• 제목/요약/키워드: contact material and area

검색결과 324건 처리시간 0.029초

가변형 치과 인상용 트레이의 적합도에 관한 예비연구 (A Preliminary Study on the Fitness of Adjustable Dental Impression Trays)

  • 김민정;오상천;동진근
    • 구강회복응용과학지
    • /
    • 제21권1호
    • /
    • pp.83-93
    • /
    • 2005
  • This study was designed to investigate the fitness of adjustable dental impression trays. The size and shape of these trays were designed from the results of the dental arch size of Korean adults. Tray samples were made by CAD-CAM working. A hundred dental students(male:50, female:50) were selected for taking irreversible hydrocolloid impression using these trays. The author measured the width and length of impression material on the several measuring points. The results obtained were as follows : 1. Uniform impression material thickness was achieved by controlling the width of the tray using stops and beveled guides. 2. In the upper tray, the impression material thickness was measured to be rather great showing thickness of the labial vestibule 8.3 mm and the midpalatal part 8.6 mm. 3. In the lower tray, length of the impression material of the labial vestibule of first, second premolar contact point was 7.8 mm, and thickness of the lingual part of premolars(1.8 mm) and molars(1.9 mm) showed small values. 4. In the lower tray, the impression material thickness of the buccal shelf area(0.2 mm) and the retromolar pad area(0.6 mm) was measured to be too small.

임플란트 보철의 교합 접촉 변화에 대한 임상적 평가 (Clinical Evaluation of Occlusal Contact Changes in Implant Prosthesis)

  • 윤철희;김대곤;이양진;조리라;박찬진
    • 구강회복응용과학지
    • /
    • 제23권1호
    • /
    • pp.21-30
    • /
    • 2007
  • Despite of the successful clinical performance of implants, it is still lacking of the knowledge of changes in implant occlusion. The purpose of this study was to evaluate the changes of infraocclusal contact after clinical occlusal function of implant. Twenty patients(38 implants) were recalled during 10 months after placement of implant prosthesis. Occlusion changes were investigated at placement, placement 1 months, 4 months and 10 months serially with silicone bite material and T-Scan II sensor. Bony changes were also evaluated with periapical radiographs. The changes of silicone thickness and T-Scan II sensored areas were statistically analyzed with repeated measured ANOVA and the Scheffe's post-hoc test at the 95% significance level. The following results have been made based on this study: 1. Alveolar bone loss was within 0.20mm and it was generally concluded within physiologic level. 2. There were no statistically significant differences in the thickness changes of silicone material at 1 month and 4 months of occlusal function. However, there was statistically significant difference at 10 months of occlusal function (p<0.05). 3. There was no statistically significant difference in changes of occlusal contact area in T-Scan II at 1 month and 4 months of occlusal function, but there was statistically significant difference at 10 months of occlusal function (p<0.05). Conclusively, as time goes by, implant occlusion to be formed infraocclusion was to be far close and increased occlusal contact. However, it was not observed destructive bone resorption in periapical radiographs and any other side effects.

Ti$_3$SiC$_2$의 기계적 성질 및 접촉 손상 거동 (Mechanical Propertis and Contact Damage Behavior of Ti$_3$SiC$_2$)

  • 이승건
    • 한국세라믹학회지
    • /
    • 제35권4호
    • /
    • pp.333-338
    • /
    • 1998
  • Mechanical properties of polycrystalline{{{{ {Ti }_{3 }{SiC}_{2 } }} were investigated. Hertzian indentation test using a spher-ical indenter was used to study elastic and plastic behavior in{{{{ {Ti }_{3 }{SiC}_{2 } }} A high ratio of hardness to elastic mo-dulus indicated that mechanical properties of{{{{ {Ti }_{3 }{SiC}_{2 } }} are somehow similar to those of metals. Indentation stress-strain curve deviated from an ideal elastic limit indicating exceptional plasticity in this material. De-formation zones were formed below the contact as well as around the contact area. Intragrain slip would ac-count for high plasticity.

