Li;Dianjing Chen
    • Nuclear Engineering and Technology
    • /
    • v.55 no.4
    • /
    • pp.1382-1399
    • /
    • 2023
  • Pressure relief valve (PRV) is one of the important control valves used in nuclear power plants, and its sealing performance is crucial to ensure the safety and function of the entire pressure system. For the sealing performance improving purpose, an explicit function that accounts for all design parameters and can accurately describe the relationship between the multi-design parameters and the seal performance is essential, which is also the challenge of the valve seal design and/or optimization work. On this basis, a surrogate model-based design optimization is carried out in this paper. To obtain the basic data required by the surrogate model, both the Finite Element Model (FEM) and the Computational Fluid Dynamics (CFD) based numerical models were successively established, and thereby both the contact stresses of valve static sealing and dynamic impact (between valve disk and nozzle) could be predicted. With these basic data, the polynomial chaos expansion (PCE) surrogate model which can not only be used for inputs-outputs relationship construction, but also produce the sensitivity of different design parameters were developed. Based on the PCE surrogate model, a new design scheme was obtained after optimization, in which the valve sealing stress is increased by 24.42% while keeping the maximum impact stress lower than 90% of the material allowable stress. The result confirms the ability and feasibility of the method proposed in this paper, and should also be suitable for performance design optimizations of control valves with similar structures.

Evaluation of the Clinical Usefulness of the Xeniss Rapid TB kit for the Diagnosis of Tuberculosis (결핵진단에서 Xeniss Rapid TB kit의 임상적 유용성)

  • Park, Seung-Kyu;Lee, Woo-Chul;Hwang, Soo-Hee;Kwon, Eun-Si;Lee, Hung-Soon;Lee, Duk-Hyoung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.4
    • /
    • pp.389-400
    • /
    • 2002
  • Background : The rapid diagnostic tests for tuberculosis are needed to facilitate early treatment of tuberculosis and prevention of Mycobacterium tuberculosis transmission. The Xeniss Rapid TB kit is a rapid, card-based immunochromatographic test for the detection of antibodies directed against M. tuberculosis antigens including antigen 5(38-kDa antigen). The objective of this study was to evaluate the performance of the Xeniss Rapid TB kit for the diagnosis of active tuberculosis with serums from patients, asymptomatic healthy and close contact controls. Methods : 188 patients with active tuberculosis were tested; 177 with pulmonary tuberculosis(18 with combined pleurisy), and 11 with extrapulmonary tuberculosis. The control groups were composed of 82 close contacts and 57 healthy adults. Study subject were drawn from one national tuberculosis hospital for patients and close contacts, and another private hospital for healthy adults in Masan city, Korea. The Xeniss Rapid TB kit(Xeniss Life Science Co., Ltd., Seoul, Korea) was evaluated by using serum samples according to the instructions of the manufacturer by an investigator masked to the clinical and microbiological status of the study subjects. Results : The diagnostic sensitivity of the Xeniss Rapid TB kit was 73.9% in patients and specificities were 73.2% and 93.0% in close contact and healthy adults respectively. The positive predictive value in patients was 84.2% and the negative predictive value in controls was 85.8%. Conclusion : This study shows that the Xeniss Rapid TB test is a simple and fast method to diagnose active TB. The results of the sensitivity and specificites suggest that serodiagnosis using this point of care testing(POCT) device would be valuable and advantageous for screening tuberculosis in the clinical field.

Analytical Method Development of 2,6-dimethylnaphthalene Dicarboxylate (2,6-NDC) and 2,6-naphthalene Dicarboxylic Acid (2,6-NDA) in Poly (ethylene naphthalate) (PEN) (Poly (ethylene naphthalate) (PEN 수지)의 2,6-디메틸나프탈렌 디카복실레이트 (2,6-NDC)과 2,6-나프탈렌디카복실산(2,6-NDA) 분석법 확립)