  • PDF

Characteristics of Electron Beam Extraction in Large Area Electron Beam Generator

  • Woo, Sung-Hun;Lee, Hong-Sik
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제4C권1호
    • /
    • pp.10-14
    • /
    • 2004
  • A large area electron beam generator has been developed for industrial applications, for example, waste water cleaning, flue gas treatment, and food pasteurization. The operational principle is based on the emission of secondary electrons from the cathode when ions in the plasma contact the cathode, which are accelerated toward the exit window by the gradient of the electric potential. Conventional electron beam generators require an electron beam scanning mechanism because a small area thermal electron emitter is used. The electron beam of the large area electron beam generator does not need to be scanned over target material because the beam area is considerable. We have fabricated a large area electron beam generator with peak energy of 200keV, and a beam diameter of 200mm. The electron beam current has been investigated as a function of accelerating voltage and distance from the extracting window while its radial distribution in front of the extracting window has been also measured.

회색 관계 분석법을 이용한 누수 방지용 밸브 시트 설계 (Valve Seat Design for Full Contact Effect Using Grey Relational Analysis)

  • 이정희;강경아;곽재섭
    • 한국기계가공학회지
    • /
    • 제17권4호
    • /
    • pp.17-22
    • /
    • 2018
  • A glove valve regulates the flow in a pipeline as a kind of control valve. However, when the disc and seat contact, the valve structure can be distorted and flow can leak due to the elongation of the valve material under high pressure. The surface texture is not good enough to seal the contact surface (in practice) because the lapping process is usually done manually. Furthermore, assembly performance is analyzed by structural analysis. Compared with a standard seat, the newly designed seat had a smaller radial deformation and a larger longitudinal deformation. Therefore, the newly designed seat can maintain a tight and uniform contact with the disc with a reduced radial deformation and an expanded available seal area with an increased longitudinal deformation. The seal performance of the glove valve has been improved in a cost-effective manner.

Metal forming analysis using meshfree-enriched finite element method and mortar contact algorithm

  • Hu, Wei;Wu, C.T.
    • Interaction and multiscale mechanics
    • /
    • 제6권2호
    • /
    • pp.237-255
    • /
    • 2013
  • In this paper, a meshfree-enriched finite element method (ME-FEM) is introduced for the large deformation analysis of nonlinear path-dependent problems involving contact. In linear ME-FEM, the element formulation is established by introducing a meshfree convex approximation into the linear triangular element in 2D and linear tetrahedron element in 3D along with an enriched meshfree node. In nonlinear formulation, the area-weighted smoothing scheme for deformation gradient is then developed in conjunction with the meshfree-enriched element interpolation functions to yield a discrete divergence-free property at the integration points, which is essential to enhance the stress calculation in the stage of plastic deformation. A modified variational formulation using the smoothed deformation gradient is developed for path-dependent material analysis. In the industrial metal forming problems, the mortar contact algorithm is implemented in the explicit formulation. Since the meshfree-enriched element shape functions are constructed using the meshfree convex approximation, they pose the desired Kronecker-delta property at the element edge thus requires no special treatments in the enforcement of essential boundary condition as well as the contact conditions. As a result, this approach can be easily incorporated into a conventional displacement-based finite element code. Two elasto-plastic problems are studied and the numerical results indicated that ME-FEM is capable of delivering a volumetric locking-free and pressure oscillation-free solutions for the large deformation problems in metal forming analysis.

화학 기계적 연마에서 마찰력 감소에 관한 연구 (A study on the decay of friction force during CMP)

  • 권대희;김형재;정해도
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.972-975
    • /
    • 2002
  • An understanding of tribological behavior in CMP(Chemical Mechanical Polishing) is one of the most important things to reveal the mechanism of material removal. In CMP, the contact type is thought to be semi-direct, elastohydrodynamic contact type from the Stribeck diagram, which is a combination of solid-solid direct contact and hydrodynamic lubrication with thin liquid film. This study is focused on the decay of friction force during CMP from two points of view, one of which is change of the real contact area and the other is the decrease of the elastic modulus of the pad caused by the increase of the temperature during CMP Experiments are implemented with elastic modulus measuring system and tool dynamometer. Results show that the decay of friction force during CMP results from the decrease of the real contact pressure working on an abrasive, which is induced by the decrease of elastic modulus of pad caused by the increase of temperature. And, the phenomenon is thought to be happen specially in the case that the weight concentration of abrasive in slurry is small enough.

  • PDF

흑연소재가공용 공구의 DLC 코팅두께가 가공특성에 미치는 영향 (Effect on Tooling Characteristics to DLC-coated Thickness of Tool for Graphite Material)

  • 윤재호;김형균;최성대
    • 한국기계가공학회지
    • /
    • 제14권5호
    • /
    • pp.22-27
    • /
    • 2015
  • Processing of low toughness graphite material requires high-speed machine tools and DLC coating. In this study, results of investigation of the tool wear and machining properties of the DLC coating according to the thickness, and the machining time of the tool used for the machining of graphite electrodes, were as follows. 1. DLC coating thickness shows a larger wear amount of the tool center in accordance with thickness; the wear amount of the tool increases in proportion to the machining time. 2. The difference between the amount of wear depending on the processing time shows edge portions larger than the tool wear amount in the center. This amount of wear of the tool edge is formed since the rotating torque is in contact with the graphite material surface significantly more than the central portion. 3. The thicker the DLC coating, the more the coating tool eliminated of the coating area by the interface between the cemented carbide tool being coated with an increased friction of the graphite material and the DLC coating area.

패키징 소재 적용을 위한 RFID 태그 사이의 거리와 접촉 면적에 따른 인식률 분석 -제품의 수분함량을 중심으로- (Analysis of the Recognition Rate of Distance between RFID Tag and the Surface and the Contact Area for Application in Packaging Material -Focusing on Moisture Content of the Products-)

  • 윤성영;이학래;고의석;김도연;김재능
    • 한국포장학회지
    • /
    • 제23권1호
    • /
    • pp.1-7
    • /
    • 2017
  • RFID 시스템의 성능은 태그의 종류 및 리더 자체 성능뿐만 아니라 RFID 시스템을 응용하기 위한 물품의 종류, 포장 재질에 따른 태그 선택과 이에 따른 태그의 부착 위치 그리고 Antenna의 인식각도 등에 따라 큰 차이를 보인다. 본 연구는 이를 위해 RFID 인식률에 영향을 미치는 다양한 요인 중 가장 큰 영향을 미치는 수분함량을 중심으로 수분 함량별 RFID 인식률과 수분 함량에 따른 RFID 태그 사이의 거리 인식률 그리고 수분 함량에 따른 RFID 태그와 접촉면적에 따른 인식률을 측정하였다. 수분함량에 따른 인식률 분석에서는 0~25%의 수분을 함유할 경우 100% 인식이 가능하였으며, 수분함량이 30% 이상부터는 95% 이하 수준으로 떨어졌다. 수분 함량에 따른 RFID 태그 사이의 거리 인식률은 태그가 맞닿아 있을 경우보다 0.3 cm 이상일 경우가 더 인식률이 높았으며, 수분 함량에 따른 RFID 태그와 접촉면적에 따른 인식률에서는 접촉면적이 넓어질수록 인식률이 떨어지는 것을 확인하였다.

운동선수들의 구강 악 안면 영역에서의 스포츠 외상에 관한 설문조사 (THE SURVEY ON ORAL HEALTH AND MAXILLOFACIAL TRAUMA INCIDENCE OF THE SPORTS PLAYERS IN KOREA)

  • 박능석;우이형;백진;최대균
    • 대한치과보철학회지
    • /
    • 제45권4호
    • /
    • pp.534-545
    • /
    • 2007
  • Statement of problem: In spite of increasing sports injury, there was no collected data on the rate and type of dental injuries for athletes in Korea. Purpose: The purpose of this study was to investigate the occurrence of maxillofacial injuries and attitude of college sports player in Korea towards mouthguard. Material and methods: Total 617 athletes answered a series of questionnaire concerning their sports injury and using mouthguard. Results: 1. 81%(502) of athletes had, playing or training a sports, suffered an injury. Female athletes suffered an injury more than male athletes(p<0.05). Contact sports athletes were injured more than non contact sports athletes(p<0.05). 2. 335 athletes(54.8%) had suffered maxillofacial injuries while playing or training. 81.8% of athletes suffered an maxillofacial injury in contact sports(p<0.05). 3. Laceration of oral area, wrick in neck, fracture or avulsion on upper incisors, concussion, TMJ injury, fracture or avulsion on lower incisors, fracture or avulsion on lower molars were frequently injured area. 4. 67.2% of athletes answered that mouthguard could prevent sports injury especially high in contact sports(p<0.05). But only 39.1% of athletes required mouthguard while playing. 44.6% of athletes showed their intention of using mouthguard. Conclusion: This study shows that the incidence of maxillofacial injuries is very high while the actual use of mouthguard is very low. To prevent sports injury, a dentist must inform sports players and coaches of accurate information about mouthguard so that they can use it well. A dentist also has to provide them with better mouthguard on the basis of user's complaint.