  • Sung, Jun-Hyun;Oh, Jae-Myoung;Shin, Dong-Woo;Choi, Jae-Chon;Lim, Ho-Soo;Park, Se-Jong;Park, Geon-Woo;Kim, So-Hee;Kim, Meehye
    • Journal of Food Hygiene and Safety
    • /
    • v.28 no.1
    • /
    • pp.56-62
    • /
    • 2013
  • Poly (ethylene naphthalate) (PEN), which is likely to be widely used in various application due to good barrier properties, is manufactured by condensation polymerization of 2,6-dimethylnaphthalene dicarboxylate (2,6-NDC) or 2,6-naphthalene dicarboxylic acid (2,6-NDA) with ethylene glycol. In this study, an analytical method to determine monomers in food simulants, which might migrate from PEN food contact materials into food, was developed. The HPLC-UV method was validated for 2,6-NDC and 2,6-NDA. The obtained validation parameters were selectivity, sensitivity, linearity, precision and recovery. The simultaneous HPLC method was considered the be most effective analytical method to determine 2,6-NDC and 2,6-NDA in food simulants.

Guideline of Improvement and Evaluation of Prescribing Errors in Colorectal Chemotherapy (대장암 항암 화학요법의 처방 오류 평가 및 개선안 제시)

  • Lim, Hyun-Soo;Lim, Sung Cil
    • Korean Journal of Clinical Pharmacy
    • /
    • v.23 no.2
    • /
    • pp.158-166
    • /
    • 2013
  • Background: Colorectal cancer shows a significant increase in South Korea due to westernization of diet, lack of dietary fiber, drinking and smoking, irregular defecation. There are surgery, chemotherapy, radiation therapy in treatment of colorectal cancer. There may be a medication errors in the process of chemotherapy because of its high toxicity, narrow therapeutic index and the health status of cancer patients. Consequently medication errors can cause increasing the risk of death, prolonging hospital stay and increasing the cost. Among medication errors on medication use process, prescribing errors are of particular concern due to higher risk of serious consequences. It is important for pharmacist to prevent the prescribing errors before reaching patient. Therefore we analyzed the prescriptions of colorectal cancer, classified prescribing errors, suggested guideline to reduce prescribing errors and verified the importance of pharmacist's role in prevention of medication errors activity. Methods: We collected the numbers of prescriptions of colorectal cancer(n=2,373) through anti cancer management program and EMR and analyzed the errors of prescriptions by categories from Oct 1st 2011 to Sep 30th 2012 at Chungbuk National University Hospital. We reviewed the prescriptions as follows - patients' characteristics, the result of test, previous prescriptions, characteristics of antineoplastic agents and patients' allergy, drug sensitivity, adverse events. Prescriptions are classified into inpatient and outpatient and analyzed the errors of prescriptions by categories (dosage form, dose, input, diluents, regimen, product). Results: Total prescription number of inpatient and outpatient of colorectal cancer was 1,193 and 1,180 and that of errors was 107(9%) and 22(1.9%), respectively. In case of errors of categories, the number of errors of dosage form is 69 and 8, errors of dose is 15 and 5, errors of input is 9 and 9 in inpatient and outpatient prescriptions, respectively. Errors of diluents is 8, errors of regimen is 3, errors of product is 3 in only inpatient prescriptions. In case of errors of categories by inpatient department, the number of errors of dosage form is 34 and 35, errors of dose is 7 and 8, errors of input is 6 and 3, errors of diluents is 4 and 4, errors of regimen is 2 and 1, errors of product is 2 and 1 in SG and HO, respectively. In case of outpatient department, the number of errors of dosage form is 8 in HO, errors of dose is 5 in HO, errors of input is 5 and 4 in SG and HO, respectively. Conclusions: The rate of errors of inpatient is higher than that of outpatient. Junior doctors are engaged in prescriptions of inpatient and pharmacist need to pay attention to review all prescriptions. If prescribing errors are discovered, pharmacist should contact the prescriber and correct the errors without delay. The guideline to reduce prescribing errors might be upgrading software of anti cancer management program, education for physicians as well as pharmacists and calling prescriber's attention to preventing recurrence of errors.